Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Diagnostics (Basel) ; 13(18)2023 Sep 14.
Article in English | MEDLINE | ID: mdl-37761317

ABSTRACT

Angiography is a very informative method for physicians such as cardiologists, neurologists and neuroscientists. The current modalities experience some shortages, e.g., ultrasound is very operator dependent. The computerized tomography (CT) and magnetic resonance (MR) angiography are very expensive and near infrared spectroscopy cannot capture the deep arteries. Microwave technology has the potential to address some of these issues while compromising between operator dependency, cost, speed, penetration depth and resolution. This paper studies the feasibility of microwave signals for monitoring of arteries. To this aim, a homogenous phantom mimicking body tissue is built. Four elastic tubes simulate arteries and a mechanical system creates pulsations in these arteries. A multiple input multiple output (MIMO) array of ultra-wideband (UWB) transmitters and receivers illuminates the phantom and captures the reflected signals over the desired observation time period. Since we are only interested in the imaging of dynamic parts, i.e., arteries, the static clutters can be suppressed easily by background subtraction method. To obtain a fast image of arteries, which are pulsating with the heartbeat rate, we calculate the Fourier transform of each channel of the MIMO system over the observation time and apply delay and sum (DAS) beamforming method on the heartbeat rate aligned spectral component. The results show that the lateral and longitudinal images and motion mode (M-mode) time series of different points of phantom have the potential to be used for diagnosis.

2.
Sensors (Basel) ; 23(5)2023 Feb 23.
Article in English | MEDLINE | ID: mdl-36904658

ABSTRACT

In this article, we propose an evolved system design approach to ultra-wideband (UWB) radar based on pseudo-random noise (PRN) sequences, the key features of which are its user-adaptability to meet the demands provided by desired microwave imaging applications and its multichannel scalability. In light of providing a fully synchronized multichannel radar imaging system for short-range imaging as mine detection, non-destructive testing (NDT) or medical imaging, the advanced system architecture is presented with a special focus put on the implemented synchronization mechanism and clocking scheme. The core of the targeted adaptivity is provided by means of hardware, such as variable clock generators and dividers as well as programmable PRN generators. In addition to adaptive hardware, the customization of signal processing is feasible within an extensive open-source framework using the Red Pitaya® data acquisition platform. A system benchmark in terms of signal-to-noise ratio (SNR), jitter, and synchronization stability is conducted to determine the achievable performance of the prototype system put into practice. Furthermore, an outlook on the planned future development and performance improvement is provided.

3.
Sensors (Basel) ; 21(19)2021 Oct 04.
Article in English | MEDLINE | ID: mdl-34640933

ABSTRACT

Magnetic nanoparticles have been investigated for microwave imaging over the last decade. The use of functionalized magnetic nanoparticles, which are able to accumulate selectively within tumorous tissue, can increase the diagnostic reliability. This paper deals with the detecting and imaging of magnetic nanoparticles by means of ultra-wideband microwave sensing via pseudo-noise technology. The investigations were based on phantom measurements. In the first experiment, we analyzed the detectability of magnetic nanoparticles depending on the magnetic field intensity of the polarizing magnetic field, as well as the viscosity of the target and the surrounding medium in which the particles were embedded, respectively. The results show a nonlinear behavior of the magnetic nanoparticle response depending on the magnetic field intensity for magnetic nanoparticles diluted in distilled water and for magnetic nanoparticles embedded in a solid medium. Furthermore, the maximum amplitude of the magnetic nanoparticles responses varies for the different surrounding materials of the magnetic nanoparticles. In the second experiment, we investigated the influence of the target position on the three-dimensional imaging of the magnetic nanoparticles in a realistic measurement setup for breast cancer imaging. The results show that the magnetic nanoparticles can be detected successfully. However, the intensity of the particles in the image depends on its position due to the path-dependent attenuation, the inhomogeneous microwave illumination of the breast, and the inhomogeneity of the magnetic field. Regarding the last point, we present an approach to compensate for the inhomogeneity of the magnetic field by computing a position-dependent correction factor based on the measured magnetic field intensity and the magnetic susceptibility of the magnetic particles. Moreover, the results indicate an influence of the polarizing magnetic field on the measured ultra-wideband signals even without magnetic nanoparticles. Such a disturbing influence of the polarizing magnetic field on the measurements should be reduced for a robust magnetic nanoparticles detection. Therefore, we analyzed the two-state (ON/OFF) and the sinusoidal modulation of the external magnetic field concerning the detectability of the magnetic nanoparticles with respect to these spurious effects, as well as their practical application.


Subject(s)
Magnetite Nanoparticles , Microwaves , Humans , Imaging, Three-Dimensional , Magnetics , Reproducibility of Results
4.
Sensors (Basel) ; 21(17)2021 Aug 26.
Article in English | MEDLINE | ID: mdl-34502626

ABSTRACT

Microwave sensors have recently been introduced as high-temporal resolution sensors, which could be used in the contactless monitoring of artery pulsation and breathing. However, accurate and efficient signal processing methods are still required. In this paper, the matrix pencil method (MPM), as an efficient method with good frequency resolution, is applied to back-reflected microwave signals to extract vital signs. It is shown that decomposing of the signal to its damping exponentials fulfilled by MPM gives the opportunity to separate signals, e.g., breathing and heartbeat, with high precision. A publicly online dataset (GUARDIAN), obtained by a continuous wave microwave sensor, is applied to evaluate the performance of MPM. Two methods of bandpass filtering (BPF) and variational mode decomposition (VMD) are also implemented. In addition to the GUARDIAN dataset, these methods are also applied to signals acquired by an ultra-wideband (UWB) sensor. It is concluded that when the vital sign is sufficiently strong and pure, all methods, e.g., MPM, VMD, and BPF, are appropriate for vital sign monitoring. However, in noisy cases, MPM has better performance. Therefore, for non-contact microwave vital sign monitoring, which is usually subject to noisy situations, MPM is a powerful method.


Subject(s)
Microwaves , Radar , Algorithms , Signal Processing, Computer-Assisted , Vital Signs
5.
Sensors (Basel) ; 19(7)2019 Apr 10.
Article in English | MEDLINE | ID: mdl-30974770

ABSTRACT

The knowledge of frequency and temperature dependent dielectric properties of tissue is essential to develop ultra-wideband diagnostic technologies, such as a non-invasive temperature monitoring system during hyperthermia treatment. To this end, we characterized the dielectric properties of animal liver, muscle, fat and blood in the microwave frequency range from 0.5 GHz to 7 GHz and in the temperature range between 30 °C and 50 °C. The measured data were modeled to a two-pole Cole-Cole model and a second-order polynomial was introduced to fit the Cole-Cole parameters as a function of temperature. The parametric model provides access to the dielectric properties of tissue at any frequency and temperature in the specified range.


Subject(s)
Blood/radiation effects , Dielectric Spectroscopy , Microwaves , Temperature , Algorithms , Animals , Electric Impedance , Fats/radiation effects , Humans , Liver/physiology , Liver/radiation effects , Models, Biological , Muscles/physiology , Muscles/radiation effects , Swine
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2018: 5386-5389, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30441554

ABSTRACT

Non-invasive differential temperature monitoring by means of ultra-wideband sensing is a promising approach concerning temperature controlling during thermotherapy. In this paper the principal of temperature difference detection by UWB radar is explained and appropriate phantom measurements are discussed. In a first step, temperature dependent dielectric properties of the phantom materials (sunflower oil and distilled water) are analyzed. Subsequently, temperature dependent phantom measurements are conducted where the temperature dependent signal changes of the received UWB signals are investigated. Results show a linear behavior between the received differential radar signals and the temperature differences of the target in the considered temperature range. Furthermore, investigations show that temperature changes of the target, which are common in thermal therapy (e.g., hyperthermia), are detectable by means of UWB radar.


Subject(s)
Hyperthermia, Induced , Microwaves , Radar , Temperature , Humans , Phantoms, Imaging
7.
Sensors (Basel) ; 18(7)2018 Jul 03.
Article in English | MEDLINE | ID: mdl-29970835

ABSTRACT

Wideband microwave imaging is of interest wherever optical opaque scenarios need to be analyzed, as these waves can penetrate biological tissues, many building materials, or industrial materials. One of the challenges of microwave imaging is the computation of the image from the measurement data because of the need to solve extensive inverse scattering problems due to the sometimes complicated wave propagation. The inversion problem simplifies if only spatially limited objects—point objects, in the simplest case—with temporally variable scattering properties are of interest. Differential imaging uses this time variance by observing the scenario under test over a certain time interval. Such problems exist in medical diagnostics, in the search for surviving earthquake victims, monitoring of the vitality of persons, detection of wood pests, control of industrial processes, and much more. This paper gives an overview of imaging methods for point-like targets and discusses the impact of target variations onto the radar data. Because the target variations are very weak in many applications, a major issue of differential imaging concerns the suppression of random effects by appropriate data processing and concepts of radar hardware. The paper introduces related methods and approaches, and some applications illustrate their performance.

8.
IEEE Trans Biomed Eng ; 65(7): 1607-1616, 2018 07.
Article in English | MEDLINE | ID: mdl-28922111

ABSTRACT

Magnetic nanoparticle-aided microwave imaging is recently gaining an increasing interest as a potential tool for breast cancer diagnostics. This is due to the peculiar features of magnetic nanoparticles, which are biocompatible, can be selectively targeted to the tumor, and may change their microwave magnetic response when modulated by a polarizing magnetic field. This latter aspect is particularly appealing, as it enables the physical separation of the microwave signal due the malignancy, targeted by the nanoparticles, from that due to healthy tissue. This increases the specificity of the diagnostic tool, in principle allowing a diagnosis based solely on the detection of the signal due to the nanoparticles response. In this respect, a proper choice of the polarizing field modulation can remarkably increase the detection performances. This paper deals with this issue, by providing the mathematical framework for such an optimization and a procedure for estimating the required quantities from a set of proper measurements. The procedure is then experimentally demonstrated by applying it to a recently developed ultrawideband radar system for the magnetic nanoparticle-aided detection of breast cancer. For such a system, the optimal magnetic field modulation is determined.


Subject(s)
Breast Neoplasms/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetite Nanoparticles/chemistry , Microwaves/therapeutic use , Breast/diagnostic imaging , Equipment Design , Female , Humans , Image Interpretation, Computer-Assisted/instrumentation , Phantoms, Imaging
9.
Water Res ; 37(5): 973-82, 2003 Mar.
Article in English | MEDLINE | ID: mdl-12553972

ABSTRACT

A new control strategy for the methanogenic reactor of a two-phase anaerobic digestion system has been developed and successfully tested on the laboratory scale. The control strategy serves the purpose to detect inhibitory effects and to achieve good conversion. The concept is based on the idea that volatile fatty acids (VFA) can be measured in the influent of the methanogenic reactor by means of titration. Thus, information on the output (methane production) and input of the methanogenic reactor is available, and a (carbon) mass balance can be obtained. The control algorithm comprises a proportional/integral structure with the ratio of (a) the methane production rate measured online and (b) a maximum methane production rate expected (derived from the stoichiometry) as a control variable. The manipulated variable is the volumetric feed rate. Results are shown for an experiment with VFA (feed) concentration ramps and for experiments with sodium chloride as inhibitor.


Subject(s)
Bacteria, Anaerobic/physiology , Bioreactors , Methane/analysis , Waste Disposal, Fluid/methods , Algorithms , Fatty Acids, Volatile/analysis , Organic Chemicals/metabolism
10.
Water Res ; 36(1): 212-8, 2002 Jan.
Article in English | MEDLINE | ID: mdl-11766797

ABSTRACT

The on-line titration of volatile fatty acids (VFA) was found to be a reliable method to measure the substrate (metabolite) concentration without the use of expensive analytical devices. A measurement cell was designed that ensures stable long-term operation, high throughputs and copes with both very low and very high VFA concentrations. Using synthetic textile wastewater, a recalibration of the pH probe was necessary only twice a week. A good reproducibility of the VFA concentrations was determined and standard deviations were below +/- 1% of the measured concentration. Changing salt concentrations of the wastewater in the range of 2.5-150 gl(-1) NaCl did not influence the determined VFA concentration significantly. The method was suitable to control the hydraulic retention time in an acidic phase reactor and to determine the acidification rates of wastewater compounds in batch experiments.


Subject(s)
Environmental Monitoring/methods , Fatty Acids/analysis , Industrial Waste , Online Systems , Waste Disposal, Fluid/methods , Bacteria, Anaerobic/physiology , Bioreactors , Hydrogen-Ion Concentration , Reference Values , Reproducibility of Results , Titrimetry , Volatilization
SELECTION OF CITATIONS
SEARCH DETAIL
...