Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 139
Filter
1.
Demography ; 55(2): 643-668, 2018 04.
Article in English | MEDLINE | ID: mdl-29564717

ABSTRACT

Female secondary school attendance has recently increased in sub-Saharan Africa, and so has the risk of becoming pregnant while attending school. We analyze the impact of teenage pregnancy on young women's human capital using longitudinal data in Madagascar that capture the transition from adolescence to adulthood for a cohort aged 21-24 in 2012, first interviewed in 2004. We find that early childbearing increases the likelihood of dropping out of school and decreases the chances of completing secondary school. This pregnancy-related school dropout also has a detrimental impact on standardized test scores in math and French. We instrument early pregnancy with the young woman's community-level access and her exposure to condoms since age 15 after controlling for pre-fertility socioeconomic conditions. Our results are robust to different specifications that address potential endogeneity of program placement and instrument validity.


Subject(s)
Academic Success , Condoms/supply & distribution , Pregnancy in Adolescence/statistics & numerical data , Residence Characteristics/statistics & numerical data , Student Dropouts/statistics & numerical data , Adolescent , Cognition , Female , Humans , Longitudinal Studies , Madagascar/epidemiology , Pregnancy , Socioeconomic Factors , Young Adult
2.
Echocardiography ; 35(1): 90-99, 2018 01.
Article in English | MEDLINE | ID: mdl-29082558

ABSTRACT

BACKGROUND: Quantification of defect size and shunt flow is an important aspect of ventricular septal defect (VSD) evaluation. This study compared three-dimensional echocardiography (3DE) with the current clinical standard two-dimensional echocardiography (2DE) for quantifying defect area and tested the feasibility of real time 3D color Doppler echocardiography (RT3D-CDE) for quantifying shunt volume of irregular shaped and multiple VSDs. METHODS: Latex balloons were sutured into the ventricles of 32 freshly harvested porcine hearts and were connected with tubing placed in septal perforations. Tubing was varied in area (0.13-5.22 cm²), number (1-3), and shape (circle, oval, crescent, triangle). A pulsatile pump was used to pump "blood" through the VSD (LV to RV) at stroke volumes of 30-70 mL with a stroke rate of 60 bpm. Two-dimensional echocardiography (2DE), 3DE, and RT3D-CDE images were acquired from the right side of the phantom. RESULTS: For circular VSDs, both 2DE and 3DE area measurements were consistent with the actual areas (R² = 0.98 vs 0.99). For noncircular/multiple VSDs, 3DE correlated with the actual area more closely than 2DE (R² = 0.99 vs 0.44). Shunt volumes obtained using RT3D-CDE positively correlated with pumped stroke volumes (R² = 0.96). CONCLUSIONS: Three-dimensional echocardiography (3DE) is a feasible method for determining VSD area and is more accurate than 2DE for evaluating the area of multiple or noncircular VSDs. Real-time 3D color Doppler echocardiography (RT3D-CDE) is a feasible method for quantifying the shunt volume of multiple or noncircular VSDs.


Subject(s)
Echocardiography/methods , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Ventricles/diagnostic imaging , Animals , Disease Models, Animal , Echocardiography, Doppler, Color/methods , Echocardiography, Three-Dimensional/methods , Feasibility Studies , Heart Septal Defects, Ventricular/pathology , Heart Ventricles/pathology , In Vitro Techniques , Reproducibility of Results , Swine
3.
Int J Cardiovasc Imaging ; 33(12): 1993-2001, 2017 Dec.
Article in English | MEDLINE | ID: mdl-28668979

ABSTRACT

In patients with transposition of the great arteries corrected by interatrial baffle (TGA) and those with congenitally corrected transposition of the great arteries (ccTGA) the right ventricle (RV) is subjected to systemic pressure and fails prematurely. Previous studies have demonstrated RV dysfunction may be more pronounced in patients with TGA. The present study sought to compare patients with TGA and ccTGA using three-dimensional (3D) techniques to comprehensively analyze the shape, volume, global and regional function in the systemic RV. We compared RV size, shape, and regional and global function in 25 patients with TGA, 17 patients with ccTGA, and 9 normal subjects. The RVs were reconstructed from cardiac Magnetic Resonance Images for 3D analyses. Compared to normal, the RV in TGA and ccTGA was dilated, rounded, and reduced in function. Compared to each other, TGA and ccTGA patients had similar RV size and shape. Global RV function was lower in TGA than ccTGA when assessed from ejection fraction (EF) (30 ± 7 vs. 35 ± 7, p = 0.02) and from normalized tricuspid annular systolic plane excursion (TAPSE) (0.10 ± 0.04 vs. 0.18 ± 0.04, p < 0.01). Basilar RV function was poorer in the TGA patients when compared to ccTGA. The systemic RVs in both TGA and ccTGA are dilated, spherical, and poorly functioning. Compared to ccTGA, TGA RVs have reduced TAPSE and worse basilar hypokinesis.


Subject(s)
Arterial Switch Operation/adverse effects , Transposition of Great Vessels/surgery , Ventricular Dysfunction, Right/etiology , Ventricular Function, Right , Adult , Congenitally Corrected Transposition of the Great Arteries , Female , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Magnetic Resonance Imaging/methods , Male , Middle Aged , Predictive Value of Tests , Risk Factors , Stroke Volume , Transposition of Great Vessels/complications , Transposition of Great Vessels/diagnostic imaging , Transposition of Great Vessels/physiopathology , Treatment Outcome , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/physiopathology , Young Adult
4.
Ultrasound Med Biol ; 43(10): 2247-2255, 2017 10.
Article in English | MEDLINE | ID: mdl-28716430

ABSTRACT

The aim of this study was to evaluate the accuracy and feasibility of real-time 3-D echocardiography (3-DE) in assessing right ventricular (RV) systolic function. A latex balloon was inserted into the right ventricle of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus. The RV global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and RV ejection fraction (RVEF), derived from 3-DE, as well as the RVEF obtained from 2-D echocardiography (2-DE) were quantified at different stroke volumes (30-70 mL) and compared with sonomicrometry data. In all comparisons, 3-D GLS, GCS, GAS, 2-D RVEF and 3-D RVEF exhibited strong correlations with sonomicrometry data (r = 0.89, 0.79, 0.74, 0.80, and 0.93, respectively; all p values < 0.001). Bland-Altman analyses revealed slight overestimations of echo-derived GLS, GCS, 2-DE RVEF and 3-DE RVEF compared with sonomicrometry values (bias = 1.55, 2.72, 3.59 and 2.21, respectively). Furthermore, there is better agreement among GLS, 3-D RVEF and the sonomicrometry values than between GCS and 2-D RVEF. Real-time 3-DE is more feasible and accurate for assessing RV function than 2-DE. GLS is a potential alternative parameter for quantifying RV systolic function.


Subject(s)
Echocardiography, Three-Dimensional/methods , Ventricular Function, Right/physiology , Animals , Feasibility Studies , Heart , Heart Ventricles/diagnostic imaging , Models, Animal , Reproducibility of Results , Swine
6.
PLoS One ; 11(5): e0154996, 2016.
Article in English | MEDLINE | ID: mdl-27144844

ABSTRACT

BACKGROUND: The aim of this study is to assess the accuracy and feasibility of left ventricular systolic function determined by four-dimensional echocardiography (4DE). METHODS: Latex balloons were sewn into the left ventricle (LV) of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus. Global longitudinal strain (GLS), global circumferential strain (GCS), global area strain (GAS) and left ventricular ejection fraction (LVEF) derived from 4DEand two-dimensional echocardiography (2DE)-derived LVEF were quantified at different stroke volumes (SV) 30-70 ml and correlated with sonomicrometry data. RESULTS: In all comparisons, GLS, GCS, GAS, 2DE-LVEF, and 4DE-LVEF demonstrated strong correlations with sonomicrometry data (r = 0.77, r = 0.89, r = 0.79, r = 0.93, r = 0.96, all P <0.001). Bland-Altman analyses showed slight overestimations of echo-derived GLS, GCS, 2DE-LVEF and 3DE-LVEF over sonomicrometry values (bias = 2.88, bias = 3.99, bias = 3.37, bias = 2.78, respectively). Furthermore, there is better agreement between GCS, 4D LVEF and sonomicrometry values compared with GLS and 2D LVEF. CONCLUSION: Four-dimensional echocardiography accurately assesses LV function. GCS derived by 4DE is a potential alternative parameter to quantify LV systolic function.


Subject(s)
Echocardiography, Four-Dimensional/methods , Heart Ventricles/physiopathology , Ventricular Function, Left/physiology , Animals , Echocardiography/methods , Echocardiography, Three-Dimensional/methods , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Stroke Volume/physiology , Swine , Systole/physiology , Ventricular Dysfunction, Left/physiopathology
7.
PLoS One ; 11(5): e0153634, 2016.
Article in English | MEDLINE | ID: mdl-27149685

ABSTRACT

INTRODUCTION: This study compared the variability of 3D echo derived circumferential and longitudinal strain values computed from vendor-specific and vendor-independent analyses of images acquired using ultrasound systems from different vendors. METHODS: Ten freshly harvested porcine hearts were studied. Each heart was mounted on a custom designed phantom and driven to simulate normal cardiac motion. Cardiac rotation was digitally controlled and held constant at 5°, while pumped stroke volume (SV) ranged from 30-70ml. Full-volume image data was acquired using three different ultrasound systems from different vendors. The image data was analyzed for longitudinal and circumferential strains (LS, CS) using both vendor-specific and vendor-independent analysis packages. RESULTS: Good linear relationships were observed for each vendor-specific analysis package for both CS and LS at the mid-anterior segment, with correlation coefficients ranging from 0.82-0.91 (CS) and 0.86-0.89 (LS). Comparable linear regressions were observed for results determined by a vendor independent program (CS: R = 0.82-0.89; LS: R = 0.86-0.89). Variability between analysis packages was examined via a series of ANOVA tests. A statistical difference was found between vendor-specific analysis packages (p<0.001), while no such difference was observed between ultrasound systems when using the vendor-independent program (p>0.05). CONCLUSIONS: Circumferential and longitudinal regional strain values differ when quantified by vendor-specific analysis packages; however, this variability is mitigated by use of a vendor-independent quantification method. These results suggest that echocardiograms acquired using different ultrasound systems could be meaningfully compared using vendor-independent software.


Subject(s)
Echocardiography, Three-Dimensional , Animals , Echocardiography, Three-Dimensional/standards , Heart/diagnostic imaging , Heart/physiology , Image Interpretation, Computer-Assisted , Reproducibility of Results , Swine
8.
J Ultrasound Med ; 35(5): 943-9, 2016 May.
Article in English | MEDLINE | ID: mdl-27036164

ABSTRACT

OBJECTIVES: This study tested the accuracy of new 4-dimensional fetal echocardiography to evaluate left ventricular (LV) mass in an experimental model of fetal myocardial hypertrophy. METHODS: Ten fresh rabbit hearts were studied. Fetal myocardial hypertrophy was simulated by fixing different amounts of myocardial tissue to the LV epicardium. A small latex balloon was mounted on vinyl tubing and fixed within each LV cavity. The proximal end of the tube was attached to a pulsatile pump apparatus. The pump was calibrated to deliver stroke volumes of 2 and 4 mL at stroke rates of 60 and 120 beats per minute (bpm). Four-dimensional data were acquired and analyzed with quantification software. Reference values for LV mass were determined by the displacement method. RESULTS: Echo-derived measurements of LV mass showed good correlations with reference values at all stroke rates and stroke volumes: at 2 mL and 60 bpm, r = 0.95; at 2 mL and 120 bpm, r = 0.95; at 4 mL and 60 bpm, r = 0.93; and at 4 mL and 120 bpm, r = 0.95 (P< .01 for all values). There was also excellent interobserver (r = 0.98; mean difference of -0.32 g; -4.4% of the mean) and intraobserver (r = 0.98; mean difference of -0.28 g; -3.8% of the mean) agreement. CONCLUSIONS: In this controlled in vitro study, high-resolution 4-dimensional echocardiography was shown to accurately assess LV mass and have the potential to evaluate fetal myocardial hypertrophy.


Subject(s)
Echocardiography, Three-Dimensional/methods , Fetal Heart/diagnostic imaging , Fetal Heart/pathology , Hypertrophy, Left Ventricular/diagnostic imaging , Hypertrophy, Left Ventricular/pathology , Animals , Disease Models, Animal , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , In Vitro Techniques , Rabbits , Reproducibility of Results
9.
Ultrasound Med Biol ; 42(5): 1193-200, 2016 May.
Article in English | MEDLINE | ID: mdl-26850842

ABSTRACT

Quantification of shunt volume is important for ventricular septal defects (VSDs). The aim of the in vitro study described here was to test the feasibility of using real-time 3-D color Doppler echocardiography (RT3-D-CDE) to quantify shunt volume through a modeled VSD. Eight porcine heart phantoms with VSDs ranging in diameter from 3 to 25 mm were studied. Each phantom was passively driven at five different stroke volumes from 30 to 70 mL and two stroke rates, 60 and 120 strokes/min. RT3-D-CDE full volumes were obtained at color Doppler volume rates of 15, 20 and 27 volumes/s. Shunt flow derived from RT3-D-CDE was linearly correlated with pump-driven stroke volume (R = 0.982). RT3-D-CDE-derived shunt volumes from three color Doppler flow rate settings and two stroke rate acquisitions did not differ (p > 0.05). The use of RT3-D-CDE to determine shunt volume though VSDs is feasible. Different color volume rates/heart rates under clinically/physiologically relevant range have no effect on VSD 3-D shunt volume determination.


Subject(s)
Blood Volume Determination/methods , Echocardiography, Doppler, Color/methods , Echocardiography, Three-Dimensional/methods , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/physiopathology , Stroke Volume , Animals , Blood Flow Velocity , Blood Volume , Computer Systems , Feasibility Studies , Image Interpretation, Computer-Assisted/methods , In Vitro Techniques , Reproducibility of Results , Sensitivity and Specificity , Swine
11.
Medicine (Baltimore) ; 94(47): e2085, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26632719

ABSTRACT

Aortic stenosis (AS) and aortic regurgitation (AR) are associated with congenital isolated bicuspid aortic valve (BAV) disease. The chronic pressure overload of AS and the volume overload of AR are known to impair the left ventricular function. This study assessed whether two-dimensional speckle tracking echocardiography (2D-STE) is capable of detecting the myocardial dysfunction associated with BAV caused by various aortic valve lesions in patients retaining normal ejection fraction (EF).Thirty-two isolated BAV patients and 20 healthy tricuspid aortic valve (TAV) volunteers were recruited. BAV patients were divided into 4 subgroups based on aortic valvular lesion types: normal function (NF) group, isolated AS group, isolated AR group, and a group who had both AS&AR. Myocardial strain and degree of twist were analyzed and compared between the BAV and TAV groups, as well as between valvular lesion groups and the NF group.Compared with healthy TAV controls, global radial strain (GRS), global circumferential strain (GCS), global longitudinal strain (GLS), and twist angle absolute values were lower in the BAV group (P < 0.05). The AS, AR, and AS&AR groups all demonstrated a significant decrease in GRS and GCS when compared with the TAV group. The AS and AS&AR groups demonstrated lower GLS than the TAV group, and the smallest degree of twist was detected in the AR group. There were no significant differences between the NF and TAV groups. The AR and AS&AR groups demonstrated significant differences in multiple parameters of cardiac mechanics compared with the NF group.2D-STE is able to detect altered cardiac mechanics associated with aortic lesion types in BAV patients with normal EF compared with normal TAV controls, and so can provide valuable information for clinical decision-making.


Subject(s)
Aortic Valve Insufficiency/complications , Aortic Valve Stenosis/complications , Aortic Valve/abnormalities , Echocardiography/methods , Heart Valve Diseases/complications , Heart Valve Diseases/diagnostic imaging , Adult , Aortic Valve/diagnostic imaging , Bicuspid Aortic Valve Disease , Female , Hemodynamics , Humans , Male , Middle Aged , Stroke Volume
12.
Biomed Res Int ; 2015: 765921, 2015.
Article in English | MEDLINE | ID: mdl-26236735

ABSTRACT

Left atrial (LA) functional analysis has an established role in assessing left ventricular diastolic function. The current standard echocardiographic parameters used to study left ventricular diastolic function include pulsed-wave Doppler mitral inflow analysis, tissue Doppler imaging measurements, and LA dimension estimation. However, the above-mentioned parameters do not directly quantify LA performance. Deformation studies using strain and strain-rate imaging to assess LA function were validated in previous research, but this technique is not currently used in routine clinical practice. This review discusses the history, importance, and pitfalls of strain technology for the analysis of LA mechanics.


Subject(s)
Atrial Function, Left , Echocardiography, Doppler, Pulsed , Ventricular Function, Left , Animals , Echocardiography, Doppler, Pulsed/history , Echocardiography, Doppler, Pulsed/methods , Heart Atria/diagnostic imaging , History, 19th Century , History, 20th Century , History, 21st Century , Humans
13.
Int J Cardiol ; 196: 178-82, 2015 Oct 01.
Article in English | MEDLINE | ID: mdl-26142077

ABSTRACT

BACKGROUND: The adoption of electronic health records (EHR) has created an opportunity for multicenter data collection, yet the feasibility and reliability of this methodology is unknown. The aim of this study was to integrate EHR data into a homogeneous central repository specifically addressing the field of adult congenital heart disease (ACHD). METHODS: Target data variables were proposed and prioritized by consensus of investigators at five target ACHD programs. Database analysts determined which variables were available within their institutions' EHR and stratified their accessibility, and results were compared between centers. Data for patients seen in a single calendar year were extracted to a uniform database and subsequently consolidated. RESULTS: From 415 proposed target variables, only 28 were available in discrete formats at all centers. For variables of highest priority, 16/28 (57%) were available at all four sites, but only 11% for those of high priority. Integration was neither simple nor straightforward. Coding schemes in use for congenital heart diagnoses varied and would require additional user input for accurate mapping. There was considerable variability in procedure reporting formats and medication schemes, often with center-specific modifications. Despite the challenges, the final acquisition included limited data on 2161 patients, and allowed for population analysis of race/ethnicity, defect complexity, and body morphometrics. CONCLUSION: Large-scale multicenter automated data acquisition from EHRs is feasible yet challenging. Obstacles stem from variability in data formats, coding schemes, and adoption of non-standard lists within each EHR. The success of large-scale multicenter ACHD research will require institution-specific data integration efforts.


Subject(s)
Automation/methods , Data Collection/methods , Databases, Factual , Electronic Health Records , Heart Defects, Congenital/diagnosis , Adult , Clinical Coding , Female , Humans , Male , Middle Aged , Young Adult
14.
Popul Stud (Camb) ; 69(2): 219-36, 2015.
Article in English | MEDLINE | ID: mdl-26217889

ABSTRACT

The low school attainment, early marriage, and low age at first birth of females are major policy concerns in less developed countries. This study jointly estimated the determinants of educational attainment, marriage age, and age at first birth among females aged 12-25 in Madagascar, explicitly accounting for the endogeneities that arose from modelling these related outcomes simultaneously. An additional year of schooling results in a delay to marriage of 1.5 years and marrying 1 year later delays age at first birth by 0.5 years. Parents' education and wealth also have important effects on schooling, marriage, and age at first birth, with a woman's first birth being delayed by 0.75 years if her mother had 4 additional years of schooling. Overall, our results provide rigorous evidence for the critical role of education-both individual women's own and that of their parents-in delaying the marriage and fertility of young women.


Subject(s)
Educational Status , Fertility , Marriage/statistics & numerical data , Maternal Age , Adolescent , Age Factors , Birth Order , Child , Developed Countries , Female , Humans , Madagascar , Parturition/ethnology , Population Dynamics , Schools , Socioeconomic Factors , Young Adult
16.
Echocardiography ; 32(11): 1697-706, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25865121

ABSTRACT

BACKGROUND: Left ventricular stroke volume, mass, and myocardial strain are valuable indicators of fetal heart function. This study investigated the feasibility of nongated real time three-dimensional echocardiography (RT3DE) to determine fetal stroke volume (SV), left ventricular mass (LVM), and myocardial strain under different conditions. METHODS: To evaluate fetal hearts, fetal-sized rabbit hearts were used in this study. The in vitro portion of this study was carried out using a balloon inserted into the LV of eight fresh rabbit hearts and driven by a calibrated pulsatile pump. RT3DE volumes were obtained at various pump-set SVs. The in vivo experiments in this study were performed on open-chest rabbits. RT3DE volumes were acquired at the following conditions: baseline, simulated hypervolemia, inferior vena cava (IVC) ligation, and ascending aorta (AAO) ligation. Displacement values and sonomicrometry data were used as references for RT3DE-derived SV, LVM, longitudinal strain (LS), and circumferential strain (CS). RESULTS: Excellent correlations between RT3DE-derived values and reference values were demonstrated and accompanied by high coefficients of determination (R(2) ) for both in vitro and in vivo studies for SV, LVM, LS, and CS (in vitro: SV: R(2)  = 0.98; LVM: R(2)  = 0.97; LS: R(2)  = 0.87, CS: R(2)  = 0.80; in vivo: SV: R(2)  = 0.92; LVM: R(2)  = 0.98; LS: in vivo: R(2)  = 0.84; CS: in vivo: R(2)  = 0.76; all P < 0.05). CONCLUSIONS: RT3DE is capable of quantifying the SV, LVM, and myocardial strain of fetal-sized hearts under different conditions. This nongated RT3DE may aid the evaluation of fetal cardiac function, providing a superior understanding of the progress of fetal heart disorders.


Subject(s)
Echocardiography, Three-Dimensional , Fetal Heart/diagnostic imaging , Fetal Heart/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Stroke Volume/physiology , Animals , Disease Models, Animal , Female , Heart Ventricles/pathology , In Vitro Techniques , Organ Size , Rabbits , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/pathology , Ventricular Dysfunction, Left/physiopathology
17.
Cardiol Young ; 25(7): 1358-66, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25668304

ABSTRACT

OBJECTIVE: To quantify myocardial blood flow in infants and children with mild or moderate aortic stenosis using adenosine-infusion cardiac magnetic resonance. BACKGROUND: It is unclear whether asymptomatic children with mild/moderate aortic stenosis have myocardial abnormalities. In addition, cardiac magnetic resonance-determined normative myocardial blood flow data in children have not been reported. METHODS: We studied 31 infants and children with either haemodynamically normal hearts (n=20, controls) or mild/moderate aortic stenosis (n=11). The left ventricular myocardium was divided into six segments, and the change in average segmental signal intensity during contrast transit was used to quantify absolute flow (ml/g/minute) at rest and during adenosine infusion by deconvolution of the tissue curves with the arterial input of contrast. RESULTS: In all the cases, adenosine was well tolerated without complications. The mean pressure gradient between the left ventricle and the ascending aorta was higher in the aortic stenosis group compared with controls (24 versus 3 mmHg, p<0.001). Left ventricular wall mass was slightly higher in the aortic stenosis group compared with controls (65 versus 50 g/m², p<0.05). After adenosine treatment, both the absolute increase in myocardial blood flow (p<0.0001) and the hyperaemic flow significantly decreased (p<0.001) in children with mild/moderate aortic stenosis compared with controls. CONCLUSION: Abnormal myocardial blood flow in children with mild/moderate aortic stenosis may be an important therapeutic target.


Subject(s)
Adenosine/administration & dosage , Aortic Valve Stenosis/complications , Coronary Circulation/physiology , Heart Ventricles/physiopathology , Ventricular Function, Left/physiology , Adolescent , Blood Flow Velocity , Child , Child, Preschool , Contrast Media , Female , Humans , Infant , Male
18.
Ultrasound Med Biol ; 41(4): 1020-8, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25701524

ABSTRACT

We investigated the effect of fetal sheep ductus arteriosus occlusion (DO) on the distribution of cardiac output and left and right ventricular function by tissue and pulsed Doppler at baseline; after 15 and 60 min of DO induced with a vascular occluder; and 15 min after release of DO. Ductal occlusion decreased fetal pO2. Mean left ventricular output increased (p < 0.001) from 725 to 1013 mL/min, and right ventricular (1185 mL/min vs. 552 mL/min) and systemic (1757 mL/min vs. 1013 mL/min) cardiac outputs fell (p < 0.001) after 15 min of DO, compared with baseline. Pulmonary vascular impedance decreased and volume blood flow increased more than threefold during DO, whereas foramen ovale volume blood flow remained unchanged. Left ventricular systolic function was unaffected, whereas isovolumic relaxation velocity deceleration decreased. Right ventricular functional indices remained unchanged. We conclude that DO increased pulmonary volume blood flow, not foramen ovale volume blood flow. Left ventricular output increased, although not as much as right ventricular output fell, resulting in decreased systemic cardiac output. During DO, left ventricular function exhibited diminished relaxation.


Subject(s)
Ductus Arteriosus/diagnostic imaging , Fetal Heart/diagnostic imaging , Heart Ventricles/diagnostic imaging , Ventricular Dysfunction/diagnostic imaging , Animals , Cardiac Output/physiology , Constriction, Pathologic , Disease Models, Animal , Ductus Arteriosus/physiopathology , Echocardiography, Doppler , Female , Fetal Heart/physiopathology , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Pregnancy , Sheep , Ventricular Dysfunction/physiopathology
19.
J Ultrasound Med ; 34(1): 95-103, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25542944

ABSTRACT

OBJECTIVES: Noninvasive quantification of left ventricular (LV) stroke volumes has an important clinical role in assessing circulation and monitoring therapeutic interventions for cardiac disease. This study validated the accuracy of a real-time 3-dimensional (3D) color flow Doppler method performed during transthoracic echocardiography (TTE) for quantifying volume flows through the mitral and aortic valves using a dedicated offline 3D flow computation program compared to LV sonomicrometry in an open-chest animal model. METHODS: Forty-six different hemodynamic states in 5 open-chest pigs were studied. Three-dimensional color flow Doppler TTE and 2-dimensional (2D) TTE were performed by epicardial scanning. The dedicated software was used to compute flow volumes at the mitral annulus and the left ventricular outflow tract (LVOT) with the 3D color flow Doppler method. Stroke volumes by 2D TTE were computed in the conventional manner. Stroke volumes derived from sonomicrometry were used as reference values. RESULTS: Mitral inflow and LVOT outflow derived from the 3D color flow Doppler method correlated well with stroke volumes by sonomicrometry (R = 0.96 and 0.96, respectively), whereas correlation coefficients for mitral inflow and LVOT outflow computed by 2D TTE and stroke volumes by sonomicrometry were R = 0.84 and 0.86. Compared to 2D TTE, the 3D method showed a smaller bias and narrower limits of agreement in both mitral inflow (mean ± SD: 3D, 2.36 ± 2.86 mL; 2D, 10.22 ± 8.46 mL) and LVOT outflow (3D, 1.99 ± 2.95 mL; 2D, 4.12 ± 6.32 mL). CONCLUSIONS: Real-time 3D color flow Doppler quantification is feasible and accurate for measurement of mitral inflow and LVOT outflow stroke volumes over a range of hemodynamic conditions.


Subject(s)
Aorta/diagnostic imaging , Echocardiography, Doppler, Color , Echocardiography, Three-Dimensional , Mitral Valve/diagnostic imaging , Stroke Volume , Animals , Aorta/physiology , Female , Mitral Valve/physiology , Reproducibility of Results , Swine
20.
Echocardiography ; 32(2): 339-48, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24815184

ABSTRACT

BACKGROUND: Three-dimensional echocardiography (3DE) is a promising method for strain determination; however, there are temporal resolution concerns. This study aims to evaluate the feasibility and accuracy of 3DE on longitudinal and circumferential strain (LS, CS) determination and infarction detection under variable frame rates (FR) and "heart rates" (stroke rates [SR]) conditions. METHODS: Latex balloons were sewn into the left ventricle (LV) of 20 freshly harvested pig hearts which were then passively driven by a pulsatile pump apparatus at stroke volumes (SV) 30-70 mL. The hearts were pumped at 2 normal limits of human heart rate. Full-volume data were acquired before and after a simulated myocardial infarction (MI) at the 2 most commonly used FRs. LS and CS values were evaluated against sonomicrometry. RESULTS: Longitudinal strain and CS derived from high FR acquisitions showed statistically superior correlations with sonomicrometry data (LS: R(2) = 0.85, CS: R(2) = 0.84) than strain values from low FR (LS: R(2) = 0.78, CS: R(2) = 0.76) (all P < 0.01). After MI induction, LS and CS at different FRs were significantly decreased while maintaining excellent correlations with sonomicrometry data (all P < 0.001). There is no statistical difference of strain values between different SR acquisitions. CONCLUSION: Three-dimensional wall-motion tracking has the ability to accurately determine regional myocardial deformation and detect MI. Different heart rates within a physiologically relevant range have no effect on 3D strain accuracy. Strain values calculated from higher frame rate acquisitions were found to have a slightly better accuracy.


Subject(s)
Echocardiography, Three-Dimensional , Myocardial Infarction/diagnostic imaging , Animals , Disease Models, Animal , Reproducibility of Results , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...