Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Polymers (Basel) ; 13(14)2021 Jul 19.
Article in English | MEDLINE | ID: mdl-34301126

ABSTRACT

The results of an experimental program on shear-strengthening of flat slabs using Glass Fiber Reinforced Polymer (GFRP) rods are presented. A total of seven specimens were tested under an upward concentric monotonic loading until failure. One specimen served as a control and was tested without any modification. The remaining six specimens were strengthened with post-installed GFRP rods in single (SG), double (DB), and radial (RD) patterns within shear critical parameters around the centric column. The results of this experimental study suggest that GFRP rods are capable of enhancing both the peak load and deformation capacity. Furthermore, brittle failure associated with punching shear failure was successfully avoided by all strengthening patterns. Of all of the patterns, the RD pattern resulted in maximum peak load increase and corresponding deformation capacity while the lowest bound was created by the SG pattern. The results suggested that SG, DB and RD patterns enhanced ultimate loads up to 9.1, 11.3 and 15.7% while corresponding deflections increased up to 109, 136 and 154%. Strain measurement on flexural reinforcement suggested that all strengthened specimens were able to withstand higher longitudinal strains than yield. It was further shown that reducing the spacing between the GFRP rods efficiently enhanced peak loads, nevertheless, neither this change was proportional, nor did it result in an enhanced energy dissipation capacity. In the end, recommendations of American Concrete Institute (ACI) for the shear strength of two-way systems were modified to incorporate the contributions from GFRP rods. The results indicate that the proposed analytical approach provides an excellent match with the experimental results.

2.
Materials (Basel) ; 14(13)2021 Jun 22.
Article in English | MEDLINE | ID: mdl-34206621

ABSTRACT

Reinforced concrete bridges were visually surveyed in Japan, Thailand, and Vietnam to study the deterioration caused by internal steel corrosion under different climates, focusing on the concrete cover depth. Spalling or cracking arising from corrosion is likely where water is supplied. According to prior studies and our surveys, a concrete cover depth of more than 40 mm was found to prevent spalling, regardless of environmental conditions and structure age. Because water supply at steel is a key corrosion factor, it was hypothesised that under natural conditions, the water penetration in concrete would remain at a depth of approximately 40 mm. Our laboratory study examined water penetration under drying and wetting conditions. The results also suggested that under periodic rainfall conditions, the threshold of water penetration was not exceeded. The numerical study indicated maximum moisture evaporation to facilitate oxygen diffusion occurred at a depth of approximately 30-40 mm unless the concrete was exposed to continuous drying for more than one month. It was experimentally and numerically concluded that an adequate cover depth of greater than 40 mm could inhibit moisture and oxygen penetration at the steel, which supported the survey findings of cover depth effect on a high resistance to corrosion-induced deterioration despite an increase in service life.

SELECTION OF CITATIONS
SEARCH DETAIL
...