Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Acta Chim Slov ; 69(1): 49-59, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-35298022

ABSTRACT

An HPLC-UV/FLD method for simultaneous detection of ten antibiotics in surface waters was developed. Antibiotics were extracted from water using solid phase extraction. An Atlantis T3 column was used with acetonitrile and 0.05% trifluoroacetic acid as a mobile phase for separation, with a total running time of 45 min. Signal detection was performed at 280 nm; fluoroquinolones were additionally quantified by fluorescence detection. Validation parameters such as linearity, recovery and precision were evaluated. The limits of detection (LOD) in river waters were in the range 0.1-1.3 µg/L for antibiotics detected by UV, and 0.039 and 0.073 µg/Lfor fluoroquinolones detected by FLD. LOD are sufficiently low to consider this method as a first alternative for HPLC-MS methods that will allow alerting for the presence of antibiotics in surface waters. This screening method is rapid, sensitive, reproducible and economical.


Subject(s)
Anti-Bacterial Agents , Water Pollutants, Chemical , Chromatography, High Pressure Liquid/methods , Mass Spectrometry , Solid Phase Extraction/methods
2.
J Chromatogr Sci ; 52(10): 1281-7, 2014.
Article in English | MEDLINE | ID: mdl-24596421

ABSTRACT

A chromatographic method was implemented and validated for the simultaneous determination of antimicrobials proposed for the treatment of mycetoma: three fluoroquinolones: ciprofloxacin, moxifloxacin and sparfloxacin; two oxazolidinones: DA-7157 (DA2; torezolid) and its prodrug DA-7218 (DA1). Separation of analytes was achieved on an Atlantis dC18 column (150 × 4.6 mm i.d., 5 µm particle size) with a mobile phase composed of acetonitrile and trifluoroacetic acid 0.1% (v/v) using a gradient program. Total running time was 30 min. Quantification of sparfloxacin was carried out using a DAD at 278 nm; the oxazolidinones DA1 and DA2 and the quinolones ciprofloxacin and moxifloxacin were analyzed by fluorescence with an excitation wavelength of 292 nm and an emission wavelength of 525 nm. Intraday precision was in the range of 3.2 and 14.1%. Linearity range was from 0.3 to 10 µg/mL for sparfloxacin using DAD detector, and from 0.2 to 10 µg/mL for ciprofloxacin, 0.3 to 10 µg/mL for DA2, 0.4 to 10 µg/mL for DA1 and 0.04 to 10 µg/mL for moxifloxacin with fluorescence detector. Acetonitrile was used to precipitate proteins from plasma. Recoveries at low, medium and high concentration were between 80 and 120%. Limits of quantification were between 0.04 and 0.4 µg/mL in plasma. The method can be applied for individual or simultaneous determination of the antimicrobials in plasma.


Subject(s)
Chromatography, High Pressure Liquid/methods , Fluoroquinolones/blood , Oxazolidinones/blood , Animals , Drug Stability , Limit of Detection , Linear Models , Mice , Mice, Inbred BALB C , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...