Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 175
Filter
2.
Bioact Mater ; 38: 73-94, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38699240

ABSTRACT

Sutureless anastomotic devices present several advantages over traditional suture anastomosis, including expanded global access to microvascular surgery, shorter operation and ischemic times, and reduced costs. However, their adaptation for arterial use remains a challenge. This review aims to provide a comprehensive overview of sutureless anastomotic approaches that are either FDA-approved or under investigation. These approaches include extraluminal couplers, intraluminal devices, and methods assisted by lasers or vacuums, with a particular emphasis on tissue adhesives. We analyze these devices for artery compatibility, material composition, potential for intimal damage, risks of thrombosis and restenosis, and complications arising from their deployment and maintenance. Additionally, we discuss the challenges faced in the development and clinical application of sutureless anastomotic techniques. Ideally, a sutureless anastomotic device or technique should eliminate the need for vessel eversion, mitigate thrombosis through either biodegradation or the release of antithrombotic drugs, and be easily deployable for broad use. The transformative potential of sutureless anastomotic approaches in microvascular surgery highlights the necessity for ongoing innovation to expand their applications and maximize their benefits.

3.
Biomaterials ; 308: 122563, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38574456

ABSTRACT

A vascular anastomosis is a critical surgical skill that involves connecting blood vessels. Traditional handsewn techniques can be challenging and resource intensive. To address these issues, we have developed a unique sutureless anastomotic device called Vaso-Lock. This intraluminal device connects free vascular ends using anchors to maintain traction and enable a rapid anastomosis. We tested the anastomotic capability of Vaso-Locks in a pig common carotid-internal jugular arteriovenous model. The use of Vaso-Lock allowed us to accomplish this procedure in less than 10 min, in contrast to the approximately 40 min required for a handsewn anastomosis. The Vaso-Lock effectively maintained patency for at least 6 weeks without causing significant tissue damage. Histological analysis revealed that the device was successfully incorporated into the arterial wall, promoting a natural healing process. Additionally, organ evaluations indicated no adverse effects from using the Vaso-Lock. Our findings support the safety and effectiveness of the Vaso-Lock for arteriovenous anastomosis in pigs, with potential applicability for translation to humans. Our novel sutureless device has the potential to advance surgical practice and improve patient outcomes.


Subject(s)
Anastomosis, Surgical , Animals , Swine , Sutureless Surgical Procedures/methods , Arteriovenous Anastomosis/surgery , Vascular Patency
4.
Mater Today Commun ; 392024 Jun.
Article in English | MEDLINE | ID: mdl-38618226

ABSTRACT

Synthetic polymers are often utilized in the creation of vascular devices, and need to possess specific qualities to prevent thrombosis. Traditional strategies for this include surface modification of vascular devices through covalent attachment of substrates such as heparin, antiplatelet agents, thrombolytic agents, or hydrophilic polymers. One promising prosthetic material is polyether ether ketone (PEEK), which is utilized in various FDA-approved medical devices, including vascular and endovascular prostheses. We hypothesized that surface modification of biologically inert PEEK can help improve its endothelial cell affinity and reduce its thrombogenic potential. To evaluate this, we developed an effective surface-modification approach with unique cyclic peptides, such as CCHGGVRLYC and CCREDVC. We treated the PEEK surface with ammonia plasma, which introduced amine groups onto the PEEK surface. Subsequently, we were able to conjugate these peptides to the plasma-modified PEEKs. We observed that cyclic CCHGGVRLYC conjugated on prosthetic PEEK not only supported endothelialization, but minimized platelet adhesion and activation. This technology can be potentially applied for in vivo vascular and endovascular protheses to enhance their utility and patency.

5.
J Plast Reconstr Aesthet Surg ; 89: 154-163, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38199217

ABSTRACT

BACKGROUND: Online resources are commonly used by patients to obtain information on breast reconstruction. Despite the key role of these resources in patient decision-making, their visual content has not yet been evaluated. This study sought to 1) characterize the presence and content of visual aids in online patient education breast reconstruction resources and 2) determine if the women represented in these visual aids reflect the breast reconstruction patient population in the United States. METHODS: The top 10 Google websites and the first 400 Google Images containing photographs/graphics depicting human skin for the search phrase "breast reconstruction" were analyzed. Images were categorized by content as "Before/After," "Surgical/Anatomical," "Step-by-Step," or "Breast-Centric Stock Images." Image subjects were classified by skin tone into "White" or "Non-White" using the Fitzpatrick scale and by body type into "Lean" or "Full-Figured." RESULTS: In total, 471 images were analyzed. These were predominantly "Before/After" images (43.9%), followed by "Breast-Centric Stock Images" (27.4%), "Surgical/Anatomical" (24.2%), and "Step-by-Step" (4.5%). The majority of all images depicted "White" skin types (90.7%) and "Lean" body types (73.0%). "Before/After" images were more likely to show "Full-Figured" women than the other content categories (p < 0.0001) and had the highest percentage of "Non-White" skin types (35.3%). CONCLUSIONS: Our findings demonstrate that breast reconstruction online resources are not reflective of the patient population seeking reconstruction. Improving the diversity of online image resources can both better represent our diverse patient population as well as better align patient expectations with postoperative outcomes, likely improving patient satisfaction.


Subject(s)
Breast Neoplasms , Mammaplasty , Humans , Female , United States , Decision Making , Skin , Breast , Patient Satisfaction , Breast Neoplasms/surgery
6.
J Reconstr Microsurg ; 40(3): 177-185, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37236242

ABSTRACT

BACKGROUND: This study assesses associations between bioimpedance spectroscopy (BIS) and magnetic resonance lymphangiography (MRL) in the staging and assessment of lymphedema. METHODS: Adults who received MRL and BIS between 2020 and 2022 were included. We collected fluid, fat, and lymphedema severity ratings, and measured fluid stripe thickness, subcutaneous fat width, and lymphatic diameter on MRL. BIS lymphedema index (L-Dex) scores were collected from patient charts. We assessed sensitivity and specificity of L-Dex scores to detect MRL-identified lymphedema, and examined associations between L-Dex scores and MRL imaging measures. RESULTS: Forty-eight limbs across 40 patients were included. L-Dex scores had 72.5% sensitivity and 87.5% specificity for detecting MRL-defined lymphedema, with a 96.7% estimated positive predictive value and 38.9% negative predictive value. L-Dex scores were associated with MRL fluid and fat content scores (p ≤ 0.05), and lymphedema severity (p = 0.01), with better discrimination between fluid than fat content levels on pairwise analysis, and poor discrimination between adjacent severity levels. L-Dex scores were correlated with distal and proximal limb fluid stripe thickness (distal: rho = 0.57, p < 0.01; proximal: rho = 0.58, p < 0.01), partially correlated with distal subcutaneous fat thickness when accounting for body mass index (rho = 0.34, p = 0.02), and were not correlated with lymphatic diameter (p = 0.25). CONCLUSION: L-Dex scores have high sensitivity, specificity, and positive predictive value for the identification of MRL-detected lymphedema. L-Dex has difficulty distinguishing between adjacent severity levels of lymphedema and a high false negative rate, explained in part by reduced discrimination between levels of fat accumulation.


Subject(s)
Lymphatic Vessels , Lymphedema , Adult , Humans , Lymphography/methods , Lymphedema/pathology , Magnetic Resonance Imaging/methods , Lymphatic Vessels/pathology , Magnetic Resonance Spectroscopy
7.
Plast Reconstr Surg ; 153(1): 101e-111e, 2024 01 01.
Article in English | MEDLINE | ID: mdl-37189241

ABSTRACT

BACKGROUND: Upper extremity (UE) trauma requiring operative care increases during the summer and fall months, which the authors colloquially refer to as "trauma season." METHODS: CPT databases were queried for codes related to acute UE trauma at a single level-1 trauma center. Monthly CPT code volume was tabulated for 120 consecutive months and average monthly volume was calculated. Raw data were plotted as a time series and transformed as a ratio to the moving average. Autocorrelation was applied to the transformed data set to detect yearly periodicity. Multivariable modeling quantified the proportion of volume variability attributable to yearly periodicity. Subanalysis assessed presence and strength of periodicity in four age groups. RESULTS: A total of 11,084 CPT codes were included. Monthly trauma-related CPT volume was highest in July through October and lowest in December through February. Time-series analysis revealed yearly oscillation in addition to a growth trend. Autocorrelation revealed statistically significant positive and negative peaks at a lag of 12 and 6 months, respectively, confirming yearly periodicity. Multivariable modeling revealed R 2 attributable to periodicity of 0.53 ( P < 0.01). Periodicity was strongest in younger populations and weaker in older populations. R 2 was 0.44 for ages 0 to 17, 0.35 for ages 18 to 44, 0.26 for ages 45 to 64, and 0.11 for ages 65 and older. CONCLUSIONS: Operative UE trauma volumes peak in the summer and early fall and reach a winter nadir. Periodicity accounts for 53% of trauma volume variability. The authors' findings have implications for allocation of operative block time and personnel and expectation management over the course of the year.


Subject(s)
Arm Injuries , Humans , Aged , Seasons , Retrospective Studies , Upper Extremity/surgery
8.
Plast Reconstr Surg ; 153(4): 967-975, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-37199437

ABSTRACT

SUMMARY: A biosensor uses a biological molecule to measure a chemical reaction. Wearable biosensors that attach to the body externally, including tooth enamel biosensors, contact lens biosensors, sweat biosensors, and skin tattoo biosensors, are in development. Nanoparticle-based biosensors are being developed to allow for the early detection of cancerous biomarkers. Applications relevant to plastic surgery include the development of biosensors that can detect metastatic breast cancer cells, bioimpedance spectroscopy, and intraoperative point-of-care diagnostics.


Subject(s)
Biosensing Techniques , Humans , Biosensing Techniques/methods
9.
Plast Reconstr Surg ; 153(1): 204e-217e, 2024 01 01.
Article in English | MEDLINE | ID: mdl-37075274

ABSTRACT

SUMMARY: Artificial intelligence (AI) has been a disruptive technology within health care, from the development of simple care algorithms to complex deep-learning models. AI has the potential to reduce the burden of administrative tasks, advance clinical decision-making, and improve patient outcomes. Unlocking the full potential of AI requires the analysis of vast quantities of clinical information. Although AI holds tremendous promise, widespread adoption within plastic surgery remains limited. Understanding the basics is essential for plastic surgeons to evaluate the potential uses of AI. This review provides an introduction of AI, including the history of AI, key concepts, applications of AI in plastic surgery, and future implications.


Subject(s)
Plastic Surgery Procedures , Surgeons , Humans , Artificial Intelligence , Algorithms , Delivery of Health Care
11.
J Reconstr Microsurg ; 2023 Dec 18.
Article in English | MEDLINE | ID: mdl-37884060

ABSTRACT

BACKGROUND: Augmented reality (AR) and virtual reality (VR)-termed mixed reality-have shown promise in the care of operative patients. Currently, AR and VR have well-known applications for craniofacial surgery, specifically in preoperative planning. However, the application of AR/VR technology to other reconstructive challenges has not been widely adopted. Thus, the purpose of this investigation is to outline the current applications of AR and VR in the operative setting. METHODS: The literature pertaining to the use of AR/VR technology in the operative setting was examined. Emphasis was placed on the use of mixed reality technology in surgical subspecialities, including plastic surgery, oral and maxillofacial surgery, colorectal surgery, neurosurgery, otolaryngology, neurosurgery, and orthopaedic surgery. RESULTS: Presently, mixed reality is widely used in the care of patients requiring complex reconstruction of the craniomaxillofacial skeleton for pre- and intraoperative planning. For upper extremity amputees, there is evidence that VR may be efficacious in the treatment of phantom limb pain. Furthermore, VR has untapped potential as a cost-effective tool for microsurgical education and for training residents on techniques in surgical and nonsurgical aesthetic treatment. There is utility for mixed reality in breast reconstruction for preoperative planning, mapping perforators, and decreasing operative time. VR has well- documented applications in the planning of deep inferior epigastric perforator flaps by creating three-dimensional immersive simulations based on a patient's preoperative computed tomography angiogram. CONCLUSION: The benefits of AR and VR are numerous for both patients and surgeons. VR has been shown to increase surgical precision and decrease operative time. Furthermore, it is effective for patient-specific rehearsal which uses the patient's exact anatomical data to rehearse the procedure before performing it on the actual patient. Taken together, AR/VR technology can improve patient outcomes, decrease operative times, and lower the burden of care on both patients and health care institutions.

12.
Plast Reconstr Surg Glob Open ; 11(10): e5345, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37850199

ABSTRACT

Background: Weekend presentation has been associated with adverse outcomes in emergent conditions, including stroke, myocardial infarction, and critical limb ischemia. We examine whether a weekend effect exists in the management of and outcomes after extremity degloving injuries. Methods: The cohort included adults presenting with open extremity degloving injuries to a tertiary level one trauma center between June 2018 and May 2022. We collected demographics, comorbidities, injury information, interventions, and complications. Propensity score weighting was used to minimize confounding differences between those presenting on weekends (Sat-Sun) versus weekdays (Mon-Fri). Weighted regressions were used to examine differences in interventions by day of presentation. Multivariable weighted regressions accounting for differences in interventions received were used to examine whether weekend presentation was associated with amputation risk, complications, or functional deficits. Results: Ninety-five patients with 100 open extremity degloving injuries were included. In total, 39% of injuries were weekend-presenting. There was a higher rate of noninsulin-dependent diabetes among patients presenting on weekends (P = 0.03). Weekend-presenting injuries had higher median Injury Severity Scores (P = 0.04). Propensity-weighted regression analysis revealed differences in interventions received on weekends, including lower rates of pedicled and free flaps and bone graft, and increased rates of negative-pressure wound therapy (P ≤ 0.02). Multivariable regression analysis revealed weekend presentation was a significant independent risk factor for amputation of the affected extremity [odds ratio 2.27, 95% CI (1.01-5.33), P = 0.05]. Conclusion: Weekend presentation may impact interventions received and amputation risk in patients presenting with open extremity degloving injuries.

13.
Plast Reconstr Surg Glob Open ; 11(8): e5209, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37593701

ABSTRACT

Background: Innovation is an essential aspect of plastic and reconstructive surgery (PRS), whether it involves improving current processes or implementing radical change that disrupts the status quo. Collaborating and sharing innovations help advance the field of PRS as a whole. Methods: An anonymous survey was administered to members of the American Association of Plastic Surgeons on their opinions of the top five innovations in PRS of the last 100 years. Results: A list of 69 unique innovations were compiled; the top five innovations overall were microsurgery, myocutaneous flaps, craniofacial surgery, negative pressure wound therapy, and organ transplantation. This list was reviewed by the American Association of Plastic Surgeons Technology Committee, and expanded to 100 unique innovations. Conclusions: We discuss why the above innovations were essential to the development of PRS, as well as the unique factors that can make a new product or procedure into something that remodels the field of PRS.

14.
Oper Neurosurg (Hagerstown) ; 25(5): 469-477, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37584482

ABSTRACT

BACKGROUND AND OBJECTIVE: Rapid design and production of patient-specific 3-dimensional-printed implants (3DPIs) present a novel opportunity to restore the biomechanically demanding integrity of the lumbopelvic junction. We present a unique case of a 61-year-old patient with severe neuropathic spinal arthropathy (Charcot spine) who initially underwent a T4-to-sacrum spinal fusion. Massive bone destruction led to dissociation of his upper body from his pelvis and legs. Reconstruction of the spinopelvic continuity was planned with the aid of a personalized lumbosacral 3DPI. METHOD: Using high-resolution computed tomography scans, the custom 3DPI was made using additive titanium manufacturing. The unique 3DPI consisted of (1) a sacral platform with iliac screws, (2) modular corpectomy device with rigid connection to the sacral platform, and (3) anterior plate connection with screws for proximal fixation. The procedures to obtain compassionate use Food and Drug Administration approval were followed. The patient underwent debridement of a chronically open wound before undertaking the 3-stage reconstructive procedure. The custom 3DPI and additional instrumentation were inserted as part of a salvage rebuilding procedure. RESULTS: The chronology of the rapid implementation of the personalized sacral 3DPI from decision, design, manufacturing, Food and Drug Administration approval, and surgical execution lasted 28 days. The prosthesis was positioned in the defect according to the expected anatomic planes and secured using a screw-rod system and a vascularized fibular bone strut graft. The prosthesis provided an ideal repair of the lumbosacral junction and pelvic ring by merging spinal pelvic fixation, posterior pelvic ring fixation, and anterior spinal column fixation. CONCLUSION: To the best of our knowledge, this is the first case of a multilevel lumbar, sacral, and sacropelvic neuropathic (Charcot) spine reconstruction using a 3DPI sacral prosthesis. As the prevalence of severe spine deformities continues to increase, adoption of 3DPIs is becoming more relevant to offer personalized treatment for complex deformities.


Subject(s)
Joint Diseases , Sacrum , United States , Humans , Middle Aged , Sacrum/diagnostic imaging , Sacrum/surgery , Titanium , Pelvis , Bone Screws
15.
Plast Reconstr Surg Glob Open ; 11(7): e5113, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37441113

ABSTRACT

In breast reconstruction, mastectomy and free flaps are susceptible to vascular compromise and tissue necrosis. The SnapshotNIR device (Kent Imaging, Calgary, AB, Canada) utilizes near-infrared spectroscopy to measure tissue oxygen saturation (StO2) and hemoglobin concentration. Here, we report on the use of this device for StO2 monitoring among patients receiving alloplastic or autologous breast reconstruction. Methods: Patients receiving immediate alloplastic reconstruction after mastectomy or autologous reconstruction were enrolled. Preoperative, intraoperative, and postoperative images were taken of the flaps. StO2 and hemoglobin were measured at the following locations: superior and inferior breast, free flap skin paddle (when applicable), and un-operated control skin. Linear mixed effects model for repeated measurements was used to model measurements to estimate the area effect difference across time, time effect difference across area, and pairwise comparisons between two areas at each time point. Results: Thirty-two breasts underwent alloplastic reconstruction; 38 breasts underwent autologous reconstruction. No enrollees developed skin necrosis. StO2 was highest after mastectomy and closure in alloplastic reconstructions. StO2 was observed to decline at follow-up in autologous reconstructions. Mean preoperative StO2 was highest in breasts that had previously undergone mastectomy and alloplastic reconstruction. Conclusions: The SnapshotNIR device detected normal spatial and temporal differences in tissue oxygenation over the operative course of alloplastic and autologous breast reconstruction. A multi-institutional, prospective clinical trial is needed to determine the sensitivity and specificity of this device for detecting skin flap necrosis.

16.
Plast Reconstr Surg ; 152(1): 236-238, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37382920

ABSTRACT

SUMMARY: This article is an introduction to the new PRS Tech Disruptor Series, the culmination of work originating from the Technology Innovation and Disruption Presidential Task Force. Our technology quotient is important to our success as individuals and as a specialty society. The goal of this new series is to address the broader concepts in technology as they relate to plastic surgery and thus enhance the technology quotient of readers and, in turn, of the specialty and specialty society. Critical topics related to technology, their current and future impact on plastic surgery, and the opportunities and barriers in research, education, and advocacy will be addressed. The intent is for readers to engage in dialogue and think outside the box about the current and future impact of technology.


Subject(s)
Plastic Surgery Procedures , Surgery, Plastic , Humans , Technology , Advisory Committees , Intelligence
17.
Plast Reconstr Surg ; 152(1): 239-249, 2023 07 01.
Article in English | MEDLINE | ID: mdl-37382921

ABSTRACT

SUMMARY: Although robotic surgery has been routinely established in other surgical disciplines, robotic technologies have been less readily adopted in plastic surgery. Despite a strong demand for innovation and cutting-edge technology in plastic surgery, most reconstructive procedures, including microsurgery, have continued to necessitate an open approach. Recent advances in robotics and artificial intelligence, however, are gaining momentum and have shown significant promise to improve patient care in plastic surgery. These next-generation surgical robots have the potential to enable surgeons to perform complex procedures with greater precision, flexibility, and control than previously possible with conventional techniques. Successful integration of robotic technologies into clinical practice in plastic surgery requires achieving key milestones, including implementing appropriate surgical education and garnering patient trust.


Subject(s)
Plastic Surgery Procedures , Robotic Surgical Procedures , Robotics , Surgery, Plastic , Humans , Artificial Intelligence
18.
J Plast Reconstr Aesthet Surg ; 83: 258-265, 2023 08.
Article in English | MEDLINE | ID: mdl-37285777

ABSTRACT

BACKGROUND: Previous studies in orthopedics and general surgery have linked negative patient outcomes with preoperative opioid use. In this study, we investigated the association of preoperative opioid use on breast reconstruction outcomes and quality of life (QoL). METHODS: We reviewed our prospective registry of patients who underwent breast reconstruction for documented preoperative opioid use. Postoperative complications were recorded at 60 days after the first reconstructive surgery and 60 days after the final staged reconstruction. We used a logistic regression model to assess the association between opioid use and postoperative complications, controlling for smoking, age, laterality, BMI, comorbidities, radiation, and previous breast surgery; linear regression to analyze RAND36 scores to evaluate the impact of preoperative opioid use on postoperative QoL, controlling for the same factors; and Pearson chi-squared test to assess factors that may be associated with opioid use. RESULTS: Of the 354 patients eligible for inclusion, 29 (8.2%) were prescribed preoperative opioids. There were no differences in opioid use by race, BMI, comorbidities, previous breast surgery, or laterality. Preoperative opioids were associated with increased odds of postoperative complications within 60 days after the first reconstructive surgery (OR: 6.28; 95% CI: 1.69-23.4; p = 0.006) and within 60 days after the final staged reconstruction (OR: 8.38; 95% CI: 1.17-59.4; p = 0.03). Among patients using opioids preoperatively, the RAND36 physical and mental scores decreased but were not statistically significant. CONCLUSION: We found that preoperative opioid use is associated with increased odds of postoperative complications among patients who underwent breast reconstruction and may contribute to clinically significant declines in postoperative QoL.


Subject(s)
Breast Neoplasms , Mammaplasty , Opioid-Related Disorders , Humans , Female , Analgesics, Opioid/adverse effects , Quality of Life , Pain, Postoperative/drug therapy , Pain, Postoperative/etiology , Postoperative Complications/etiology , Postoperative Complications/chemically induced , Mammaplasty/adverse effects , Breast Neoplasms/surgery , Breast Neoplasms/complications , Retrospective Studies
19.
J Surg Res ; 291: 116-123, 2023 11.
Article in English | MEDLINE | ID: mdl-37356340

ABSTRACT

INTRODUCTION: Vascular reconstruction requires technical expertise and is often time consuming. As a novel alternative to traditional hand-sewn vascular anastomoses, the VasoLock (VL), is a nonabsorbable, sutureless anastomosis device with traction anchors designed to hold free artery ends together. These anchors do not penetrate the vessel wall but adhere by leveraging the elasticity of the vessels to fasten blood vessels together. This pilot study assesses the performance and patency of this novel device in a porcine model of femoral artery injury. METHODS: Female swine (n = 7) underwent femoral artery exposure for a total of 10 VL implanted. Study animals underwent hemodilution to a target hematocrit of 15% and ROTEM was used to assess coagulopathy, followed by an arterial injury via transection. The VL was inserted without any sutures. Flow-probe monitors were positioned proximal and distal to the device and flow rates were measured continuously for a total of 90 min. Flow was analyzed and presented as a ratio of distal to proximal flow with the slope of this ratio across time subsequently determined. Angiographic assessment was completed to evaluate for patency and technical complications after 90 min of implant. RESULTS: The average animal weight was 44.1 ± 3.2 kg. The average mean arterial pressure at the time of implant was 51.2 ± 7.8 mmHg, median heart rate was 77.4 (IQR = 77.25-157.4) beats per minute, and average temperature was 36.1 ± 1.5°C. The baseline hematocrit was 13.5 ± 3.0%, average pH was 7.20 ± 0.1, average clotting time was 154.1 ± 58.7 s and average clot formation time was 103.4 ± 10.9 s all demonstrating the acidotic, hypothermic, and coagulopathic state of the swine at the time of insertion. During the 90-min observation period, the average flow gradient identified across the VL was 0.99 ± 0.24, indicating no significant change in flow across the VL. The average slope of the gradients was 0.0005 (P = 0.22), suggesting the ratio of proximal and distal flow did not change over the 90 min. Following 90 min of dwell time, all VL were patent without technical complication. Angiographic assessment at 90 min demonstrated no evidence of dissection, device migration, arterial extravasation, or thromboembolism with any of the 10 devices. CONCLUSIONS: This pilot study demonstrated technical feasibility of the novel VL device over a 90-min observation period. All VL were patent and no negative events or complications were identified. This technology demonstrated significant promise in a coagulopathic state: additional investigation, involving long-term survival, is warranted for further validation.


Subject(s)
Femoral Artery , Female , Animals , Swine , Proof of Concept Study , Pilot Projects , Vascular Patency , Anastomosis, Surgical , Femoral Artery/surgery
20.
Plast Reconstr Surg ; 2023 May 22.
Article in English | MEDLINE | ID: mdl-37220229

ABSTRACT

Plastic surgery offices are subject to a wide variety of cybersecurity threats, including ransomware attacks that encrypt the plastic surgeon's information and make it unusable, as well as data theft and disclosure attacks that threaten to disclose confidential patient information. Cloud-based office systems increase the attack surface and do not mitigate the effects of breaches that can result in theft of credentials. Although employee education is often recommended to avoid the threats, a single error by a single employee has often led to security breaches, and it is not reasonable to expect that no employee will ever make an error. A recognition of the two most common vectors of these breaches, compromised email attachments and surfing to compromised websites, allows the use of technical networking tools to both prevent email attachments from being received and to prevent employee use of unsanctioned and potentially compromised websites. Further, once compromised code is allowed to run within the office network, that code must necessarily make outbound connections to exploit the breach. Preventing that outbound traffic can mitigate the effects of a breach. However, most small office network consultants design firewalls to only limit incoming network traffic and fail to implement technical measures to stop the unauthorized outbound traffic that is necessary for most network attacks. Detailed techniques are provided which can be used to direct IT consultants to properly limit outbound network traffic as well as incoming email attachments, with more information at https://officenetworksecurity.com.

SELECTION OF CITATIONS
SEARCH DETAIL
...