Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 62
Filter
1.
Virol J ; 21(1): 99, 2024 04 29.
Article in English | MEDLINE | ID: mdl-38685117

ABSTRACT

BACKGROUND: During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests' clinical accuracy. METHODS: We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. RESULTS: We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer's instructions and those conducted differently, or between point-of-care and lab-based testing. CONCLUSION: Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.


Subject(s)
Antigens, Viral , COVID-19 Serological Testing , COVID-19 , SARS-CoV-2 , Sensitivity and Specificity , Humans , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/immunology , COVID-19 Serological Testing/methods , Antigens, Viral/immunology , Antigens, Viral/analysis , COVID-19 Testing/methods
2.
PLOS Glob Public Health ; 4(3): e0002369, 2024.
Article in English | MEDLINE | ID: mdl-38498477

ABSTRACT

The widespread use of antigen-detection rapid diagnostic tests (Ag-RDTs) has revolutionized SARS-CoV-2 (COVID-19) testing, particularly through the option of self-testing. The full extent of Ag-RDT utilization for self-testing, however, remains largely unexplored. To inform the development of WHO guidance on COVID-19 self-testing, we conducted a global consultation to gather the views and experiences of policy makers, researchers, and implementers worldwide. The consultation was conducted by disseminating a WHO questionnaire through professional networks via email and social media, encouraging onward sharing. We used a cross-sectional design with both closed and open-ended questions related to policy and program information concerning the regulation, availability, target population, indications, implementation, benefits, and challenges of COVID-19 self-testing (C19ST). We defined self-testing as tests performed and interpreted by an untrained individual, often at home. Descriptive summaries, cross-tabulations, and proportions were used to calculate outcomes at the global level and by WHO region and World Bank income classifications. All information was collated and reported according to WHO guideline development standards and practice for global consultations. Between 01 and 11 February 2022, 844 individuals from 139 countries responded to the survey, with 45% reporting affiliation with governments and 47% operating at the national level. 504 respondents from 101 countries reported policies supporting C19ST for a range of use cases, including symptomatic and asymptomatic populations. More respondents from low-and-middle-income countries (LMICs) than high-income countries (HICs) reported a lack of an C19ST policy (61 vs 11 countries) and low population-level reach of C19ST. Respondents with C19ST experience perceived that the tests were mostly acceptable to target populations, provided significant benefits, and highlighted several key challenges to be addressed for increased success. Reported costs varied widely, ranging from specific programmes enabling free access to certain users and others with high costs via the private sector. Based on this consultation, systems for the regulatory review, policy development and implementation of C19ST appeared to be much more common in HIC when compared to LIC in early 2022, though most respondents indicated self-testing was available to some extent (101 out of 139 countries) in their country. Addressing such global inequities is critical for ensuring access to innovative and impactful interventions in the context of a public health emergency of international concern. The challenges and opportunities highlighted by key stakeholders could be valuable to consider as future testing strategies are being set for outbreak-prone diseases.

3.
BMJ Open ; 14(2): e078674, 2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38417953

ABSTRACT

OBJECTIVES: To determine the most epidemiologically effective and cost-effective school-based SARS-CoV-2 antigen-detection rapid diagnostic test (Ag-RDT) self-testing strategies among teachers and students. DESIGN: Mathematical modelling and economic evaluation. SETTING AND PARTICIPANTS: Simulated school and community populations were parameterised to Brazil, Georgia and Zambia, with SARS-CoV-2 self-testing strategies targeted to teachers and students in primary and secondary schools under varying epidemic conditions. INTERVENTIONS: SARS-CoV-2 Ag-RDT self-testing strategies for only teachers or teachers and students-only symptomatically or symptomatically and asymptomatically at 5%, 10%, 40% or 100% of schools at varying frequencies. OUTCOME MEASURES: Outcomes were assessed in terms of total infections and symptomatic days among teachers and students, as well as total infections and deaths within the community under the intervention compared with baseline. The incremental cost-effectiveness ratios (ICERs) were calculated for infections prevented among teachers and students. RESULTS: With respect to both the reduction in infections and total cost, symptomatic testing of all teachers and students appears to be the most cost-effective strategy. Symptomatic testing can prevent up to 69·3%, 64·5% and 75·5% of school infections in Brazil, Georgia and Zambia, respectively, depending on the epidemic conditions, with additional reductions in community infections. ICERs for symptomatic testing range from US$2 to US$19 per additional school infection averted as compared with symptomatic testing of teachers alone. CONCLUSIONS: Symptomatic testing of teachers and students has the potential to cost-effectively reduce a substantial number of school and community infections.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19/epidemiology , Cost-Benefit Analysis , Self-Testing , Schools
4.
Sci Rep ; 13(1): 21913, 2023 12 11.
Article in English | MEDLINE | ID: mdl-38081881

ABSTRACT

Self-testing is an effective tool to bridge the testing gap for several infectious diseases; however, its performance in detecting SARS-CoV-2 using antigen-detection rapid diagnostic tests (Ag-RDTs) has not been systematically reviewed. This study aimed to inform WHO guidelines by evaluating the accuracy of COVID-19 self-testing and self-sampling coupled with professional Ag-RDT conduct and interpretation. Articles on this topic were searched until November 7th, 2022. Concordance between self-testing/self-sampling and fully professional-use Ag-RDTs was assessed using Cohen's kappa. Bivariate meta-analysis yielded pooled performance estimates. Quality and certainty of evidence were evaluated using QUADAS-2 and GRADE tools. Among 43 studies included, twelve reported on self-testing, and 31 assessed self-sampling only. Around 49.6% showed low risk of bias. Overall concordance with professional-use Ag-RDTs was high (kappa 0.91 [95% confidence interval (CI) 0.88-0.94]). Comparing self-testing/self-sampling to molecular testing, the pooled sensitivity and specificity were 70.5% (95% CI 64.3-76.0) and 99.4% (95% CI 99.1-99.6), respectively. Higher sensitivity (i.e., 93.6% [95% CI 90.4-96.8] for Ct < 25) was estimated in subgroups with higher viral loads using Ct values as a proxy. Despite high heterogeneity among studies, COVID-19 self-testing/self-sampling exhibits high concordance with professional-use Ag-RDTs. This suggests that self-testing/self-sampling can be offered as part of COVID-19 testing strategies.Trial registration: PROSPERO: CRD42021250706.


Subject(s)
COVID-19 Testing , COVID-19 , Humans , SARS-CoV-2 , COVID-19/diagnosis , Rapid Diagnostic Tests , Self-Testing , Sensitivity and Specificity
7.
PLOS Glob Public Health ; 3(6): e0001555, 2023.
Article in English | MEDLINE | ID: mdl-37267241

ABSTRACT

Serological assays have been used in seroprevalence studies to inform the dynamics of COVID-19. Lateral flow immunoassay (LFIA) tests are a very practical technology to use for this objective; however, one of their challenges may be variable diagnostic performance. Given the numerous available LFIA tests, evaluation of their accuracy is critical before real-world implementation. We performed a retrospective diagnostic evaluation study to independently determine the diagnostic accuracy of 4 different antibody-detection LFIA tests: Now Check (Bionote), CareStart (Access bio), Covid-19 BSS (Biosynex) and OnSite (CTK Biotech). The sample panel was comprised of specimens collected and stored in biobanks; specifically, specimens that were RT-PCR positive for SARS-CoV-2 collected at various times throughout the COVID-19 disease course and those that were collected before the pandemic, during 2018 or earlier, from individuals with upper respiratory symptoms but were negative for tuberculosis. Clinical performance (sensitivity and specificity) was analyzed overall, and subset across individual antibody isotypes, and days from symptoms onset. A very high specificity (98% - 100%) was found for all four tests. Overall sensitivity was variable, ranging from 29% [95% CI: 21%-39%] to 64% [95% CI: 54%-73%]. When considering detection of IgM only, the highest sensitivity was 42% [95% CI: 32%-52%], compared to 57% [95% CI: 47%-66%] for IgG only. When the analysis was restricted to at least 15 days since symptom onset, across any isotype, the sensitivity reached 90% for all four brands. All four LFIA tests proved effective for identifying COVID-19 antibodies when two conditions were met: 1) at least 15 days have elapsed since symptom onset and 2) a sample is considered positive when either IgM or IgG is present. With these considerations, the use of this assays could help in seroprevalence studies or further exploration of its potential uses.

8.
Front Public Health ; 11: 1146730, 2023.
Article in English | MEDLINE | ID: mdl-37361158

ABSTRACT

The onset of the COVID-19 pandemic triggered a rapid scale-up in the use of genomic surveillance as a pandemic preparedness and response tool. As a result, the number of countries with in-country SARS-CoV-2 genomic sequencing capability increased by 40% from February 2021 to July 2022. The Global Genomic Surveillance Strategy for Pathogens with Pandemic and Epidemic Potential 2022-2032 was launched by the World Health Organization (WHO) in March 2022 to bring greater coherence to ongoing work to strengthen genomic surveillance. This paper describes how WHO's tailored regional approaches contribute to expanding and further institutionalizing the use of genomic surveillance to guide pandemic preparedness and response measures as part of a harmonized global undertaking. Challenges to achieving this vision include difficulties obtaining sequencing equipment and supplies, shortages of skilled staff, and obstacles to maximizing the utility of genomic data to inform risk assessment and public health action. WHO is helping to overcome these challenges in collaboration with partners. Through its global headquarters, six regional offices, and 153 country offices, WHO is providing support for country-driven efforts to strengthen genomic surveillance in its 194 Member States, with activities reflecting regional specificities. WHO's regional offices serve as platforms for those countries in their respective regions to share resources and knowledge, engage stakeholders in ways that reflect national and regional priorities, and develop regionally aligned approaches to implementing and sustaining genomic surveillance within public health systems.


Subject(s)
COVID-19 , Humans , COVID-19/epidemiology , SARS-CoV-2/genetics , Pandemics , Emergencies , World Health Organization , Genomics
9.
PLoS One ; 18(3): e0278653, 2023.
Article in English | MEDLINE | ID: mdl-36862684

ABSTRACT

OBJECTIVES: To assess the real-world diagnostic performance of nasal and nasopharyngeal swabs for SD Biosensor STANDARD Q COVID-19 Antigen Rapid Diagnostic Test (Ag-RDT). METHODS: Individuals ≥5 years with COVID-19 compatible symptoms or history of exposure to SARS-CoV-2 presenting at hospitals in Lesotho received two nasopharyngeal and one nasal swab. Ag-RDT from nasal and nasopharyngeal swabs were performed as point-of-care on site, the second nasopharyngeal swab used for polymerase chain reaction (PCR) as the reference standard. RESULTS: Out of 2198 participants enrolled, 2131 had a valid PCR result (61% female, median age 41 years, 8% children), 84.5% were symptomatic. Overall PCR positivity rate was 5.8%. The sensitivity for nasopharyngeal, nasal, and combined nasal and nasopharyngeal Ag-RDT result was 70.2% (95%CI: 61.3-78.0), 67.3% (57.3-76.3) and 74.4% (65.5-82.0), respectively. The respective specificity was 97.9% (97.1-98.4), 97.9% (97.2-98.5) and 97.5% (96.7-98.2). For both sampling modalities, sensitivity was higher in participants with symptom duration ≤ 3days versus ≤ 7days. Agreement between nasal and nasopharyngeal Ag-RDT was 99.4%. CONCLUSIONS: The STANDARD Q Ag-RDT showed high specificity. Sensitivity was, however, below the WHO recommended minimum requirement of ≥ 80%. The high agreement between nasal and nasopharyngeal sampling suggests that for Ag-RDT nasal sampling is a good alternative to nasopharyngeal sampling.


Subject(s)
COVID-19 , SARS-CoV-2 , Child , Female , Humans , Adult , Male , Lesotho , COVID-19/diagnosis , Nose , Nasopharynx
11.
Nat Genet ; 55(1): 26-33, 2023 01.
Article in English | MEDLINE | ID: mdl-36624344

ABSTRACT

The first step in SARS-CoV-2 genomic surveillance is testing to identify people who are infected. However, global testing rates are falling as we emerge from the acute health emergency and remain low in many low- and middle-income countries (mean = 27 tests per 100,000 people per day). We simulated COVID-19 epidemics in a prototypical low- and middle-income country to investigate how testing rates, sampling strategies and sequencing proportions jointly impact surveillance outcomes, and showed that low testing rates and spatiotemporal biases delay time to detection of new variants by weeks to months and can lead to unreliable estimates of variant prevalence, even when the proportion of samples sequenced is increased. Accordingly, investments in wider access to diagnostics to support testing rates of approximately 100 tests per 100,000 people per day could enable more timely detection of new variants and reliable estimates of variant prevalence. The performance of global SARS-CoV-2 genomic surveillance programs is fundamentally limited by access to diagnostic testing.


Subject(s)
COVID-19 , Epidemics , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/genetics , Genomics , Diagnostic Techniques and Procedures , COVID-19 Testing
12.
Clin Infect Dis ; 76(4): 620-630, 2023 02 18.
Article in English | MEDLINE | ID: mdl-36208211

ABSTRACT

BACKGROUND: Increasing the availability of antigen rapid diagnostic tests (Ag-RDTs) in low- and middle-income countries (LMICs) is key to alleviating global SARS-CoV-2 testing inequity (median testing rate in December 2021-March 2022 when the Omicron variant was spreading in multiple countries: high-income countries = 600 tests/100 000 people/day; LMICs = 14 tests/100 000 people/day). However, target testing levels and effectiveness of asymptomatic community screening to impact SARS-CoV-2 transmission in LMICs are unclear. METHODS: We used Propelling Action for Testing and Treating (PATAT), an LMIC-focused agent-based model to simulate coronavirus disease 2019 (COVID-19) epidemics, varying the amount of Ag-RDTs available for symptomatic testing at healthcare facilities and asymptomatic community testing in different social settings. We assumed that testing was a function of access to healthcare facilities and availability of Ag-RDTs. We explicitly modelled symptomatic testing demand from individuals without SARS-CoV-2 and measured impact based on the number of infections averted due to test-and-isolate. RESULTS: Testing symptomatic individuals yields greater benefits than any asymptomatic community testing strategy until most symptomatic individuals who sought testing have been tested. Meeting symptomatic testing demand likely requires at least 200-400 tests/100 000 people/day, on average, as symptomatic testing demand is highly influenced by individuals without SARS-CoV-2. After symptomatic testing demand is satisfied, excess tests to proactively screen for asymptomatic infections among household members yield the largest additional infections averted. CONCLUSIONS: Testing strategies aimed at reducing transmission should prioritize symptomatic testing and incentivizing test-positive individuals to adhere to isolation to maximize effectiveness.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/prevention & control , Developing Countries , COVID-19 Testing , Rapid Diagnostic Tests , Zambia
13.
Microbiol Spectr ; 10(5): e0122922, 2022 10 26.
Article in English | MEDLINE | ID: mdl-36066256

ABSTRACT

Access to reverse transcription-PCR (RT-PCR) testing, the gold standard for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection, is limited throughout the world, due to restricted resources, available infrastructure, and high costs. Antigen-detecting rapid diagnostic tests (Ag-RDTs) overcome some of these barriers, but independent clinical validations in settings of intended use are scarce. To inform the World Health Organization's (WHO) emergency use listing (EUL) procedure and ensure affordable, high-quality Ag-RDTs, we assessed the performance and ease of use of the SureStatus for SARS-CoV-2. For this prospective, multicenter diagnostic accuracy study, we recruited unvaccinated participants with presumed SARS-CoV-2 infection in India and Germany from December 2020 to March 2021, when the Alpha (B.1.1.7) variant was predominantly circulating. Paired swabs were performed for (i) routine clinical RT-PCR testing (sampling was either nasopharyngeal [NP] or combined NP and oropharyngeal [NP/OP]) and (ii) Ag-RDT (sampling was NP). Performance of the Ag-RDT was compared to RT-PCR overall and by predefined subgroups, e.g., cycle threshold (CT) value, symptoms, and days from symptom onset. To understand the usability, a system usability scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. A total of 1,119 participants were included in the analysis, of whom 205 (18.3%) were RT-PCR positive. SureStatus detected 169 out of 205 RT-PCR-positive participants, reporting a sensitivity of 82.4% (95% confidence interval [CI]: 76.6% to 87.1%) and a specificity of 98.5% (95% CI: 97.4% to 99.1%). In the first 7 days post-symptom onset, the sensitivity was 90.7% (95% CI: 83.5% to 94.9%), when CT values were low and viral loads were high. The test was characterized as easy to use (SUS, 85/100) and considered suitable for point-of-care settings, although quality concerns were raised due to visibly contaminated packaging of swabs included in the test kits. The SureStatus diagnostic test can be considered a reliable test during the first week of SARS-CoV-2 infection, with high sensitivity in combination with excellent usability. IMPORTANCE Our manufacturer-independent, prospective diagnostic accuracy study assessed clinical performance in participants presumed to have a SARS-CoV-2 infection at three study sites in two countries. We assessed the accuracy overall and in predefined subgroups (CT values and symptom duration). SureStatus performed with high sensitivity. Its sensitivity was particularly high in the first 3 days after symptom onset and when CT values were low (i.e., the viral load was high). The system usability and ease-of-use assessment complements the accuracy assessment of the test and highlights critical factors to facilitate the widespread use of SureStatus in point-of-care settings. The high sensitivity demonstrated by the evaluated Ag-RDT within the first days of symptoms, when most transmission occurs, supports the role of Ag-RDTs for public health-relevant screening. Evidence from this study was used to inform the World Health Organization Emergency Use Listing procedure.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , SARS-CoV-2/genetics , COVID-19/diagnosis , Diagnostic Tests, Routine , Point-of-Care Systems , Prospective Studies , Sensitivity and Specificity , World Health Organization
14.
medRxiv ; 2022 Sep 16.
Article in English | MEDLINE | ID: mdl-35664998

ABSTRACT

The first step in SARS-CoV-2 genomic surveillance is testing to identify infected people. However, global testing rates are falling as we emerge from the acute health emergency and remain low in many low- and middle-income countries (LMICs) (mean = 27 tests/100,000 people/day). We simulated COVID-19 epidemics in a prototypical LMIC to investigate how testing rates, sampling strategies, and sequencing proportions jointly impact surveillance outcomes and showed that low testing rates and spatiotemporal biases delay time-to-detection of new variants by weeks-to-months and can lead to unreliable estimates of variant prevalence even when the proportion of samples sequenced is increased. Accordingly, investments in wider access to diagnostics to support testing rates of ~100 tests/100,000 people/day could enable more timely detection of new variants and reliable estimates of variant prevalence. The performance of global SARS-CoV-2 genomic surveillance programs is fundamentally limited by access to diagnostic testing.

15.
PLoS One ; 17(6): e0268127, 2022.
Article in English | MEDLINE | ID: mdl-35771878

ABSTRACT

OBJECTIVE: Over the past several years, only approximately 50% of HIV-exposed infants received an early infant diagnosis test within the first two months of life. While high attrition and mortality account for some of the shortcomings in identifying HIV-infected infants early and putting them on life-saving treatment, fragmented and challenging laboratory systems are an added barrier. We sought to determine the accuracy of using HIV viral load assays for infant diagnosis of HIV. METHODS: We enrolled 866 Ugandan infants between March-April 2018 for this study after initial laboratory diagnosis. The median age was seven months, while 33% of infants were less than three months of age. Study testing was done using either the Roche or Abbott molecular technologies at the Central Public Health Laboratory. Dried blood spot samples were prepared according to manufacturer-recommended protocols for both the qualitative and quantitative assays. Viral load test samples for the Roche assay were processed using two different buffers: phosphate-buffered saline (PBS: free virus elution viral load protocol [FVE]) and Sample Pre-Extraction Reagent (SPEX: qualitative buffer). Dried blood spot samples were processed for both assays on the Abbott using the manufacturer's standard infant diagnosis protocol. All infants received a qualitative test for clinical management and additional paired quantitative tests. RESULTS: 858 infants were included in the analysis, of which 50% were female. Over 75% of mothers received antiretroviral therapy, while approximately 65% of infants received infant prophylaxis. The Roche SPEX and Abbott technologies had high sensitivity (>95%) and specificity (>98%). The Roche FVE had lower sensitivity (85%) and viral load values. CONCLUSIONS: To simplify and streamline laboratory practices, HIV viral load may be used to diagnose HIV infection in infants, particularly using the Roche SPEX and Abbott technologies.


Subject(s)
HIV Infections , HIV-1 , Female , HIV Testing , HIV-1/genetics , Humans , Infant , Male , RNA, Viral , Sensitivity and Specificity , Viral Load/methods
16.
PLoS Med ; 19(5): e1004011, 2022 05.
Article in English | MEDLINE | ID: mdl-35617375

ABSTRACT

BACKGROUND: Comprehensive information about the accuracy of antigen rapid diagnostic tests (Ag-RDTs) for Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) is essential to guide public health decision makers in choosing the best tests and testing policies. In August 2021, we published a systematic review and meta-analysis about the accuracy of Ag-RDTs. We now update this work and analyze the factors influencing test sensitivity in further detail. METHODS AND FINDINGS: We registered the review on PROSPERO (registration number: CRD42020225140). We systematically searched preprint and peer-reviewed databases for publications evaluating the accuracy of Ag-RDTs for SARS-CoV-2 until August 31, 2021. Descriptive analyses of all studies were performed, and when more than 4 studies were available, a random-effects meta-analysis was used to estimate pooled sensitivity and specificity with reverse transcription polymerase chain reaction (RT-PCR) testing as a reference. To evaluate factors influencing test sensitivity, we performed 3 different analyses using multivariable mixed-effects meta-regression models. We included 194 studies with 221,878 Ag-RDTs performed. Overall, the pooled estimates of Ag-RDT sensitivity and specificity were 72.0% (95% confidence interval [CI] 69.8 to 74.2) and 98.9% (95% CI 98.6 to 99.1). When manufacturer instructions were followed, sensitivity increased to 76.3% (95% CI 73.7 to 78.7). Sensitivity was markedly better on samples with lower RT-PCR cycle threshold (Ct) values (97.9% [95% CI 96.9 to 98.9] and 90.6% [95% CI 88.3 to 93.0] for Ct-values <20 and <25, compared to 54.4% [95% CI 47.3 to 61.5] and 18.7% [95% CI 13.9 to 23.4] for Ct-values ≥25 and ≥30) and was estimated to increase by 2.9 percentage points (95% CI 1.7 to 4.0) for every unit decrease in mean Ct-value when adjusting for testing procedure and patients' symptom status. Concordantly, we found the mean Ct-value to be lower for true positive (22.2 [95% CI 21.5 to 22.8]) compared to false negative (30.4 [95% CI 29.7 to 31.1]) results. Testing in the first week from symptom onset resulted in substantially higher sensitivity (81.9% [95% CI 77.7 to 85.5]) compared to testing after 1 week (51.8%, 95% CI 41.5 to 61.9). Similarly, sensitivity was higher in symptomatic (76.2% [95% CI 73.3 to 78.9]) compared to asymptomatic (56.8% [95% CI 50.9 to 62.4]) persons. However, both effects were mainly driven by the Ct-value of the sample. With regards to sample type, highest sensitivity was found for nasopharyngeal (NP) and combined NP/oropharyngeal samples (70.8% [95% CI 68.3 to 73.2]), as well as in anterior nasal/mid-turbinate samples (77.3% [95% CI 73.0 to 81.0]). Our analysis was limited by the included studies' heterogeneity in viral load assessment and sample origination. CONCLUSIONS: Ag-RDTs detect most of the individuals infected with SARS-CoV-2, and almost all (>90%) when high viral loads are present. With viral load, as estimated by Ct-value, being the most influential factor on their sensitivity, they are especially useful to detect persons with high viral load who are most likely to transmit the virus. To further quantify the effects of other factors influencing test sensitivity, standardization of clinical accuracy studies and access to patient level Ct-values and duration of symptoms are needed.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Point-of-Care Systems , Sensitivity and Specificity
18.
AIDS ; 36(5): 711-719, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35025819

ABSTRACT

OBJECTIVES: Assess whether near-point-of-care (POC) viral load testing at the first antenatal care visit (ANC1) increased the proportion of women taking antiretroviral therapy who were virally suppressed at delivery through expedited clinical action. DESIGN: Difference-in-difference analysis. METHODS: At 20 public sector facilities in Zimbabwe, 10 implemented near-POC viral load testing at ANC1 (August 2019 to November 2020) and 10 used centralized viral load testing at ANC1. Study endpoints included time to result received, clinical action, and unsuppressed viral load (UVL; >1000 copies/ml) at delivery. RESULTS: Of 1782 women, only 46% came for ANC1 before their third trimester. Preimplementation, 28% of women received viral load testing at ANC1, increasing to 86% during implementation. In the near-POC viral load arm, women were more likely to receive their result within 30 days of ANC1 sample collection compared with the centralized laboratory arm [54 versus 14%, relative risk (RR): 4.17, 95% confidence interval (CI) 1.82-9.55], as well as receive clinical action among those with UVL (63 versus 8%, RR 7.88; 95% CI 1.53-40.47). However, we did not observe significant changes in risk of UVL at delivery with near-POC viral load (RR 1.02, 95% CI 0.95-1.10). CONCLUSION: ANC1 viral load coverage was initially low. Near-POC viral load testing at ANC1 dramatically improved the timeliness of result receipt by patients and clinical action for those with an UVL. Although we did not observe a significant impact of provision of near-POC viral load at ANC1 on re-suppression at delivery, potentially because of late presentation for ANC1, continued near-POC viral load testing during pregnancy and delivery may reduce UVL and mother-to-child transmission risk.


Subject(s)
HIV Infections , Point-of-Care Systems , Female , HIV Infections/diagnosis , HIV Infections/drug therapy , Humans , Infectious Disease Transmission, Vertical/prevention & control , Male , Point-of-Care Testing , Pregnancy , Viral Load/methods , Viremia/diagnosis
20.
Infection ; 50(2): 395-406, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34383260

ABSTRACT

PURPOSE: Rapid antigen-detecting tests (Ag-RDTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can transform pandemic control. Thus far, sensitivity (≤ 85%) of lateral-flow assays has limited scale-up. Conceivably, microfluidic immunofluorescence Ag-RDTs could increase sensitivity for SARS-CoV-2 detection. METHODS: This multi-centre diagnostic accuracy study investigated performance of the microfluidic immunofluorescence LumiraDx™ assay, enrolling symptomatic and asymptomatic participants with suspected SARS-CoV-2 infection. Participants collected a supervised nasal mid-turbinate (NMT) self-swab for Ag-RDT testing, in addition to a professionally collected nasopharyngeal (NP) swab for routine testing with reverse transcriptase polymerase chain reaction (RT-PCR). Results were compared to calculate sensitivity and specificity. Sub-analyses investigated the results by viral load, symptom presence and duration. An analytical study assessed exclusivity and limit-of-detection (LOD). In addition, we evaluated ease-of-use. RESULTS: The study was conducted between November 2nd 2020 and 4th of December 2020. 761 participants were enrolled, with 486 participants reporting symptoms on testing day. 120 out of 146 RT-PCR positive cases were detected positive by LumiraDx™, resulting in a sensitivity of 82.2% (95% CI 75.2-87.5%). Specificity was 99.3% (CI 98.3-99.7%). Sensitivity was increased in individuals with viral load ≥ 7 log10 SARS-CoV2 RNA copies/ml (93.8%; CI 86.2-97.3%). Testing against common respiratory commensals and pathogens showed no cross-reactivity and LOD was estimated to be 2-56 PFU/mL. The ease-of-use-assessment was favourable for lower throughput settings. CONCLUSION: The LumiraDx™ assay showed excellent analytical sensitivity, exclusivity and clinical specificity with good clinical sensitivity using supervised NMT self-sampling. TRIAL REGISTRATION NUMBER AND REGISTRATION DATE: DRKS00021220 and 01.04.2020.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Pandemics , Point-of-Care Systems , RNA, Viral , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...