Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
J Am Coll Cardiol ; 83(22): 2179-2192, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38811095

ABSTRACT

BACKGROUND: Transcatheter correction of sinus venosus defects (SVDs) using balloon-mounted covered stents provides an attractive surgical alternative. Surgery may be complicated by superior vena caval or right upper pulmonary vein (RUPV) stenosis, sinus nodal dysfunction, and residual additional pulmonary veins. OBJECTIVES: Being a new intervention, technical modifications would simplify the procedure, improve universal applicability, and reduce or tackle complications. METHODS: Patients were included if balloon interrogation of cavoatrial junction confirmed closure of SVD and redirected RUPV to the left atrium. A single-center experience was analyzed to summarize the procedural modifications over 8 years. Transesophageal echocardiogram (TEE) on follow-up was done to identify residual shunt, RUPV flows, and stent thrombosis. RESULTS: A total of 100 patients including 9 children with a median age of 35 years (range, 4-69 years) underwent SVD closure after balloon interrogation. Among 57 patients balloon interrogated in the first 5 years, 70% underwent transcatheter closure, with 2 failures. RUPV occlusion caused the exclusions. Inclusions improved to 94% among the subsequent 65 balloon interrogations when RUPV protection was implemented, with 1 failure. Stent embolization caused the 3 failures warranting surgery. Recent modifications included limited transesophageal echocardiogram without anesthesia, avoiding venovenous circuit, interrogation with semicompliant balloons, trans-septal RUPV protection, overlapping stents to permit additional vein drainage to superior vena cava and tackle embolizations. There were no deaths. Minor complications included stent embolizations stabilized in catheterization laboratory in 2 patients, left innominate vein jailing in 2 patients, insignificant residual flows, and nonocclusive asymptomatic stent thrombosis in 4 patients. CONCLUSIONS: Procedural success was 97%. Recent modifications increased patient inclusions, decreased complications, and simplified the intervention.


Subject(s)
Cardiac Catheterization , Stents , Humans , Child , Adolescent , Child, Preschool , Male , Female , Middle Aged , Adult , Aged , Young Adult , Cardiac Catheterization/methods , Echocardiography, Transesophageal/methods , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Retrospective Studies , Treatment Outcome , Follow-Up Studies
3.
Cardiol Young ; 34(3): 684-686, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38329102

ABSTRACT

While infradiaphragmatic total anomalous pulmonary venous drainage to portal vein is well described, hemianomalous drainage of right pulmonary veins to portal vein in Scimitar syndrome has not yet been reported.


Subject(s)
Pulmonary Veins , Scimitar Syndrome , Humans , Diaphragm/diagnostic imaging , Portal Vein/diagnostic imaging , Portal Vein/surgery , Scimitar Syndrome/diagnostic imaging , Scimitar Syndrome/surgery , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Drainage
4.
Catheter Cardiovasc Interv ; 103(2): 317-321, 2024 02.
Article in English | MEDLINE | ID: mdl-38123891

ABSTRACT

Transcatheter sinus venosus defect closure uses a long covered stent of appropriate length and diameter across the cavoatrial junction after balloon interrogation. The fabric in the covered stent creates a roof for the right upper pulmonary vein that closes the interatrial communication and redirects the vein into the left atrium behind the stent. A fabric tear in the covered stent may cause endoleak that will result in residual flows across the struts of the covered stent, causing procedural failure. This report highlights the identification of fabric leak by angiography and transesophageal echocardiography and steps to overcome this complication by the placement of another overlapping covered stent.


Subject(s)
Endoleak , Heart Septal Defects, Atrial , Humans , Endoleak/diagnostic imaging , Endoleak/etiology , Endoleak/therapy , Treatment Outcome , Stents
5.
Ann Pediatr Cardiol ; 16(3): 215-218, 2023.
Article in English | MEDLINE | ID: mdl-37876953

ABSTRACT

Transcatheter correction of superior sinus venosus defects using covered stent is increasingly reported in the literature and provides an alternative option to surgery in appropriately selected adults. Being a new intervention, meticulous attention to procedural techniques and precise surveillance imaging modalities are vital to detect and avoid potential early and late complications. This report highlights the occurrence of a residual interatrial communication following covered stent placement and large subclinical asymptomatic nonocclusive thrombus formation at the right atrial end of the stent. The management of both these complications is also highlighted in this report.

6.
Ann Pediatr Cardiol ; 16(3): 219-222, 2023.
Article in English | MEDLINE | ID: mdl-37876950

ABSTRACT

Anomalous left coronary artery origin from pulmonary artery causes heart failure in infancy from ischemia and secondary mitral regurgitation. Rich intramyocardial collateralization may permit survival to adult age, where coronaries become tortuous and aneurysmally dilated. Surgery in adults involves left coronary ligation and providing a bypass graft to the left system, unlike coronary translocation adopted in infants. Unfavorable coronary remodeling in operated adults may lead to late coronary thrombotic occlusions. Two adults with markedly dilated tortuous coronary arteries showed variable remodeling after corrective intervention that impacted outcomes on follow-up. We stress the need for lifelong angiographic surveillance in older patients.

7.
Pediatr Cardiol ; 44(7): 1591-1598, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37505266

ABSTRACT

Device closure has become the preferred procedure for treating oval fossa defects in the last two decades. More recently, transcatheter sinus venosus defect (SVD) closure has emerged as an alternative to surgery. Transcatheter stenting aims to overcome potential late surgical complications such as stenosis of the superior vena cava (SVC) and right upper pulmonary vein (RUPV), as well as sinus node dysfunction. Balloon interrogation of the cavoatrial junction is able to identify patients who are suitable candidates for nonsurgical closure. Successful closure is possible when the balloon seals the SVD and redirects the RUPV towards the left atrium. Oval fossa (secundum) defects can coexist in approximately 9-16% of patients with SVD. Among a group of 80 patients who underwent transcatheter closure of SVD, five adult patients aged between 22 and 52 years also required device closure of an associated oval fossa defect. The procedure involved simultaneous balloon interrogation of both the SVD and oval fossa defect, with continuous monitoring of the RUPV using bilateral femoral venous sheaths. Covered stent exclusion of the SVD was performed with concurrent device closure of the oval fossa defect using 12-36 mm atrial septal occluders. During the procedure, two patients required protective balloon inflation in the RUPV while expanding the covered stent. In one patient, a higher small accessory RUPV was intentionally left to drain into the SVC through the struts of a bare stent anchoring the covered stent in the upper SVC. In another patient, a second overlapping covered stent was used to address residual flows from a fabric tear that became apparent after balloon deflation. There were no vascular complications and only one patient exhibited an insignificant 6 mm residual flow from the caudal edge of the SVD during a follow-up of 5 to 72 months. In conclusion, the closure of both SVD and associated oval fossa defects can be successfully performed in a single procedure, with comparable procedural times and favourable mid-term outcomes.


Subject(s)
Heart Septal Defects, Atrial , Pulmonary Veins , Adult , Humans , Young Adult , Middle Aged , Vena Cava, Superior/surgery , Heart Septal Defects, Atrial/surgery , Pulmonary Veins/diagnostic imaging , Heart Atria , Echocardiography, Transesophageal , Cardiac Catheterization/methods , Treatment Outcome
8.
Catheter Cardiovasc Interv ; 102(2): 266-272, 2023 08.
Article in English | MEDLINE | ID: mdl-37403549

ABSTRACT

Improper identification of the atrial septal defect margins during surgery and inadvertent suturing of the surgical patch to the Eustachian valve of the inferior vena cava (IVC) results in the diversion of inferior venacaval blood to the left atrium causing cyanosis. This complication has been dealt so far with surgery. We report the planning and implementation of a novel transcatheter rediversion of the IVC to the right atrium using a covered stent.


Subject(s)
Cyanosis , Heart Septal Defects, Atrial , Vena Cava, Inferior , Humans , Female , Adult , Vena Cava, Inferior/surgery , Echocardiography , Cyanosis/diagnostic imaging , Cyanosis/etiology , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Hypoxia , Postoperative Complications , Treatment Outcome
9.
Ann Pediatr Cardiol ; 16(1): 48-51, 2023.
Article in English | MEDLINE | ID: mdl-37287848

ABSTRACT

Covered stent is used in large-vessel angioplasty in anticipation of vessel wall injury. Apart from aortic coarctation, they are also used in dysfunctional right ventricular outflow conduits and find a recent role in transcatheter sinus venosus defect closure. Different methods of covering stents include glue fixation, sutureless lamination, sandwich, and sintering lamination. Covered Zephyr (Sahajanand laser technology limited, Gandhinagar, India) is a new Indian-made expanded polytetrafluoroethylene-covered balloon expandable cobalt-chromium stent. Its unique C and S links prevent foreshortening. We report the first-in-man use of this new stent in severe discrete postsubclavian coarctation of aorta and its short-term follow-up imaging.

10.
Cardiol Young ; 33(10): 2041-2048, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36515000

ABSTRACT

BACKGROUND: Device embolisation is a serious adverse event during transcatheter duct closure. This study analyses risk factors for embolisation. METHODS: Demographic parameters, echocardiographic anatomy, haemodynamics, and procedural characteristics of consecutive duct closures in a tertiary centre over 8 years were analysed. Procedures complicated by embolisation were compared to uncomplicated procedures. RESULTS: Fifteen embolisations occurred during 376 procedures. All except one embolisation were in infants. The pulmonary artery: aortic pressure ratio was 0.78 ± 0.22. Embolisation was seen significantly more commonly in Type C tubular ducts. Vascular plugs were more significantly associated with embolisations. Logistic regression analysis showed device embolisation was significantly higher in age group of < 6 months compared to 6-12 months (p = 0.02), higher in those with tubular ducts versus conical ducts (p = 0.003), use of vascular plugs compared to conventional duct occluders (p = 0.05), and in duct closure with undersized devices (p = 0.001). There was no in-hospital mortality. Three patients needed surgical retrieval while others were successfully managed in catheterisation laboratory. CONCLUSIONS: Device embolisation complicates 4% of transcatheter duct closures, with need for surgery in one-fifth of them. Larger ducts with high pulmonary artery pressures in younger and smaller infants are more often associated with device embolisation. Tubular ducts are more prone for embolisation compared to usual conical ducts. Softer vascular plugs are often associated with embolisations. Intentional device undersizing to avoid vascular obstruction in small patients is a frequent risk factor for embolisation. Precise echocardiographic measurements, correct occluder choice, proper technique and additional care in patients with high pulmonary artery pressures are mandatory to minimise embolisations.


Subject(s)
Ductus Arteriosus, Patent , Embolization, Therapeutic , Septal Occluder Device , Infant , Humans , Ductus Arteriosus, Patent/surgery , Treatment Outcome , Cardiac Catheterization/methods , Embolization, Therapeutic/methods , Risk Factors , Septal Occluder Device/adverse effects
11.
Ann Pediatr Cardiol ; 15(2): 187-191, 2022.
Article in English | MEDLINE | ID: mdl-36246749

ABSTRACT

Extreme pulmonary artery hypoplasia in cyanotic malformations precludes palliative surgeries. When aortopulmonary collaterals (APC) in such patients are also hypoplastic, their unifocalization to create a neopulmonary vasculature is also hampered. Stent angioplasty of the outflow or collateral arteries may reduce hypoxia but is challenging in tortuous and atretic tracts. Fusion imaging overlays anatomical data from computed tomography during adult structural interventions, but its use is not often reported in young children with complex cyanotic malformations. This report shows utility of fusion imaging in pulmonary atresia with extremely hypoplastic pulmonary arteries and stenotic APC to guide stenting of outflow tract and collaterals.

12.
Ann Pediatr Cardiol ; 15(2): 128-137, 2022.
Article in English | MEDLINE | ID: mdl-36246750

ABSTRACT

Background: Device closure of multiple atrial septal defects (MASDs) is frequently done using a single centrally deployed septal or cribriform occluder, but multiple devices are needed for large defects separated more than 6 mm. There is a concern about complications while using multiple devices, especially in children. Methods: Patients who received multiple devices for closure of MASD were grouped according to their age and analyzed for procedural techniques, immediate and late complications. MASDs closed by a single device were not included. Balloon sizing was done when echocardiographic images were suboptimal before simultaneous device deployment through two venous accesses or sequential deployment through one access. Duration and number of antiplatelet drugs and residual flows were analyzed on follow-up. Results: Twenty-five patients received multiple devices. Balloon interrogation was performed in 16/18 adults but only in 2/7 children. Device size was 2-5 mm larger than echocardiographic defect size or equal to balloon waist. There were no procedural failures; 7/25 showed small postprocedural residual flows. Complications including embolization in one, arrhythmia in one, and cobra deformity in two were managed successfully. On a median follow-up of 5.5 years (1-12 years), residual flows disappeared in 4/7 and there were no major late complications. Conclusions: Use of multiple devices for closing MASD is feasible with good technical success. Echocardiography and balloon interrogation are the keys for success. Simultaneous deployment is often needed and sequential delivery is feasible rarely if the defects are far apart. Minor residual leaks are common but improve on follow-up. There are no significant new complications on long-term follow-up.

13.
Indian Heart J ; 74(3): 239-241, 2022.
Article in English | MEDLINE | ID: mdl-35427631

ABSTRACT

Amplatzer Paravalvular leak (PVL) plug is rectangular in shape, that might suit closure of crescentic PVL. Among 79 transcatheter PVL closures from a single center, a subgroup of 16 patients who received Amplatzer PVL plugs were analyzed. All procedures were successful, as the plug auto-oriented to the leak, without mechanical leaflet interference, though needing additional 31 devices. Two patients needed an elective re-intervention. NYHA class improved from III-IV before procedure to less than II after procedure. Complications were not directly related to the Amplatzer PVL plug. The rectangular shape for crescentic leaks, auto-orientation and non-interference with mechanical leaflets were good attributes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Cardiac Catheterization/methods , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Prosthesis Failure , Treatment Outcome
14.
Pediatr Cardiol ; 43(7): 1494-1501, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35380217

ABSTRACT

Transcatheter ruptured sinus of valsalva aneurysm (RSOVA) closure is an alternative to surgery. When a restrictive ventricular septal defect (rVSD) coexists, there are doubts about support for an occluder and persistent left ventricular (LV) dilatation. We compared the outcomes of patients from a single centre with rVSD and RSOVA after surgery or transcatheter intervention in the past 8 years in this study. Location of rVSD did not alter the approach. Compliant balloon interrogation before transcatheter closure was occasionally used to assess significance of interventricular shunt or aortic regurgitation. Procedural success and LV dimensions before and after treatment were analyzed. Seventeen patients with a mean age of 36.64 ± 12.58 years were analyzed. 12/13 catheter procedures (92%) were successful, of whom eight patients had an outlet VSD. rVSD was closed with device in one patient with perimembranous rVSD, but unaddressed in others. Four patients underwent balloon interrogation. Surgery included the single patient who failed intervention. Transcatheter group had more acute symptoms and advanced functional class than surgical group, though not significant. At a median follow-up of 4.5 (1-7.5) years, the mean LV dimensions (50.3 ± 10.1 mm and 50.1 ± 3.1 mm, p = 0.46) were not different in the transcatheter and surgical groups. Mean end-diastolic volumes (110.5 ± 42. 1 ml and 98.5 ± 37.5 ml, p = 0.91) were not significantly different either. Transcatheter RSOVA closure success was not altered by rVSD despite their location underneath the aneurysms, including outlet rVSD with defect in aortoventricular junction. Persistent LV dilatation was not observed after catheter intervention even when the VSD was not closed.


Subject(s)
Aortic Valve Insufficiency , Heart Septal Defects, Ventricular , Septal Occluder Device , Sinus of Valsalva , Adult , Aortic Valve Insufficiency/etiology , Cardiac Catheterization/methods , Heart Septal Defects, Ventricular/complications , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery , Humans , Middle Aged , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/surgery , Treatment Outcome , Young Adult
15.
PLoS Negl Trop Dis ; 16(2): e0010183, 2022 02.
Article in English | MEDLINE | ID: mdl-35192642

ABSTRACT

BACKGROUND: Snakebite is a neglected problem with a high mortality in India. There are no simple clinical prognostic tools which can predict mortality in viper envenomings. We aimed to develop and validate a mortality-risk prediction score for patients of viper envenoming from Southern India. METHODS: We used clinical predictors from a prospective cohort of 248 patients with syndromic diagnosis of viper envenoming and had a positive 20-minute whole blood clotting test (WBCT 20) from a tertiary-care hospital in Puducherry, India. We applied multivariable logistic regression with backward elimination approach. External validation of this score was done among 140 patients from the same centre and its performance was assessed with concordance statistic and calibration plots. FINDINGS: The final model termed VENOMS from the term "Viper ENvenOming Mortality Score included 7 admission clinical parameters (recorded in the first 48 hours after bite): presence of overt bleeding manifestations, presence of capillary leak syndrome, haemoglobin <10 g/dL, bite to antivenom administration time > 6.5 h, systolic blood pressure < 100 mm Hg, urine output <20 mL/h in 24 h and female gender. The lowest possible VENOMS score of 0 predicted an in-hospital mortality risk of 0.06% while highest score of 12 predicted a mortality of 99.1%. The model had a concordance statistic of 0·86 (95% CI 0·79-0·94) in the validation cohort. Calibration plots indicated good agreement of predicted and observed outcomes. CONCLUSIONS: The VENOMS score is a good predictor of the mortality in viper envenoming in southern India where Russell's viper envenoming burden is high. The score may have potential applications in triaging patients and guiding management after further validation.


Subject(s)
Daboia , Snake Bites , Animals , Antivenins/therapeutic use , Female , Humans , India/epidemiology , Prospective Studies , Snake Bites/diagnosis , Viper Venoms
16.
Ann Pediatr Cardiol ; 14(3): 302-309, 2021.
Article in English | MEDLINE | ID: mdl-34667400

ABSTRACT

BACKGROUND: Transcatheter valves provide a safe and effective alternative to surgery for treating dysfunctional right ventricular outflow tracts (RVOTs). We present our early multicenter experience of percutaneous pulmonary valve implantation (PPVI) using Melody valve (Medtronic Inc., Minneapolis, MN). METHODS: Patients with stenosed conduits or degenerated bioprosthetic valves in RVOT with combined stenosis and regurgitation were evaluated for suitability of Melody valve implantation. After undergoing an initial structured training, PPVI using Melody transcatheter pulmonary valve (TPV) was guided by an approved proctor. Conduits were serially dilated and prestented with careful coronary interrogation, and bioprosthetic valves were dilated with high-pressure balloons. Clinical and echocardiographic follow-up was performed at 6 monthly intervals. RESULTS: Fifteen patients (three females) aged 23.1 ± 9.5 years in NYHA Class II-III underwent Melody TPV implantation in four Indian centers. The underlying anatomy comprised surgically implanted bioprosthetic valves for pulmonary regurgitation (n= 5), conduit repair for pulmonary atresia (n = 4), Rastelli repair (n = 3), truncus (n = 1), and Ross procedure (n = 2). Twelve patients had more than one previous surgery. Doppler gradient decreased from 74.2 ± 21.5 mmHg to 10.2 ± 4.5 mmHg after the PPVI. At a median follow-up of 14 months (1-39 months), all the patients were in NYHA Class I with echocardiographic gradients of 8 ± 5.7 mmHg with no evidence of pulmonary regurgitation. There were no major procedural adverse events or deaths. CONCLUSIONS: Our early experience shows encouraging results of the PPVI program in India with proctored case selection and meticulous planning. It also confirms the safety and efficacy of Melody TPV for treating dysfunctional RVOT in postoperative patients.

17.
Ann Pediatr Cardiol ; 14(3): 281-292, 2021.
Article in English | MEDLINE | ID: mdl-34667398

ABSTRACT

BACKGROUND: Balloon-expandable pulmonary valves are usually not suitable for dilated native outflow tracts. METHODS: Indian Venus P-valve registry was retrospectively analyzed for efficacy, complications, and midterm outcomes. Straight valve was used in prestented conduits in patients with right ventricular pressure above two-thirds systemic pressure and/or right ventricular dysfunction. Flared valve 1-4 mm larger than balloon waist was used in native outflow in symptomatic patients, large ventricular volumes, and ventricular dysfunction. OBJECTIVES: A self-expanding porcine pericardial Venus P-valve is available in straight and flared designs.. RESULTS: Twenty-nine patients were included. Straight valve was successful in all seven conduits, reducing gradients significantly, including one patient with left pulmonary artery (LPA) stent. Flared valve was successfully implanted in 20 out of 22 native outflow tracts. Sharp edges of the older design contributed to two failures. Complications included two migrations with one needing surgery, endocarditis in one, insignificant wire-frame fractures in three, and groin vascular complication in one patient. There were no deaths or valve-related reinterventions at a mean follow-up of 47.8 ± 24.5 months (1-85 months). Modifications of technique succeeded in three patients with narrow LPA. There was significant improvement in symptoms, right ventricular volume, and pulmonary regurgitant fraction. CONCLUSION: Straight and flared Venus P-valves are safe and effective in appropriate outflow tracts. Straight valve is an alternative to balloon-expandable valves in stenosed conduits. Flared valve is suitable for large outflows up to 34 mm, including patients with LPA stenosis. Recent design modifications may correct previous technical failures. Studies should focus on durability and late complications.

18.
J Cardiol Cases ; 24(1): 23-26, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34257756

ABSTRACT

Stent angioplasty with covered stents to avoid risk of aortic injury is the preferred mode of management of coarctation of aorta in adults and older children. Severe isthmic coarctation in an adult male with uncontrolled systemic hypertension was managed at another institution using a covered stent. A proximal stent migration during deployment resulted in obstruction of transverse aortic arch and left subclavian artery and was recognized one month after the procedure. This resulted in significant aortic gradients and left arm hypoperfusion. It was managed successfully by use of snares and additional overlapping stents, the first of this type in literature. Awareness of factors leading to stent migration and techniques involved in repositioning these stents may help cardiologists who deal with these interventions. .

19.
J Invasive Cardiol ; 33(3): E165-E171, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33542160

ABSTRACT

OBJECTIVES: During transradial coronary procedures, arterial anomalies of the upper limb can lead to transradial navigation difficulties. We aimed to evaluate the incidence and impact of these anomalies on transradial procedures. METHODS: In consecutive patients undergoing transradial coronary procedures, antegrade upper-limb arterial angiography was done at the end of the procedure with the catheter tip in the subclavian artery. Radial artery angiography from the sheath was done only if the guidewire or catheter could not be navigated. Patient characteristics, upper-limb arterial anatomy, and transradial outcomes were assessed. RESULTS: Among 1195 patients, upper-limb arterial anomalies were noted in 117 patients (9.7%). High origin of the radial artery was the most common anomaly (8.1%) followed by radial artery loop (0.9%). Transradial navigation difficulties and failures were significantly more frequent in patients with these anomalies vs those without anomalies (42.7% vs 2.0% [P<.001] and 9.4% vs 0.9%, [P<.001], respectively). There was a greater need for radial road mapping and navigation assistance techniques, including balloon/pigtail assisted tracking. Passage for radial artery loop was associated with maximum navigation difficulties and higher transradial failure rate (63.6%). Fluoroscopy time, radiation dose, and transradial complications, including forearm hematoma and radial artery occlusions, were also significantly higher in patients with upper-limb arterial anomalies. CONCLUSION: Different upper-limb arterial anomalies are associated with different degrees of impact on transradial outcomes; these patients require an individualized approach for transradial navigation.


Subject(s)
Angioplasty, Balloon, Coronary , Angiography , Catheters , Humans , Radial Artery , Upper Extremity
20.
Cardiol Young ; 31(6): 949-956, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33441216

ABSTRACT

BACKGROUND: Shape-memory abnormalities are seen in some nitinol atrial septal occluders. Variably described as cobra-head, tulip, and others, their incidence, mechanisms, clinical impact, and outcome have not been systematically analysed. METHODS: We retrospectively reviewed all consecutive device closures in the last 6 years for deformations. Type and size of the occluder, deployment technique, size, and angulation/kinking of the delivery sheath were analysed. Procedural success, duration, and other complications were studied. RESULTS: A total of 112 devices (11.8%) among 950 occluders used in 936 patients showed deformities. Fourteen of 936 received 2 devices. Deformities were transient and self-correcting in 40%. Multivariate analysis showed significant associations with oversized sheaths (p = 0.004), kinked/angulated sheaths (p < 0.001), special deployment techniques (p < 0.001), and twist in the device waist (p = 0.011). Despite more frequent deformities with Figulla (15.6%) and Amplatzer (13.9%) occluders than Cera occluders (6.6%) and larger devices (>24 mm - 14.6%) than smaller devices (less than or equal to 24 mm - 9.7%), they were not significant on multivariate analysis. In vivo manipulations corrected most deformities; nineteen needed in vitro reformations and four needed a change of device. Despite prolongation of the procedure, repeated attempts (mean 2.76 ± 1.7 attempts, with a range from 1 to 9 attempts), and supraventricular tachycardia in two patients, there were no serious adverse effects. CONCLUSIONS: Deformations were frequent in 11.8% of atrial septal occluders on a targeted search. Oversized and angulated/kinked sheaths, special techniques like pulmonary vein deployment and twist in device waist during procedure predisposed to deformities. While most deformities were corrected with manipulations, removal of the device was infrequently needed and change of device was rarely required. Long procedural time and multiple attempts for deployment did not affect procedural success.


Subject(s)
Heart Septal Defects, Atrial , Septal Occluder Device , Alloys , Cardiac Catheterization , Causality , Heart Septal Defects, Atrial/epidemiology , Heart Septal Defects, Atrial/surgery , Humans , Incidence , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...