Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Ophthalmol Case Rep ; 30: 101845, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37128498

ABSTRACT

Purpose: To report two patients with a complication of Yamane intrascleral haptic fixation surgery (ISHF) with the Zeiss CT Lucia 602 lens: severely tilted intraocular lens (IOL) leading to significantly decreased vision in the early post-operative period. Observations: We report two patients presenting with severely tilted IOL implants one day and one month following Yamane ISHF. The first patient is a monocular 81-year-old woman referred for treatment of cornea edema. Initial surgery involved replacement of an anterior chamber lens with a CT Lucia 602 posterior chamber lens using Yamane technique and Descemet's stripping endothelial keratoplasty. The patient returned at one month follow-up with poor vision and IOL tilt observable at the slit lamp through a peripheral iridectomy site. Explanation of the Zeiss lens revealed haptic distortion at the optic-haptic insertion point such that each haptic was about 45° off axis to the plane of the optic in approximately equal and opposite directions. The second patient, a 75-year-old woman, was referred with a completely dislocated lens-bag complex in the right eye. The initial operative treatment for this patient included pars plana vitrectomy, retrieval and removal of the dislocated lens-bag complex, and placement of a Zeiss 602 lens via Yamane ISHF technique. On the first postoperative day, the patient was count fingers in the right eye with an intraocular pressure of 5 mm Hg and obvious IOL tilt on slit lamp examination. Explanation of the lens revealed severely distorted haptics relative to the optic by more than a 60-degree angle on both sides. In both cases, initial surgery was performed with an IOL inspected prior to implantation and found to have normal appearing haptics. At the end of each case, there was adequate centration and no tilt of the IOL. Management in both patients included removal of the defective lens and placement of a new, same power CT Lucia 602 lens via the Yamane technique. Visual acuity improved from CF to 20/30 best corrected after reoperation in both cases. Conclusions and importance: In summary, we describe a complication of Yamane ISHF with the CT Lucia 602 lens in which there is lens tilting associated with distortion at the optic-haptic fastening zone in the early postoperative period. In the event of a titled lens following Yamane ISHF, awareness of this complication may help surgeons consider lens replacement, as the haptics may be permanently distorted or damaged.

2.
Am J Ophthalmol Case Rep ; 28: 101738, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36393913

ABSTRACT

Purpose: To report three patients with an uncommon delayed complication of cataract extraction: corneal edema following dispersion of calcific lens particles from a degenerating Soemmering ring cataract. Observations: We report three patients, 75-92 years old, presenting with corneal edema and dispersed, degenerated calcific lens material in the anterior chamber and vitreous 20-30 years after cataract surgery. In all patients, calcific particles studded the posterior surface of the cornea in a gravity-dependent distribution without apparent inflammation and were associated with localized corneal edema. In one patient, calcific particles were also associated with secondary open angle glaucoma. Deposits originated from the calcified Soemmering ring cataract. Histopathological examination demonstrated extracellular calcific deposits compatible with cataractous lens material on the posterior surface of stripped Descemet membrane of two patients. The deposits were associated with prominent localized loss of corneal endothelium and were not associated with inflammation. Morphologically similar acellular material was identified in the biopsied aqueous and vitreous fluid of one patient. Management included endothelial keratoplasty, anterior chamber lavage, pars plana vitrectomy, aspiration/removal of a portion of Soemmering ring cataract without intraocular lens implant explantation, and the removal of the entire capsular bag/implant complex. Cornea cleared and visual acuity improved in both patients who underwent endothelial keratoplasty. Persistent elevated intraocular pressure led to visual deterioration in one patient with secondary glaucoma. Conclusions and Importance: Dispersion of calcific Soemmering ring cataract can occur decades following cataract surgery leading to corneal edema, secondary glaucoma, and vitreous opacities. Timely recognition of this phenomenon may prevent ocular morbidity, including corneal edema and glaucoma.

SELECTION OF CITATIONS
SEARCH DETAIL
...