Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Micromachines (Basel) ; 14(12)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38138371

ABSTRACT

Microchannels with curved geometries have been employed for many applications in microfluidic devices in the past decades. The Dean vortices generated in such geometries have been manipulated using different methods to enhance the performance of devices in applications such as mixing, droplet sorting, and particle/cell separation. Understanding the effect of the manipulation method on the Dean vortices in different geometries can provide crucial information to be employed in designing high-efficiency microfluidic devices. In this review, the physics of Dean vortices and the affecting parameters are summarized. Various Dean number calculation methods are collected and represented to minimize the misinterpretation of published information due to the lack of a unified defining formula for the Dean dimensionless number. Consequently, all Dean number values reported in the references are recalculated to the most common method to facilitate comprehension of the phenomena. Based on the converted information gathered from previous numerical and experimental studies, it is concluded that the length of the channel and the channel pathline, e.g., spiral, serpentine, or helix, also affect the flow state. This review also provides a detailed summery on the effect of other geometric parameters, such as cross-section shape, aspect ratio, and radius of curvature, on the Dean vortices' number and arrangement. Finally, considering the importance of droplet microfluidics, the effect of curved geometry on the shape, trajectory, and internal flow organization of the droplets passing through a curved channel has been reviewed.

2.
PLoS One ; 15(10): e0239604, 2020.
Article in English | MEDLINE | ID: mdl-33044976

ABSTRACT

Demand for heart transplants far exceeds supply of donated organs. This is attributed to the high percentage of donor hearts that are discarded and to the narrow six-hour time window currently available for transplantation. Ex-vivo heart perfusion (EVHP) provides the opportunity for resuscitation of damaged organs and extended transplantation time window by enabling functional assessment of the hearts in a near-physiologic state. Present work investigates the fluid mechanics of the ex-vivo flow loop and corresponding impact on cardiac performance. A mechanical flow loop is developed that is analogous to the region of the EVHP system that mimics in-vivo systemic circulation, including the body's largest and most compliant artery, the aorta. This investigation is focused on determining the effect of mock aortic tubing compliance on pump performance. A custom-made silicone mock aorta was developed to simulate a range of in-vivo conditions and a physiological flow was generated using a commercial ventricular assist device (VAD). Monitored parameters, including pressure, tube distension and downstream velocity, acquired using time-resolved particle imaging velocimetry (PIV), were applied to an unsteady Bernoulli analysis of the flow in a novel way to evaluate pump performance as a proxy for cardiac workload. When compared to the rigid case, the compliant mock aorta case demonstrated healthier physiologic pressure waveforms, steadier downstream flow and reduced energetic demands on the pump. These results provide experimental verification of Windkessel theory and support the need for a compliant mock aorta in the EVHP system.


Subject(s)
Aorta/physiology , Heart Transplantation/methods , Models, Cardiovascular , Compliance , Extracorporeal Circulation , Heart-Assist Devices , Hemodynamics , Humans , In Vitro Techniques , Organ Preservation/instrumentation , Organ Preservation/methods , Perfusion/instrumentation , Perfusion/methods , Tissue Donors , Tissue and Organ Procurement
SELECTION OF CITATIONS
SEARCH DETAIL