Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Kidney Int ; 74(11): 1410-9, 2008 12.
Article in English | MEDLINE | ID: mdl-18818686

ABSTRACT

Venous stenosis is a significant problem in arteriovenous fistulae, likely due to anatomical configuration and wall shear stress profiles. To identify linkages between wall shear stress and the magnitude and pattern of vascular stenosis, we produced curved and straight fistulae in a pig model. A complete wall stress profile was calculated for the curved configuration and correlated with luminal stenosis. Computer modeling techniques were then used to derive a wall shear stress profile for the straight arteriovenous fistula. Differences in the wall shear stress profile of the curved and straight fistula were then related to histological findings. There was a marked inverse correlation between the magnitude of wall shear stress within different regions of the curved arteriovenous fistula and luminal stenosis in these same regions. There were also significantly greater differences in wall shear stress between the outer and inner walls of the straight as compared to curved arteriovenous fistula, which translated into a more eccentric histological pattern of intima-media thickening. Our results suggest a clear linkage between anatomical configuration, wall shear stress profiles, and the pattern of luminal stenosis and intima-media thickening in a pig model of arteriovenous fistula stenosis. These results suggest that fistula failure could be reduced by using computer modeling prior to surgical placement to alter the anatomical and, consequently, the wall shear stress profiles in an arteriovenous fistula.


Subject(s)
Arteriovenous Fistula/etiology , Constriction, Pathologic/etiology , Hemodynamics/physiology , Animals , Computer Simulation , Disease Models, Animal , Stress, Mechanical , Swine
2.
Biomed Eng Online ; 7: 24, 2008 Aug 27.
Article in English | MEDLINE | ID: mdl-18752683

ABSTRACT

BACKGROUND: The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true severity of epicardial stenosis, we evaluate a diagnostic parameter, which is obtained from fundamental fluid dynamics principles. This experimental and numerical study focuses on the characterization of the diagnostic parameter, pressure drop coefficient, and also evaluates the pressure recovery downstream of stenoses. METHODS: Three models of coronary stenosis namely, moderate, intermediate and severe stenosis, were manufactured and tested in the in-vitro set-up simulating the epicardial coronary network. The trans-stenotic pressure drop and flow distal to stenosis models were measured by non-invasive method, using external pressure and flow sensors, and by invasive method, following guidewire insertion across the stenosis. The viscous and momentum-change components of the pressure drop for various flow rates were evaluated from quadratic relation between pressure drop and flow. Finally, the pressure drop coefficient (CDPe) was calculated as the ratio of pressure drop and distal dynamic pressure. The pressure recovery factor (eta) was calculated as the ratio of pressure recovery coefficient and the area blockage. RESULTS: The mean pressure drop-flow characteristics before and during guidewire insertion indicated that increasing stenosis causes a shift in dominance from viscous pressure to momentum forces. However, for intermediate (approximately 80%) area stenosis, which is between moderate (approximately 65%) and severe (approximately 90%) area stenoses, both losses were similar in magnitude. Therefore, guidewire insertion plays a critical role in evaluating the hemodynamic severity of coronary stenosis. More importantly, mean CDPe increased (17 +/- 3.3 to 287 +/- 52, n = 3, p < 0.01) and mean eta decreased (0.54 +/- 0.04 to 0.37 +/- 0.05, p < 0.01) from moderate to severe stenosis during guidewire insertion. CONCLUSION: The wide range of CDPe is not affected that much by the presence of guidewire. CDPe can be used in clinical practice to evaluate the true severity of coronary stenosis due to its significant difference between values measured at moderate and severe stenoses.


Subject(s)
Blood Flow Velocity , Blood Pressure , Coronary Stenosis/diagnosis , Coronary Stenosis/physiopathology , Diagnosis, Computer-Assisted/methods , Models, Cardiovascular , Pericardium/physiopathology , Computer Simulation , Hemorheology/methods , Humans , Vascular Resistance
3.
J Invasive Cardiol ; 20(6): E183-6, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18523333

ABSTRACT

One of the commonly used parameters for evaluating aortic regurgitation is the rate of pressure decay data obtained from echocardiographic evaluation or cardiac catheterization. The measurement of the rate of equalization of pressure between the aorta and the left ventricle and its utility in the setting of aortic insufficiency has been validated. Intuitively, the Doppler equivalent, pressure half-time, is inversely related to the severity of regurgitation. However, this is a phenomenon dependent on multiple variables including blood pressure, heart rate, compliance of the receiving chamber, effects of vasopressors and the volume status of the patient. We report a case of unique hemodynamics obtained during cardiac catheterization due to low filling pressures that was further confounded by elevated systemic vascular resistance in a critically ill patient with angiographically severe aortic regurgitation.


Subject(s)
Aortic Valve Insufficiency/therapy , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Cardiac Catheterization , Coronary Angiography , Hemodynamics , Aortic Valve Insufficiency/complications , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/physiopathology , Atrial Flutter/etiology , Diastole , Female , Heart Failure/etiology , Humans , Middle Aged , Severity of Illness Index , Stroke Volume
5.
J Surg Res ; 150(1): 24-33, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18262546

ABSTRACT

BACKGROUND: Functional/physiological evaluation of coronary artery stenoses may be more important than anatomical measurements of severity. Optimization of thresholds for stenosis intervention and treatment endpoints depend on coupling functional hemodynamic and anatomical data. We sought to develop a single prognostic parameter correlating stenosis-specific anatomy, pressure gradient, and velocities that could be measured during catheterization. MATERIALS AND METHODS: In vivo Experiments were performed in six swine (41 +/- 3 kg). The lumen area of the left anterior descending coronary artery was measured with intravascular ultrasound. An angioplasty balloon was inflated to create the desired intraluminal area obstructions. Fractional flow reserve (FFR), coronary flow reserve (CFR), and hyperemic-stenosis-resistance index were measured distal to the balloon at peak hyperemia with 10 mg intracoronary papaverine. A functional index:pressure drop coefficient (CDP) and a combined functional and anatomical index:lesion flow coefficient (LFC) were calculated from measured hyperemic pressure gradient, velocity, and percentage area stenosis. P < 0.05 was considered statistically significant. RESULTS: The CDP and LFC correlated linearly and significantly with FFR and CFR. The CDP (R(2) = 0.72, P < 0.0001) correlated better than LFC (R(2) = 0.19, P < 0.003) with hyperemic-stenosis-resistance index. When LFC was correlated simultaneously with FFR and CFR, R(2) improved to 0.82 (P < 0.0001). Inclusion of percentage area stenoses concurrently with FFR and CFR marginally improved the correlation with LFC. CONCLUSIONS: A dimensionless parameter combining measured pressure gradient, velocity, and area reduction data can optimally define the severity of coronary stenoses based on our preliminary results and could prove useful clinically.


Subject(s)
Blood Pressure , Coronary Circulation , Coronary Stenosis/diagnosis , Animals , Cardiac Catheterization , Coronary Stenosis/pathology , Coronary Stenosis/physiopathology , Coronary Vessels/pathology , Swine
6.
J Biomech ; 40(3): 652-62, 2007.
Article in English | MEDLINE | ID: mdl-16530204

ABSTRACT

Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance microvascular disease. In this study, a more comprehensive diagnostic parameter, named as lesion flow coefficient, c, is proposed. The coefficient, c, which accounts for mean pressure drop, Delta p, mean coronary flow, Q, and percentage area stenosis, can be used to assess the hemodynamic severity of a coronary artery stenoses. Importantly, the contribution of viscous loss and loss due to momentum change for several lesion sizes can be distinguished using c. FFR(myo), CFR and c were calculated for pre-angioplasty, intermediate and post-angioplasty epicardial lesions, without microvascular disease. While hyperemic c decreased from 0.65 for pre-angioplasty to 0.48 for post-angioplasty lesion with guidewire of size 0.35 mm, FFR(myo) increased from 0.52 to 0.87, and CFR increased from 1.72 to 3.45, respectively. Thus, reduced loss produced by momentum change due to lower percentage area stenosis decreased c. For post-angioplasty lesion, c decreased from 0.55 to 0.48 with the insertion of guidewire. Hence, increased viscous loss due to the presence of guidewire decreased c compared with a lesion without guidewire. Further, c showed a linear relationship with FFR(myo), CFR and percentage area stenosis for pre-angioplasty, intermediate and post-angioplasty lesion. These baseline values of c were developed from fluid dynamics fundamentals for focal lesions, and provided a single hemodynamic endpoint to evaluate coronary stenosis severity.


Subject(s)
Coronary Artery Disease/physiopathology , Hemorheology , Models, Biological , Biomechanical Phenomena , Humans
7.
J Oral Pathol Med ; 23(3): 114-8, 1994 Mar.
Article in English | MEDLINE | ID: mdl-7517451

ABSTRACT

Factor XIIIa+ "dendrocytes", normal residents of the submucosa and dermis, are a morphologically and phenotypically distinctive subset of the monocyte-macrophage system. Because these cells are believed to participate in the regulation of immune responses, we postulated that they may play a role in the pathogenesis of lichen planus, a condition of immune dysregulation. Tissue sections of oral lichen planus were evaluated immunohistochemically for evidence of differences in dendrocyte populations in lesional and non-lesional areas from the same patient. In addition to factor XIIIa, sections were stained for antigens (CD68, S-100 protein, CD36) that may be expressed by other cells that occasionally exhibit dendritic profiles. CD18 (found on leukocytes and dendrocytes) and its ligand ICAM-1 (intercellular adhesion molecule) were also identified in sections to determine if these antigens are operative in lichen planus. Results showed that XIIIa+ dendrocytes were significantly increased in number (and size) in lichen planus. The mean number of dendrocytes in connective tissue subjacent to basement membrane (0.064 mm2) was 27 in lichen planus as compared to 10 in adjacent unaffected tissue. Similar increases were also evident in connective tissue deep to this zone (mean of 20 dendrocytes vs. mean of 8). CD68+ macrophages were also abundant in the lichen planus infiltrate, and S-100+ connective tissue cells were frequently seen. CD36+ dendritic cells were seen in relatively small numbers in the same sites where dendrocytes were found. ICAM-1+ connective tissue dendritic cells of undetermined lineage were also evident in the diseased areas.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Dendritic Cells/pathology , Lichen Planus/pathology , Mouth Diseases/pathology , Transglutaminases/analysis , Adult , Aged , Antigens, CD/analysis , Antigens, Differentiation, Myelomonocytic/analysis , CD18 Antigens , CD36 Antigens , Cell Adhesion Molecules/analysis , Cell Count , Connective Tissue/pathology , Dendritic Cells/metabolism , Endothelium, Vascular/pathology , Humans , Intercellular Adhesion Molecule-1 , Lichen Planus/metabolism , Lymphocytes/pathology , Macrophages/pathology , Middle Aged , Mouth Diseases/metabolism , Receptors, Cytoadhesin/analysis , S100 Proteins/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...