Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 60
Filter
1.
Polymers (Basel) ; 15(18)2023 Sep 17.
Article in English | MEDLINE | ID: mdl-37765645

ABSTRACT

The escalating presence of pathogenic microbes has spurred a heightened interest in antimicrobial polymer composites tailored for hygiene applications. These innovative composites ingeniously incorporate potent antimicrobial agents such as metals, metal oxides, and carbon derivatives. This integration equips them with the unique ability to offer robust and persistent protection against a diverse array of pathogens. By effectively countering the challenges posed by microbial contamination, these pioneering composites hold the potential to create safer environments and contribute to the advancement of public health on a substantial scale. This review discusses the recent progress of antibacterial polymer composite films with the inclusion of metals, metal oxides, and carbon derivatives, highlighting their antimicrobial activity against various pathogenic microorganisms. Furthermore, the review summarizes the recent developments in antibacterial polymer composites for display coatings, sensors, and multifunctional applications. Through a comprehensive examination of various research studies, this review aims to provide valuable insights into the design, performance, and real-time applications of these smart antimicrobial coatings for interactive devices, thus enhancing their overall user experience and safety. It concludes with an outlook on the future perspectives and challenges of antimicrobial polymer composites and their potential applications across diverse fields.

2.
Front Chem ; 11: 1200469, 2023.
Article in English | MEDLINE | ID: mdl-37408562

ABSTRACT

Selective electrochemical hydrogenation (ECH) of biomass-derived unsaturated organic molecules has enormous potential for sustainable chemical production. However, an efficient catalyst is essential to perform an ECH reaction consisting of superior product selectivity and a higher conversion rate. Here, we examined the ECH performance of reduced metal nanostructures, i.e., reduced Ag (rAg) and reduced copper (rCu) prepared via electrochemical or thermal oxidation and electrochemical reduction process, respectively. Surface morphological analysis suggests the formation of nanocoral and entangled nanowire structure formation for rAg and rCu catalysts. rCu exhibits a slight enhancement in ECH reaction performance in comparison to the pristine Cu. However, the rAg exhibits more than two times higher ECH performance without compromising the selectivity for 5-(HydroxyMethyl) Furfural (HMF) to 2,5-bis(HydroxyMethyl)-Furan (BHMF) formation in comparison to the Ag film. Moreover, a similar ECH current density was recorded at a reduced working potential of 220 mV for rAg. This high performance of rAg is attributed to the formation of new catalytically active sites during the Ag oxidation and reduction processes. This study demonstrates that rAg can potentially be used for the ECH process with minimum energy consumption and a higher production rate.

3.
Sensors (Basel) ; 23(11)2023 May 23.
Article in English | MEDLINE | ID: mdl-37299733

ABSTRACT

Glucose monitoring is key to the management of diabetes mellitus to maintain optimal glucose control whilst avoiding hypoglycemia. Non-invasive continuous glucose monitoring techniques have evolved considerably to replace finger prick testing, but still require sensor insertion. Physiological variables, such as heart rate and pulse pressure, change with blood glucose, especially during hypoglycemia, and could be used to predict hypoglycemia. To validate this approach, clinical studies that contemporaneously acquire physiological and continuous glucose variables are required. In this work, we provide insights from a clinical study undertaken to study the relationship between physiological variables obtained from a number of wearables and glucose levels. The clinical study included three screening tests to assess neuropathy and acquired data using wearable devices from 60 participants for four days. We highlight the challenges and provide recommendations to mitigate issues that may impact the validity of data capture to enable a valid interpretation of the outcomes.


Subject(s)
Diabetes Mellitus, Type 1 , Hypoglycemia , Wearable Electronic Devices , Humans , Blood Glucose Self-Monitoring/methods , Blood Glucose , Longitudinal Studies
4.
Diabetes Res Clin Pract ; 200: 110670, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37169307

ABSTRACT

AIM: Cardiac autonomic neuropathy (CAN) has been suggested to be associated with hypoglycemia and impaired hypoglycemia unawareness. We have assessed the relationship between CAN and extensive measures of glucose variability (GV) in patients with type 1 and type 2 diabetes. METHODS: Participants with diabetes underwent continuous glucose monitoring (CGM) to obtain measures of GV and the extent of hyperglycemia and hypoglycemia and cardiovascular autonomic reflex testing. RESULTS: Of the 40 participants (20 T1DM and 20 T2DM) (aged 40.70 ± 13.73 years, diabetes duration 14.43 ± 7.35 years, HbA1c 8.85 ± 1.70%), 23 (57.5%) had CAN. Despite a lower coefficient of variation (CV) (31.26 ± 11.87 vs. 40.33 ± 11.03, P = 0.018), they had a higher CONGA (8.42 ± 2.58 vs. 6.68 ± 1.88, P = 0.024) with a lower median LBGI (1.60 (range: 0.20-3.50) vs. 4.90 (range: 3.20-7.40), P = 0.010) and percentage median time spent in hypoglycemia (4 (range:4-13) vs. 1 (range:0-5), P = 0.008), compared to those without CAN. The percentage GRADEEuglycemia (3.30 ± 2.78 vs. 5.69 ± 3.09, P = 0.017) and GRADEHypoglycemia (0.3 (range: 0 - 3.80) vs. 1.8 (range: 0.9-6.5), P = 0.036) were significantly lower, while the percentage median GRADEHyperglycemia (95.45 (range:93-98) vs. 91.6 (82.8-95.1), P = 0.013) was significantly higher in participants with CAN compared to those without CAN. CONCLUSION: CAN was associated with increased glycemic variability with less time in euglycemia attributed to a greater time in hyperglycemia but not hypoglycemia.


Subject(s)
Diabetes Mellitus, Type 2 , Hyperglycemia , Hypoglycemia , Humans , Diabetes Mellitus, Type 2/complications , Blood Glucose , Blood Glucose Self-Monitoring , Glycated Hemoglobin , Hypoglycemia/complications , Hyperglycemia/complications , Glucose , Hypoglycemic Agents
5.
Photochem Photobiol Sci ; 22(8): 1991-2003, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37184774

ABSTRACT

The present work reports pyridine-based chalones using spectroscopic techniques to use pyridine derivative analysis. The solvatochromic behavior of 3DPP in non-polar, polar protic and aprotic solvents has been investigated experimentally. The photophysical property of the compound in diverse solvents is attributed to the intra-molecular charge transfer interactions. The dipole moment of 3DPP is estimated theoretically and experimentally using various solvatochromic methods. It is observed that there is a bathochromic shift in the emission spectra of 3DPP, which confirms the π → π* transition. Fluorescence quenching of 3DPP is studied. The type of fluorescence quenching mechanism is found to be collisional quenching. A study of FRET theory on 3DPP was carried out with metal ions. There is a considerable energy transfer between 3DPP and metal ions. NLO behaviors of the compound have been revealed with the help of Kurtz-Perry powder technique. Additionally, the title molecule is docked, carried ADMET studies and drug-like activity using in silico tools. It is probed for antifungal activity through bioinformatics kit which showed potential information.

6.
J Fluoresc ; 33(6): 2327-2338, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37036631

ABSTRACT

Simple, portable, and low-cost paper-based sensors are alternative devices that have the potential to replace high-cost sensing technologies. The compatibility of the paper base biosensors for both chemical and biochemical accentuates its feasibility for application in clinical diagnosis, environmental monitoring, and food quality monitoring. High concentration of copper in blood serum and urine is associated with diseases like liver diseases, carcinomas, acute and chronic infections, rheumatoid arthritis, etc. Detection of copper concentration can give an early sign of Alzheimer disease. Apart from that genetic Wilson's disease can be detected by evaluating the concentration of copper in the urine. In view of the above advantages, a novel and the highly sensitive paper-based sensor has been designed for the selective detection of Cu2+ ions. The fast and highly sensitive chemiresistive multi-dye system sensor can detect Cu2+ ions selectively in as low as 2.23 ppm concentration. Least interference has been observed for counter ion in the detection of Cu2+. Copper chloride, nitrate, and acetate were used to validate the detection process. This assay provides a very high selectivity of Cu2+ ion over other metal cations such as Na+, Mg2+, Ca2+, etc. The easy preparation and high stability of dye solutions, easy functionalization of the paper-based sensors, high selectivity over other cations, low interference of counter anion, and significantly low detection limit of 2.23 ppm make it an effective Cu2+ ion sensor for real-time application in near future.


Subject(s)
Copper , Metals , Cations
7.
3 Biotech ; 13(3): 109, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36875961

ABSTRACT

For many biomedical applications, high-precision CO2 detection with a rapid response is essential. Due to the superior surface-active characteristics, 2D materials are particularly crucial for electrochemical sensors. The liquid phase exfoliation method of 2D Co2Te3 production is used to achieve the electrochemical sensing of CO2. The Co2Te3 electrode performs better than other CO2 detectors in terms of linearity, low detection limit, and high sensitivity. The outstanding physical characteristics of the electrocatalyst, including its large specific surface area, quick electron transport, and presence of a surface charge, can be credited for its extraordinary electrocatalytic activity. More importantly, the suggested electrochemical sensor has great repeatability, strong stability, and outstanding selectivity. Additionally, the electrochemical sensor based on Co2Te3 could be used to monitor respiratory alkalosis. Supplementary Information: The online version contains supplementary material available at 10.1007/s13205-023-03497-z.

8.
Sci Rep ; 13(1): 694, 2023 Jan 13.
Article in English | MEDLINE | ID: mdl-36639436

ABSTRACT

Theoretically, it is more challenging to anticipate the conversion and selectivity of a photochemical experiment compared to thermally generated reactivity. This is due to the interaction of light with a photoreactive substrate. Photochemical reactions do not yet receive the same level of broad analytical study. Here, we close this research gap by presenting a methodology for statistically forecasting the time-dependent progression of photoreactions using widely available LEDs. This study uses NiS/ZnO in perovskite (MAPbI3) solar cells as an additive (5 volume %). The effect of monolithic perovskite solar cells (mPSCs) on forecasting the wavelength of LEDs has been carefully investigated using various characterization methods, including X-ray diffraction (XRD) and Transmission electron microscopy (TEM). The photocatalytic activity was analyzed by measuring the voltage produced. Various factors like selectivity, stability and sensitivity were also examined. This work provides a new perspective to validate NiS/ZnO photocatalysts for predicting the wavelength of different light sources and to apply in photolithography.

9.
3 Biotech ; 13(2): 63, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36718410

ABSTRACT

Nanobiotechnology has been an encouraging approach to improving the efficacy of hydrophobic bioactive compounds. The biologically active constituents present in herbal extracts are poorly absorbed, resulting in loss of bioavailability and efficacy. Hence, herbal medicine and nanotechnology are combined to overcome these limitations. The surface-to-volume ratio of nanoparticles is high and as the size is small, the functional properties are enhanced. The present study reports the synthesis of cinnamon and cumin (Ci-Cu) dual drug-loaded poly (D, L-lactide-co-glycolide) (PLGA) nanoparticles (NPs) to overcome the limitations of oral bioavailability and extend the effect of these drugs for alleviating health problems. The solvent evaporation method was adopted for the synthesis, and the as-prepared nanoparticles were characterized by Scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, Transmission electron microscopy (TEM) and X-ray diffraction (XRD). The average size of the formed spherical Ci-Cu nanoparticles ranged between 90 and 120 nm. The encapsulation efficiency of the drug was found to be 79% ± 4.5%. XRD analysis demonstrated that cinnamon and cumin were amorphously scattered in the PLGA matrix. The FTIR bands showed no evident changes suggesting the no direct molecular interactions between the drug and the polymer. At pH 6.9, the release studies in vitro exhibited a burst initially followed by a tendency to obtain a slower steady release. The results indicated that the Cu-Ci dual drug-loaded polymeric NPs has drug release at a slower rate. The time taken for 25% release of drug in Ci-Cu-loaded PLGA NPs was twice as compared to cumin-loaded PLGA Nps, and three times compared to cinnamon-loaded PLGA NPs.

10.
Biosensors (Basel) ; 12(12)2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36551073

ABSTRACT

Over the last decades, molecularly imprinted polymers (MIPs) have emerged as selective synthetic receptors that have a selective binding site for specific analytes/target molecules. MIPs are synthetic analogues to the natural biological antigen-antibody system. Owing to the advantages they exhibit, such as high stability, simple synthetic procedure, and cost-effectiveness, MIPs have been widely used as receptors/sensors for the detection and monitoring of a variety of analytes. Moreover, integrating electrochemical sensors with MIPs offers a promising approach and demonstrates greater potential over traditional MIPs. In this review, we have compiled the methods and techniques for the production of MIP-based electrochemical sensors along with the applications of reported MIP sensors for a variety of analytes. A comprehensive in-depth analysis of recent trends reported on picomolar (pM/10-12 M)) and beyond picomolar concentration LOD (≥pM) achieved using MIPs sensors is reported. Finally, we discuss the challenges faced and put forward future perspectives along with our conclusion.


Subject(s)
Molecular Imprinting , Molecularly Imprinted Polymers , Polymers/chemistry , Limit of Detection , Molecular Imprinting/methods
11.
3 Biotech ; 12(12): 334, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36330379

ABSTRACT

The concentration of carbon dioxide (CO2) in unhealthy people differs greatly from healthy people. High-precision CO2 detection with a quick response time is essential for many biomedical applications. A major focus of this research is on the detection of CO2, one of the most important health biomarkers. We investigated a low-cost, flexible, and reliable strategy by using dyes for colorimetric CO2 sensing in this study. The impacts of temperature, pH, reaction time, reusability, concentration, and dye selectivity were studied thoroughly. This study described real-time CO2 analysis. Using this multi-dye method, we got an average detection limit of 1.98 ppm for CO2, in the range of 50-120 ppm. A portable colorimetric instrument with a smartphone-assisted unit was constructed to determine the relative red/green/blue values for real-time and practical applications within 15 s of interaction and the readings are very similar to those of an optical fiber probe. Environmental and biological chemistry applications are likely to benefit greatly from this unique approach.

12.
Endocr Connect ; 11(12)2022 Dec 01.
Article in English | MEDLINE | ID: mdl-36240043

ABSTRACT

Objective: Continuous glucose monitoring (CGM) has revealed that glycemic variability and low time in range are associated with albuminuria and retinopathy. We have investigated the relationship between glucose metrics derived from CGM and a highly sensitive measure of neuropathy using corneal confocal microscopy in participants with type 1 and type 2 diabetes. Methods: A total of 40 participants with diabetes and 28 healthy controls underwent quantification of corneal nerve fiber density (CNFD), corneal nerve branch density (CNBD), corneal nerve fiber length (CNFL) and inferior whorl length (IWL) and those with diabetes underwent CGM for four consecutive days. Results: CNBD was significantly lower in patients with high glycemic variability (GV) compared to low GV (median (range) (25.0 (19.0-37.5) vs 38.6 (29.2-46.9); P = 0.007); in patients who spent >4% compared to <4% time in level 1 hypoglycemia (54-69 mg/dL) (25.0 (22.9-37.5) vs 37.5 (29.2-46.9); P = 0.045) and in patients who spent >1% compared to <1% time in level 2 hypoglycemia (<54 mg/dL) (25.0 (19.8-41.7) vs 35.4 (28.1-44.8); P = 0.04). Duration in level 1 hypoglycemia correlated with CNBD (r = -0.342, P = 0.031). Duration in level 1 (181-250 mg/dL) and level 2 (>250 mg/dL) hyperglycemia did not correlate with CNFD (P > 0.05), CNBD (P > 0.05), CNFL (P > 0.05) or IWL (P > 0.05). Conclusions: Greater GV and duration in hypoglycemia, rather than hyperglycemia, are associated with nerve fiber loss in diabetes.

13.
RSC Adv ; 12(37): 23946-23955, 2022 Aug 22.
Article in English | MEDLINE | ID: mdl-36128540

ABSTRACT

Exhaled breath (EB) contains several macromolecules that can be exploited as biomarkers to provide clinical information about various diseases. Hydrogen peroxide (H2O2) is a biomarker because it indicates bronchiectasis in humans. This paper presents a non-invasive, low-cost, and portable quantitative analysis for monitoring and quantifying H2O2 in EB. The sensing unit works on colorimetry by the synergetic effect of eosin blue, potassium permanganate, and starch-iodine (EPS) systems. Various sampling conditions like pH, response time, concentration, temperature and selectivity were examined. The UV-vis absorption study of the assay showed that the dye system could detect as low as ∼0.011 ppm levels of H2O2. A smart device-assisted detection unit that rapidly detects red, green and blue (RGB) values has been interfaced for practical and real-time application. The RGB value-based quantification of the H2O2 level was calibrated against NMR spectroscopy and exhibited a close correlation. Further, we adopted a machine learning approach to predict H2O2 concentration. For the evaluation, an artificial neural network (ANN) regression model returned 0.941 R 2 suggesting its great prospect for discrete level quantification of H2O2. The outcomes exemplified that the sensor could be used to detect bronchiectasis from exhaled breath.

14.
ACS Sens ; 7(8): 2132-2163, 2022 08 26.
Article in English | MEDLINE | ID: mdl-35972775

ABSTRACT

Gas sensors, capable of detecting and monitoring trace amounts of gas molecules or volatile organic compounds (VOCs), are in great demand for numerous applications including diagnosing diseases through breath analysis, environmental and personal safety, food and agriculture, and other fields. The continuous emergence of new materials is one of the driving forces for the development of gas sensors. Recently, 2D materials have been gaining huge attention for gas sensing applications, owing to their superior electrical, optical, and mechanical characteristics. Especially for 2D MXenes, high specific area and their rich surface functionalities with tunable electronic structure make them compelling for sensing applications. This Review discusses the latest advancements in the 2D MXenes for gas sensing applications. It starts by briefly explaining the family of MXenes, their synthesis methods, and delamination procedures. Subsequently, it outlines the properties of MXenes. Then it describes the theoretical and experimental aspects of the MXenes-based gas sensors. Discussion is also extended to the relation between sensing performance and the structure, electronic properties, and surface chemistry. Moreover, it highlights the promising potential of these materials in the current gas sensing applications and finally it concludes with the limitations, challenges, and future prospects of 2D MXenes in gas sensing applications.

15.
Polymers (Basel) ; 14(13)2022 Jun 28.
Article in English | MEDLINE | ID: mdl-35808667

ABSTRACT

During the last few years, there has been an increase in public awareness of antimicrobial fabrics, as well as an increase in commercial opportunities for their use in pharmaceutical and medical settings. The present study reports on the optimized fabrication of protonated polyaniline (PANI)-integrated polyester (PES) fabric. Para-toluene sulfonic acid (pTSA) was used to protonate the PANI fabric and thus grant it antibacterial performance. The results of a 1,1-diphenyl-2-picrylhydrazyl (DPPH) scavenging assay showed high antioxidant activity of protonated PANI fabric at a scavenging efficiency of 84.83%. Moreover, the findings revealed remarkably sensitive antibacterial performance of PANI-integrated fabric against the following Gram-positive bacteria: methicillin-resistant Staphylococcus aureus (MRSA), S. epidermidis, and S. aureus; and also against the following Gram-negative bacteria: P. aeruginosa, E. coli, and S. typhi. Attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy and energy dispersive X-ray fluorescence (EDXRF) were used to determine the changes in the structural and elemental compositions of PANI fabric upon treatment with bacterial strains. Electrochemical impedance spectroscopy (EIS) revealed that the electrical conductivity value of protonated PANI fabric decreased by one (1) order of magnitude against P. aeruginosa and S. aureus, from 3.35 ± 7.81 × 10-3 S cm-1 to 6.11 ± 7.81 × 10-4 S cm-1 and 4.63 ± 7.81 × 10-4 S cm-1, respectively. Scanning electron microscopy (SEM) analysis showed the disruption of bacterial membranes and their structures when exposed to protonated PANI fabric; meanwhile, thermogravimetric analysis (TGA) demonstrated that the fabric retained its thermal stability characteristics. These findings open up potential for the use of antimicrobial fabrics in the pharmaceutical and medical sectors.

16.
3 Biotech ; 12(8): 171, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35845116

ABSTRACT

Wearable sensors have drawn considerable interest in the recent research world. However, simultaneously realizing high sensitivity and wide detection limits under changing surrounding environment conditions remains challenging. In the present study, we report a wearable piezoresistive pressure sensor capsule that can detect pulse rate and human motion. The capsule includes a flexible silicon cover and is filled with different PVA/MXene (PVA-Mx) composites by varying the weight percentage of MXene in the polymer matrix. Different characterizations such as XRD, FTIR and TEM results confirm that the PVA-Mx silicon capsule was successfully fabricated. The PVA-Mx gel-based sensor capsule remarkably endows a low detection limit of 2 kPa, exhibited high sensitivity of 0.45 kPa-1 in the ranges of 2-10 kPa, and displayed a response time of ~ 500 ms, as well as good mechanical stability and non-attenuating durability over 500 cycles. The piezoresistive sensor capsule sensor apprehended great stability towards changes in humidity and temperature. These findings substantiate that the PVA/MXene sensor capsule is potentially suitable for wearable electronics and smart clothing.

17.
Langmuir ; 38(31): 9526-9531, 2022 Aug 09.
Article in English | MEDLINE | ID: mdl-35900104

ABSTRACT

Developing an efficient catalytic system for electrolysis with reduced platinum (Pt) loading while maintaining performance comparable to bulk platinum metal is important to decrease costs and improve scalability of the hydrogen fuel economy. Here we report the performance of a novel sputter-deposited molybdenum (Mo) thin film with an extremely low co-loading of Pt, where Pt atoms were dispersed on Mo (Ptd-Mo) as an electrocatalyst for the hydrogen evolution reaction (HER) in either alkaline or acidic media. The Ptd-Mo electrocatalyst presents similar catalytic activity to bulk Pt in alkaline media, while the performance is only slightly decreased in acidic media. Differential electrochemical mass spectrometry (DEMS) results confirm that the Ptd-Mo electrocatalyst produced hydrogen at a rate comparable with that of a pristine Pt sample at the same potential. A comparison with Pt-loaded degenerately doped p-type doped silicon (Ptd-Si) suggests that Mo and Pt work synergistically to boost the performance of Ptd-Mo catalysts. Cyclic voltammetry (CV) and X-ray photoelectron spectroscopy (XPS) before and after 1000 cycles of continuous operation confirm the significant durability of the Ptd-Mo performance. Overall, the Ptd-Mo electrocatalyst, with comparable HER activity to bulk Pt despite an ultra-low Pt loading, could be a strong candidate for hydrogen production in either acidic or basic conditions.

18.
Front Bioeng Biotechnol ; 10: 876672, 2022.
Article in English | MEDLINE | ID: mdl-35646863

ABSTRACT

Diabetes mellitus is characterized by elevated blood glucose levels, however patients with diabetes may also develop hypoglycemia due to treatment. There is an increasing demand for non-invasive blood glucose monitoring and trends detection amongst people with diabetes and healthy individuals, especially athletes. Wearable devices and non-invasive sensors for blood glucose monitoring have witnessed considerable advances. This review is an update on recent contributions utilizing novel sensing technologies over the past five years which include electrocardiogram, electromagnetic, bioimpedance, photoplethysmography, and acceleration measures as well as bodily fluid glucose sensors to monitor glucose and trend detection. We also review methods that use machine learning algorithms to predict blood glucose trends, especially for high risk events such as hypoglycemia. Convolutional and recurrent neural networks, support vector machines, and decision trees are examples of such machine learning algorithms. Finally, we address the key limitations and challenges of these studies and provide recommendations for future work.

19.
20.
ACS Omega ; 7(5): 4257-4266, 2022 Feb 08.
Article in English | MEDLINE | ID: mdl-35155918

ABSTRACT

Human breath analysis of volatile organic compounds has gained significant attention recently because of its rapid and noninvasive potential to detect various metabolic diseases. The detection of ketones in the breath and blood is key to diagnosing and managing diabetic ketoacidosis (DKA) in patients with type 1 diabetes. It may also be of increasing importance to detect euglycemic ketoacidosis in patients with type 1 or type 2 diabetes or heart failure, treated with sodium-glucose transporter-2 inhibitors (SGLT2-i). The present research evaluates the efficiency of colorimetry for detecting acetone and ethanol in exhaled human breath with the response time, pH effect, temperature effect, concentration effect, and selectivity of dyes. Using the proposed multidye system, we obtained a detection limit of 0.0217 ppm for acetone and 0.029 ppm for ethanol in the detection range of 0.05-50 ppm. A smartphone-assisted unit consisting of a portable colorimetric device was used to detect relative red/green/blue values within 60 s of the interface for practical and real-time application. The developed method could be used for rapid, low-cost detection of ketones in patients with type 1 diabetes and DKA and patients with type 1 or type 2 diabetes or heart failure treated with SGLT2-I and euglycemic ketoacidosis.

SELECTION OF CITATIONS
SEARCH DETAIL
...