Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 30(3): 286-95, 2014 May.
Article in English | MEDLINE | ID: mdl-24011672

ABSTRACT

In this study the generalized Modulation Transfer Function (GMTF) and the geometric sharpness (Sgeo) were used (i) to study the effects of various focal spot sizes (0.04 mm-0.3 mm), x-ray intensity distributions (Gaussian and double Gaussian), breast thicknesses (2-7 cm) and magnifications M (1.0-2.0) on the spatial resolution of an a-Se digital mammography system, (ii) to identify suitable focal spots for magnification mammography and (iii) derive optimum magnifications. For the calculation of GMTF the required components were: focal spot MTF, obtained from theory, detector MTF, scatter MTF and scatter fraction obtained from Monte Carlo simulations. The results showed that focal spots with sizes up to 0.18 mm are suitable for magnification mammography offering a GMTF which is >50% and >20% at the respective object frequencies of 6.5 mm(-1) and 9 mm(-1). Focal spots with sizes < 0.16 mm and Gaussian. intensity distribution, or sizes ≤ 0.1 mm and double Gaussian, offer a system resolution which improves or does not deteriorate with magnification for most object frequencies. For larger focal spots, i.e. 0.16-0.18 mm for a Gaussian and 0.12-0.18 mm for a double Gaussian. intensity distribution, optimum magnifications exist which depend on the object frequency and breast thickness. System resolution (in terms of Sgeo) is maximized at M = 1.8-2.0 (all breast thicknesses) for Gaussian intensity distribution, and at M = 1.4-1.6 (breast thicknesses ≤ 4 cm) and M = 1.6-1.8 (thicker breasts) for double Gaussian.


Subject(s)
Breast/cytology , Mammography/methods , Monte Carlo Method , Radiographic Image Enhancement/methods , Humans
2.
Phys Med Biol ; 52(21): 6439-60, 2007 Nov 07.
Article in English | MEDLINE | ID: mdl-17951854

ABSTRACT

Materials such as a-Se, a-As(2)Se(3), GaSe, GaAs, Ge, CdTe, CdZnTe, Cd(0.8)Zn(0.2)Te, ZnTe, PbO, TlBr, PbI(2) and HgI(2) are potential candidates as photoconductors in direct detectors for digital mammography. The x-ray induced primary electrons inside a photoconductor's bulk comprise the initial signal that propagates and forms the final signal (image) on the detector's electrodes. An already developed model for a-Se has been properly extended to simulate the primary electron production in the materials mentioned. Primary electron characteristics, such as their energy, angular and spatial distributions that strongly influence the characteristics of the final image, were studied for both monoenergetic and polyenergetic x-ray spectra in the mammographic energy range. The characteristic feature in the electron energy distributions for PbI(2) and HgI(2) is the atomic deexcitation peaks, whereas for the rest of the materials their shape can also be influenced by the electrons produced from primary photons. The electrons have a small tendency to be forward ejected whereas they prefer to be ejected perpendicular (theta = pi/2) to the incident beam's axis and at two lobes around phi = 0 and phi = pi. At practical mammographic energies (15-40 keV) a-Se, a-As(2)Se(3) and Ge have the minimum azimuthal uniformity whereas CdZnTe, Cd(0.8)Zn(0.2)Te and CdTe the maximum one. The spatial distributions for a-Se, a-As(2)Se(3), GaSe, GaAs, Ge, PbO and TlBr are almost independent of the polyenergetic spectrum, while those for CdTe, CdZnTe, Cd(0.8)Zn(0.2)Te, ZnTe, PbI(2) and HgI(2) have a spectrum dependence. In the practical mammographic energy range and at this primitive stage of primary electron production, a-Se has the best inherent spatial resolution as compared to the rest of the photoconductors. PbO has the minimum bulk space in which electrons can be produced whereas CdTe has the maximum one.


Subject(s)
Mammography/instrumentation , Mammography/methods , Computer Simulation , Electrons , Humans , Light , Models, Statistical , Monte Carlo Method , Phantoms, Imaging , Photons , Probability , Radiographic Image Enhancement , Reproducibility of Results , Scattering, Radiation , X-Rays
3.
Phys Med Biol ; 50(16): 3717-38, 2005 Aug 21.
Article in English | MEDLINE | ID: mdl-16077223

ABSTRACT

Selenium is among the materials under investigation that may form effective detectors and provide a major contribution to digital mammography. Till the final image formation, there is an intervention of the x-ray photons transformation to primary electrons and their subsequent ionizing drift towards the electrodes that collect them. The characteristics of the generated primary electrons inside a-Se material such as their angular, spatial and energy distribution affect the characteristics of the final image. A Monte Carlo based model has been developed that simulates the x-ray irradiation of an a-Se detector plate, including primary photon interactions (photoelectric absorption, coherent and incoherent scattering), as well as secondary ones, such as fluorescence (Kalpha, Kbeta) and emission of Auger electrons. The angular, spatial and energy distributions for the generated primary electrons inside a-Se have been produced for various mammographic x-ray spectra and their usefulness in designing and optimizing a detector made of a-Se for digital mammography is discussed.


Subject(s)
Mammography/instrumentation , Mammography/methods , Selenium/chemistry , Algorithms , Electrons , Humans , Monte Carlo Method , Phantoms, Imaging , Photons , Radiation , Radiographic Image Enhancement , Scattering, Radiation , Spectrometry, X-Ray Emission , Spectrophotometry , X-Ray Intensifying Screens , X-Rays
SELECTION OF CITATIONS
SEARCH DETAIL
...