Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 31(15): 23889-23896, 2023 Jul 17.
Article in English | MEDLINE | ID: mdl-37475229

ABSTRACT

We report real-time monitoring of coarse aerosol particle distribution in a 9 m wide full-scale industrial boiler using a broadband supercontinuum lidar. The technique utilizes the light backscattered from the aerosol to map the extinction profile using the Klett inversion method, with measured extinction values of 0.04 - 0.2 m-1 across the furnace. The technique further exploits differential absorption of water molecules in the 1.25 - 1.5 µm region to map the water vapor concentration profile in the furnace up to a distance of 3.9 m with a spatial resolution of 30 cm. We also take advantage of the strong reflection from the boiler back-wall to simultaneously measure the average water vapor temperature and concentration in the boiler in good agreement with reference readings from the boiler. Our results open novel perspectives for versatile 3D profiling of flue gas parameters and other industrial process analysis.

2.
Sci Rep ; 12(1): 19392, 2022 Nov 12.
Article in English | MEDLINE | ID: mdl-36371513

ABSTRACT

We report a novel hyperspectral sensor employing a Fabry-Pérot interferometer based on micro-electro-mechnical system and a custom mid-infrared supercontinuum laser. The Fabry-Pérot interferometer allows on-axis filtering, of spectral components of supercontinuum light backscattered from a target, with a spectral resolution of about 25 nm. We demonstrated hyperspectral identification of black polypropylene (PP) and polyethylene (PE500) using the 3-3.5 [Formula: see text]m region of the supercontinuum spectrum and a corresponding measurement rate of 62.5 spectra / s. The resulted spectra show excellent agreement with the reference based on an FTIR spectrometer. Furthermore, we showed that the coloring of the plastics has no effect on their identification at this wavelength range.

3.
Opt Lett ; 44(17): 4223-4226, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31465367

ABSTRACT

We developed a short-range light detection and ranging system using a supercontinuum (SC) source spectrally tailored to cover the ro-vibrational transition energies of desired components of a flue gas. The system enables remote measurements of the gas parameters, including temperature and concentration which play a key role in the performance of combustion power plants. The technique requires only one inspection window and, thus, can be used in combustion units with limited access. It exploits differential absorption between specific wavelength bands of the gas absorption spectrum. The transmittance of an individual wavelength band is derived from the detected backscattered temporal intensity of the SC pulses. We demonstrate water vapor temperature measurement in the range of 400°C-900°C in a laboratory furnace with the use of only two wavelength bands. Using more than two wavelength bands, the technique can be further extended to simultaneously measure temperature and concentration. By varying the direction of the incident beam in a non-parallel plane, a full 3D profile is also obtainable.

SELECTION OF CITATIONS
SEARCH DETAIL
...