Introduction: This review explores the Starling-like physiological control method (SLC) for rotary ventricular assist devices (VADs) for severe heart failure. The SLC, based on mathematical models of the circulation, has two functions modeling each ventricle. The first function controls the output of the VAD to the arterial pool according to Starling's law, while the second function accounts for how the blood returns to the heart from the veins. The article aims to expose clinicians to SLC in an accessible and clinically relevant discussion. Areas Covered: The article explores the physiology underlying the controller, its development and how that physiology can be adapted to SLC. Examples of controller performance are demonstrated and discussed using a benchtop model of the cardiovascular system. A discussion of the limitations and criticisms of SLC is presented, followed by a future outlook on the clinical adoption of SLC. Expert Opinion: Due to its simplicity and emulation of the natural cardiac autoregulation, SLC is the superior physiological control method for rotary VADs. However, current technical and regulatory challenges prevent the clinical translation of SLC of VADs. Further technical and regulatory development will enable the clinical translation of SLCs of VADs in the coming years.


Subject(s)
Heart Ventricles/physiopathology , Heart-Assist Devices , Blood Pressure , Coronary Circulation/physiology , Humans , Models, Cardiovascular
2.
Artif Organs ; 43(11): E294-E307, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31188476

ABSTRACT

Rotary ventricular assist devices (VADs) operated clinically under constant speed control (CSC) cannot respond adequately to changes in patient cardiac demand, resulting in sub-optimal VAD flow regulation. Starling-like control (SLC) of VADs mimics the healthy ventricular flow regulation and automatically adjusts VAD speed to meet varying patient cardiac demand. The use of a fixed control line (CL - the relationship between ventricular preload and VAD flow) limits the flow regulating capability of the controller, especially in the case of exercise. Adaptive SLC (ASLC) overcomes this limitation by allowing the controller to adapt the CL to meet a diverse range of circulatory conditions. This study evaluated ASLC, SLC and CSC in a biventricular supported mock circulation loop under the simulated conditions of exercise, sleep, fluid loading and systemic hypertension. Each controller was evaluated on its ability to remain within predefined limits of VAD flow, preload, and afterload. The ASLC produced superior cardiac output (CO) during exercise (10.1 L/min) compared to SLC (7.3 L/min) and CSC (6.3 L/min). The ASLC produced favourable haemodynamics during sleep, fluid loading and systemic hypertension and could remain within a predefined haemodynamic range in three out of four simulations, suggesting improved haemodynamic performance over SLC and CSC.


Subject(s)
Heart-Assist Devices , Hemodynamics , Cardiac Output , Computer Simulation , Exercise , Humans , Models, Cardiovascular , Sleep
3.
Artif Organs ; 43(9): 860-869, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30868602

ABSTRACT

The high cost of ventricular assist devices results in poor cost-effectiveness when used as a short-term bridging solution, thus a low-cost alternative is desirable. The present study aimed to develop an intraventricular balloon pump (IVBP) for short-term circulatory support, and to evaluate the effect of balloon actuation timing on the degree of cardiac support provided to a simulated in vitro severe heart failure (SHF) patient. A silicone IVBP was designed to avoid contact with internal left ventricular (LV) features (ie, papillary muscles, chordae, aortic, and mitral valves) based on LV computed tomography data of 10 SHF patients with dilated cardiomyopathy. The hemodynamic effects of varying balloon inflation and deflation timing parameters (inflation duty [D] and end-inflation point [σ]) were evaluated in a purpose-built systemic mock circulatory loop. Three IVBP actuation timing categories were defined: co-, transitional, and counterpulsation. Compared to the SHF baseline, co-pulsation increased aortic flow from 3.5 to 5.2 L/min, mean arterial pressure from 72.1 to 94.8 mmHg and ejection fraction from 14.4% to 21.5%, while mean left atrial pressure decreased from 14.6 to 10 mmHg. Transitional and counterpulsation resulted in a double ventricular pulse and extended the duration of increased ventricular pressure, potentially impeding diastolic filling and coronary perfusion. This in vitro study showed the IVBP could restore the hemodynamic balance of a simulated SHF patient with dilated cardiomyopathy to healthy levels.


Subject(s)
Heart Failure/therapy , Intra-Aortic Balloon Pumping/instrumentation , Equipment Design , Heart Failure/physiopathology , Heart-Assist Devices , Hemodynamics , Humans
4.
Artif Organs ; 43(3): E16-E27, 2019 Mar.
Article in English | MEDLINE | ID: mdl-30094842

ABSTRACT

Rotary ventricular assist devices (VADs) are less sensitive to preload than the healthy heart, resulting in inadequate flow regulation in response to changes in patient cardiac demand. Starling-like physiological controllers (SLCs) have been developed to automatically regulate VAD flow based on ventricular preload. An SLC consists of a cardiac response curve (CRC) which imposes a nonlinear relationship between VAD flow and ventricular preload, and a venous return line (VRL) which determines the return path of the controller. This study investigates the importance of a physiological VRL in SLC of dual rotary blood pumps for biventricular support. Two experiments were conducted on a physical mock circulation loop (MCL); the first compared an SLC with an angled physiological VRL (SLC-P) against an SLC with a vertical VRL (SLC-V). The second experiment quantified the benefit of a dynamic VRL, represented by a series of specific VRLs, which could adapt to different circulatory states including changes in pulmonary (PVR) and systemic (SVR) vascular resistance versus a fixed physiological VRL which was calculated at rest. In both sets of experiments, the transient controller responses were evaluated through reductions in preload caused by the removal of fluid from the MCL. The SLC-P produced no overshoot or oscillations following step changes in preload, whereas SLC-V produced 0.4 L/min (12.5%) overshoot for both left and right VADs. Additionally, the SLC-V had increased settling time and reduced controller stability as evidenced by transient controller oscillations. The transient results comparing the specific and standard VRLs demonstrated that specific VRL rise times were improved by between 1.2 and 4.7 s ( x ¯ = 3.05 s), while specific VRL settling times were improved by between 2.8 and 16.1 seconds ( x ¯ = 8.38 s) over the standard VRL. This suggests only a minor improvement in controller response time from a dynamic VRL compared to the fixed VRL. These results indicate that the use of a fixed physiologically representative VRL is adequate over a wide variety of physiological conditions.


Subject(s)
Blood Circulation/physiology , Equipment Design , Heart-Assist Devices , Cardiac Output/physiology , Computer Simulation , Humans , Time Factors , Veins/physiology
5.
Article in English | MEDLINE | ID: mdl-30440278

ABSTRACT

Rotary blood pumps may be used as ventricular assist devices (VADs) to support patients with end-stage heart failure-'rotary VADs'. Clinically, rotary VADs are operated at a constant speed which is set manually. Due to inadequate haemodynamic monitoring equipment outside of the hospital setting, device speed remains the same for weeks or months at a time, leaving clinicians in the dark, and patients vulnerable to harmful over- or under-pumping events. Therefore, it would be beneficial to have an implantable sensor which can measure blood pressure at the rotary VAD inlet or outlet and detect the onset of adverse events. In this study, a temperature compensated fibre Bragg grating (FBG) based strain sensor which can be incorporated into a VAD and used for continuous, real-time blood pressure monitoring is investigated. Error in the pressure reading between the developed and reference sensor occurred due to changes in temperature. A generalised linear model was used to compensate for temperature related error between 35-39º. Without temperature compensation, the mean error in the pressure reading over the desired range of -25 to 150 mmHg was approximately ±5 mmHg. The temperature compensated mean error over the same range was less than ±2 mmHg. The compensation technique was effective over a wide range of temperatures and pressures, demonstrating the potential of the sensor for continuous real-time blood pressure monitoring.


Subject(s)
Heart-Assist Devices , Blood Pressure , Heart Failure/physiopathology , Hemodynamics , Humans , Monitoring, Physiologic , Temperature
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2017: 1291-1294, 2017 Jul.
Article in English | MEDLINE | ID: mdl-29060112

ABSTRACT

Control for dual rotary left ventricular assist devices (LVADs) used as a biventricular assist device (BiVAD) is challenging. If the control system fails, flow imbalance between the systemic and the pulmonary circulations would result, subsequently leading to ventricular suction or pulmonary congestion. With the expectation that advanced control approaches such as model predictive control could address the challenges naturally and effectively, we developed a synergistic first principles model predictive controller (MPC) for the BiVAD. The internal model of the MPC is a simplified state-space model that has been developed and validated in a previous study. A single Frank-Starling (FS) control curve was used to define the target pump flow corresponding to the preload on each side of the heart. The MPC was evaluated in a validated numerical model using three clinical scenarios: blood loss, myocardial recovery, and exercise. Simulation results showed that the MPC was effective in adapting to changes in physiological states without causing ventricular suction or pulmonary congestion. The use of MPC for a BiVAD eliminates the need for two controllers of dual LVADs thus making the task of controller tuning easier.


Subject(s)
Heart-Assist Devices , Computer Simulation , Heart Ventricles , Models, Cardiovascular , Pulmonary Circulation
7.
Artif Organs ; 41(10): 911-922, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28741664

ABSTRACT

Rotary ventricular assist devices (VADs) are used to provide mechanical circulatory support. However, their lack of preload sensitivity in constant speed control mode (CSC) may result in ventricular suction or venous congestion. This is particularly true of biventricular support, where the native flow-balancing Starling response of both ventricles is diminished. It is possible to model the Starling response of the ventricles using cardiac output and venous return curves. With this model, we can create a Starling-like physiological controller (SLC) for VADs which can automatically balance cardiac output in the presence of perturbations to the circulation. The comparison between CSC and SLC of dual HeartWare HVADs using a mock circulation loop to simulate biventricular heart failure has been reported. Four changes in cardiovascular state were simulated to test the controller, including a 700 mL reduction in circulating fluid volume, a total loss of left and right ventricular contractility, reduction in systemic vascular resistance ( SVR) from 1300 to 600 dyne  s/cm5, and an elevation in pulmonary vascular resistance ( PVR) from 100 to 300 dyne  s/cm5. SLC maintained the left and right ventricular volumes between 69-214 mL and 29-182 mL, respectively, for all tests, preventing ventricular suction (ventricular volume = 0 mL) and venous congestion (atrial pressures > 20 mm Hg). Cardiac output was maintained at sufficient levels by the SLC, with systemic and pulmonary flow rates maintained above 3.14 L/min for all tests. With the CSC, left ventricular suction occurred during reductions in SVR, elevations in PVR, and reduction in circulating fluid simulations. These results demonstrate a need for a physiological control system and provide adequate in vitro validation of the immediate response of a SLC for biventricular support.


Subject(s)
Computer Simulation , Heart-Assist Devices , Hemodynamics , Models, Cardiovascular , Blood Volume , Cardiac Output , Heart Failure/physiopathology , Heart Failure/therapy , Heart Ventricles/physiopathology , Heart-Assist Devices/adverse effects , Humans , Prosthesis Design , Vascular Resistance
8.
PLoS One ; 12(2): e0172393, 2017.
Article in English | MEDLINE | ID: mdl-28212401

ABSTRACT

Due to a shortage of donor hearts, rotary left ventricular assist devices (LVADs) are used to provide mechanical circulatory support. To address the preload insensitivity of the constant speed controller (CSC) used in conventional LVADs, we developed a preload-based Starling-like controller (SLC). The SLC emulates the Starling law of the heart to maintain mean pump flow ([Formula: see text]) with respect to mean left ventricular end diastolic pressure (PLVEDm) as the feedback signal. The SLC and CSC were compared using a mock circulation loop to assess their capacity to increase cardiac output during mild exercise while avoiding ventricular suction (marked by a negative PLVEDm) and maintaining circulatory stability during blood loss and severe reductions in left ventricular contractility (LVC). The root mean squared hemodynamic deviation (RMSHD) metric was used to assess the clinical acceptability of each controller based on pre-defined hemodynamic limits. We also compared the in-silico results from our previously published paper with our in-vitro outcomes. In the exercise simulation, the SLC increased [Formula: see text] by 37%, compared to only 17% with the CSC. During blood loss, the SLC maintained a better safety margin against left ventricular suction with PLVEDm of 2.7 mmHg compared to -0.1 mmHg for CSC. A transition to reduced LVC resulted in decreased mean arterial pressure (MAP) and [Formula: see text] with CSC, whilst the SLC maintained MAP and [Formula: see text]. The results were associated with a much lower RMSHD value with SLC (70.3%) compared to CSC (225.5%), demonstrating improved capacity of the SLC to compensate for the varying cardiac demand during profound circulatory changes. In-vitro and in-silico results demonstrated similar trends to the simulated changes in patient state however the magnitude of hemodynamic changes were different, thus justifying the progression to in-vitro evaluation.


Subject(s)
Heart-Assist Devices , Ventricular Function, Left/physiology , Cardiac Output , Computer Simulation , Equipment Design , Exercise , Hemodynamics , Humans
9.
J Heart Lung Transplant ; 35(11): 1358-1364, 2016 11.
Article in English | MEDLINE | ID: mdl-27311376

ABSTRACT

BACKGROUND: Donation after circulatory death (DCD) represents a potential new source of hearts to increase the donor pool. We showed previously that DCD hearts in Greyhound dogs could be resuscitated and preserved by continuous cold crystalloid perfusion but not by cold static storage and could demonstrate excellent contractile and metabolic function on an in vitro system. In the current study, we demonstrate that resuscitated DCD hearts are transplantable. METHODS: Donor Greyhound dogs (n = 12) were divided into perfusion (n = 8) and cold static storage (n = 4) groups. General anesthesia was induced and ventilation ceased for 30 minutes to achieve circulatory death. Donor cardiectomy was performed, and for 4 hours the heart was preserved by controlled reperfusion, followed by continuous cold perfusion with an oxygenated crystalloid perfusate or by static cold storage, after which orthotopic heart transplantation was performed. Recovery was assessed over 4 hours by hemodynamic monitoring. RESULTS: During cold perfusion, hearts showed continuous oxygen consumption and low lactate levels, indicating aerobic metabolism. The 8 dogs in the perfusion group were weaned off bypass, and 4 hours after bypass produced cardiac output of 4.73 ± 0.51 liters/min, left ventricular power of 7.63 ± 1.32 J/s, right ventricular power of 1.40 ± 0.43 J/s, and left ventricular fractional area shortening of 39.1% ± 5.2%, all comparable to pre-transplant values. In the cold storage group, 3 of 4 animals could not be weaned from cardiopulmonary bypass, and the fourth exhibited low-level function. CONCLUSIONS: Cold crystalloid perfusion, but not cold static storage, can resuscitate and preserve the DCD donor heart in a canine model of heart transplantation, thus rendering it transplantable. Controlled reperfusion and cold crystalloid perfusion have potential for clinical application in DCD transplantation.


Subject(s)
Heart Diseases/surgery , Heart Transplantation/methods , Isotonic Solutions/pharmacology , Organ Preservation/methods , Perfusion/methods , Tissue Donors , Tissue and Organ Procurement/methods , Animals , Cryopreservation , Crystalloid Solutions , Disease Models, Animal , Dogs , Rehydration Solutions
10.
Artif Organs ; 40(9): 894-903, 2016 Sep.
Article in English | MEDLINE | ID: mdl-26748566

ABSTRACT

Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure.


Subject(s)
Heart Failure/therapy , Heart Ventricles/surgery , Heart-Assist Devices , Animals , Equipment Design , Female , Heart Failure/physiopathology , Heart Failure/surgery , Heart Ventricles/physiopathology , Hemodynamics , Models, Cardiovascular , Pulmonary Circulation , Sheep , Vascular Resistance , Ventricular Function, Left , Ventricular Function, Right
11.
Int J Artif Organs ; 38(9): 501-7, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26391365

ABSTRACT

INTRODUCTION: Left ventricular assist devices are crucial in rehabilitation of patients with end-stage heart failure. Whether cardiopulmonary function is enhanced with higher pump output is unknown. METHODS: 10 patients (aged 39±16 years, mean±SD) underwent monitored adjustment of pump speed to determine minimum safe low speed and maximum safe high speed at rest. Patients were then randomized to these speed settings and underwent three 6-minute walk tests (6MWT) and symptom-limited cardiopulmonary stress tests (CPX) on separate days. RESULTS: Pump speed settings (low, normal and high) resulted in significantly different resting pump flows of 4.43±0.6, 5.03±0.94, and 5.72±1.2 l/min (P<.001). There was a significant enhancement of pump flows (greater at higher speed settings) with exercise (P<0.05). Increased pump speed was associated with a trend to increased 6MWT distance (P=.10); and CPX exercise time (p=.27). Maximum workload achieved and peak oxygen consumption were significantly different comparing low to high pump speed settings only (P<.05). N-terminal-pro-B-type natriuretic peptide release was significantly reduced at higher pump speed with exercise (P<.01). CONCLUSIONS: We have found that alteration of pump speed setting resulted in significant variation in estimated pump flow. The high-speed setting was associated with lower natriuretic hormone release consistent with lower myocardial wall stress. This did not, however, improve exercise tolerance.


Subject(s)
Exercise Tolerance , Heart-Assist Devices , Adolescent , Adult , Aged , Biomarkers/blood , Blood Pressure , Carbon Dioxide/metabolism , Exercise Test , Female , Humans , Lactic Acid/blood , Male , Middle Aged , Natriuretic Peptide, Brain/blood , Oxygen Consumption , Peptide Fragments/blood , Pulmonary Ventilation , Young Adult
12.
Artif Organs ; 39(8): 681-90, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26146861

ABSTRACT

This study in five large greyhound dogs implanted with a VentrAssist left ventricular assist device focused on identification of the precise site and physiological changes induced by or underlying the complication of left ventricular suction. Pressure sensors were placed in left and right atria, proximal and distal left ventricle, and proximal aorta while dual perivascular and tubing ultrasonic flow meters measured blood flow in the aortic root and pump outlet cannula. When suction occurred, end-systolic pressure gradients between proximal and distal regions of the left ventricle on the order of 40-160 mm Hg indicated an occlusive process of variable intensity in the distal ventricle. A variable negative flow difference between end systole and end diastole (0.5-3.4 L/min) was observed. This was presumably mediated by variable apposition of the free and septal walls of the ventricle at the pump inlet cannula orifice which lasted approximately 100 ms. This apposition, by inducing an end-systolic flow deficit, terminated the suction process by relieving the imbalance between pump requirement and delivery from the right ventricle. Immediately preceding this event, however, unnaturally low end-systolic pressures occurred in the left atrium and proximal left ventricle which in four dogs lasted for 80-120 ms. In one dog, however, this collapse progressed to a new level and remained at approximately -5 mm Hg across four heart beats at which point suction was relieved by manual reduction in pump speed. Because these pressures were associated with a pulmonary capillary wedge pressure of -5 mm Hg as well, they indicate total collapse of the entire pulmonary venous system, left atrium, and left ventricle which persisted until pump flow requirement was relieved by reducing pump speed. We suggest that this collapse caused the whole vascular region from pulmonary capillaries to distal left ventricle to behave as a Starling resistance which further reduced right ventricular output thus contributing to a major reduction in pump flow. We contend that similar complications of manual speed control also occur in the human subject and remain a major unsolved problem in the clinical management of patients implanted with rotary blood pumps.


Subject(s)
Heart-Assist Devices/adverse effects , Hemodynamics , Prosthesis Failure , Ventricular Dysfunction, Left/etiology , Ventricular Function, Left , Animals , Disease Models, Animal , Dogs , Models, Cardiovascular , Prosthesis Design , Stroke Volume , Time Factors , Transducers, Pressure , Vascular Resistance , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/physiopathology , Ventricular Pressure
13.
PLoS One ; 10(4): e0121413, 2015.
Article in English | MEDLINE | ID: mdl-25849979

ABSTRACT

In this study, we evaluate a preload-based Starling-like controller for implantable rotary blood pumps (IRBPs) using left ventricular end-diastolic pressure (PLVED) as the feedback variable. Simulations are conducted using a validated mathematical model. The controller emulates the response of the natural left ventricle (LV) to changes in PLVED. We report the performance of the preload-based Starling-like controller in comparison with our recently designed pulsatility controller and constant speed operation. In handling the transition from a baseline state to test states, which include vigorous exercise, blood loss and a major reduction in the LV contractility (LVC), the preload controller outperformed pulsatility control and constant speed operation in all three test scenarios. In exercise, preload-control achieved an increase of 54% in mean pump flow ([Formula: see text]) with minimum loading on the LV, while pulsatility control achieved only a 5% increase in flow and a decrease in mean pump speed. In a hemorrhage scenario, the preload control maintained the greatest safety margin against LV suction. PLVED for the preload controller was 4.9 mmHg, compared with 0.4 mmHg for the pulsatility controller and 0.2 mmHg for the constant speed mode. This was associated with an adequate mean arterial pressure (MAP) of 84 mmHg. In transition to low LVC, [Formula: see text] for preload control remained constant at 5.22 L/min with a PLVED of 8.0 mmHg. With regards to pulsatility control, [Formula: see text] fell to the nonviable level of 2.4 L/min with an associated PLVED of 16 mmHg and a MAP of 55 mmHg. Consequently, pulsatility control was deemed inferior to constant speed mode with a PLVED of 11 mmHg and a [Formula: see text] of 5.13 L/min in low LVC scenario. We conclude that pulsatility control imposes a danger to the patient in the severely reduced LVC scenario, which can be overcome by using a preload-based Starling-like control approach.


Subject(s)
Heart-Assist Devices , Models, Cardiovascular , Pulsatile Flow/physiology , Ventricular Function, Left/physiology , Computer Simulation , Humans
14.
Artif Organs ; 39(2): E24-35, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25345482

ABSTRACT

The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and substantially reduced the arterial pressure upon HUT.


Subject(s)
Computer Simulation , Exercise , Heart-Assist Devices , Hemodynamics , Models, Cardiovascular , Blood Pressure , Cardiac Output , Humans
15.
Artif Organs ; 38(3): E57-67, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24422872

ABSTRACT

In recent years, extensive studies have been conducted in the area of pumping state detection for implantable rotary blood pumps. However, limited studies have focused on automatically identifying the aortic valve non-opening (ANO) state despite its importance in the development of control algorithms aiming for myocardial recovery. In the present study, we investigated the performance of 14 ANO indices derived from the pump speed waveform using four different types of classifiers, including linear discriminant analysis, logistic regression, back propagation neural network, and k-nearest neighbors (KNN). Experimental measurements from four greyhounds, which take into consideration the variations in cardiac contractility, systemic vascular resistance, and total blood volume were used. By having only two indices, (i) the root mean square value, and (ii) the standard deviation, we were able to achieve an accuracy of 92.8% with the KNN classifier. Further increase of the number of indices to five for the KNN classifier increases the overall accuracy to 94.6%.


Subject(s)
Aortic Valve , Heart-Assist Devices , Models, Cardiovascular , Pulsatile Flow , Animals , Dogs
16.
Artif Organs ; 38(7): 587-93, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24274084

ABSTRACT

Clinically adequate implementation of physiological control of a rotary left ventricular assist device requires a sophisticated technique such as the recently proposed method based on the Frank-Starling mechanism. In this mechanism, the stroke volume of the heart increases in response to an increase in the volume of blood filling the left ventricle at the end of diastole. To emulate this process, changes in pump speed need to automatically regulate pump flow to ensure that the combined output of the left ventricle and pump match the output of the right ventricle across changing cardiovascular states. In this approach, we exploit the linear relationship between estimated mean pump flow (Q ̅ est) and pump flow pulsatility (PIQp) in a tracking control algorithm based on sliding mode control. The immediate response of the controller was assessed using a lumped parameter model of the cardiovascular system (CVS) and pump from which could be extracted both Q ̅ est and PIQp. Two different perturbations from the resting state in the presence of left ventricular failure were tested. The first was blood loss requiring a reduction in pump flow to match the reduced output from the right ventricle and to avoid the complication of ventricular suction. The second was exercise, requiring an increase in pump flow. The sliding mode controller induced the required changes in Qp within approximately five heart beats in the blood loss simulation and eight heart beats in the exercise simulation without clinically significant transients or steady-state errors.


Subject(s)
Heart Failure/therapy , Heart-Assist Devices , Algorithms , Computer Simulation , Heart Failure/physiopathology , Heart Failure/surgery , Heart Ventricles/physiopathology , Humans , Models, Cardiovascular , Prosthesis Design , Pulsatile Flow , Ventricular Function, Left
17.
Artif Organs ; 38(3): E46-56, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24372519

ABSTRACT

The application of rotary left ventricular (LV) assist devices (LVADs) is expanding from bridge to transplant, to destination and bridge to recovery therapy. Conventional constant speed LVAD controllers do not regulate flow according to preload, and can cause over/underpumping, leading to harmful ventricular suction or pulmonary edema, respectively. We implemented a novel adaptive controller which maintains a linear relationship between mean flow and flow pulsatility to imitate native Starling-like flow regulation which requires only the measurement of VAD flow. In vitro controller evaluation was conducted and the flow sensitivity was compared during simulations of postural change, pulmonary hypertension, and the transition from sleep to wake. The Starling-like controller's flow sensitivity to preload was measured as 0.39 L/min/mm Hg, 10 times greater than constant speed control (0.04 L/min/mm Hg). Constant speed control induced LV suction after sudden simulated pulmonary hypertension, whereas Starling-like control reduced mean flow from 4.14 to 3.58 L/min, maintaining safe support. From simulated sleep to wake, Starling-like control increased flow 2.93 to 4.11 L/min as a response to the increased residual LV pulsatility. The proposed controller has the potential to better match device outflow to patient demand in comparison with conventional constant speed control.


Subject(s)
Heart-Assist Devices , Models, Cardiovascular , Pulsatile Flow/physiology , Ventricular Function, Left/physiology , Equipment Design , Humans
18.
Article in English | MEDLINE | ID: mdl-24109777

ABSTRACT

In general, patient variability and diverse environmental operation makes physiological control of a left ventricular assist device (LVAD) a complex and complicated problem. In this work, we implement a Starling-like controller which adjusts mean pump flow using pump flow pulsatility as the feedback parameter. The linear relationship between mean pump flow and pump flow pulsatility forms the desired flow of the Starling-like controller. A tracking control algorithm based on sliding mode control (SMC) has been implemented. The controller regulates the estimated mean pulsatile flow (Qp) and flow pulsatility (PIQp) generated from a model of the assist device. A lumped parameter model of the cardiovascular system (CVS) was used to test the control strategy. The immediate response of the controller was evaluated by inducing a fall in left ventricle (LV) preload following a reduction in circulating blood volume. The simulation supports the speed and robustness of the proposed strategy.


Subject(s)
Heart-Assist Devices , Algorithms , Computer Simulation , Feedback , Heart Failure/physiopathology , Heart Failure/therapy , Heart Ventricles/physiopathology , Humans , Models, Cardiovascular , Pulsatile Flow
19.
Artif Organs ; 37(8): 695-703, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23638682

ABSTRACT

This multicenter study examines in detail the spontaneous increase in pump flow at fixed speed that occurs in exercise. Eight patients implanted with the VentrAssist rotary blood pump were subjected to maximal and submaximal cycle ergometry studies, the latter being completed with patients supine and monitored with right heart catheter and echocardiography. Maximal exercise studies conducted in each patient at three different pump speeds on separate days established initially the magnitude and consistency of increases in pump flow that correlated well with changes in heart rate. However, there was considerable variation, coefficients of variation for mean heart rate and pump flow being 47.9 and 49.3%, respectively. Secondly, these studies indicated that increasing pump flows caused significant improvements in maximal exercise capacity. An increase of 2.1 L/min (35%) in maximum blood flow caused 12 W (16%) further increase in achievable work, 1.26 (9.3%) mL/kg/min in maximal oxygen uptake, and 2.3 (23%) mL/kg/min in anaerobic threshold. Mean increases in lactate were 0.85 mm (24%), but mean B-type natiuretic peptide fell by 126 mm, (-78%). From submaximal supine exercise studies, multiple linear regression of pump flow on factors thought to underlie the spontaneous increase in pump flow indicated that it was associated with increases in heart rate (P = 0.039), pressure gradient across the left ventricle (P = 0.032), and right atrial pressure (P = 0.003). These changes have implications for the recently reported Starling-like controller for pump flow based on pump pulsatility values, which emulates the Starling curve relating pump output to left ventricular preload. Unmodified, the controller would not permit the full benefits of this effect to be afforded to patients implanted with rotary blood pumps. A modification to the pump control algorithm is proposed to eliminate this problem.


Subject(s)
Exercise/physiology , Heart-Assist Devices , Adult , Aged , Female , Heart Rate , Humans , Male , Middle Aged , Pulsatile Flow , Young Adult
20.
Physiol Meas ; 34(1): R1-27, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23242235

ABSTRACT

From the moment of creation to the moment of death, the heart works tirelessly to circulate blood, being a critical organ to sustain life. As a non-stopping pumping machine, it operates continuously to pump blood through our bodies to supply all cells with oxygen and necessary nutrients. When the heart fails, the supplement of blood to the body's organs to meet metabolic demands will deteriorate. The treatment of the participating causes is the ideal approach to treat heart failure (HF). As this often cannot be done effectively, the medical management of HF is a difficult challenge. Implantable rotary blood pumps (IRBPs) have the potential to become a viable long-term treatment option for bridging to heart transplantation or destination therapy. This increases the potential for the patients to leave the hospital and resume normal lives. Control of IRBPs is one of the most important design goals in providing long-term alternative treatment for HF patients. Over the years, many control algorithms including invasive and non-invasive techniques have been developed in the hope of physiologically and adaptively controlling left ventricular assist devices and thus avoiding such undesired pumping states as left ventricular collapse caused by suction. In this paper, we aim to provide a comprehensive review of the developments of control systems and techniques that have been applied to control IRBPs.


Subject(s)
Heart Failure/therapy , Heart Ventricles/physiopathology , Heart-Assist Devices , Coronary Circulation , Heart Failure/physiopathology , Humans