Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-24111378

ABSTRACT

Obstructive sleep apnea (OSA) is a common sleep disorder that causes increasing risk of mortality and affects quality of life of approximately 6.62% of the total US population. Timely detection of sleep apnea events is vital for the treatment of OSA. In this paper, we present a novel approach based on extracting the quantifiers of nonlinear dynamic cardio-respiratory coupling from electrocardiogram (ECG) signals to detect sleep apnea events. The quantifiers of the cardio-respiratory dynamic coupling were extracted based on recurrence quantification analysis (RQA), and a battery of statistical data mining techniques were to enhance OSA detection accuracy. This approach would lead to a cost-effective and convenient means for screening of OSA, compared to traditional polysomnography (PSG) methods. The results of tests conducted using data from PhysioNets Sleep Apnea database suggest excellent quality of the OSA detection based on a thorough comparison of multiple models, using model selection criteria of validation data: Sensitivity (91.93%), Specificity (85.84%), Misclassification (11.94%) and Lift (2.7).


Subject(s)
Electrocardiography , Sleep Apnea, Obstructive/diagnosis , Algorithms , Data Mining , Databases, Factual , Humans , Nonlinear Dynamics , Sensitivity and Specificity , Signal-To-Noise Ratio
2.
Sensors (Basel) ; 12(8): 10851-70, 2012.
Article in English | MEDLINE | ID: mdl-23112633

ABSTRACT

This paper presents the design and testing of a wireless sensor system developed using a Microchip PICDEM developer kit to acquire and monitor human heart sounds for phonocardiography applications. This system can serve as a cost-effective option to the recent developments in wireless phonocardiography sensors that have primarily focused on Bluetooth technology. This wireless sensor system has been designed and developed in-house using off-the-shelf components and open source software for remote and mobile applications. The small form factor (3.75 cm × 5 cm × 1 cm), high throughput (6,000 Hz data streaming rate), and low cost ($13 per unit for a 1,000 unit batch) of this wireless sensor system make it particularly attractive for phonocardiography and other sensing applications. The experimental results of sensor signal analysis using several signal characterization techniques suggest that this wireless sensor system can capture both fundamental heart sounds (S1 and S2), and is also capable of capturing abnormal heart sounds (S3 and S4) and heart murmurs without aliasing. The results of a denoising application using Wavelet Transform show that the undesirable noises of sensor signals in the surrounding environment can be reduced dramatically. The exercising experiment results also show that this proposed wireless PCG system can capture heart sounds over different heart conditions simulated by varying heart rates of six subjects over a range of 60-180 Hz through exercise testing.


Subject(s)
Phonocardiography/instrumentation , Phonocardiography/methods , Telemedicine/instrumentation , Wireless Technology/instrumentation , Humans , Wavelet Analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...