Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 91: 73-80, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24440824

ABSTRACT

A sensitive ultra-performance liquid chromatography (UPLC) method was developed for simultaneous estimation of all-trans retinoic acid (ATRA) and cholecalciferol (vitamin D3) in rat plasma. The method was validated over the linear range of 1.0-5000ng/ml (r(2)=0.999) for both vitamins with a limit of detection of 0.5ng/ml. Chromatographic separation was achieved using liquid-liquid extraction (LLE) on an Acquity BEH RP 18 column (2.1mm×50mm, I.D. 1.7µm), with mobile phase comprising of acetonitrile:methanol:water (90:8:2, v/v/v), at a flow rate of 0.20ml/min and a total run time of 5min. Intra and inter-day variability (RSD) was ≤3.1%, and the accuracy varied between 95.4-99.9% and 95.3-101.1% respectively, for ATRA and 98.5-100.8% and 99.3-101.7%, respectively for vitamin D3. High recovery of ≥96.0% for ATRA and ≥87.80% for vitamin D3 was achieved. ATRA and vitamin D3 were stable in plasma under different storage and processing conditions. The method was applied to estimate the total drug content and entrapment efficiency of ATRA and vitamin D3 loaded solid lipid nanoparticles (SLNs). Concentration of these two agents was determined in rat plasma after simultaneous subcutaneous administration in free form or when loaded into SLNs thus establishing pharmacokinetic application of the developed procedure. Results indicated an improvement in AUC0-∞ by 5.4 times and 29.4 times for ATRA and vitamin D3, respectively, upon their incorporation into SLNs. Simultaneous administration of these two vitamins and their improved and prolonged bioavailability has scope for their use in treatment and control of tuberculosis.


Subject(s)
Cholecalciferol/chemistry , Cholecalciferol/pharmacokinetics , Chromatography, High Pressure Liquid/methods , Lipids/chemistry , Nanoparticles/chemistry , Tretinoin/chemistry , Animals , Biological Availability , Limit of Detection , Liquid-Liquid Extraction/methods , Male , Plasma/chemistry , Rats , Rats, Wistar
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 878(32): 3427-31, 2010 Dec 15.
Article in English | MEDLINE | ID: mdl-21111692

ABSTRACT

A simple and sensitive validated LC-MS/MS analytical method was used for determination of curcumin in rat plasma, using nimesulide as internal standard. Analyses were performed on an Agilent LC-MS/MS system using a Chromolith rod™ and isocratic elution with acetonitrile:10 mM ammonium acetate buffer (pH 3.5) (80:20, v/v) at a flow rate of 0.8 ml/min with a total run time of 3 min and an overall recovery of 77.15%. A triple quadrupole mass spectrometer, equipped with an electrospray ionization interface, operated in the negative mode was used. Calibration curve in plasma spiked with varying concentration of curcumin were linear over the concentration range of 10-2000 ng/ml with determination coefficient >0.99. The lower limit of quantification was 10 ng/ml. Intra and inter-day variability's (RSD) for extraction of curcumin from plasma were less than 10% and 15% respectively and accuracy was 102.43-108.5%. Multiple reaction monitoring was used to monitor the transition for curcumin (m/z; 367/217 [M-H](-)) and IS (m/z; 307/229). The method was applied for determining curcumin concentration in plasma after peroral administration of 50 mg/kg of free curcumin (C-S) or curcumin loaded solid lipid nanoparticles (C-SLNs) to rats. Results established selectivity and suitability of the method for pharmacokinetic studies of curcumin from C-SLNs.


Subject(s)
Chromatography, Liquid/methods , Curcumin/pharmacokinetics , Nanoparticles/administration & dosage , Tandem Mass Spectrometry/methods , Administration, Oral , Animals , Curcumin/administration & dosage , Curcumin/chemistry , Drug Delivery Systems , Least-Squares Analysis , Male , Nanoparticles/chemistry , Rats , Rats, Wistar , Reproducibility of Results , Sensitivity and Specificity , Sulfonamides/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...