Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
J Arthroplasty ; 2024 Sep 12.
Article in English | MEDLINE | ID: mdl-39277060

ABSTRACT

BACKGROUND: This study aimed to develop an artificial intelligence-based surgical support model for assessing the acetabular component angle using intraoperative radiographs during total hip arthroplasty and verify its accuracy. METHODS: A total of 268 hips were analyzed. At first, 268 preoperative and intraoperative anteroposterior pelvic radiographs were amplified to 536. These radiographs were used to create a learning model to estimate the acetabular component angle from the radiographs intraoperatively. The ground truth was the anteversion and inclination angles obtained from the computed tomography-based navigation system intraoperatively. Bone landmarks on the preoperative and intraoperative radiographs were manually annotated. The distances and angles between each landmark were used as predictor variables. The estimation accuracy was assessed for internal and external test datasets. Mean absolute error (MAE) and R2 values were used as accuracy measures. RESULTS: The MAE and R2 for the internal test set showed 2.19 and 0.850 for anteversion, and 1.18 and 0.805 for inclination, respectively. The MAE and R2 for the external test set showed 2.78 and 0.789 for anteversion, and 1.56 and 0.744 for inclination, respectively. CONCLUSIONS: We developed an artificial intelligence-based surgical support model for accurately assessing the acetabular component angle using intraoperative radiographs. Excellent estimation accuracy was confirmed for the external test set. In the future, the model may help to reduce the risk of adverse postoperative events.

2.
BMC Musculoskelet Disord ; 24(1): 856, 2023 Oct 31.
Article in English | MEDLINE | ID: mdl-37907894

ABSTRACT

BACKGROUND: Perioperative greater trochanteric fracture following total hip arthroplasty (THA) using the anterolateral approach is a recognized perioperative complication. There was no previous study to determine the relationship between bone mineral density (BMD) and three-dimensional greater trochanter morphology for perioperative greater trochanter fractures. The purpose of this study is to identify the influence of greater trochanteric bone density and three-dimensional morphology on perioperative greater trochanteric fracture following THA using the anterolateral approach. METHODS: We investigated 209 hips done primary THA using the anterolateral approach and preoperative BMD test for the proximal femoral bone with a minimum of 6 months follow-up. We picked up all patients who had perioperative greater trochanteric fractures. Multivariate analysis was done in order to investigate the influence of the greater trochanter young adult mean (YAM) and three-dimensional morphology on perioperative greater trochanteric fractures. RESULTS: There were 10 joints (10/209, 4.8%) with perioperative greater trochanteric fractures. Osteosynthesis was required only in one joint (1/209, 0.5%) because the bone fragments were significantly displaced proximally by the gluteus medius. Multivariate analysis showed the combination of Type B femoral shape (in cases where the top of the great trochanter was inside the longitudinal central axis of the planned femoral stem in computed tomography (CT)- based three-dimensional templating) and a YAM of < 80% was the only risk factor for fracture. CONCLUSIONS: The preoperative greater trochanter BMD test (YAM < 80%) and three-dimensional femoral morphology (Type B femoral shape) provide useful information to mitigate the occurrence of perioperative greater trochanter fractures associated with THA using the anterolateral approach.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Fractures , Young Adult , Humans , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Bone Density , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Hip Fractures/etiology , Femur/diagnostic imaging , Femur/surgery , Hip/surgery
3.
Bioengineering (Basel) ; 10(5)2023 May 10.
Article in English | MEDLINE | ID: mdl-37237645

ABSTRACT

Adipose-derived stem cells (ADSCs) have been studied for many years as a therapeutic option for osteoarthritis (OA); however, their efficacy remains insufficient. Since platelet-rich plasma (PRP) induces chondrogenic differentiation in ADSCs and the formation of a sheet structure by ascorbic acid can increase the number of viable cells, we hypothesized that the injection of chondrogenic cell sheets combined with the effects of PRP and ascorbic acid may hinder the progression of OA. The effects of induction of differentiation by PRP and formation of sheet structure by ascorbic acid on changes in chondrocyte markers (collagen II, aggrecan, Sox9) in ADSCs were evaluated. Changes in mucopolysaccharide and VEGF-A secretion from cells injected intra-articularly in a rabbit OA model were also evaluated. ADSCs treated by PRP strongly chondrocyte markers, including type II collagen, Sox9, and aggrecan, and their gene expression was maintained even after sheet-like structure formation induced by ascorbic acid. In this rabbit OA model study, the inhibition of OA progression by intra-articular injection was improved by inducing chondrocyte differentiation with PRP and sheet structure formation with ascorbic acid in ADSCs.

4.
Bone Joint Res ; 12(5): 313-320, 2023 May 08.
Article in English | MEDLINE | ID: mdl-37150521

ABSTRACT

We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measurement of knee range of motion after total knee arthroplasty (TKA), in comparison to radiography and goniometry. In this prospective observational study, we analyzed 35 primary TKAs (24 patients) for knee osteoarthritis. We measured the knee angles in flexion and extension using OpenPose, radiography, and goniometry. We assessed the test-retest reliability of each method using intraclass correlation coefficient (1,1). We evaluated the ability to estimate other measurement values from the OpenPose value using linear regression analysis. We used intraclass correlation coefficients (2,1) and Bland-Altman analyses to evaluate the agreement and error between radiography and the other measurements. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1,1) = 1.000). The R2 of all regression models indicated large correlations (0.747 to 0.927). In the flexion position, the intraclass correlation coefficients (2,1) of OpenPose indicated excellent agreement (0.953) with radiography. In the extension position, the intraclass correlation coefficients (2,1) indicated good agreement of OpenPose and radiography (0.815) and moderate agreement of goniometry with radiography (0.593). OpenPose had no systematic error in the flexion position, and a 2.3° fixed error in the extension position, compared to radiography. OpenPose is a reliable and valid tool for measuring flexion and extension positions after TKA. It has better accuracy than goniometry, especially in the extension position. Accurate measurement values can be obtained with low error, high reproducibility, and no contact, independent of the examiner's skills.

5.
Sci Rep ; 13(1): 3949, 2023 03 09.
Article in English | MEDLINE | ID: mdl-36894548

ABSTRACT

Periprosthetic joint infection (PJI) is characterized by biofilm infection, which is difficult to alleviate while preserving implant integrity. Furthermore, long-term antibiotic therapy may increase the prevalence of drug-resistant bacterial strains, necessitating a non-antibacterial approach. Adipose-derived stem cells (ADSCs) exert antibacterial effects; however, their efficacy in PJI remains unclear. This study investigates the efficacy of combined intravenous ADSCs and antibiotic therapy in comparison to antibiotic monotherapy in a methicillin-sensitive Staphylococcus aureus (MSSA)-infected PJI rat model. The rats were randomly assigned and equally divided into 3 groups: no-treatment group, antibiotic group, ADSCs with antibiotic group. The ADSCs with antibiotic group exhibited the fastest recovery from weight loss, with lower bacterial counts (p = 0.013 vs. no-treatment group; p = 0.024 vs. antibiotic group) and less bone density loss around the implants (p = 0.015 vs. no-treatment group; p = 0.025 vs. antibiotic group). The modified Rissing score was used to evaluate localized infection on postoperative day 14 and was the lowest in the ADSCs with antibiotic group; however, no significant difference was observed between the antibiotic group and ADSCs with antibiotic group (p < 0.001 vs. no-treatment group; p = 0.359 vs. antibiotic group). Histological analysis revealed a clear, thin, and continuous bony envelope, a homogeneous bone marrow, and a defined, normal interface in the ADSCs with antibiotic group. Moreover, the expression of cathelicidin expression was significantly higher (p = 0.002 vs. no-treatment group; p = 0.049 vs. antibiotic group), whereas that of tumor necrosis factor (TNF)-α and interleukin(IL)-6 was lower in the ADSCs with antibiotic group than in the no-treatment group (TNF-α, p = 0.010 vs. no-treatment group; IL-6, p = 0.010 vs. no-treatment group). Thus, the combined intravenous ADSCs and antibiotic therapy induced a stronger antibacterial effect than antibiotic monotherapy in a MSSA-infected PJI rat model. This strong antibacterial effect may be related to the increased cathelicidin expression and decreased inflammatory cytokine expression at the site of infection.


Subject(s)
Arthritis, Infectious , Mesenchymal Stem Cells , Prosthesis-Related Infections , Rats , Animals , Adipose Tissue , Prosthesis-Related Infections/drug therapy , Cathelicidins , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Tumor Necrosis Factor-alpha , Arthritis, Infectious/drug therapy
6.
Geriatr Orthop Surg Rehabil ; 14: 21514593231160916, 2023.
Article in English | MEDLINE | ID: mdl-36875966

ABSTRACT

Introduction: The effects of postoperative early weight-bearing (WB) on walking ability, muscle mass, and sarcopenia have been investigated. Postoperative WB restriction is also reportedly associated with pneumonia and prolonged hospitalization; however, its effect on surgical failures has not been studied. This study aimed to assess whether WB restriction after surgery for trochanteric fracture of the femur (TFF) is useful in preventing surgical failure, considering the unstable fracture type, quality of intraoperative reduction, and tip-apex distance. Patients and Methods: This retrospective analysis included 301 patients admitted to a single institution between January 2010 and December 2021, diagnosed with TFF, and who underwent femoral nail surgery. Eight patients were excluded, and finally 293 patients were included in the study. Propensity score (PS) matching yielded 123 cases; 41 patients in the non-WB (NWB) group and 82 patients in the WB group were included in the final analysis. The primary outcome was surgical failure (cutout, nonunion, osteonecrosis, and implant failure). The secondary outcomes were medical complications (pneumonia, urinary tract infection, stroke, and heart failure), change in walking ability, period of hospitalization, and sliding distance of the lag screw. Results: Five surgical complications occurred in the NWB group and two in the WB group, with significantly more surgical complications in the NWB group (P = .041). Cutout occurred in two cases, each in the NWB and WB groups. Two cases of nonunion and one case of implant failure occurred in the NWB group, but not in the WB group. Osteonecrosis did not occur in both groups. The secondary outcomes were not significantly different between the two groups. Conclusions: The results of this retrospective cohort study using a PS matching approach showed that WB restriction after TFF surgery could not decrease the incidence of surgical failures.

7.
Sci Rep ; 13(1): 3297, 2023 02 25.
Article in English | MEDLINE | ID: mdl-36841842

ABSTRACT

We aimed to assess the reliability and validity of OpenPose, a posture estimation algorithm, for measuring hip-knee-ankle (HKA) angle in patients with knee osteoarthritis, by comparing it with radiography. In this prospective study, we analysed 60 knees (30 patients) with knee osteoarthritis. We measured HKA angle using OpenPose and radiography before or after total knee arthroplasty and assessed the test-retest reliability of each method with intraclass correlation coefficient (1, 1). We evaluated the ability to estimate the radiographic measurement values from the OpenPose values using linear regression analysis and used intraclass correlation coefficients (2, 1) and Bland-Altman analyses to evaluate the agreement and error between OpenPose and radiographic measurements. OpenPose had excellent test-retest reliability (intraclass correlation coefficient (1, 1) = 1.000) and excellent agreement with radiography (intraclass correlation coefficient (2, 1) = 0.915), with regression analysis indicating a large correlation (R2 = 0.865). OpenPose also had a 1.1° fixed error and no systematic error when compared with radiography. This is the first study to validate the use of OpenPose for the estimation of HKA angle in patients with knee osteoarthritis. OpenPose is a reliable and valid tool for measuring HKA angle in patients with knee osteoarthritis. OpenPose, which enables non-invasive and simple measurements, may be a useful tool to assess changes in HKA angle and monitor the progression and post-operative course of knee osteoarthritis. Furthermore, this validated tool can be used not only in clinics and hospitals, but also at home and in training gyms; thus, its use could potentially be expanded to include self-assessment/monitoring.


Subject(s)
Osteoarthritis, Knee , Humans , Osteoarthritis, Knee/surgery , Ankle , Prospective Studies , Reproducibility of Results , Knee Joint/surgery
8.
Arthroplast Today ; 17: 66-73, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36042941

ABSTRACT

Background: Predicting the worsening of flexion range of motion (ROM) during the course post-total knee arthroplasty (TKA) is clinically meaningful. This study aimed to create a model that could predict the worsening of knee flexion ROM during the TKA course using a machine learning algorithm and to examine its accuracy and predictive variables. Methods: Altogether, 344 patients (508 knees) who underwent TKA were enrolled. Knee flexion ROM worsening was defined as ROM decrease of ≥10° between 1 month and 6 months post-TKA. A predictive model for worsening was investigated using 31 variables obtained retrospectively. 5 data sets were created using stratified 5-fold cross-validation. Total data (n = 508) were randomly divided into training (n = 407) and test (n = 101) data. On each data set, 5 machine learning algorithms (logistic regression, support vector machine, multilayer perceptron, decision tree, and random forest) were applied; the optimal algorithm was decided. Then, variables extracted using recursive feature elimination were combined; by combination, random forest models were created and compared. The accuracy rate and area under the curve were calculated. Finally, the importance of variables was calculated for the most accurate model. Results: The knees were classified into the worsening (n = 124) and nonworsening (n = 384) groups. The random forest model with 3 variables had the highest accuracy rate, 0.86 (area under the curve, 0.72). These variables (importance) were joint-line change (1.000), postoperative femoral-tibial angle (0.887), and hemoglobin A1c (0.468). Conclusions: The random forest model with the above variables is useful for predicting the worsening of knee flexion ROM during the course post-TKA.

9.
BMC Musculoskelet Disord ; 23(1): 609, 2022 Jun 24.
Article in English | MEDLINE | ID: mdl-35739487

ABSTRACT

BACKGROUND: A chronic expanding hematoma (CEH) is a rare complication caused by surgery or trauma; it mostly affects the soft tissues, such as those in the trunk or extremities. We present the first case of a large intraosseous CEH presenting with chronic disseminated intravascular coagulation (DIC), 22 years after total hip arthroplasty (THA); the CEH was treated with a single-stage excision and revision THA. CASE PRESENTATION: A 67-year-old man presented to our hospital with left thigh pain and an enlarging mass. He had no history of trauma, anticoagulant use, or a collagen vascular disorder. The patient initially declined surgery. Two years later, radiographs and computed tomography images revealed progressive osteolysis, marginal sclerosis, and calcification in the left femur, in addition to loosening of the femoral component. Laboratory data revealed anemia and chronic DIC of unknown causes. Magnetic resonance imaging revealed a "mosaic sign" on the mass, indicating a mix of low- and high-signal intensities on T2-weighted images. Needle biopsy prior to surgery revealed no infection or malignant findings. An intraosseous CEH was suspected due to extensive osteolysis and loosening of the femoral component. No other factors that could induce chronic DIC were identified, such as sepsis, leukemia, cancer, trauma, liver disease, aneurysms, or hemangiomas. Therefore, we speculated that the anemia and chronic DIC were caused by the large intraosseous CEH. A single-stage revision THA with surgical excision was performed to preserve the hip function and improve the chronic DIC. The postoperative histopathological findings were consistent with an intraosseous CEH. The anemia and chronic DIC improved after 7 days. There was no recurrence of intraosseous CEH or chronic DIC at the 6-month follow-up. The left thigh pain improved, and the patient could ambulate with the assistance of a walking frame. CONCLUSIONS: The loosening of the femoral component caused persistent movement, which may have caused intraosseous CEH growth, anemia, and chronic DIC. It is important to differentiate CEHs from malignant tumors with hematomas. Furthermore, the "mosaic sign" noted in this case has also been observed on magnetic resonance images in other cases of CEH.


Subject(s)
Arthroplasty, Replacement, Hip , Disseminated Intravascular Coagulation , Osteolysis , Aged , Arthroplasty, Replacement, Hip/adverse effects , Chronic Disease , Disseminated Intravascular Coagulation/complications , Disseminated Intravascular Coagulation/etiology , Hematoma/diagnostic imaging , Hematoma/etiology , Hematoma/surgery , Humans , Male , Osteolysis/surgery , Pain/surgery
10.
J Arthroplasty ; 37(4): 652-658, 2022 04.
Article in English | MEDLINE | ID: mdl-34968651

ABSTRACT

BACKGROUND: This report seeks to clarify whether the dosage and duration of preoperative concurrent corticosteroid use influence postoperative complications after primary total joint arthroplasty (TJA). METHODS: This retrospective single institutional study enrolled 1128 primary TJA cases, including 905 total hip arthroplasties and 223 total knee arthroplasties at a minimum 6 months of follow-up. Mean follow-up period was 51.9 ± 34.1 months (range 6-146). Of all joints, 120 joints (10.6%) were associated with chronic concurrent oral corticosteroid use. Multivariate analysis was performed to identify whether chronic concurrent oral corticosteroid use elevated the risk of postoperative complications including surgical site infection/periprosthetic joint infection, delayed wound healing, periprosthetic fracture, and implant loosening. For chronic concurrent oral corticosteroid user, we determined whether the dosage and duration of preoperative concurrent corticosteroid use influenced postoperative complications and have an effective threshold for postoperative complications using receiver operating characteristic curve analysis. RESULTS: The multivariate analysis revealed that American Society of Anesthesiologist Physical Status 3 was an independent risk factor for postoperative complications, while concurrent oral corticosteroid use was not an independent risk factor. When we compared joints with (n = 13) and without (n = 107) postoperative complications in chronic concurrent oral corticosteroid user, there was no statistical difference in the dosage (P = .97) and duration (P = .69) between the 2 groups. Area under the curve values for the oral corticosteroid dosages and duration were 0.482 and 0.549, respectively. CONCLUSION: This study revealed that neither dosage nor duration of concurrent oral corticosteroid use was predictive of postoperative complications after TJA. American Society of Anesthesiologist Physical Status 3 is a major factor in postoperative complications after TJA.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Adrenal Cortex Hormones/adverse effects , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Knee/adverse effects , Humans , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Retrospective Studies , Risk Factors , Surgical Wound Infection/complications , Surgical Wound Infection/etiology
11.
Arch Orthop Trauma Surg ; 141(12): 2267-2276, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34652514

ABSTRACT

PURPOSE: It remains to be established whether optical computed tomography (CT)-free and acceleration-based navigation systems differ in terms of implantation accuracy and clinical outcomes for total knee arthroplasty. This randomised prospective study compared the implantation accuracy of these two navigation systems in total knee arthroplasty. METHODS: Optical CT-free navigation (ExactechGPS) or acceleration-based navigation (KneeAlign2) was randomly assigned to the left or right knee of 45 patients who underwent a single-stage bilateral total knee arthroplasty: the ExactechGPS (n = 45) and KneeAlign2 groups (n = 45) were compared. Component alignments were evaluated using three-dimensional computed tomography and radiography at pre- and post-surgery. Implantation accuracy of the component alignment, proportion of outliers, postoperative range of motion, and Japanese Orthopaedic Association (JOA) score were compared between the systems. RESULTS: The implantation accuracies of the lower-extremity mechanical alignment, coronal femoral component angle, coronal tibial component angle, sagittal femoral component, axial femoral angle, and axial tibial angle had no significant difference between the groups. The implantation accuracy of the sagittal tibial component angle was superior in the ExactechGPS than the KneeAlign2 group (1.3° vs. 1.8°, P = 0.034). The proportions of outliers, range of motion, and JOA score had no significant difference between the groups. CONCLUSION: In the tibial sagittal plane, there was a significant difference in the implantation accuracy, but its difference did not affect the clinical outcomes. Both navigation systems have clinically acceptable implantation accuracy.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Surgery, Computer-Assisted , Femur/diagnostic imaging , Femur/surgery , Humans , Knee Joint/surgery , Osteoarthritis, Knee/surgery , Prospective Studies , Tibia/diagnostic imaging , Tibia/surgery
12.
Mod Rheumatol ; 31(6): 1215-1220, 2021 Nov.
Article in English | MEDLINE | ID: mdl-33428492

ABSTRACT

OBJECTIVES: This study aimed to investigate the effect of diabetes mellitus (DM) on knee extension/flexion angle and its early clinical course after total knee arthroplasty (TKA). METHODS: Patients who received TKA were retrospectively divided into two groups based on haemoglobinA1c level; the DM group (23 knees) and the control group (23 knees matched for baseline characteristics). The passive knee extension/flexion angle, gait speed and Japanese Orthopaedic Association (JOA) score were evaluated preoperatively and at 1, 6 and 12 months postoperatively. RESULTS: There was no significant difference in the passive knee flexion angle at 1 and 6 months postoperatively between the groups (p = .302, p = .160, respectively). The passive knee flexion angle was significantly lower at 12 months postoperatively in the DM group than the control group (p = .014). In the DM group, the passive knee flexion angle at 6 and 12 months significantly decreased compared with that at 1 month postoperatively (p = .021, p < .001, respectively). There were no significant differences in the knee extension angle, gait speed and JOA score between the groups. CONCLUSION: Patients with DM are likely to experience passive knee flexion angle exacerbating from 1 to 6 months after TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Diabetes Mellitus , Osteoarthritis, Knee , Humans , Knee Joint/diagnostic imaging , Knee Joint/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/surgery , Range of Motion, Articular , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL