1.
Rev Sci Instrum ; 78(10): 103109, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17979408

ABSTRACT

This article describes the design, characterization, and performance of an electrostatic glass actuator adapted to an ultrahigh vacuum environment (10(-8) mbar). The three-phase rotary motor is used to drive a turbine that acts as a velocity-selective light trap for a slow continuous beam of laser-cooled atoms. This simple, compact, and nonmagnetic device should find applications in the realm of time and frequency metrology, as well as in other areas of atomic, molecular physics and elsewhere.


Subject(s)
Glass , Lasers , Micromanipulation/instrumentation , Specimen Handling/instrumentation , Specimen Handling/methods , Cold Temperature , Equipment Design , Equipment Failure Analysis , Micromanipulation/methods , Reproducibility of Results , Rotation , Sensitivity and Specificity , Static Electricity , Vacuum
2.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 6199-202, 2005.
Article in English | MEDLINE | ID: mdl-17281681

ABSTRACT

This paper is related to the measurements of the modulus of elasticity of an artery by studying the deformations due to the inflation of an angioplasty balloon catheter used for Interventional Radiology (IR) procedures. Various types of balloons are studied in order to characterize and compare their behaviors at the time of inflation. A test bench, consisting of an angioplasty balloon, a Polyvinyl alcohol model and an actuator used to inflate a balloon, is developed for the realization of the experiments. The pressure-volume curve during the inflation of a balloon is observed. Elasticity modulus are derived with an analytical model of the measurement system. The results are then analyzed and compared to existing data from literature.

3.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 2615-8, 2005.
Article in English | MEDLINE | ID: mdl-17282774

ABSTRACT

This paper presents a novel method for measurements of internal constraints during an Interventional Radiology procedure. Fiber-optic strain gauge, operating as a Fabry-Perot interferometer, is inserted and navigated inside a polyvinyl alcohol (PVA) model. The information obtained from deformation of the Fabry-Perot cavity is analyzed and the results are then rescaled through a calibration procedure for catheters. The measures help to locate the maximum interaction forces between catheter and blood vessel wall at approximately 1.3 N and to observe the shape of dynamic interaction during manipulation.