Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 88
Filter
1.
Lancet Digit Health ; 4(2): e105-e116, 2022 02.
Article in English | MEDLINE | ID: mdl-35090674

ABSTRACT

BACKGROUND: Cardiac autonomic dysfunction after myocardial infarction identifies patients at high risk despite only moderately reduced left ventricular ejection fraction. We aimed to show that telemedical monitoring with implantable cardiac monitors in these patients can improve early detection of subclinical but prognostically relevant arrhythmic events. METHODS: We did a prospective investigator-initiated, randomised, multicentre, open-label, diagnostic trial at 33 centres in Germany and Austria. Survivors of acute myocardial infarction with left ventricular ejection fraction of 36-50% had biosignal analysis for assessment of cardiac autonomic function. Patients with abnormal periodic repolarisation dynamics (≥5·75 deg2) or abnormal deceleration capacity (≤2·5 ms) were randomly assigned (1:1) to telemedical monitoring with implantable cardiac monitors or conventional follow-up. Primary endpoint was time to detection of serious arrhythmic events defined by atrial fibrillation 6 min or longer, atrioventricular block class IIb or higher and fast non-sustained (>187 beats per min; ≥40 beats) or sustained ventricular tachycardia or fibrillation. This study is registered with ClinicalTrials.gov, NCT02594488. FINDINGS: Between May 12, 2016, and July 20, 2020, 1305 individuals were screened and 400 patients at high risk were randomly assigned (median age 64 years [IQR 57-73]); left ventricular ejection fraction 45% [40-48]) to telemedical monitoring with implantable cardiac monitors (implantable cardiac monitor group; n=201) or conventional follow-up (control group; n=199). During median follow-up of 21 months, serious arrhythmic events were detected in 60 (30%) patients of the implantable cardiac monitor group and 12 (6%) patients of the control group (hazard ratio 6·33 [IQR 3·40-11·78]; p<0·001). An improved detection rate by implantable cardiac monitors was observed for all types of serious arrhythmic events: atrial fibrillation 6 min or longer (47 [23%] patients vs 11 [6%] patients; p<0·001), atrioventricular block class IIb or higher (14 [7%] vs 0; p<0·001) and ventricular tachycardia or ventricular fibrillation (nine [4%] patients vs two [1%] patients; p=0·054). INTERPRETATION: In patients at high risk after myocardial infarction and cardiac autonomic dysfunction but only moderately reduced left ventricular ejection fraction, telemedical monitoring with implantable cardiac monitors was highly effective in early detection of subclinical, prognostically relevant serious arrhythmic events. FUNDING: German Centre for Cardiovascular Research (DZHK) and Medtronic Bakken Research Center.


Subject(s)
Arrhythmias, Cardiac/diagnosis , Monitoring, Physiologic/methods , Myocardial Infarction/complications , Myocardial Infarction/physiopathology , Risk Assessment/methods , Telemedicine/methods , Aged , Austria , Female , Germany , Humans , Male , Middle Aged , Prospective Studies
2.
Herzschrittmacherther Elektrophysiol ; 32(4): 504-509, 2021 Dec.
Article in German | MEDLINE | ID: mdl-34542675

ABSTRACT

The non-physician employees in telemedicine centers (TMC) play a decisive role in the care and treatment of patients with heart failure. For this reason, a holistic profile consisting of professional and methodological as well as social and personal competences is necessary, which should be built up or promoted in corresponding training concepts. This position paper underlines the urgency of appropriate and standardized further training of non-physician employees for quality assurance in TMCs and summarizes the requirements for the additional qualification of a telemedical assistant across the board.


Subject(s)
Heart Failure , Telemedicine , Humans
3.
Artif Organs ; 44(12): 1259-1266, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32592601

ABSTRACT

The frequency of mechanical circulatory support (MCS) device application has increased in recent years. Besides implantation in the emergency setting, such as circulatory arrest, MCS is also increasingly used electively to ensure hemodynamic stability in high-risk patients, for example, during percutaneous coronary interventions (PCI), valve interventions or off-pump coronary bypass surgery. Lifebridge (Zoll Medical GmbH, Germany) is a compact percutaneous MCS device widely used in daily clinical routine. The present study aimed to investigate the indications, feasibility, and outcomes after use of Lifebridge in cardiac interventions, evaluating a large-scale multicenter database. A total of 60 tertiary cardiovascular centers were questioned regarding application and short-term outcomes after the use of the Lifebridge system (n = 160 patients). Out of these 60 centers, eight consented to participate in the study (n = 39 patients), where detailed data were collected using standardized questionnaires. Demographic and clinical characteristics of the patient population, procedural as well as follow-up data were recorded and analyzed. In 60 interrogated centers, Lifebridge was used in 74% of emergency cases and 26% in the setting of planned interventions. The subcohort interrogated in detail displayed the same distribution of application scenarios, while the main cardiovascular procedure was high-risk PCI (82%). All patients were successfully weaned from the device and 92% (n = 36) of the patients studied in detail survived after 30 days. As assessed 30 days after insertion of the device, bleeding requiring red blood cell (RBC) transfusion constituted the main complication, occurring in 49% of cases. In our analysis of clinical data, the use of Lifebridge in cardiac intervention was shown to be feasible. Further prospective studies are warranted to identify patients who benefit from hemodynamic MCS support despite the increased rate of RBC transfusion due to challenges in access sites during cardiovascular procedures.


Subject(s)
Blood Loss, Surgical/prevention & control , Extracorporeal Membrane Oxygenation/statistics & numerical data , Intraoperative Care/methods , Postoperative Hemorrhage/epidemiology , Aged , Blood Loss, Surgical/statistics & numerical data , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass, Off-Pump/statistics & numerical data , Erythrocyte Transfusion/statistics & numerical data , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Feasibility Studies , Female , Follow-Up Studies , Germany/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/statistics & numerical data , Hospital Mortality , Humans , Intraoperative Care/adverse effects , Intraoperative Care/statistics & numerical data , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/therapy , Prospective Studies , Registries/statistics & numerical data , Tertiary Care Centers/statistics & numerical data , Treatment Outcome
4.
Clin Res Cardiol ; 109(1): 46-53, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31028475

ABSTRACT

BACKGROUND: The concept of percutaneous extracorporeal life support (ECLS) is based on immediate cardiovascular stabilization allowing for sufficient end-organ perfusion, thus improving the outcome in patients with circulatory arrest. Lifebridge® (Zoll Medical GmbH, Germany) is a portable ECLS device designed for rapid application due to its automated set-up. METHODS: A total of 60 tertiary cardiovascular centers were interrogated with regard to application and short-term results after use of Lifebridge ECLS system. Detailed data were collected by standardized case report forms in all centers consented to participate in the study. Demographic and clinical baseline characteristics of the patient population, procedural and follow-up data were recorded and analyzed. RESULTS: In total, 444 patients were analyzed regarding mortality. The detailed study cohort consisted of 112 patients. A total of 80% of the study subjects represented patients post cardiopulmonary resuscitation, 43% were in cardiogenic shock and 50% suffered from acute myocardial infarction. The survival rates were 36% immediately after device implementation and 16% after 30 days. Multivariable analysis revealed that only serum lactate concentration at admission could be proven as independent predictor of patients' outcome. Patients with lactate concentrations above 10 mmol/L exhibited > 95% mortality (p < 0.05 versus below 10 mmol/L). CONCLUSION: The present study provides real-world clinical data of patients treated with a transportable automated ECLS system. In conclusion, Lifebridge is a safely applicable cardiorespiratory stabilization tool associated with acceptable complication rates. Nevertheless, mortality rates were high in these critically ill patients, especially in those showing high lactate concentrations at admission.


Subject(s)
Cardiopulmonary Resuscitation/methods , Extracorporeal Membrane Oxygenation/methods , Heart Arrest/therapy , Aged , Cohort Studies , Critical Illness , Female , Germany , Heart Arrest/mortality , Humans , Lactic Acid/blood , Male , Middle Aged , Myocardial Infarction/epidemiology , Myocardial Infarction/therapy , Registries , Retrospective Studies , Shock, Cardiogenic/epidemiology , Shock, Cardiogenic/therapy , Survival Rate
5.
Acta Crystallogr A Found Adv ; 75(Pt 6): 902-910, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31692465

ABSTRACT

This work studies the elastic scattering behavior of electron vortices when propagating through amorphous samples. A formulation of the multislice approach in cylindrical coordinates is used to theoretically investigate the redistribution of intensity between different angular momentum components due to scattering. To corroborate and elaborate on our theoretical results, extensive numerical simulations are performed on three model systems (Si3N4, Fe0.8B0.2, Pt) for a wide variety of experimental parameters to quantify the purity of the vortices, the net angular momentum transfer, and the variability of the results with respect to the random relative position between the electron beam and the scattering atoms. These results will help scientists to further improve the creation of electron vortices and enhance applications involving them.

6.
Ann Intensive Care ; 8(1): 113, 2018 Nov 23.
Article in English | MEDLINE | ID: mdl-30470931

ABSTRACT

BACKGROUND: Treatment of multiple organ failure frequently requires enhanced hemodynamic monitoring. When renal replacement is indicated, it remains unclear whether transpulmonary thermodilution (TPTD) measurements are influenced by renal replacement therapy (RRT) and whether RRT should be paused for TPTD measurements. Our aim was therefore to investigate the effect of pausing RRT on TPTD results in two dialysis catheter locations. MATERIALS AND METHODS: In total, 62 TPTD measurements in 24 patients (APACHE: 32 ± 7 [mean ± standard deviation (SD)]) were performed using the PiCCO™ system (Pulsion, Germany). Patients were treated with sustained low efficiency dialysis (SLED; Genius™ system, Fresenius, Germany) as RRT. Measurements were taken during ongoing hemodialysis (HD, HDO), during paused HD (HDP) and immediately after termination of HD and blood restitution (HDT). Dialysis catheters were placed either in the superior vena cava (SVC, 19 times) or in the inferior vena cava (IVC, 5 times). Statistical analysis was performed to assess the effects of the measurement setting, SLED (blood flow rate) and the catheter location, on cardiac index (CI), global end-diastolic volume index (GEDVI) and extravascular lung water index (EVLWI) as measured by TPTD. Multilevel models were used for the analysis due to the triplicate measurements and due to 12 out of 19 SVC and 2 out of 5 IVC patients having more than one TPTD measured. RESULTS: CI and GEDVI were significantly higher at time point HDP compared to both HDO and HDT. In contrast, values for EVLWI were lower at HDP when compared to HDO and HDT. These findings were independent of the site of dialysis catheter insertion and blood flow rate. CONCLUSIONS: PiCCO™ measurements assessed at paused SLED significantly deviate from ongoing and terminated SLED. Therefore, the dialysis system should not be paused for measurements. TPTD measurements in patients with PiCCO monitoring seem sufficiently reliable during ongoing SLED as well as after its termination. An effect of dialysis catheter location (SVC vs IVC) and blood flow rate on PiCCO™ measurements could not be shown.

7.
J Med Case Rep ; 12(1): 201, 2018 Jul 12.
Article in English | MEDLINE | ID: mdl-29996943

ABSTRACT

BACKGROUND: Acanthamoeba species can cause disseminating infections in immunocompromised individuals. CASE PRESENTATION: Here, we report a case of granulomatous acanthamoebic encephalitis with a lethal outcome in a 54-year-old German man who was human immunodeficiency virus-positive. The diagnosis was based on symptoms of progressive neurological deficits, including sensorimotor paralysis of his right leg and deteriorating alertness. Due to the rapid course and rather late diagnosis of the infection, effective treatment could not be applied and he died 12 days after hospital admission. CONCLUSIONS: To the best of our knowledge, this is the second case of granulomatous acanthamoebic encephalitis reported within Germany. Our case highlights the importance of early diagnosis of granulomatous acanthamoebic encephalitis to prevent fatal outcome.


Subject(s)
Acanthamoeba/isolation & purification , Central Nervous System Protozoal Infections/parasitology , HIV Infections/complications , Infectious Encephalitis/parasitology , Central Nervous System Protozoal Infections/complications , Central Nervous System Protozoal Infections/diagnostic imaging , Fatal Outcome , Granuloma/diagnostic imaging , Granuloma/parasitology , Humans , Infectious Encephalitis/complications , Infectious Encephalitis/diagnostic imaging , Male , Middle Aged
8.
EuroIntervention ; 14(10): 1096-1103, 2018 Nov 20.
Article in English | MEDLINE | ID: mdl-29808819

ABSTRACT

AIMS: Although several studies have shown positive outcomes after the use of drug-coated balloons (DCB) for in-stent restenosis (ISR), data on randomised controlled trials versus latest-generation drug-eluting stents (DES) are limited. Therefore, in this randomised trial, we sought to evaluate whether a butyryl-tri-hexyl citrate (BTHC)-based paclitaxel DCB is non-inferior to a biodegradable polymer sirolimus-eluting stent (BP-SES) therapy in patients with ISR in either a bare metal stent (BMS) or DES. METHODS AND RESULTS: A total of 229 patients with ISR in BMS or DES from 13 German centres and one Latvian centre were 2:1 randomly allocated to DCB (n=157) or DES (n=72). The primary efficacy endpoint was defined as in-stent late lumen loss (LLL) at six months, and the primary safety endpoint was target lesion failure (TLF) at 12 months. LLL in the DCB arm was 0.03±0.40 mm compared to 0.20±0.70 mm in the DES arm (p=0.40). DCB proved to be non-inferior to DES (Δ = -0.17±0.52 mm, 97.5% CI -∞; -0.01]; p<0.0001). At 12 months, Kaplan-Meier TLF estimates were 16.7% in the DCB arm and 14.2% in the DES arm (p=0.65) and remained similar at 18 months (DCB versus DES: 17.4% versus 19.5%, p=0.88). CONCLUSIONS: In patients with DES or BMS ISR, treatment with a paclitaxel DCB showed similar LLL at six months and TLF rates up to 18 months compared to a second-generation sirolimus DES.


Subject(s)
Angioplasty, Balloon, Coronary , Coronary Restenosis , Drug-Eluting Stents , Coronary Angiography , Humans , Paclitaxel , Prosthesis Design , Sirolimus , Stents , Treatment Outcome
9.
Heart ; 103(24): 1970-1976, 2017 12.
Article in English | MEDLINE | ID: mdl-28684438

ABSTRACT

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) has been implemented into the care of elderly patients suffering from severe symptomatic aortic stenosis. However, data on long-term follow-up are sparse and predictors of long-term mortality need to be evaluated to better select patients. Therefore, we aimed to analyse predictors of 5-year mortality after TAVI. METHODS: We analysed data from the German Transcatheter Aortic Valve Interventions-Registry. Each of the 27 participating hospitals agreed to include all consecutive TAVI patients at their institution. Out of 1444 patients treated with TAVI, 1378 patients had a follow-up of at least 4.5 years (completeness 95.4%). Endpoint for this analysis was 5-year survival. Cox regression analysis was used to determine risk factors associated with this endpoint. RESULTS: Patients who died were compared with survivors. The two groups showed multiple differences in patient characteristics, indications for interventions, preinterventional, as well as interventional characteristics and postinterventional events. Calculated 1-year mortality was 21.8% and 5-year mortality 59.1%. A higher logistic EuroScore was associated with a lower 5-year survival, being 45.5% in patients with a logistic EuroScore of <20%, 34.5% in those with 20% to 40% and 28.4% in patients with a logistic EuroScore >40%. Cox proportional hazard analysis revealed the following independent predictors of 5-year mortality: female gender (HR =0.66, 95% CI 0.56 to 0.77, p<0.0001), renal failure (HR=1.43, 95% CI 1.22 to 1.69, p<0.0001), prior mitral regurgitation ≥II° (HR=1.42, 95% CI 1.21 to 1.65, p<0.0001), residual aortic regurgitation ≥II° (HR=1.52, 95% CI 1.24 to 1.85, p<0.0001), atrial fibrillation (HR=1.38, 95% CI 1.18 to 1.64, p=0.0001), low gradient aortic stenosis (HR=1.48, 95% CI 1.19 to 1.84, p=0.0004), prior decompensation (HR=1.32, 95% CI 1.13 to 1.54, p=0.0006), frailty (HR=1.31, 95% CI 1.09 to 1.58, p=0.004), surgical TAVI (HR=1.42, 95% CI 1.12 to 1.80, p=0.004), age (by year) (HR=1.02, 95% CI 1.01 to 1.03, p=0.006), prior myocardial infarction (HR=1.29, 95% CI 1.07 to 1.57, p=0.009), urgent TAVI (HR=1.25, 95% CI 1.04 to 51, p=0.020) and diabetes mellitus (HR=1.20, 95% CI 1.02 to 1.40, p=0.024). CONCLUSIONS: These data from the early TAVI experience show a 5-year mortality of 59.1%. Some of the predictors of 5-year mortality seem to be modifiable, such as residual aortic regurgitation, type of TAVI access route and concomitant mitral regurgitation.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Germany , Heart Valve Prosthesis , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/physiopathology , Multivariate Analysis , Proportional Hazards Models , Prosthesis Design , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
10.
J Am Heart Assoc ; 6(3)2017 Mar 20.
Article in English | MEDLINE | ID: mdl-28320749

ABSTRACT

BACKGROUND: Several studies have suggested sex-related differences in diagnostic and invasive therapeutic coronary procedures. METHODS AND RESULTS: Data from consecutive patients who were enrolled in the Coronary Angiography and PCI Registry of the German Society of Cardiology were analyzed. We aimed to compare sex-related differences in in-hospital outcomes of patients undergoing percutaneous coronary intervention (PCI) for stable coronary artery disease, non-ST elevation acute coronary syndromes, ST elevation myocardial infarction, and cardiogenic shock. From 2007 until the end of 2009 data from 185 312 PCIs were prospectively registered: 27.9% of the PCIs were performed in women. Primary PCI success rate was identical between the sexes (94%). There were no sex-related differences in hospital mortality among patients undergoing PCI for stable coronary artery disease, non-ST elevation acute coronary syndromes, or cardiogenic shock except among ST elevation myocardial infarction patients. Compared to men, women undergoing primary PCI for ST elevation myocardial infarction have a higher risk of in-hospital death, age-adjusted odds ratio (1.19, 95% CI 1.06-1.33), and risk of ischemic cardiac and cerebrovascular events (death, myocardial infarction, transient ischemic attack/stroke), (age-adjusted odds ratio 1.19, 95% CI 1.16-1.29). Furthermore, access-related complications were twice as high in women, irrespective of the indication. CONCLUSIONS: Despite identical technical success rates of PCI between the 2 sexes, women with PCI for ST elevation myocardial infarction have a 20% higher age-adjusted risk of death and of ischemic cardiac and cerebrovascular events. Further research is needed to determine the reasons for these differences.


Subject(s)
Acute Coronary Syndrome/surgery , Coronary Artery Disease/surgery , Non-ST Elevated Myocardial Infarction/surgery , Percutaneous Coronary Intervention/methods , Registries , ST Elevation Myocardial Infarction/surgery , Shock, Cardiogenic/surgery , Age Factors , Aged , Cardiology , Coronary Angiography , Female , Germany , Hospital Mortality , Humans , Male , Middle Aged , Odds Ratio , Sex Factors , Societies, Medical
11.
JACC Cardiovasc Interv ; 9(24): 2541-2554, 2016 12 26.
Article in English | MEDLINE | ID: mdl-28007203

ABSTRACT

OBJECTIVES: This study sought to analyze health-related quality-of-life (HrQoL) outcomes of patients undergoing transcatheter aortic valve replacement (TAVR) based on data from GARY (German Aortic Valve Registry). BACKGROUND: Typically, patients currently referred for and treated by TAVR are elderly with a concomitant variable spectrum of multiple comorbidities, disabilities, and limited life expectancy. Beyond mortality and morbidity, the assessment of HrQoL is of paramount importance not only to guide patient-centered clinical decision-making but also to judge this new treatment modality in this high-risk patient population. METHODS: In 2011, 3,875 patients undergoing TAVR were included in the GARY registry. HrQoL was prospectively measured using the EuroQol 5 dimensions questionnaire self-complete version on paper at baseline and 1 year. RESULTS: Complete follow-up EuroQol 5 dimensions questionnaire evaluation was available for 2,288 patients (transvascular transcatheter aortic valve replacement [TAVR-TV]: n = 1,626 and transapical TAVR [TAVR-TA]: n = 662). In-hospital mortality was 5.9% (n = 229) and the 1-year mortality was 23% (n = 893). The baseline visual analog scale score for general health status was 52.6% for TAVR-TV and 55.8% for TAVR-TA and, in parallel to an improvement in New York Heart Association functional class, improved to 59.6% and 58.5% at 1 year, respectively (p < 0.001). Between baseline and 1 year, the number of patients reporting no complaints increased by 7.8% (TAVR-TV) and by 3.5% within the mobility dimension, and by 14.1% (TAVR-TV) and 9.2% within the usual activity dimension, whereas only moderate changes were found for the self-care, pain or discomfort, and anxiety or depression dimensions. In a multiple linear regression analysis several pre- and post-operative factors were predictive for less pronounced HrQoL benefits. CONCLUSIONS: TAVR treatment led to improvements in HrQoL, especially in terms of mobility and usual activities. The magnitude of improvements was higher in the TAVR-TV group as compared to the TAVR-TA group. However, there was a sizable group of patients who did not derive any HrQoL benefits. Several independent pre- and post-operative factors were identified being predictive for less pronounced HrQoL benefits.


Subject(s)
Aortic Valve Stenosis/surgery , Quality of Life , Transcatheter Aortic Valve Replacement , Activities of Daily Living , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/psychology , Chi-Square Distribution , Female , Germany , Hospital Mortality , Humans , Linear Models , Male , Mobility Limitation , Prospective Studies , Recovery of Function , Registries , Risk Factors , Surveys and Questionnaires , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
12.
Ann Thorac Surg ; 101(2): 658-66, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26576751

ABSTRACT

BACKGROUND: Conventional aortic valve replacement (AVR) remains the therapy of choice for many patients with severe aortic valve disease. The unique German Aortic Valve Registry (GARY) allows the comparison of contemporary outcomes of AVR with those of transcatheter AVRs. We report here real-world, all-comers outcomes of AVR, including combined AVR and coronary bypass grafting (AVR+CABG). METHODS: A total of 34,063 patients who received AVR (22,107 patients, 39% female; mean age 68.0 ± 11.3 years, mean logistic European System for Cardiac Operative Risk Evaluation, 8.6%) or AVR+CABG (11,956 patients, 28% female; mean age 72.6 ± 7.8 years, mean logistic European System for Cardiac Operative Risk Evaluation, 10.7%) between 2011 and 2013 were analyzed and followed up to assess the 1-year outcome. RESULTS: In-hospital mortality was 2.3% for AVR and 4.1% for AVR+CABG. Other important outcome variables include stroke (AVR, 1.2%; AVR+CABG, 1.9%) and new pacemaker implantation (AVR, 4.4%; AVR+CABG, 3.6%). Survival at 1 year was 93.2% for AVR and 89.4% for AVR+CABG. Total stroke rates at 1 year were 1.6% for AVR and 2.0% AVR+CABG. Quality of life assessment indicated that most patients were in New York Heart Association Functional Classification I or II (AVR, 86%; AVR+CABG, 84%) and that they were satisfied with the overall postoperative course (AVR, 88%; AVR+CABG, 87%). CONCLUSIONS: Contemporary surgical AVR yields excellent outcomes with low in-hospital mortality, a low overall complication rate, and good 1-year outcome for all risk groups. Accordingly, conventional AVR remains an important therapeutic option for many patients.


Subject(s)
Heart Defects, Congenital/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve/surgery , Bicuspid Aortic Valve Disease , Female , Germany , Heart Valve Prosthesis Implantation/methods , Humans , Male , Registries , Treatment Outcome
13.
Malar J ; 13: 422, 2014 Nov 04.
Article in English | MEDLINE | ID: mdl-25367021

ABSTRACT

During the last two decades human infections with Plasmodium knowlesi are increasingly diagnosed in South East Asia and have also been reported in travellers. A severe case of imported P. knowlesi infection in a 73-year old German is presented, who had been travelling through Myanmar and Thailand for three weeks. Microscopy showed a parasitaemia of 3% and different parasite stages including band-forms resembling Plasmodium malariae. Due to the clinical picture of severe malaria and the microscopical aspect (combination of parasites resembling P. malariae and Plasmodium falciparum), P. knowlesi was suspected. The patient was treated with intravenous quinine; he was put on mechanical ventilation and catecholamines due to cardiorespiratory failure. Parasitaemia was cleared rapidly but renal function deteriorated resulting in intermittent haemodialysis. The patient was hospitalized for six weeks but he recovered completely without any physical sequelae. Plasmodium knowlesi mono-infection was confirmed by molecular methods later on.Plasmodium knowlesi infection has to be taken into account in feverish travellers returning from Thailand/Myanmar. Moreover this species can cause life-threatening or even lethal complications. Accordingly severe P. knowlesi infection should be treated like severe P. falciparum infections.


Subject(s)
Malaria , Multiple Organ Failure , Plasmodium knowlesi , Aged , Germany , Humans , Male , Thailand , Travel
14.
EuroIntervention ; 10(7): 850-9, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25415152

ABSTRACT

AIMS: The study analyses the outcome of patients undergoing transcatheter aortic valve implantation (TAVI) for different subtypes of severe aortic stenosis (AS) based on data from the GARY registry. METHODS AND RESULTS: Low-EF, low-gradient (LEF-LGAS: EF ≤40%, MPG <40 mmHg), paradoxical low-gradient (PLF-LGAS: EF ≥50%, MPG <40 mmHg) and high-gradient AS (HGAS: MPG ≥40 mmHg) were observed in 11.7% (n=359), 20.8% (n=640) and 60.6% (n=1,864) of the study population, respectively. EuroSCORE I (36.7±20.9 vs. 22.6±15.7 vs. 24.3±17.4; p<0.001) differed significantly among subgroups. In-hospital and one-year mortality were higher in patients with LEF-LGAS compared to HGAS (in-hospital: 7.8% vs. 4.9%; p=0.029; one-year: 32.3% vs. 19.8%; p=0.001). In contrast, mortality in patients with PLF-LGAS was comparable to patients with HGAS (in-hospital: PLF-LGAS: 5.3%; p=0.67; one-year: 22.3%; p=0.192). The rate of TAVI-associated complications was not significantly different among groups. However, postoperative low cardiac output occurred significantly more frequently in patients with LEF-LGAS Conclusions: Severe AS with a reduced transaortic flow and gradient is a common finding and is present in >30% of patients undergoing TAVI. Patients with low flow and impaired LV function have a significantly higher mortality within the first year after TAVI. In contrast, the outcome of patients with low flow and preserved EF is comparable to those with a high transvalvular aortic gradient.


Subject(s)
Aortic Valve Stenosis/surgery , Stroke Volume , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve Stenosis/physiopathology , Female , Hospital Mortality , Humans , Logistic Models , Male , Registries , Transcatheter Aortic Valve Replacement/mortality
15.
EuroIntervention ; 10(5): 602-8, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25256201

ABSTRACT

AIMS: To analyse patient characteristics, decision-making processes, and outcomes of TAVI performed in hospitals with versus those without on-site cardiac surgery (CS). METHODS AND RESULTS: Current guidelines mandate transcatheter aortic valve implantation (TAVI) to be performed at hospitals with both cardiology and on-site CS departments. Some hospitals in Germany perform TAVI without CS departments in-house. We analysed the data of 1,432 patients enrolled in the German TAVI registry at 27 hospitals between January 2009 and June 2010. Nineteen of these had on-site CS (group 1), while eight centres performed TAVI with no CS department at their institution (group 2). Patients in group 2 (n=178, 12% of the overall study population) were older than in group 1 (mean age 82.6±6.3 years vs. 81.6±6.2 years) with similar logistic EuroSCORE (average: 21%). Patients in group 2 were haemodynamically more stable (higher blood pressures, better ejection fraction, less low-flow or low-gradient aortic stenosis, and less urgent procedures). Procedure times and use of contrast were higher in group 2. The procedural success rate was higher in group 1 (98% vs. 95%). Post-procedural complications were similar in the two groups with 30-day mortality of 6.2% in group 2 compared with 8.3% in group 1 patients. CONCLUSIONS: Only 12% of patients enrolled in the German TAVI registry underwent TAVI at hospitals without an on-site CS department. Overall patient characteristics appeared to be similar, although patients in non-CS centres appeared to be haemodynamically more stable and more often had a history of previous heart surgery. Despite longer procedures, complication rates were similar. These preliminary data in a modest number of patients suggest the feasibility of performing TAVI in appropriately selected patients at hospitals without CS but this requires confirmation in future studies involving a large number of patients.


Subject(s)
Aortic Valve Stenosis/surgery , Endovascular Procedures/statistics & numerical data , Heart Valve Prosthesis Implantation/statistics & numerical data , Postoperative Complications/epidemiology , Registries , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Female , Germany/epidemiology , Humans , Male , Thoracic Surgery/organization & administration , Ultrasonography
16.
Eur J Cardiothorac Surg ; 46(5): 808-16, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25079769

ABSTRACT

OBJECTIVES: The German Aortic Valve Registry (GARY) seeks to provide information on a real-world, all-comers basis for patients undergoing aortic valve interventions. This registry comprises patients undergoing the complete spectrum of transcutaneous and conventional surgical aortic valve interventions. The aim of this study was to use the GARY registry to evaluate conventional and catheter-based aortic valve interventions in several risk groups. METHODS: A total of 13 860 consecutive patients undergoing intervention for aortic valve disease [conventional aortic valve replacement (AVR) or transvascular/transapical TAVR (TV-/TA-TAVR)] were enrolled in 78 German centres in 2011. Baseline, procedural and outcome data, including quality of life, were acquired up to 1 year post-intervention. Vital status at 1 year was known for 98.1% of patients. RESULTS: The 1-year mortality rate was 6.7% for conventional AVR patients (n = 6523) and 11.0% for patients who underwent AVR with coronary artery bypass grafting (n = 3464). The 1-year mortality rate was 20.7 and 28.0% in TV- and TA-TAVR patients, respectively (n = 2695 and 1181). However, if patients were stratified into four risk groups by means of the EuroSCORE and the German AV Score, the highest risk cohorts showed the same mortality at 1 year with either therapy. More than 80% of patients in all groups were in the same or better state of health at 1 year post-intervention and were satisfied with the procedural outcome. CONCLUSIONS: Conventional AVR surgery yields excellent results after 1 year in lower-risk patients. Catheter-based AVR is a good alternative in high-risk and elderly patients.


Subject(s)
Heart Defects, Congenital/surgery , Heart Valve Diseases/surgery , Aortic Valve/surgery , Bicuspid Aortic Valve Disease , Germany/epidemiology , Heart Defects, Congenital/epidemiology , Heart Defects, Congenital/mortality , Heart Valve Diseases/epidemiology , Heart Valve Diseases/mortality , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Quality of Life , Registries , Survival Analysis
17.
Lancet ; 384(9943): 583-590, 2014 Aug 16.
Article in English | MEDLINE | ID: mdl-25131977

ABSTRACT

BACKGROUND: An increasing number of patients with heart failure receive implantable cardioverter-defibrillators (ICDs) or cardiac resynchronisation defibrillators (CRT-Ds) with telemonitoring function. Early detection of worsening heart failure, or upstream factors predisposing to worsening heart failure, by implant-based telemonitoring might enable pre-emptive intervention and improve outcomes, but the evidence is weak. We investigated this possibility in IN-TIME, a clinical trial. METHODS: We did this randomised, controlled trial at 36 tertiary clinical centres and hospitals in Australia, Europe, and Israel. We enrolled patients with chronic heart failure, NYHA class II-III symptoms, ejection fraction of no more than 35%, optimal drug treatment, no permanent atrial fibrillation, and a recent dual-chamber ICD or CRT-D implantation. After a 1 month run-in phase, patients were randomly assigned (1:1) to either automatic, daily, implant-based, multiparameter telemonitoring in addition to standard care or standard care without telemonitoring. Investigators were not masked to treatment allocation. Patients were masked to allocation unless they were contacted because of telemonitoring findings. Follow-up was 1 year. The primary outcome measure was a composite clinical score combining all-cause death, overnight hospital admission for heart failure, change in NYHA class, and change in patient global self-assessment, for the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT00538356. FINDINGS: We enrolled 716 patients, of whom 664 were randomly assigned (333 to telemonitoring, 331 to control). Mean age was 65·5 years and mean ejection fraction was 26%. 285 (43%) of patients had NYHA functional class II and 378 (57%) had NYHA class III. Most patients received CRT-Ds (390; 58·7%). At 1 year, 63 (18·9%) of 333 patients in the telemonitoring group versus 90 (27·2%) of 331 in the control group (p=0·013) had worsened composite score (odds ratio 0·63, 95% CI 0·43-0·90). Ten versus 27 patients died during follow-up. INTERPRETATION: Automatic, daily, implant-based, multiparameter telemonitoring can significantly improve clinical outcomes for patients with heart failure. Such telemonitoring is feasible and should be used in clinical practice. FUNDING: Biotronik SE & Co. KG.


Subject(s)
Defibrillators, Implantable , Heart Failure/physiopathology , Heart Failure/therapy , Monitoring, Ambulatory/instrumentation , Telemedicine/methods , Aged , Australia , Europe , Female , Humans , Israel , Male , Treatment Outcome
18.
Heart ; 100(16): 1250-6, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24895354

ABSTRACT

OBJECTIVE: Residual aortic regurgitation (AR) after transcatheter aortic valve implantation (TAVI) has been associated with increased mortality. Nevertheless, a considerable proportion of these patients survives and appears to tolerate AR. Identification of patients at higher risk of death may assist in tailoring therapy, but predictors of mortality in this subset of patients is largely unknown. METHODS: A total of 1432 patients were included in the German TAVI registry. One-year follow-up data were available for 1318 patients (92%). Of the latter, 201 patients (15.2%) had more-than-mild AR as evaluated by angiography and represent the population of the current analysis. Among these patients, baseline demographic, clinical, echocardiographic and angiographic characteristics were compared among survivors and non-survivors to identify factors associated with mortality at 1 year. RESULTS: Mean age was 81.2±6.6 years and men represented 55%. The mean logistic EuroSCORE was 22±15%. Overall, 92% of patients received the Medtronic CoreValve and 8% received the Edwards Sapien valve. At 1 year, 61 patients (31%) with more-than-mild post-TAVI AR had died. Compared with patients who survived, patients who died had more commonly coronary artery disease, peripheral arterial disease and chronic renal impairment. Patients who died had a lower baseline LVEF (44±18% vs 52±16%, p=0.002), higher prevalence of more-than-mild (≥2+) mitral regurgitation (44% vs 27%, p=0.001), and a higher systolic pulmonary artery pressure (51±18 mm Hg vs 44±19 mm Hg, p=0.002), but the severity of aortic stenosis was similar, and the prevalence and severity of pre-TAVI AR was comparable (any AR in 88% vs 83%, respectively, p=0.29). Using Cox regression analysis, only baseline mitral regurgitation ≥2+ (HR 1.77, 95% CI 1.05 to 2.99, p=0.03) and systolic pulmonary artery pressure (HR 1.15, 95% CI 1.01 to 1.33, p=0.04) were independently associated with 1-year mortality, while female gender was protective (HR 0.54, 95% CI 0.30 to 0.96, p=0.03). CONCLUSIONS: We identified preprocedural characteristics associated with 1-year mortality in patients with more-than-mild AR after TAVI. More-than-mild baseline mitral regurgitation, higher systolic pulmonary artery pressure and male gender were independently associated with worse outcome.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis/adverse effects , Aged , Aged, 80 and over , Angiography/methods , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/physiopathology , Comorbidity , Coronary Artery Disease/epidemiology , Echocardiography/methods , Female , Germany/epidemiology , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/statistics & numerical data , Humans , Male , Outcome Assessment, Health Care , Peripheral Arterial Disease/epidemiology , Prognosis , Prospective Studies , Registries , Renal Insufficiency, Chronic/epidemiology , Risk Factors , Severity of Illness Index , Survival Rate
19.
Clin Res Cardiol ; 103(8): 613-20, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24599329

ABSTRACT

OBJECTIVES: The aim of this analysis is to examine the influence of gender differences on the outcome after transcatheter aortic valve implantation (TAVI) from a multicenter real-world registry in Germany (TAVI registry). BACKGROUND: The impact of gender differences on the clinical outcome after TAVI was examined in small studies with conflicting results. METHODS: Consecutive patients (n = 1,432) undergoing TAVI in the period between January 2009 and June 2010 in Germany were evaluated. Differences in all-cause mortality were examined with Kaplan-Meier estimates and proportional hazards models. RESULTS: Women comprised 57.8 % of the cohort. The Edwards Sapien valve (18.5 %) and CoreValve (81.5 %) were used through the transfemoral (87.7 %), subclavian (3.0 %), transapical (8.6 %), or transaortic approach (0.7 %). At baseline, women had higher aortic gradients and were older. Men had more comorbidities: prior myocardial infarction, prior revascularization, prior coronary artery bypass surgery, peripheral arterial vascular disease and chronic obstructive pulmonary disease. Women had more periprocedural vascular complications in comparison to men (25.2 vs. 17.2 %, p < 0.001). There was no significant difference in mortality at 30-day follow-up (7.6 % for women vs. 8.6 % for men, p = 0.55). The adjusted HR for 1-year all-cause mortality favored women, HR 0.75 (95 % CI 0.57-0.98, p = 0.0346) with a mortality rate of 17.3 vs. 23.6 % for men. CONCLUSIONS: Female gender is associated with better 1-year survival after TAVI. These results suggest that TAVI could be the best treatment modality for elderly women with symptomatic severe aortic stenosis.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/pathology , Female , Follow-Up Studies , Germany , Humans , Kaplan-Meier Estimate , Male , Proportional Hazards Models , Registries , Risk Factors , Severity of Illness Index , Sex Factors , Survival Rate , Time Factors , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality
20.
Eur Heart J ; 35(24): 1588-98, 2014 Jun 21.
Article in English | MEDLINE | ID: mdl-24022003

ABSTRACT

BACKGROUND: Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. METHODS AND RESULTS: A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). CONCLUSION: The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/statistics & numerical data , Hospitalization/statistics & numerical data , Adolescent , Adult , Age Distribution , Aged , Aged, 80 and over , Aortic Valve Stenosis/mortality , Female , Germany/epidemiology , Heart Valve Prosthesis/statistics & numerical data , Heart Valve Prosthesis Implantation/mortality , Hospital Mortality , Humans , Male , Middle Aged , Operative Time , Patient Selection , Prognosis , Registries , Risk Assessment , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/statistics & numerical data , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...