1.
J Clin Monit Comput ; 37(1): 147-154, 2023 02.
Article in English | MEDLINE | ID: mdl-35661319

ABSTRACT

PURPOSE: The Patient State Index (PSI) is a newly introduced electroencephalogram-based tool for objective and continuous monitoring of sedation levels of patients under general anesthesia. This study investigated the potential correlation between the PSI and the Richmond Agitation‒Sedation Scale (RASS) score in intensive care unit (ICU) patients and established the utility of the PSI in assessing sedation levels. METHODS: In this prospective observational study, PSI values were continuously monitored via SedLine® (Masimo, Irvine, CA, USA); the RASS score was recorded every 2 h for patients on mechanical ventilation. Physicians and nurses were blinded to the PSI values. Overall, 382 PSI and RASS score sets were recorded for 50 patients. RESULTS: The PSI score correlated positively with RASS scores, and Spearman's rank correlation coefficient between the PSI and RASS was 0.79 (95% confidence interval [CI]: 0.75‒0.83). The PSI showed statistically significant difference among the RASS scores (Kruskal‒Wallis chi-square test: 242, df = 6, P < 2.2-e16). The PSI threshold for distinguishing light (RASS score ≥ - 2) sedation from deep sedation (RASS score ≤ - 3) was 54 (95% CI: 50-65; area under the curve, 0.92 [95% CI: 0.89‒0.95]; sensitivity, 0.91 [95% CI: 0.86‒0.95]; specificity, 0.81 [95% CI: 0.77-0.86]). CONCLUSIONS: The PSI correlated positively with RASS scores, which represented a widely used tool for assessing sedation levels, and the values were significantly different among RASS scores. Additionally, the PSI had a high sensitivity and specificity for distinguishing light from deep sedation. The PSI could be useful for assessing sedation levels in ICU patients. University Hospital Medical Information Network (UMIN000035199, December 10, 2018).


Subject(s)
Critical Illness , Hypnotics and Sedatives , Humans , Critical Care , Pain , Anesthesia, General , Respiration, Artificial , Intensive Care Units
2.
J Med Case Rep ; 16(1): 61, 2022 Feb 14.
Article in English | MEDLINE | ID: mdl-35152911

ABSTRACT

BACKGROUND: Nivolumab is an immune checkpoint inhibitor that blocks inhibitors of T-cell activation and blunts antitumor immunity and is used in the treatment of various cancers. However, immune checkpoint inhibitors have immune-related adverse effects on various organs due to promoting T-cell activity against host tissues by blocking inhibition of T-cell function. Although immune-related adverse effects including hepatitis, colitis, pneumonitis, dermatitis, nephritis, endocrinopathies, and hypophysitis are well recognized with established treatment guidelines, neuromuscular immune-related adverse effects are rare phenomena. CASE PRESENTATION: A 55-year-old Asian (Japanese) woman was diagnosed with nivolumab-related myasthenia gravis with myositis and myocarditis. She had a past history of thymectomy for large thymoma with a high anti-acetylcholine receptor antibody level without any symptoms. Nivolumab was administered for the treatment of malignant melanoma. Creatine kinase levels began to rise 2 weeks after the administration, and abnormal neurological findings appeared 3 weeks after the administration. Ventricular arrhythmia, wide QRS complex, and dyssynchrony of the left ventricle also appeared. Intravenous immunoglobulin and corticosteroids were administered, and plasma exchange was performed. The patient required intensive care and prolonged mechanical ventilation with tracheostomy owing to weakness of the diaphragm; she was eventually weaned from the ventilator and discharged. Diaphragm ultrasound was used for the decision-making of the weaning strategy and evaluation of the diaphragmatic function. CONCLUSIONS: Nivolumab-induced severe myasthenia gravis with myositis and myocarditis required intensive care and prolonged mechanical ventilation. Although immune checkpoint inhibitor-related myasthenia gravis is a rare adverse event, appropriate and prompt treatment is required because of its severity and rapid progression. Diaphragm ultrasound was useful not only in diagnosing diaphragm dysfunction and deciding the strategy for weaning from mechanical ventilation but also in evaluating the recovery of the diaphragmatic function.


Subject(s)
Myasthenia Gravis , Myositis , Thymoma , Thymus Neoplasms , Female , Humans , Middle Aged , Myasthenia Gravis/therapy , Myositis/chemically induced , Myositis/therapy , Nivolumab/adverse effects , Respiration, Artificial , Thymoma/drug therapy
3.
Heart Vessels ; 37(4): 691-696, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34618188

ABSTRACT

Central venous catheters (CVCs) and pulmonary artery catheters (PACs) are widely used in intensive care and perioperative management. The detection and prevention of catheter-related thrombosis (CRT) are important because CRT is a complication of catheter use and can cause pulmonary embolism and bloodstream infection. Currently, there is no evidence for CRT in patients using both CVC and PAC. We conducted a single-center, prospective, observational study to identify the incidence, timing, and risk factors for CRT in patients undergoing cardiovascular surgery and using a combination of CVC and PAC through the right internal jugular vein (RIJV). Out of 50 patients, CRT was observed using ultrasonography in 39 patients (78%), and the median time of CRT formation was 1 day (interquartile range: 1-1.5) after catheter insertion. The mean duration of PAC placement was 3 days (interquartile range: 2-5), and the maximum diameter of CRT was 12 mm (interquartile range: 10-15). In short-axis images, CRT occupied more than half of the cross-sectional area of the RIJV in five patients (10%), and CRT completely occluded the RIJV in one patient (2%). Platelet count, duration of PAC placement, and intraoperative bleeding amount were found to be high-risk indicators of CRT. In conclusion, patients who underwent cardiovascular surgery and using both CVC and PAC had a high incidence of CRT. Avoiding unnecessary PAC placement and early removal of catheters in patients at high risk of developing CRT may prevent the development of CRT.


Subject(s)
Cardiac Surgical Procedures , Catheterization, Central Venous , Central Venous Catheters , Thrombosis , Cardiac Surgical Procedures/adverse effects , Catheterization, Central Venous/adverse effects , Central Venous Catheters/adverse effects , Humans , Jugular Veins/diagnostic imaging , Prospective Studies , Pulmonary Artery/diagnostic imaging , Thrombosis/etiology