Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 341
Filter
1.
Clin Anat ; 2024 May 08.
Article in English | MEDLINE | ID: mdl-38715464

ABSTRACT

The dysplastic hip is characterized by incomplete coverage of the femoral head, resulting in increased risk of early osteoarthritis. The morphological variation of the hip joint is diverse and clear differences exist between females and males. The aim of this observational study was therefore to investigate the relationship between the morphology of the hip, sex, and hip dysplasia using a three-dimensional model. Statistical shape models of the combined femur and pelvic bones were created from bilateral hips of 75 patients. Using manual angle measurements and regression analysis, the characteristic shape differences associated with sex and hip dysplasia were determined. The model showed clear differences associated with sex and hip dysplasia. We found that the acetabular anteversion in females was significantly higher (p < 0.0001) than in males while no significant difference in acetabular anteversion was found between normal and dysplastic hips (p = 0.11). The model showed that decreased acetabular anteversion resulted in the appearance of the cross-over sign and the prominent ischial spine sign commonly associated with retroversion. Sex could be predicted with an area under the curve of 0.99 and hip dysplasia could be predicted with an area under the curve of ≥0.73. Our findings suggest that retroversion is a result of decreased anteversion of the acetabulum and is primarily associated with sex. This finding should be taken into account during the reorientation of the acetabulum in the surgical treatment of hip dysplasia.

2.
Bone Joint Res ; 13(5): 226-236, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38719208

ABSTRACT

Aims: Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear. Methods: A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay. Results: At mean six years' follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041). Conclusion: The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear.

3.
Acta Orthop ; 95: 121-129, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38391197

ABSTRACT

BACKGROUND AND PURPOSE: Cementless arthroplasty fixation relies on early bone ingrowth and may be poor in patients with low proximal tibial bone density or abnormal bone turnover. We aimed first to describe the baseline bone properties in patients undergoing medial unicompartmental knee replacement (UKR), and second to investigate its association with cemented and cementless tibial component migration until 2 years. METHODS: A subset investigation of 2 patient groups from a 3-armed randomized controlled trial was conducted. There were 26 cemented and 25 cementless medial UKRs with twin-pegged femoral components. Volumetric bone mineral density (vBMD) and microstructure of the excised medial tibial plateau were ascertained with µCT. Bone turnover was estimated using dynamic histomorphometry (eroded surface/bone surface = ES/BS, osteoid surface/bone surface = OS/BS, mineralizing surface/bone surface = MS/BS). Tibial component migration in 4 feature points was followed for 2 years with radiostereometry. RESULTS: At the 2-year follow-up, the cementless tibial components migrated 0.38 mm (95% confidence interval [CI] 0.14-0.62) total translation more than the cemented components at the posterior feature point. The greatest migration in the cementless group was subsidence at the posterior feature point of 0.66 mm (CI 0.48-0.84) until 6 weeks, and from 3 months the components were stable. Cemented tibial components subsided very little. Between 1- and 2-year follow-ups, no cementless but 4 cemented tibial components revealed continuous migration. OS/BS was half of the ES/BS. No µCT or histomorphometric parameters showed any clinically relevant correlation with tibial component migration at the posterior feature point for either cemented or cementless UKR at 6 weeks' or 2 years' follow-up after adjustment for age, BMI, and sex. CONCLUSION: Preoperative vBMD, bone turnover, and microstructure were not associated with postoperative tibial component migration of cemented and cementless medial UKR.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/adverse effects , Bone Density , Knee Prosthesis/adverse effects , Prosthesis Failure , Knee Joint/surgery , Bone Cements , Prosthesis Design , Treatment Outcome , Osteoarthritis, Knee/surgery
4.
Int J Orthop Trauma Nurs ; 52: 101079, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38147803

ABSTRACT

INTRODUCTION: The documentation on patient reported outcomes the first weeks at home following total hip arthroplasty (THA) is sparse. Length of hospital stay after THA is substantially reduced. Therefore, knowledge on whether patients are managing their own postoperative rehabilitation early after discharge is important, in order to give the patients realistic preoperative information, to modify expectations and enable patients to monitor their own rehabilitation process. METHODS: Eighty-two THA patients were included in a prospective cohort study. Patient-reported outcomes were collected twice a week thirty days postoperatively using a web-based registration tool. Numeric rating scales (0-10) for pain, function, and quality of life, EQ-5D, and the use of opioids were registered. Four weeks postoperatively a telephone interview were conducted. Pain, EQ5D and hip specific physical function score (HOOS-PS) were recorded preoperatively, at three- and twelve-months follow-up. RESULTS: Pain was maintained the first days after hospital discharge. From day 0 to day 30, pain decreased from 4.0 (SD 2.23) to 2.3 (SD 1.75), function improved from 4.4 (SD 2.06) to 7 (SD 1.57), quality of life improved from 6.3 (SD 2.69) to 7.8 (SD 1.47), and EQ-5D improved from 0.4 to (SD 0.27) to 0.7 (SD 0.14). After 30 days, 32% still used opioids. All patients completed the web-registration. Pain, EQ-5D and HOOS-PS improved substantially from preoperatively to twelve months follow-up. CONCLUSION: Fast-track THA patients can expect continued postoperative pain and impaired quality of life the first week at home, before gradually improvement. After thirty days, 32 % of the patients still used opioids.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Follow-Up Studies , Prospective Studies , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/rehabilitation , Quality of Life , Pain, Postoperative/drug therapy , Patient Reported Outcome Measures , Internet , Treatment Outcome
5.
Arch Orthop Trauma Surg ; 143(12): 7169-7183, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37568057

ABSTRACT

BACKGROUND: The component design and fixation method of joint arthroplasty may affect component migration and survival. The aim of this study was to compare fixation of cementless twin-peg (CLTP), cemented twin-peg (CTP) and cemented single-peg (CSP) femoral components of medial unicompartmental knee replacement (UKR). METHODS: Eighty patients (mean age = 63 years, 48 males) with medial knee osteoarthritis were randomized in three ways to CLTP (n = 25), CTP (n = 26) or CSP (n = 29) femoral UKR components. The patients were followed 5 years postoperatively with RSA, bone mineral density (BMD), PROMs and radiological evaluation of radiolucent lines (RLL), femoral component flexion angle and complications. RESULTS: At the 5-year follow-up, femoral component total translation was comparable between the three groups (p = 0.60). Femoral component internal rotation was 0.50° (95% CI 0.3; 0.69) for the CLTP group, 0.58° (95% CI 0.38; 0.77) for the CTP group and 0.25° (95% CI 0.07; 0.43) for the CSP group (p = 0.01). BMD decreased peri-prosthetically (range - 11.5%; - 14.0%) until 6-month follow-up and increased toward the 5-year follow-up (range - 3.6%; - 5.8%). BMD change did not correlate with component migration. Lower flexion angle was correlated with higher 5-year subsidence, total translation, varus rotation and maximum total point motion (p = 0.01). Two patients (1 CLTP, 1 CTP) had RLL in the posterior zone. There were two revisions. CONCLUSION: At 5-year follow-up, fixation of UKA femoral components with twin-peg was not superior to the single-peg design. Cementless and cemented twin-peg femoral components had similar fixation. A lower flexion angle was correlated with higher component migration.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Male , Humans , Middle Aged , Arthroplasty, Replacement, Knee/methods , Prosthesis Design , Osteoarthritis, Knee/surgery , Radiography , Treatment Outcome , Knee Joint/surgery , Prosthesis Failure , Bone Cements
6.
Antibiotics (Basel) ; 12(3)2023 Mar 14.
Article in English | MEDLINE | ID: mdl-36978444

ABSTRACT

(1) Introduction: Piperacillin is a common antibiotic choice in the treatment of periprosthetic joint infections (PJI) caused by Pseudomonas aeruginosa. The aim of this study was to assess and compare the time with free piperacillin concentration above the minimum inhibitory concentration (fT > MIC) at steady state in target tissues relevant for PJI treatment following continuous and intermittent short-term infusion. (2) Methods: 16 pigs were randomized to receive either continuous or intermittent short-term infusion of piperacillin. Steady state piperacillin concentrations were assessed using microdialysis in tibial cortical bone, tibial cancellous bone, synovial fluid of the knee joint, and subcutaneous tissue. MIC-targets of 4, 8, 16, and 64 mg/L were applied. Plasma samples were obtained as reference. (3) Results: Continuous infusion resulted in longer fT > MIC for MIC targets of 4 mg/L and 8 mg/L compared to intermittent short-term infusion in all compartments with the exception of tibial cortical bone. For the MIC-target of 16 mg/L, continuous infusion resulted in a longer fT > MIC in all compartments except for the bone compartments. No differences between groups were seen when applying a MIC-target of 64 mg/L. (4) Conclusions: An aggressive dosing strategy may be necessary to obtain sufficient piperacillin concentrations in all bone compartments, particularly if more aggressive targets are applied. Based on the present study, continuous infusion should be considered in the treatment of PJI.

7.
Antibiotics (Basel) ; 12(3)2023 Mar 20.
Article in English | MEDLINE | ID: mdl-36978481

ABSTRACT

Implant-associated osteomyelitis is one of the most feared complications following orthopedic surgery. Although the risk is low, sufficient antibiotic protection of the implant surface is important. The aim of this study was to assess steady-state piperacillin concentrations in the proximity of an orthopedic implant. Time above the minimal inhibitory concentration (fT>MIC) was evaluated for MIC of 8 (low target) and 16 µg/mL (high target). Six female pigs received an intravenous bolus infusion of 4 g/0.5 g piperacillin/tazobactam over 30 min every 6 h. Steady state was assumed achieved in the third dosing interval (12-18 h). Microdialysis catheters were placed in a cannulated screw in the proximal tibial cancellous bone, in cancellous bone next to the screw, and in cancellous bone on the contralateral tibia. Dialysates were collected from time 12 to 18 h and plasma samples were collected as reference. For the low piperacillin target (8 µg/mL), comparable mean fT>MIC across all the investigated compartments (mean range: 54-74%) was found. For the high target (16 µg/mL), fT>MIC was shorter inside the cannulated screw (mean: 16%) than in the cancellous bone next to the screw and plasma (mean range: 49-54%), and similar between the two cancellous bone compartments. To reach more aggressive piperacillin fT>MIC targets in relation to the implant, alternative dosing regimens such as continuous infusion may be considered.

8.
Arch Orthop Trauma Surg ; 143(9): 5967-5976, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36802238

ABSTRACT

BACKGROUND: Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate the influence of the anterolateral (AntLat) and the posterior (Post) surgical approach on the location, grade and prevalence of pseudotumors and muscle atrophy in MoM RHA. PATIENTS AND METHODS: Forty-nine patients were randomized to MoM RHA by the AntLat (n = 25) or the Post (n = 24) approach at Aarhus University Hospital. Patients underwent metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) scans for investigation of location, grade and prevalence of pseudotumors and muscle atrophy. Plain radiographs, metal-ions concentrations and clinical outcome scores were evaluated to compare outcomes of the surgical approaches. RESULTS: MRI-detected pseudotumors were seen in 7 of 18 patients (39%) in the AntLat group and in 12 of 22 patients (55%) in the Post group (p = 0.33). Pseudotumors were mainly located anterolaterally to the hip joint in the AntLat group and postero-lateral to the hip joint in the Post group. Higher grades of muscle atrophy of the caudal part of the gluteus medius and minimus (p < 0.004) were seen in the AntLat group, and higher grades of muscle atrophy of the small external rotators were seen in the Post group (p < 0.001). The AntLat group had higher anteversion angles of mean 15.3° (range 6.1-7.5) versus mean 11.5° (range 4.9-22.5) in the Post group (p = 0.02). Metal-ion concentrations and clinical outcome scores were similar between groups (p > 0.08). CONCLUSION: Muscle atrophy and pseudotumor location after MoM RHA follow the surgical approach used for implantation. This knowledge may help differentiate between "normal postoperative appearance" and "MoM disease."


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Metal-on-Metal Joint Prostheses , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Metals , Magnetic Resonance Imaging/methods , Muscular Atrophy/diagnostic imaging , Muscular Atrophy/etiology , Prosthesis Design , Cobalt
9.
Arch Orthop Trauma Surg ; 143(9): 5957-5965, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36802237

ABSTRACT

INTRODUCTION: Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS: A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS: Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS: Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Dislocation , Hip Prosthesis , Humans , Female , Polyethylene , Hip Dislocation/surgery , Prosthesis Failure , Prosthesis Design , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Follow-Up Studies
11.
Mol Genet Genomics ; 298(2): 329-342, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36454308

ABSTRACT

Developmental dysplasia of the hip (DDH) is a common condition involving instability of the hip with multifactorial etiology. Early diagnosis and treatment are critical as undetected DDH is an important cause of long-term hip complications. Better diagnostics may be achieved through genetic methods, especially for patients with positive family history. Several candidate genes have been reported but the exact molecular etiology of the disease is yet unknown. In the present study, we performed whole exome sequencing of DDH patients from 28 families with at least two affected first-degree relatives. Four genes previously not associated with DDH (METTL21B, DIS3L2, PPP6R2, and TM4SF19) were identified with the same variants shared among affected family members, in more than two families. Among known association genes, we found damaging variants in DACH1, MYH10, NOTCH2, TBX4, EVC2, OTOG, and SHC3. Mutational burden analysis across the families identified 322 candidate genes, and enriched pathways include the extracellular matrix, cytoskeleton, ion-binding, and detection of mechanical stimulus. Taken altogether, our data suggest a polygenic mode of inheritance for DDH, and we propose that an impaired transduction of the mechanical stimulus is involved in the etiopathological mechanism. Our findings refine our current understanding of candidate causal genes in DDH, and provide a foundation for downstream functional studies.


Subject(s)
Developmental Dysplasia of the Hip , Hip Dislocation, Congenital , Humans , Exome Sequencing , Hip Dislocation, Congenital/genetics , Hip Dislocation, Congenital/diagnosis , Hip Dislocation, Congenital/pathology , Pedigree , Denmark
12.
Arch Orthop Trauma Surg ; 143(2): 1071-1080, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35113240

ABSTRACT

INTRODUCTION: The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. MATERIAL AND METHOD: In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70-89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> - 1) and low (< - 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. RESULTS: At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was - 0.04° (CI 95% - 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% - 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). CONCLUSION: The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Female , Aged , Radiostereometric Analysis , Hip Prosthesis/adverse effects , Follow-Up Studies , Prospective Studies , Cohort Studies , Prosthesis Design , Pain/etiology , Prosthesis Failure
13.
Acta Orthop ; 93: 658-664, 2022 07 14.
Article in English | MEDLINE | ID: mdl-35848733

ABSTRACT

BACKGROUND AND PURPOSE: BoneMaster (BM) is a thin electrochemically applied hydroxyapatite (HA) implant coating marketed with expectations of improved osseointegration properties but less polyethylene (PE) wear. We compared the midterm cup migration and PE wear of cementless porous-coated hemispherical cups with and without BM. PATIENTS AND METHODS: In this patient-blinded, randomized controlled trial, 53 patients with a mean age of 64 years (55-75) received total hip arthroplasty with a porous-coated (P) or porous and BoneMaster (PBM) coated Exceed cup and ArCom E1 infused PE. Patients were followed with RSA, Hip Osteoarthritis Outcome Score (HOOS), and Euro-Qol-5-3L (EQ-5D) at 3 and 6 months, and 1-, 2-, and 5-year follow-up. RESULTS: At 5-year follow-up, total translation and maximum total point motion was 0.28 mm (95% CI 0.08; 0.47) and 0.52 mm (CI 0.12; 0.93) higher in the PBM group than in the P group. PE wear was comparable between PBM and P cups, and 2D wear rate from 1-year follow-up to last follow-up was 0.03 mm (CI 0.02-0.03). The 5-year anterior translation was 0.05 mm (CI -0.10 to 0.21) in the normal BMD group and 0.40 mm (CI 0.22-0.57) in the osteopenia group. INTERPRETATION: At 5-year follow-up, Exceed cups in the PBM group migrated more than in the P group but the PE wear rate was low and similar. This study does not indicate any advantage of additional BoneMaster coating compared with porous coating alone on cementless hemispherical cups with regards to migration, polyethylene wear, and clinical outcomes.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Durapatite , Follow-Up Studies , Humans , Middle Aged , Polyethylene , Porosity , Prosthesis Design , Prosthesis Failure , Titanium
14.
Antibiotics (Basel) ; 11(7)2022 Jul 07.
Article in English | MEDLINE | ID: mdl-35884164

ABSTRACT

Background: Piperacillin is a central drug in the treatment of Pseudomonas aeruginosa spondylodiscitis. Intermittent short-term infusion (STI) remains standard treatment in most centres, although the application of continuous infusion (CI) has shown promising results in other clinical settings. We aimed to evaluate time above the minimal inhibitory concentration (fT > MIC) of the free fraction of piperacillin in steady state conditions in porcine cervical spine tissue following CI and STI using microdialysis with MIC targets of 4, 8, and 16 µg/mL. Methods: 16 female pigs were randomized to receive piperacillin/tazobactam as STI (4/0.5 g every 6 h) or CI (4/0.5 g as a bolus followed by 12/1.5 g) for 18 h. Microdialysis catheters were placed for sampling of piperacillin concentrations from the intervertebral disc, vertebral cancellous bone, paravertebral muscle, and adjacent subcutaneous tissue during the third dosing interval (12−18 h). Blood samples were collected as reference. Results: CI resulted in fT > MIC > 82% across all compartments and targets, except for intervertebral disc (37%) and vertebral cancellous bone (28%) at MIC = 16 µg/mL. In Group STI, >72% fT > MIC was reached for MIC = 4 µg/mL in all investigated compartments, while for MIC = 16 µg/mL only subcutaneous tissue exhibited fT > MIC > 50%. Conclusion: CI of piperacillin resulted in higher fT > MIC compared to STI infusion across the investigated tissues and targets. CI should therefore be considered in spondylodiscitis cases requiring piperacillin treatment.

15.
Musculoskelet Sci Pract ; 61: 102615, 2022 10.
Article in English | MEDLINE | ID: mdl-35820302

ABSTRACT

BACKGROUND AND OBJECTIVES: To evaluate the feasibility and acceptability of exercise and patient education for patients with hip dysplasia not receiving surgery. DESIGN: Feasibility study. METHODS: The participants received exercise instruction and patient education over six months. Feasibility covered recruitment, retention, and mechanisms of change (MC). MC were measured with Hip and Groin Outcome Score (HAGOS), muscle strength tests, Y-balance test, and hop for distance test (HDT) over six months. Acceptability covered adherence, expectations, perceptions, benefits, and harms. RESULTS: Thirty of 32 were recruited (median age: 30 years); six were lost to follow-up. Twenty-four participants improved by a mean of 11 (95%CI: 5-17) HAGOS pain points, improvements in all subscales were 1-11 points. Mean hip abduction strength improved 0.2 (95%CI: 0.04-0.4) Nm/kg, similar to flexion and extension. Median Y-balance test improvements: anterior: 70 (IQR: 64-74) to 75 (IQR: 72-80) centimetres; posteromedial: 104 (IQR: 94-112) to 119 (IQR: 112-122) centimetres and posterolateral: 98 (IQR: 89-109) to 116 (IQR: 108-121) centimetres (p < .001). Median improvement in HDT was: 37 (IQR: 30-44) to 52 (IQR: 45-58) centimetres (p < .001). Participants adhered to 84% of scheduled sessions (1,581:1,872), expectations were met, and perceptions were characterized by high self-efficacy for exercise. Benefits were reported with no serious harms. CONCLUSION: Patients with hip dysplasia are willing to be recruited for exercise and patient education, with acceptable retention. MC were observed through improvements in pain, strength and function with high acceptance of the exercise and patient education intervention. Thus, it seems feasible to conduct a full-scale randomised controlled trial.


Subject(s)
Hip Dislocation , Adult , Arthralgia , Feasibility Studies , Humans , Pain , Patient Education as Topic
16.
Bone Joint J ; 104-B(6): 647-656, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35638207

ABSTRACT

AIMS: BoneMaster is a thin electrochemically applied hydroxyapatite (HA) coating for orthopaedic implants that is quickly resorbed during osseointegration. Early stabilization is a surrogacy marker of good survival of femoral stems. The hypothesis of this study was that a BoneMaster coating yields a fast early and lasting fixation of stems. METHODS: A total of 53 patients were randomized to be treated using Bi-Metric cementless femoral stems with either only a porous titanium plasma-sprayed coating (P group) or a porous titanium plasma-sprayed coating with an additional BoneMaster coating (PBM group). The patients were examined with radiostereometry until five years after surgery. RESULTS: At three months, the mean total translation (TT) was 0.95 mm (95% confidence interval (CI) 0.68 to 1.22) in the P group and 0.57 mm (95% CI 0.31 to 0.83) in the PBM group (p = 0.047). From two to five years, the TT increased by a mean of 0.14 mm (95% CI 0.03 to 0.25) more in the P group than in the PBM group (p = 0.021). In osteopenic patients (n = 20), the mean TT after three months was 1.61 mm (95% CI 1.03 to 2.20) in the P group and 0.73 mm (95% CI 0.25 to 1.21) in the PBM group (p = 0.023). After 60 months, the mean TT in osteopenic patients was 1.87 mm (95% CI 1.24 to 2.50) in the P group and 0.82 mm (95% CI 0.30 to 1.33) in the PBM group (p = 0.011). CONCLUSION: There was less early and midterm migration of cementless stems with BoneMaster coating compared with those with only a porous titanium plasma-sprayed coating. Although a BoneMaster coating seems to be important for stem fixation, especially in osteopenic patients, further research is warranted. Cite this article: Bone Joint J 2022;104-B(6):647-656.


Subject(s)
Hip Prosthesis , Radiostereometric Analysis , Coated Materials, Biocompatible , Durapatite , Follow-Up Studies , Humans , Porosity , Titanium
18.
Acta Orthop ; 93: 375-381, 2022 03 21.
Article in English | MEDLINE | ID: mdl-35347340

ABSTRACT

BACKGROUND AND PURPOSE: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). PATIENTS AND METHODS: 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. RESULTS: Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5-20), inclination 6° (2-12), and rotation 11° (5-48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12-46) and in liner/cup angle (larger articulation) was 6° (4-21). Static RSA showed changes in median liner anteversion from 7° (-12 to 23) postoperatively to 10° (-3 to 16) at 1-year follow-up and inclination from 42° (35-66) postoperatively to 59° (46-80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). INTERPRETATION: The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Humans , Polyethylene , Radiostereometric Analysis , Range of Motion, Articular
19.
J Orthop Res ; 40(11): 2688-2697, 2022 11.
Article in English | MEDLINE | ID: mdl-35220595

ABSTRACT

In a randomized controlled setting, medium-term implant migration and long-term clinical outcomes were compared for the Copeland and the Global C.A.P. humeral head resurfacing implants (HHRI). Thirty-two patients (mean age 63 years) were randomly allocated to a Copeland (n = 14) or Global C.A.P. (n = 18) HHRI. Patients were followed for 5 years with radiostereometry, Constant Shoulder Score, and the Western Ontario Osteoarthritis of the Shoulder Index (WOOS). WOOS and revision status were also obtained cross-sectionally at a mean 10-year follow-up. At the 5-year follow-up, total translation (TT) was 0.75 mm (95% confidence interval [CI]: 0.53-0.97) for the Copeland HHRIs and 1.15 mm (95% CI: 0.85-1.46) for the Global C.A.P. HHRIs (p = 0.04), but the clinical scores were similar at all follow-ups. The cumulative risks of revision at 5 and 10 years were 29% and 43% for Copeland and 35% and 41% for Global C.A.P HHRIs (p > 0.7). No implants were loose at revision, but HHRIs that were later revised followed an early offset-increasing migration pattern with medial translation and lift-off resulting in a mean 0.53 mm (95% CI: 0.18-0.88) higher TT at the 1-year follow-up compared to non-revised HHRIs. In conclusion, the Global C.A.P. HHRI had higher TT compared with the Copeland HHRI, but clinical scores and revision rates were similar. Nonetheless, revision rates were high and challenge the use of HHRIs. Interestingly, an early radiostereometry evaluated HHRI migration pattern with increased off-set predicted later implant revision.


Subject(s)
Osteoarthritis , Shoulder Joint , Follow-Up Studies , Humans , Humeral Head/diagnostic imaging , Humeral Head/surgery , Middle Aged , Osteoarthritis/diagnostic imaging , Osteoarthritis/surgery , Radiostereometric Analysis , Treatment Outcome
20.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 3100-3113, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35099597

ABSTRACT

PURPOSE: Cementless tibial components migrate initially until osseointegration and preserve periprosthetic bone. Cemented tibial components are fixed from surgery but loose periprosthetic bone. Little is known about bone formation and resorption biomarkers in relation to component fixation and bone mineral density (BMD) changes of cementless and cemented total knee arthroplasty. We hypothesize a similar migration of cemented and cementless tibial components between 1- and 2-year follow-up indicating a stable long-term fixation. METHODS: In a prospective patient-blinded randomized study, we compared cementless (n = 27) and cemented (n = 26) tibial components with radiostereometry measured migration (MTPM = Maximum Total Point Motion: point of component that migrates the most) and changes in BMD and biochemical bone turnover markers (BTMs) until 24 months after surgery. RESULTS: The mean MTPM between 12 and 24 months were similar between groups with - 0.06 mm (95% CI - 0.23; 0.11) in the cementless group compared to 0.02 mm (95% CI - 0.07; 0.11) in the cemented group. However, there was a higher proportion of cementless components (16/25) than cemented components (7/24) with continuous migration (MTPM > 0.2 mm) (p = 0.02). In the medial and anterior region below the tibial components, the BMD increased by mean 1.8% and 7.4% for cementless components and decreased by mean 8.6% and 4.2% for cemented components until 24-month follow-up. In both groups, BTMs initially showed increased bone resorption (CTx) and bone formation (P1NP) followed by normalization to pre-operative levels at 6 months post-surgery. CONCLUSION: More cementless components than cemented components showed continues migration which suggest a higher risk of early revision. Bone turnover increased post-surgery in both groups, but did not explain the difference in change in periprosthetic BMD. LEVEL OF EVIDENCE: I.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Bone Cements , Bone Density , Bone Remodeling , Follow-Up Studies , Humans , Prospective Studies , Prosthesis Design , Prosthesis Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...