Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 181
Filter
1.
BMC Musculoskelet Disord ; 23(1): 489, 2022 May 24.
Article in English | MEDLINE | ID: mdl-35610637

ABSTRACT

BACKGROUND: Patients suffering cartilage defects of the medial compartment with underlying varus deformity do benefit from high tibial osteotomy (HTO) even in the long term. Nonetheless, kinematic and geometric changes especially in the patellofemoral joint have been described. Purpose of the present study was to evaluate the influence of patellofemoral cartilage defects detected during the diagnostic arthroscopy and their influence on HTO's postoperative outcome. METHODS: Ninety patients with a mean follow-up of 10.08 ± 2.33 years after surgery were included. Patients were divided into four groups according to their cartilage status in the patellofemoral joint (A = no defects, B = isolated lesions of the patella, C = isolated lesions of the trochlea, D = kissing lesions). Functional outcome was evaluated before surgery and about ten years thereafter by relying on the IKDC, Lysholm, and KOOS scores. Radiological parameters were assessed pre- and six weeks postoperatively. RESULTS: In groups A to D, the HTO led to significant patellar distalisation in the sagittal view, with the mean indices remaining at or above the limit to a patella baja. All patients in all groups profited significantly from HTO (higher Lysholm score, lower VAS p < 0.001), patients in group D had the lowest outcome scores. Patella height negatively influenced outcome scores in group C (Blackburne-Peel-Index-VAS p = 0.033) and D (Caton-Deschamps-Index-Tegner p = 0.018), a larger valgus correction was associated with lower outcome scores in group D (Lysholm p = 0.044, KOOSpain 0.028, KOOSQOL p = 0.004). CONCLUSION: Long-term results of HTO for varus medial compartment osteoarthritis remain good to excellent even in the presence of patellofemoral defects. Overcorrection should be avoided. Distal biplanar HTO should be considered for patients presenting trochlear or kissing lesions of the patellofemoral joint. TRIAL REGISTRATION: DRKS00015733 in the German Registry of Clinical Studies.


Subject(s)
Cartilage Diseases , Osteoarthritis, Knee , Patellofemoral Joint , Cartilage , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Osteotomy/adverse effects , Osteotomy/methods , Patellofemoral Joint/diagnostic imaging , Patellofemoral Joint/surgery , Retrospective Studies , Tibia/diagnostic imaging , Tibia/surgery
2.
Proc Inst Mech Eng H ; 236(6): 841-847, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35373636

ABSTRACT

Olecranon fractures are most frequently stabilized by tension band wiring (TBW), which unfortunately leads to relevant implant removal rates due to K-wire migration and soft tissue irritation. As lag screw osteosynthesis (LSO) might be a gentle and effective alternative in simple fracture patterns, the goal of the present study was to biomechanically compare LSO with TBW in simple olecranon fractures at a cadaver model. A simple olecranon fracture (Mayo type IIA) was created in eight pairs of human cadaver elbows, which were pairwise fixed by either TBW or two transcortical 4.0 mm lag screws. Biomechanical testing was conducted as a pulling force, applied to the triceps tendon in a 90° position. First, cyclic loading between 10 and 300 N was performed for 50,000 cycles. Afterward, maximum load was raised by 0.02 N/cycle until construct failure, what was defined as displacement >2 mm. Besides fracture displacement, failure cycle and failure load, the modes of failure were analyzed. Within the first five cycles, there was no significant difference in displacement (median TBW: 0.2 mm; LSO: 0.5 mm; p = 0.091). Both after 2000 (median TBW: 0.2 mm; LSO: 0.6 mm; p = 0.042) and after 20,000 cycles (median TBW: 0.4 mm; LSO: 0.9 mm; p = 0.027), the difference was significant. Failure cycle (median TBW: 72,639 cycles; LSO: 43,429 cycles; p = 0.017) and failure load (median TBW: 702 N; LSO: 303 N; p = 0.025) differed significantly as well. TBW mostly (6/8) failed at the lock of the cerclage wire, whereas most LSO constructs (5/8) failed as a pullout of the proximal fragment. In conclusion, to our biomechanical findings at human cadaver specimens, simple olecranon fractures treated by LSO show higher dislocation rates and lower failure loads compared to conventional TBW and mostly fail by pullout of the proximal fragment.


Subject(s)
Fractures, Bone , Olecranon Process , Ulna Fractures , Biomechanical Phenomena , Bone Screws , Bone Wires , Cadaver , Fracture Fixation, Internal , Fractures, Bone/surgery , Humans , Olecranon Process/surgery , Ulna Fractures/surgery
5.
J Shoulder Elbow Surg ; 30(7): 1519-1526, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33359398

ABSTRACT

BACKGROUND: In the treatment of unstable olecranon fractures, anatomically preshaped locking plates exhibit superior biomechanical results compared with tension band wiring. However, posterior plating (PP) still is accompanied by high rates of plate removal because of soft-tissue irritation and discomfort. Meanwhile, low-profile plates precontoured for collateral double plating (DP) are available and enable muscular soft-tissue coverage combined with angular-stable fixation. The goal of this study was to biomechanically compare PP with collateral DP for osteosynthesis of unstable osteoporotic fractures. METHODS: A comminuted displaced Mayo type IIB fracture was created in 8 osteoporotic pairs of fresh-frozen human cadaveric elbows. Pair-wise angular stable fixation was performed by either collateral DP or PP. Biomechanical testing was conducted as a pulling force to the triceps tendon in 90° of elbow flexion. Cyclical load changes between 10 and 300 N were applied at 4 Hz for 50,000 cycles. Afterward, the maximum load was raised by 0.02 N/cycle until construct failure, which was defined as displacement > 2 mm. Besides failure cycles and failure loads, modes of failure were analyzed. RESULTS: Following DP, a median endurance of 65,370 cycles (range, 2-83,121 cycles) was recorded, which showed no significant difference compared with PP, with 69,311 cycles (range, 150-81,938 cycles) (P = .263). Failure load showed comparable results as well, with 601 N (range, 300-949 N) after DP and 663 N (range, 300-933 N) after PP (P = .237). All PP constructs and 3 of 8 DP constructs failed by proximal fragment cutout, whereas 5 of 8 DP constructs failed by bony triceps avulsion. CONCLUSION: Angular-stable DP showed comparable biomechanical stability to PP in unstable osteoporotic olecranon fractures under high-cycle loading conditions. Failure due to bony triceps avulsion following DP requires further clinical and biomechanical investigation, for example, on suture augmentation or different screw configurations.


Subject(s)
Olecranon Process , Osteoporotic Fractures , Biomechanical Phenomena , Bone Plates , Cadaver , Fracture Fixation, Internal , Humans , Olecranon Process/surgery
6.
Knee Surg Sports Traumatol Arthrosc ; 29(1): 230-239, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32240344

ABSTRACT

PURPOSE: Capsular volume reduction in the context of anterior arthroscopic shoulder stabilization represents an important but uncontrolled parameter. The aim of this study was to analyse capsular volume reduction by arthroscopic Bankart repair with an individualized capsular shift in patients with and without ligamentous hyperlaxity compared to a control group. METHODS: In the context of a prospective controlled study, intraoperative capsular volume measurements were performed in 32 patients with anterior shoulder instability before and after arthroscopic Bankart repair with an individualized capsular shift. The results were compared to those of a control group of 50 patients without instability. Physiological shoulder joint volumes were calculated and correlated with biometric parameters (sex, age, height, weight and BMI). RESULTS: Patients with anterior shoulder instability showed a mean preinterventional capsular volume of 35.6 ± 10.6 mL, which was found to be significantly reduced to 19.3 ± 5.4 mL following arthroscopic Bankart repair with an individualized capsular shift (relative capsular volume reduction: 45.9 ± 21.9%; P < 0.01). Pre-interventional volumes were significantly greater in hyperlax than in non-hyperlax patients, while post-interventional volumes did not differ significantly. The average shoulder joint volume of the control group was 21.1 ± 7.0 mL, which was significantly correlated with sex, height and weight (P < 0.01). Postinterventional capsular volumes did not significantly differ from those of the controls (n.s.). CONCLUSION: Arthroscopic Bankart repair with an individualized capsular shift enabled the restoration of physiological capsular volume conditions in hyperlax and non-hyperlax patients with anterior shoulder instability. Current findings allow for individual adjustment and intraoperative control of capsular volume reduction to avoid over- or under correction of the shoulder joint volume. Future clinical studies should evaluate, whether individualized approaches to arthroscopic shoulder stabilization are associated with superior clinical outcome.


Subject(s)
Arthroscopy/methods , Bankart Lesions/complications , Joint Instability/surgery , Shoulder Joint/surgery , Adult , Female , Humans , Joint Instability/etiology , Joint Instability/physiopathology , Male , Middle Aged , Recurrence , Shoulder Joint/physiology , Young Adult
7.
J Shoulder Elbow Surg ; 30(2): 365-372, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32619657

ABSTRACT

BACKGROUND: Biodegradable implants have gained increasing importance for the fixation of simple displaced radial head fractures to supersede implant removal and to minimize cartilage destruction. Commonly used polylactide pins still lead to higher rates of secondary loss of reduction compared with metal implants. Alternatively, implants made from a magnesium alloy meanwhile are available in a pin design that hypothetically could perform better than polylactide pins. Because biomechanical data of clinical applications are lacking, the goal of the present study was to biomechanically compare magnesium pins to polylactide pins using a Mason type II radial head fracture model. METHODS: Fourteen pairs of fresh-frozen human cadaver radii with a standardized Mason type II radial head fracture were stabilized either by two 2.0-mm polylactide pins (PPs) or two 2.0-mm magnesium pins (MPs). Biomechanical in vitro testing was conducted as 10 cycles of static loading at 0.1 Hz axially and transversally between 10 and 50 N. Afterward, loosening was tested by dynamic load changes at 4 Hz up to 100,000 cycles. Early fracture displacement was measured after 10,000 cycles. Afterward, maximum loads were raised every 10,000 cycles by 15 N until construct failure, which was defined as fracture displacement ≥2 mm. RESULTS: MP osteosynthesis showed a tendency toward higher primary stability on both axial (MP: 0.19 kN/mm, PP: 0.11 kN/mm; P = .068) and transversal loading (MP: 0.11 kN/mm, PP: 0.10 kN/mm; P = .068). Early fracture displacement was significantly higher following PP osteosynthesis (MP: 0.3 mm, PP: 0.7 mm; P = .030). The superiority of MP was also significant during cyclic loading, represented in a higher failure cycle (MP: 30,684, PP: 5113; P = .009) and in higher failure loads (MP: 95 N, PP: 50 N; P = .024). CONCLUSION: According to our findings, in simple radial head fractures, osteosynthesis with magnesium pins show superior biomechanical properties compared with fractures treated by polylactide pins. Prospective investigations should follow to evaluate clinical outcomes and resorption behavior.


Subject(s)
Radius Fractures , Biomechanical Phenomena , Bone Nails , Fracture Fixation, Internal , Humans , Magnesium , Polyesters , Prospective Studies , Radius Fractures/surgery
8.
Bone Joint Res ; 9(9): 534-542, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32922762

ABSTRACT

AIMS: Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). METHODS: A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure. RESULTS: The biomechanical benefit was already significant with a single cemented screw and increased with the number of augmented screws, but the configuration was highly influential. The best two-screw (mean 23%, SD 3% reduction) and the worst four-screw (mean 22%, SD 5%) combinations performed similarly. The largest benefits were achieved with augmenting screws purchasing into the calcar and having posteriorly located tips. Local bone mineral density was not directly related to the improvement. CONCLUSION: The number and configuration of cemented screws strongly determined how augmentation can alleviate the predicted risk of cut-out failure. Screws purchasing in the calcar and posterior humeral head regions may be prioritized. Although requiring clinical corroborations, these findings may explain the controversial results of previous clinical studies not controlling the choices of screw augmentation.

9.
J Shoulder Elbow Surg ; 29(9): 1912-1919, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32417047

ABSTRACT

BACKGROUND: Displaced fractures of the humeral capitellum are commonly treated operatively and fixed by titanium screws (TSs) either directly or indirectly. In the case of direct transcartilaginous fixation, biodegradable screws with the ability to be countersunk can be favorable regarding implant impingement and cartilage destruction. Hence, the goal of this study was to biomechanically compare headless compression screws made from titanium with a biodegradable equivalent made from a magnesium alloy. METHODS: This biomechanical in vitro study was conducted on 13 pairs of fresh-frozen human cadaveric humeri, in which a standardized Bryan-Morrey type I fracture was fixed using 2 magnesium screws (MSs) or 2 TSs. First, construct stiffness was measured during 10 cycles of static loading between 10 and 50 N. Second, continuous loading was applied at 4 Hz between 10 and 50 N, increasing the maximum load every 10,000 cycles by 25 N until construct failure occurred. This was defined by fragment displacement >3 mm. RESULTS: Comparison of the 2 screw types showed no differences related to construct stiffness (0.50 ± 0.25 kN/mm in MS group and 0.47 ± 0.13 kN/mm in TS group, P = .701), failure cycle (43,944 ± 21,625 and 41,202 ± 16,457, respectively; P = .701), and load to failure (152 ± 53 N and 150 ± 42 N, respectively; P = .915). CONCLUSION: Biomechanical comparison showed that simple capitellar fractures are equally stabilized by headless compression screws made from titanium or a biodegradable magnesium alloy. Therefore, in view of the advantages of biodegradable implants for transcartilaginous fracture stabilization, their clinical application should be considered and evaluated.


Subject(s)
Bone Screws , Fracture Fixation, Internal/instrumentation , Humeral Fractures/surgery , Magnesium , Titanium , Absorbable Implants , Aged , Aged, 80 and over , Biomechanical Phenomena , Humans , Male , Middle Aged
10.
Scand J Trauma Resusc Emerg Med ; 28(1): 42, 2020 May 24.
Article in English | MEDLINE | ID: mdl-32448190

ABSTRACT

BACKGROUND: Major trauma often comprises fractures of the thoracolumbar spine and these are often accompanied by relevant thoracic trauma. Major complications can be ascribed to substantial simultaneous trauma to the chest and concomitant immobilization due to spinal instability, pain or neurological dysfunction, impairing the respiratory system individually and together. Thus, we proposed that an early stabilization of thoracolumbar spine fractures will result in significant benefits regarding respiratory organ function, multiple organ failure and length of ICU / hospital stay. METHODS: Patients documented in the TraumaRegister DGU®, aged ≥16 years, ISS ≥ 16, AISThorax ≥ 3 with a concomitant thoracic and / or lumbar spine injury severity (AISSpine) ≥ 3 were analyzed. Penetrating injuries and severe injuries to head, abdomen or extremities (AIS ≥ 3) led to patient exclusion. Groups with fractures of the lumbar (LS) or thoracic spine (TS) were formed according to the severity of spinal trauma (AISspine): AISLS = 3, AISLS = 4-5, AISTS = 3 and AISTS = 4-5, respectively. RESULTS: 1740 patients remained for analysis, with 1338 (76.9%) undergoing spinal surgery within their hospital stay. 976 (72.9%) had spine surgery within the first 72 h, 362 (27.1%) later on. Patients with injuries to the thoracic spine (AISTS = 3) or lumbar spine (AISLS = 3) significantly benefit from early surgical intervention concerning ventilation time (AISLS = 3 only), ARDS, multiple organ failure, sepsis rate (AISTS = 3 only), length of stay in the intensive care unit and length of hospital stay. In multiple injured patients with at least severe thoracic spine trauma (AISTS ≥ 4) early surgery showed a significantly shorter ventilation time, decreased sepsis rate as well as shorter time spend in the ICU and in hospital. CONCLUSIONS: Multiply injured patients with at least serious thoracic trauma (AISThorax ≥ 3) and accompanying spine trauma can significantly benefit from early spine stabilization within the first 72 h after hospital admission. Based on the presented data, primary spine surgery within 72 h for fracture stabilization in multiply injured patients with leading thoracic trauma, especially in patients suffering from fractures of the thoracic spine, seems to be beneficial.


Subject(s)
Multiple Trauma/therapy , Spinal Fractures/therapy , Thoracic Injuries/therapy , Adult , Aged , Critical Care , Female , Humans , Injury Severity Score , Length of Stay , Lumbar Vertebrae/injuries , Male , Middle Aged , Multiple Trauma/complications , Registries , Spinal Fractures/complications , Thoracic Injuries/complications , Thoracic Vertebrae/injuries , Time-to-Treatment
11.
Injury ; 51(6): 1281-1287, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32197829

ABSTRACT

PURPOSE: To date, surgically treated multifragmentary patellar fractures are still associated with high rates of complications, such as i.e. secondary fracture displacement. Osteosynthesis is most frequently performed with screws and cerclages. To increase primary stability, locking plates have been introduced. However, there is still a lack of biomechanical data supporting the superiority of plate fixation compared to screw fixation with cerclages in these cases. The goal of the present study was to conduct biomechanical comparison of these two techniques under dynamic loading conditions. METHODS: A standardized 34-C3 fracture was created in eight pairs of human cadaveric knee joints. Following a randomization protocol, they were fixed with a 3.5 mm anterior locking plate (LP) or cannulated screws with anterior tension band wiring (hybrid osteosynthesis, HO).Subsequently, all constructs were tested for 100 cycles from 90° of knee-flexion to full extension by applying a pulling force to the quadriceps tendon. Outcome parameters were fracture displacement after one cycle, after 100 cycles and implant loosening. Failure was defined as fracture displacement > 2 mm. RESULTS: Biomechanical testing showed significantly less fracture displacement following LP compared to HO both after the first (p = 0.042) and after 100 cycles (p = 0.025). The difference in loosening was significant as well (p = 0.017). Following HO, 5/8 constructs failed during cyclic loading. There was no failure in the LP group. In the HO group, loosening correlated with bone mineral density (R = - 0.857) which was not observed in the LP group (R = - 0.429). CONCLUSION: Anterior locking plate osteosynthesis of comminuted patellar fractures biomechanically provides better primary stability compared to cannulated screws with anterior tension band wiring.


Subject(s)
Bone Plates , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Fractures, Comminuted/surgery , Patella/surgery , Biomechanical Phenomena , Bone Density , Bone Screws , Bone Wires , Cadaver , Humans , Materials Testing , Patella/injuries , Range of Motion, Articular , Stress, Mechanical , Tensile Strength
12.
J Orthop Surg Res ; 15(1): 27, 2020 Jan 23.
Article in English | MEDLINE | ID: mdl-31973761

ABSTRACT

BACKGROUND: Arthrofibrosis is a painful and restraining complication that occurs after about 10% of total knee arthroplasty and cruciate ligament surgery. The pathogenesis of arthrofibrosis has not yet been fully understood. Stress signals stimulate immune cells, and fibroblast differentiates into myofibroblast, which produce a large amount of collagen. Xylosyltransferases also appear to be involved in these pathways. They catalyze proteoglycan biosynthesis, which is involved in tissue remodeling and myofibroblast differentiation. The aim of this study was to investigate the relationship between the disease arthrofibrosis and the expression of the two isoforms of xylosyltransferases I and II. METHODS: Tissue samples from 14 patients with arthrofibrosis were compared with tissue samples from seven healthy controls. The xylosyltransferases were detected by immunohistochemistry. The tissues were divided into four different areas of interest: vessels, synovialis, cell-poor and cell-rich fibrosis, or cell-poor and cell-rich areas in the control group. A quantification of the results was performed by modification of the immunoreactive score according to Remmele and Stegner. RESULTS: Xylosyltransferase I was expressed in the various tissue types at varying rates. Xylosyltransferase I expression was considerably and significantly stronger than that of xylosyltransferase II. The following sequences of xylosyltransferase I and xylosyltransferase II expression were determined as follows: vessels >> cell-rich fibrosis > cell-poor fibrosis > synovialis. A positive correlation between the number of positive fibroblasts and the immunoreactive scoring system (IRS) was documented. CONCLUSIONS: The significant positive correlation of xylosyltransferase -I expression with increasing number of fibroblasts demonstrates a high myofibroblast differentiation rate, which implies a gradual event as the pathogenesis of arthrofibrosis.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Pentosyltransferases/metabolism , Postoperative Complications/enzymology , Adult , Case-Control Studies , Female , Fibrosis , Humans , Male , Postoperative Complications/etiology , Postoperative Complications/pathology , Synovial Membrane/pathology , UDP Xylose-Protein Xylosyltransferase
13.
Knee Surg Sports Traumatol Arthrosc ; 28(3): 759-766, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31055609

ABSTRACT

PURPOSE: Accurate femoral tunnel placement is of great importance during medial patellofemoral ligament (MPFL) reconstruction. Purpose of the present study was to investigate the influence of trochlear dysplasia on the accuracy of fluoroscopic guided femoral tunnel placement. METHODS: CT-Scans of 30 knees (five with regular shaped trochlea, 10 with a Type A and five each with a Type B, C, or D trochlear dysplasia) were imported into the image analysis platform MeVisLab. A 3D Bone Volume Rendering (VR) and a virtual lateral radiograph was created. The anatomic femoral MPFL insertion was identified on the 3D VR. On virtual lateral radiographs, the MPFL insertion was identified based on landmarks described by Schöttle et al. using three different perspectives: Best possible overlap of the femoral condyles (BC) and a tangent along posterior border of the posterior femoral cortex (pBC); a tangent along the anterior border of the posterior cortex (aBC); and best possible overlap of the distal part of the posterior femoral cortex (BF). Distances between the anatomic attachment and radiographically obtained insertions were measured on the 3D VR and compared according to the type of trochlear dysplasia. RESULTS: Significantly lower accuracy of fluoroscopy guided tunnel placement in MPFL reconstruction was found in knees with Type C and D dysplasia. This effect was observed irrespectively from the radiologic perspective (pBC, aBC, and FC). In the pBC view (highest accuracy), the mean distance from the centre of the anatomic MPFL attachment to the radiographically defined location was 4.3 mm in knees without trochlear dysplasia and increased to 4.8 mm in knees with Type A dysplasia, 3.8 mm in knees with Type B dysplasia, 6.7 mm (p < 0.001) in knees with Type C dysplasia, and 7.3 mm (p < 0.001) in knees with Type D dysplasia. CONCLUSION: Radiographic landmark-based femoral tunnel placement in the pBC view provides highest accuracy in knees with a normal shaped trochlea or low grade trochlear dysplasia. In patients with severe dysplasia, fluoroscopy guided tunnel placement has a low accuracy, exceeding a critical threshold of 5 mm distance to the anatomic MPFL insertion irrespective of the radiographic perspective. In these patients, utilization of anatomic landmarks may be beneficial. LEVEL OF EVIDENCE: IV.


Subject(s)
Femur/diagnostic imaging , Femur/surgery , Fluoroscopy , Ligaments, Articular/diagnostic imaging , Ligaments, Articular/surgery , Patellofemoral Joint/diagnostic imaging , Patellofemoral Joint/surgery , Adult , Anatomic Landmarks , Female , Femur/pathology , Fluoroscopy/methods , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Patellofemoral Joint/pathology , Tomography, X-Ray Computed
14.
Z Orthop Unfall ; 158(6): 611-617, 2020 Dec.
Article in English, German | MEDLINE | ID: mdl-31820431

ABSTRACT

INTRODUCTION: Ankle fusion is still considered as an established therapy for end-stage ankle osteoarthritis. To determine exact description of postoperative functioning, it is necessary to consult a variety of functional scores and quality of life questionnaires. METHODS/PATIENTS: 34 patients with 34 ankle fusions were investigated on average 5.9 years postoperatively by functional tests and health-related quality of life questionnaires (AOFAS hindfoot score [AOFAS: American Orthopaedic Foot/Ankle Society], Foot Function Index [FFI], Lower Extremity Functional Scale [LEFS], Lower Extremity Activity Scale [LEAS], Visual Analogue Scale Foot/Ankle Surgery [VAS FA], Short Form 36 [SF-36], EuroQol 5D [EQ-5D]). RESULTS: After ankle fusion: the majority of cases gain pain reduction, but residual symptoms may persist; the maximum walking distance (subjectively more than objectively) will be extended; rarely walking without any aids can be achieved; in most cases, the gait pattern is only slightly changed; the re-entry into working life is often possible; climbing stairs without any restrictions is not always possible; the psychological situation will be equalized with that of healthy people. CONCLUSION: The results of the study confirm the success rates of ankle fusions in the majority of cases. Well defined limitations and residual symptoms can be named on the basis of the available data.


Subject(s)
Ankle , Quality of Life , Ankle Joint/surgery , Arthrodesis , Humans , Physical Functional Performance , Treatment Outcome
15.
Proc Inst Mech Eng H ; 234(1): 74-80, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31702442

ABSTRACT

For radial head osteosynthesis, biodegradable implants are gaining in importance to minimize cartilage destruction and implant impingement and to supersede implant removal. Since loss of reduction and pseudarthrosis remain challenging complications, new implants should at least provide comparable biomechanical properties as commonly used metal implants. The objective of this study was to compare the treatment by polylactide pins to titanium screws and to quantify the produced cartilage defects. Eight pairs of human cadaver radii with a standardized Mason type II fracture were stabilized either by two 2.0-mm polylactide pins or titanium screws. The produced cartilage defects were quantified using an image analyzing software. Quasi-static loading was performed axially and transversally for 10 cycles each between 10 and 50 N. Afterward, implant loosening was tested by axial loading up to 10,000 cycles, followed by load to failure testing. Polylactide pins showed less construct stiffness under axial (p = 0.017) and transversal (p = 0.012) loading, and one polylactide pins construct failed after two cycles of transversal loading. At axial loading, a high correlation between bone mineral density and construct stiffness was observed among polylactide pins (R = 0.667; p = 0.071), which was not seen among titanium screws (R = 0.262; p = 0.531). No difference in implant loosening was recorded after 10,000 cycles (p = 0.237); however, one polylactide pins construct failed after 30 cycles and failure loads were higher for titanium screws (p=0.017). Polylactide pin produced smaller cartilage defects (p=0.012). In conclusion, simple radial head fractures treated by polylactide pins show less biomechanical stability than treated by titanium screws, particularly in osteoporotic bone which might lead to secondary loss of reduction. Due to smaller cartilage defects and equal properties under continuous loading, polylactide pins might represent a gentle alternative in patients with good bone quality making subsequent implant removal redundant.


Subject(s)
Bone Nails , Bone Screws , Craniocerebral Trauma/surgery , Fractures, Bone/surgery , Mechanical Phenomena , Titanium/metabolism , Biomechanical Phenomena , Craniocerebral Trauma/metabolism , Fractures, Bone/metabolism , Materials Testing
16.
PLoS One ; 14(10): e0224080, 2019.
Article in English | MEDLINE | ID: mdl-31648233

ABSTRACT

High tibial medial open-wedge osteotomy (HTO) is an established treatment option for cartilage lesions in the medial compartment. It was this study's aim to evaluate the effect of asymptomatic single or kissing lesions in the lateral compartment on functional outcome after medial open-wedge osteotomy. A total of 156 patients were enrolled in this retrospective study. All patients underwent HTO due to a varus deformity and a symptomatic cartilage lesion or osteoarthritis in the medial compartment. We acquired preoperative Lysholm and VAS Scores. Each open-wedge osteotomy was preceded by diagnostic arthroscopy to ensure the compartments were thoroughly documented and diagnosed. Cartilage lesions in the lateral compartment were evaluated, and three groups created according to their individual characteristics: group A (no cartilage lesion, n = 119), group B (single cartilage lesion, n = 16) and group C (kissing lesions, n = 21). Cartilage lesions were graded according to the Outerbridge classification, The functional postoperative outcome was determined by relying on several parameters (VAS Score, Lysholm, KOOS, WOMAC Score). Pre- and postoperative long-leg axis views were analyzed via special planning software (mediCAD, Hectec GmbH Germany). Mean follow-up was at 69.0 ± 30.3 months after surgery (range 22 to 121 months). There were no significant differences between the three groups in the correction angle chosen (p = 0.16). Regarding the outcome parameters, group A attained the best results in the WOMACpain Score (p = 0.03) and WOMACfunction Score (p = 0.05). A higher Outerbridge-Score of cartilage lesions in the lateral compartment was associated with a higher (i.e., worse) WOMACpain Score (p = 0.018) and WOMACfunction Score (p = 0.033). In all the groups (A, B, and C), HTO led to a significant improvement in the Lysholm Score (p < 0.001) and to a decrease in pain level (VAS Score; p < 0.001). Conclusion: Valgus high tibial osteotomy leads to reduced pain and improved functional outcome scores, even in patients with pre-existing asymptomatic single or corresponding cartilage lesions in the lateral compartment. In case of severe cartilage lesions in the lateral compartment, surgeons should consider that clinical outcome worsens depending on the Outerbridge Score.


Subject(s)
Cartilage, Articular/pathology , Osteoarthritis/surgery , Osteotomy/methods , Recovery of Function , Adult , Cartilage, Articular/surgery , Female , Humans , Male , Middle Aged , Osteoarthritis/pathology , Retrospective Studies , Treatment Outcome
17.
Geriatr Orthop Surg Rehabil ; 10: 2151459319872941, 2019.
Article in English | MEDLINE | ID: mdl-31523475

ABSTRACT

INTRODUCTION: This study investigates the management of hip fractures in a German maximum care hospital and compares these data to evidence-based standard and practice in 180 hospitals participating in the UK National Hip Fracture Database (NHFD) and 16 hospitals participating in the Irish Hip Fracture Database (IHFD). This is the first study directly comparing the management of hip fractures between 3 separate health-care systems within Europe. METHODS: Electronic medical data were collected retrospectively describing the care pathway of elderly patients with a hip fracture admitted to a large trauma unit in the south of Germany "University Hospital Freiburg" (UHF). The audit evaluated demographics, postoperative outcome, and the adherence to the 6 "Blue Book" standards of care. These data were directly compared with the data from the UK NHFD and the IHFD acquired from 180 and 16 hospitals, respectively. RESULTS: At 36 hours, 95.8% of patients had received surgery in UHF, compared to 71.5% in the NHFD and 58% of patients in the IHFD. The rate of in-hospital mortality was 4.7% compared to 7.1% in the NHFD and 5% in the IHFD. The mean average acute length of stay was 13.4 days compared to 16.4 days in the NHFD and 20 days in the IHFD. Reoperation rates are 3.3% compared to 1% in the NHFD and 1.1% in the IHFD; 50.5% of patients were discharged on bone protection medication, compared to 47% in the IHFD and 79.3% in the UK NHFD. DISCUSSION: Despite uniformly acknowledged evidence-based treatment guidelines, the management of hip fractures remains heterogeneous within Europe. CONCLUSION: These data show that different areas of the hip fracture care pathway in Germany, England, and Ireland, respectively, show room for improvement in light of the growing socioeconomic burden these countries are expected to face.

18.
JBJS Case Connect ; 9(3): e0086, 2019.
Article in English | MEDLINE | ID: mdl-31469667

ABSTRACT

CASE: A 38-year-old man presented with recurrent chondroblastoma of the acromion after primary curettage and bone grafting. The patient underwent revision surgery with resection of the acromion and reconstruction using an autologous iliac crest graft. He had regained normal shoulder function without recurrence at a follow-up of 17 months. CONCLUSIONS: This case demonstrates a rare location of chondroblastoma and successful anatomical and functional reconstruction. The described surgical procedure could be considered for large tumorous lesions of the acromion, for which curettage would be insufficient, and to preserve and reconstruct a functionally intact shoulder girdle.


Subject(s)
Acromion/surgery , Bone Neoplasms/surgery , Bone Transplantation/methods , Chondroblastoma/surgery , Neoplasm Recurrence, Local/surgery , Adult , Bone Neoplasms/diagnostic imaging , Chondroblastoma/diagnostic imaging , Humans , Ilium/transplantation , Male , Neoplasm Recurrence, Local/diagnostic imaging
19.
Proc Inst Mech Eng H ; 233(7): 706-711, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31064313

ABSTRACT

The aim of this study was the dynamic biomechanical evaluation of a ready-to-use oil-based calcium phosphate cement paste implanted to augment intramedullary nail fixation of a three-part humeral head fracture model. Fractures in the osteoporotic bone are often fractures of the proximal humerus. Secondary fracture displacements due to cut-out in osteoporotic bone have been observed in up to 13% of cases. Procedures have been developed to augment fracture fixation with polymethylmethacrylate to increase stability, but there are still unsolved challenges relating to its material-specific properties. Calcium phosphate cement could be a biological alternative in the augmentation of osteoporotic fractures because of its more favourable material properties. Fracture fixation was performed on eight pairs of human cadaveric bones to stabilize a standardized three-part humeral head fracture model by implantation of the Targon® PH (Braun-Aesculap AG, Tuttlingen, Germany) intramedullary nail and insertion of three head screws and two bicortical shaft screws. The procedure was randomized, and one bone of each pair received calcium phosphate cement augmentation. Custom-made cannulated screws with an open lateral slot facilitated augmentation, making it possible to cement the threaded portion of the screw (1-mL calcium phosphate cement/screw). After the calcium phosphate cement had hardened, the humeri were subjected to dynamic axial loading. Load was progressively increased, monitored by ultrasound-based motion analysis, and total deformation was recorded. Load testing continued until implant failure. The augmented group withstood significantly more cycles before implant failure. The average initial stiffness showed a significant difference between the two study groups. Ultrasonic sensor technology was used to measure angular displacement during testing and a significant difference was found. Calcium phosphate cement offers a potential alternative to implant augmentation in the treatment of osteoporotic humeral head fractures. Future studies are required to confirm these observations clinically in vivo.


Subject(s)
Bone Cements , Calcium Phosphates , Fracture Fixation, Intramedullary/methods , Humeral Fractures/surgery , Materials Testing , Mechanical Phenomena , Aged , Biomechanical Phenomena , Female , Humans , Male
20.
J Magn Reson Imaging ; 50(5): 1561-1570, 2019 11.
Article in English | MEDLINE | ID: mdl-30903682

ABSTRACT

BACKGROUND: Higher-resolution MRI of the patellofemoral cartilage under loading is hampered by subject motion since knee flexion is required during the scan. PURPOSE: To demonstrate robust quantification of cartilage compression and contact area changes in response to in situ loading by means of MRI with prospective motion correction and regularized image postprocessing. STUDY TYPE: Cohort study. SUBJECTS: Fifteen healthy male subjects. FIELD STRENGTH: 3 T. SEQUENCE: Spoiled 3D gradient-echo sequence augmented with prospective motion correction based on optical tracking. Measurements were performed with three different loads (0/200/400 N). ASSESSMENT: Bone and cartilage segmentation was performed manually and regularized with a deep-learning approach. Average patellar and femoral cartilage thickness and contact area were calculated for the three loading situations. Reproducibility was assessed via repeated measurements in one subject. STATISTICAL TESTS: Comparison of the three loading situations was performed by Wilcoxon signed-rank tests. RESULTS: Regularization using a deep convolutional neural network reduced the variance of the quantified relative load-induced changes of cartilage thickness and contact area compared to purely manual segmentation (average reduction of standard deviation by ∼50%) and repeated measurements performed on the same subject demonstrated high reproducibility of the method. For the three loading situations (0/200/400 N), the patellofemoral cartilage contact area as well as the mean patellar and femoral cartilage thickness were significantly different from each other (P < 0.05). While the patellofemoral cartilage contact area increased under loading (by 14.5/19.0% for loads of 200/400 N), patellar and femoral cartilage thickness exhibited a load-dependent thickness decrease (patella: -4.4/-7.4%, femur: -3.4/-7.1% for loads of 200/400 N). DATA CONCLUSION: MRI with prospective motion correction enables quantitative evaluation of patellofemoral cartilage deformation and contact area changes in response to in situ loading. Regularizing the manual segmentations using a neural network enables robust quantification of the load-induced changes. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1561-1570.


Subject(s)
Cartilage/diagnostic imaging , Image Processing, Computer-Assisted/methods , Knee/diagnostic imaging , Patellofemoral Joint/diagnostic imaging , Adult , Healthy Volunteers , Humans , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Male , Motion , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...