Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Environ Sci Technol ; 48(17): 10264-72, 2014 Sep 02.
Article in English | MEDLINE | ID: mdl-25032949

ABSTRACT

To analyze the naphthenic acid content of environmental waters quickly and efficiently, we have developed a method that employs differential mobility spectrometry (DMS) coupled to mass spectrometry (MS). This technique combines the benefits of infusion-based MS experiments (parallel, on-demand access to individual components) with DMS's ability to provide liquid chromatography-like separations of isobaric and isomeric compounds in a fraction of the time. In this study, we have applied a DMS-MS workflow to the rapid gas-phase separation of naphthenic acids (NAs) within a technical standard and a real-world oil sands process-affected water (OSPW) extract. Among the findings provided by this workflow are the rapid characterization of isomeric NAs (i.e., same molecular formulas) in a complex OSPW sample, the ability to use DMS to isolate individual NA components (including isomeric NAs) for in-depth structural analyses, and a method by which NA analytes, background ions, and dimer species can be characterized by their distinct behaviors in DMS. Overall, the profiles of the NA content of the technical and OSPW samples were consistent with published values for similar samples, such that the benefits of DMS technology do not detract from the workflow's accuracy or quality.


Subject(s)
Carboxylic Acids/chemistry , Mass Spectrometry/methods , Spectrum Analysis/methods , Complex Mixtures/chemistry , Dimerization , Ions , Isomerism , Oils/chemistry , Reference Standards , Silicon Dioxide , Wastewater/chemistry , Water Pollutants, Chemical/analysis
2.
Anal Chem ; 84(13): 5677-84, 2012 Jul 03.
Article in English | MEDLINE | ID: mdl-22686274

ABSTRACT

Modern determination techniques for pesticides must yield identification quickly with high confidence for timely enforcement of tolerances. A protocol for the collection of liquid chromatography (LC) electrospray ionization (ESI)-quadruple linear ion trap (Q-LIT) mass spectrometry (MS) library spectra was developed. Following the protocol, an enhanced product ion (EPI) library of 240 pesticides was developed by use of spectra collected from two laboratories. A LC-Q-LIT-MS workflow using scheduled multiple reaction monitoring (sMRM) survey scan, information-dependent acquisition (IDA) triggered collection of EPI spectra, and library search was developed and tested to identify the 240 target pesticides in one single LC-Q-LIT MS analysis. By use of LC retention time, one sMRM survey scan transition, and a library search, 75-87% of the 240 pesticides were identified in a single LC/MS analysis at fortified concentrations of 10 ng/g in 18 different foods. A conventional approach with LC-MS/MS using two MRM transitions produced the same identifications and comparable quantitative results with the same incurred foods as the LC-Q-LIT using EPI library search, finding 1.2-49 ng/g of either carbaryl, carbendazim, fenbuconazole, propiconazole, or pyridaben in peaches; carbendazim, imazalil, terbutryn, and thiabendazole in oranges; terbutryn in salmon; and azoxystrobin in ginseng. Incurred broccoli, cabbage, and kale were screened with the same EPI library using three LC-Q-LIT and a LC-quadruple time-of-flight (Q-TOF) instruments. The library search identified azoxystrobin, cyprodinil, fludioxinil, imidacloprid, metalaxyl, spinosyn A, D, and J, amd spirotetramat with each instrument. The approach has a broad application in LC-MS/MS type targeted screening in food analysis.


Subject(s)
Food Analysis/methods , Pesticides/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Tandem Mass Spectrometry/methods , Chromatography, Liquid , Databases, Factual , Ions/analysis
3.
Bioanalysis ; 2(3): 407-19, 2010 Mar.
Article in English | MEDLINE | ID: mdl-21083251

ABSTRACT

BACKGROUND: The objective of this study was to evaluate the sensitivity requirement for LC-MS/MS as an analytical tool to characterize metabolites in plasma and urine at microdoses in rats and to investigate proportionality of metabolite exposure from a microdose of 1.67 µg/kg to a high dose of 5000 µg/kg for atorvastatin, ofloxacin, omeprazole and tamoxifen. RESULTS: Only the glucuronide metabolite of ofloxacin, the hydroxylation metabolite of omeprazole and the hydration metabolite of tamoxifen were characterized in rat plasma at microdose by LC-MS/MS. The exposure of detected metabolites of omeprazole and tamoxifen appeared to increase in a nonproportional manner with increasing doses. Exposure of ortho- and para-hydroxyatorvastatin, but not atorvastatin and lactone, increased proportionally with increasing doses. CONCLUSION: LC-MS/MS has demonstrated its usefulness for detecting and characterizing the major metabolites in plasma and urine at microdosing levels in rats. The exposure of metabolites at microdose could not simply be used to predict their exposure at higher doses.


Subject(s)
Chromatography, Liquid/methods , Metabolome/drug effects , Tandem Mass Spectrometry/methods , Animals , Atorvastatin , Dose-Response Relationship, Drug , Heptanoic Acids/administration & dosage , Heptanoic Acids/metabolism , Heptanoic Acids/pharmacokinetics , Heptanoic Acids/pharmacology , Male , Ofloxacin/administration & dosage , Ofloxacin/metabolism , Ofloxacin/pharmacokinetics , Ofloxacin/pharmacology , Omeprazole/administration & dosage , Omeprazole/metabolism , Omeprazole/pharmacokinetics , Omeprazole/pharmacology , Pharmacokinetics , Pyrroles/administration & dosage , Pyrroles/metabolism , Pyrroles/pharmacokinetics , Pyrroles/pharmacology , Rats , Rats, Sprague-Dawley , Tamoxifen/administration & dosage , Tamoxifen/metabolism , Tamoxifen/pharmacokinetics , Tamoxifen/pharmacology
4.
Pharm Res ; 25(7): 1572-82, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18299965

ABSTRACT

PURPOSE: To evaluate the sensitivity requirement for LC-MS/MS as an analytical tool to support human microdosing study with sub-pharmacological dose, investigate proportionality of pharmacokinetics from the microdose to therapeutic human equivalent doses in rats and characterize circulating metabolites in rats administered with the microdose. MATERIALS AND METHODS: Five drugs of antipyrine, metoprolol, carbamazepine, digoxin and atenolol were administered orally to male Sprague-Dawley rats at 0.167, 1.67, 16.7, 167 and 1,670 microg/kg doses. Plasma samples were extracted using either solid phase extraction or liquid-liquid extraction, and analyzed using LC-MS/MS. RESULTS: Using 100 microl of plasma sample, the lower limit of quantitation for antipyrine (10 pg/ml), carbamazepine (1 pg/ml), metoprolol (5 pg/ml), atenolol (20 pg/ml), and digoxin (5 pg/ml) were achieved using an API 5000. Proportional pharmacokinetics were observed from 0.167 microg/kg to 1,670 microg/kg for antipyrine and carbamazepine and from 1.67 to 1,670 microg/kg for atenolol and digoxin, while metoprolol exhibited a non-proportional pharmacokinetics relationship. Several metabolites of carbamazepine were characterized in plasma from rats dosed at 1.67 mug/kg using LC-MS/MS. CONCLUSIONS: This study has shown the promise of sensitive LC-MS/MS method to support microdose pharmacokinetics and drug metabolism studies in human.


Subject(s)
Pharmaceutical Preparations/metabolism , Pharmacokinetics , ATP Binding Cassette Transporter, Subfamily B, Member 1/metabolism , Animals , Biological Availability , Biopharmaceutics , Calibration , Chemical Phenomena , Chemistry, Physical , Chromatography, Liquid , In Vitro Techniques , Indicators and Reagents , Male , Microsomes, Liver/metabolism , NADP/metabolism , Quality Control , Rats , Rats, Sprague-Dawley , Reference Standards , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry
5.
Anal Chim Acta ; 567(1): 39-47, 2006 May 10.
Article in English | MEDLINE | ID: mdl-17723377

ABSTRACT

A new IC-ESI-MS/MS method, with simple sample preparation procedure, has been developed for quantification and confirmation of perchlorate (ClO4-) anions in water, fresh and canned food, wine and beer samples at low part-per-trillion (ng l(-1)) levels. To the best of our knowledge, this is the first time an analytical method is used for determination of perchlorate in wine and beer samples. The IC-ESI-MS/MS instrumentation consisted of an ICS-2500 ion chromatography (IC) system coupled to either an API 2000 or an API 3200 mass spectrometer. The IC-ESI-MS/MS system was optimized to monitor two pairs of precursor and fragment ion transitions, i.e., multiple reaction monitoring (MRM). All samples had oxygen-18 isotope labeled perchlorate internal standard (ISTD) added prior to extraction. Chlorine isotope ratio (35Cl/37Cl) was used as a confirmation tool. The transition of 35Cl16O4- (m/z 98.9) into 35Cl16O3- (m/z 82.9) was monitored for quantifying the main analyte; the transition of 37Cl16O4- (m/z 100.9) into 37Cl16O3- (m/z 84.9) was monitored for examining a proper isotopic abundance ratio of 35Cl/37Cl; and the transition of 35Cl18O4- (m/z 107.0) into 35Cl18O3- (m/z 89.0) was monitored for quantifying the internal standard. The minimum detection limit (MDL) for this method in de-ionized water is 5 ng l(-1) (ppt) using the API 2000 mass spectrometer and 0.5 ng l(-1) using the API 3200 mass spectrometer. Over 350 food and beverage samples were analyzed mostly in triplicate. Except for four, all samples were found to contain measurable amounts of perchlorate. The levels found ranged from 5 ng l(-1) to 463.5+/-6.36 microg kg(-1) using MRM 98.9-->82.9 and 100 microl injection.

6.
J Mass Spectrom ; 40(8): 1017-29, 2005 Aug.
Article in English | MEDLINE | ID: mdl-15934027

ABSTRACT

The use of a hybrid triple quadrupole-linear ion trap (QqQ(LIT)) mass spectrometer system for a comprehensive study of fragmentation mechanisms is described. The anxiolytic drug, buspirone, was chosen as a model compound for this study. With the advent of a QqQ(LIT) instrument, both the traditional quadrupole and the new linear ion trap scans (LIT) could be performed in a single LC run. In the past, a sample had to be run on two different instruments, namely, a triple quadrupole instrument (QqQ) and a 3D ion trap (3D IT) to obtain similar information. With the new QqQ(LIT) technology, collision-induced dissociation (CID) occur in a quadrupole collision cell, q2, and fragment ions are trapped and analyzed in Q3 operated in LIT mode. In this work, high-sensitivity product ion spectra of buspirone were obtained from the one-stage 'Enhanced Product Ion' scan (EPI) with rich product ions and no low mass cut-off. Furthermore, detailed fragmentation pathways were elucidated by further dissociation of each of the fragment ions in the EPI spectrum using MS(3) mode in the same run. The MS(3) scan was performed by incorporating CID in q2, and trapping, cooling, isolation, and resonance-excitation in Q3 when operating in LIT mode. This approach allowed unambiguous assignment of all fragment ions quickly with fewer experiments and easier interpretation than the previous approach. The overall sensitivity for obtaining complete fragment ion data was significantly improved for QqQ(LIT) as compared with that of QqQ and 3D IT mass spectrometers. This is beneficial for structure determination of unknown trace components. The method allowed structure determination of metabolites of buspirone in rat microsomes at 1 microM concentration, which was a 10-fold lower concentration than was needed for QqQ or 3D IT instruments. The QqQ(LIT) instrument provided a simple, rapid, sensitive and powerful approach for structure elucidation of trace components.


Subject(s)
Buspirone/chemistry , Buspirone/metabolism , Animals , Buspirone/analogs & derivatives , Buspirone/analysis , Mass Spectrometry/methods , Molecular Structure , Rats
SELECTION OF CITATIONS
SEARCH DETAIL
...