Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Chem ; 18(1): 111, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38863068

ABSTRACT

A new, sensitive, and rapid isocratic reversed phase chromatographic method (RP-HPLC-UV) was developed for simultaneous separation of two newly co-formulated antiulcer mixtures; Amoxicillin, Vonoprazan and Clarithromycin [Mixture (I)], and Amoxicillin, Lansoprazole and Clarithromycin [Mixture (II)]. Analytical separation was performed using a Promosil C18 column and ultraviolet detection at 210 nm. The separation was achieved within only 8 min. For both mixtures, an aqueous solution, composed of (Acetonitrile: Methanol: 0. 2 M phosphoric acid) within ratio of (30: 30: 40) adjusted to final pH 3.0, was the mobile phase. This method was validated as per the International Conference on Harmonization guidelines. The linearity ranges of these proposed method of the (Mixture (I)) were 25.0-400.0 µg/mL Amoxicillin, 0.5-8.0 µg/mL Vonoprazan, and 12.5-200.0 µg/mL Clarithromycin. And the linearity ranges of the (Mixture (II)) were 10.0-300.0 µg/mL Amoxicillin, 0.3-9.0 µg/mL Lansoprazole and 5.0-150.0 µg/mL Clarithromycin. This method was firstly applied for effective separation of Amoxicillin, Vonoprazan and Clarithromycin [Mixture (I)]. It fulfilled good repeatability, sensitivity, and accuracy (R.S.D. < 2.0%). The mean recoveries of the analytes in their Tri-Pak formulations were acceptable. The greenness of the developed chromatographic methods was assessed using an Eco-scale method and it was applied for content uniformity testing as per the United States Pharmacopoeia (USP) and the acceptance value of Amoxicillin, in Mixture (I) was 2.88, the acceptance values for Amoxicillin, Lansoprazole in Mixture (II) were 2.592, 2.424, respectively.

2.
ACS Omega ; 8(22): 19351-19366, 2023 Jun 06.
Article in English | MEDLINE | ID: mdl-37305261

ABSTRACT

In this study, two new series of 3-cyanopyridinones (3a-e) and 3-cyanopyridines (4a-e) were synthesized and evaluated for their cytotoxicity and Pim-1 kinase inhibitory activity adopting 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide (MTT) assay and in vitro Pim-1 kinase inhibition assay, respectively. Most of the tested compounds revealed promising cytotoxicity against HepG-2, HCT-116, MCF-7, and PC-3 cell lines. Among them, compounds 4c and 4d showed more potent cytotoxicity against the HePG2 cell line with IC50 = 8.02 ± 0.38 and 6.95 ± 0.34 µM, respectively, than that of the reference 5-FU (IC50 = 9.42 ± 0.46 µM). Moreover, compound 4c was more potent against HCT-116 (IC50 = 7.15 ± 0.35 µM) than 5-FU (IC50 = 8.01 ± 0.39 µM), while compound 4d with IC50 = 8.35 ± 0.42 µM displayed comparable activity to that of the reference drug. Furthermore, high cytotoxic activity was manifested by compounds 4c and 4d against MCF-7 and PC3 cell lines. Our results have also indicated that compounds 4b, 4c, and 4d elicited remarkable inhibition of Pim-1 kinase; 4b and 4c showed equipotent inhibitory activity to that of the reference quercetagetin. Meanwhile, 4d displayed IC50 = 0.46 ± 0.02 µM, showed the best inhibitory activity among the tested compounds, and was more potent than quercetagetin (IC50 = 0.56 ± 0.03 µM). For optimization of the results, docking study of the most potent compounds 4c and 4d in the Pim-1 kinase active site was carried out and compared with both quercetagetin and the reported Pim-1 inhibitor A (VRV), and the results were consistent with those of the biological study. Consequently, compounds 4c and 4d are worthy of further investigations toward the discovery of Pim-1 kinase inhibitors as drug candidates for cancer therapy. Compound 4b was successfully radiolabeled with radioiodine-131, and its biodistribution in Ehrlich ascites carcinoma (EAC)-bearing mice showed more observable uptake in tumor sites, and hence, it can be introduced as a new radiolabeled agent for tumor imaging and therapy.

3.
Sci Rep ; 13(1): 305, 2023 01 06.
Article in English | MEDLINE | ID: mdl-36609681

ABSTRACT

A rapid and sensitive isocratic ion-pair chromatographic method was developed for the accurate analysis of ternary mixtures of formoterol, tiotropium, and ciclesonide in their novel combined inhalation that is widely used for the symptomatic treatment of patients with chronic obstructive disease. Analytical separation was performed using a C8 column and ion pair mobile phase composed of acetonitrile: acidified deionized water (55: 45% v/v) containing 0.025% sodium dodecyl sulfate. The pH was adjusted to 3.0 using orthophosphoric acid and eluted isocratically at 2.0 mL/min and 40 °C applying UV detection at 237 nm. The calibration ranges were found to be 0.3-9.0 µg/mL for formoterol, 0.45-13.5 µg/mL for tiotropium, and 10.0-300.0 µg/mL concerning ciclesonide. The proposed method exhibited good repeatability, accuracy, and sensitivity (R.S.D. < 2.0%). The approach is rapid (run time does not exceed 15 min) and achieves satisfactory resolution (resolution factors = 7.45 and 5.3 between formoterol and tiotropium and tiotropium and ciclesonide respectively). The sensitivity and the efficiency of the proposed method permit their successful estimation with a recovery percentage ± SD of 99.33% ± 0.43 for formoterol, 99.15% ± 0.60 for tiotropium, and 99.90% ± 0.41 for ciclesonide.


Subject(s)
Coronavirus Infections , Coronavirus , Humans , Tiotropium Bromide , Formoterol Fumarate , Chromatography, High Pressure Liquid/methods , Respiratory Therapy
4.
BMC Chem ; 13(1): 75, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31384822

ABSTRACT

One of the major causes of mortality all over the world is chronic obstructive pulmonary disease (COPD). Recently approved combined inhaler of formoterol fumarate (FF) and glycopyrronium bromide (GLY) has been used in very low concentrations (µg level/actuation) doses in COPD patients. The first spectrophotometric and advanced highly sensitive liquid chromatography has been achieved successfully throughout this study, permitting validated analysis of dual combined inhaler in raw material as well as pharmaceutical inhaled dosage form. Three sensitive analytical methods were carried out for the simultaneous assay of FF and GLY in their novel combined Metered dose inhaler (MDI). The first method depends on measuring the first derivative amplitudes at 208.27 nm for FF and at 213.27 nm and 239.86 nm for GLY, respectively. The second method depends on measurement of the first derivative of the ratio spectra at 214 or 229 nm for FF and 240 or 259 nm for GLY, respectively. For the spectrophotometric methods, the linearity ranges were 0.48-9.6 µg/mL for FF and 0.9-18 µg/mL for GLY. For the third method, valid ion-pairing chromatographic method was carried out applying C18 column and isocratic mobile phase of 60% v/v acetonitrile and 40% v/v deionized waster (pH 3.0) enclosing 0.025% sodium dodecyl sulfate, using UV detection adjusted to 210 nm and flow rate of 1.2 mL/min. For the ion-pairing chromatographic method, the linearity ranges were 0.048-4.8 µg/mL for FF and 0.09-9.0 µg/mL for GLY. The developed methods are reproducible, valid and offer efficient resolution between formoterol and glycopyrronium using spectrophotometric methods and highly sensitive and precise chromatographic method. The percent recoveries of the inhaled drugs in their MDI were good. The method was successfully established for the quantitative analysis of FF and GLY in their combined pharmaceutical inhaler capsules to validate the therapeutic efficiency of the combined drugs in quality control labs.

5.
BMC Pregnancy Childbirth ; 19(1): 38, 2019 Jan 18.
Article in English | MEDLINE | ID: mdl-30658605

ABSTRACT

BACKGROUND: Oxytocin for postpartum hemorrhage (PPH) prophylaxis is commonly administered by either intramuscular (IM) injection or intravenous (IV) infusion with both routes recommended equally and little discussion of potential differences between the two. This trial assesses the effectiveness and safety of 10 IU oxytocin administered as IM injection versus IV infusion and IV bolus during the third stage of labor for PPH prophylaxis. METHODS: In two tertiary level Egyptian maternity hospitals, women delivering vaginally without exposure to pre-delivery uterotonics were randomized to one of three prophylactic oxytocin administration groups after delivery of the baby. Blood loss was measured 1 h after delivery, and side effects were recorded. Primary outcomes were mean postpartum blood loss and proportion of women with postpartum blood loss ≥500 ml in this open-label, three-arm, parallel, randomized controlled trial. RESULTS: Four thousand nine hundred thirteen eligible, consenting women were randomized. Compared to IM injection, mean blood loss was 5.9% less in the IV infusion arm (95% CI: -8.5, - 3.3) and 11.1% less in the IV bolus arm (95% CI: -14.7, - 7.8). Risk of postpartum blood loss ≥500 ml in the IV infusion arm was significantly less compared to IM injection (0.8% vs. 1.5%, RR = 0.50, 95% CI: 0.27, 0.91). No side effects were reported in any arm. CONCLUSIONS: Intravenous oxytocin is more effective than intramuscular injection for the prevention of PPH in the third stage of labor. Oxytocin delivered by IV bolus presents no safety concerns after vaginal delivery and should be considered a safe option for PPH prophylaxis. TRIAL REGISTRATION: clinicaltrials.gov # NCT01914419 , posted August 2, 2013.


Subject(s)
Delivery, Obstetric/methods , Labor Stage, Third/drug effects , Oxytocics/administration & dosage , Oxytocin/administration & dosage , Postpartum Hemorrhage/prevention & control , Administration, Intravenous , Adult , Egypt , Female , Humans , Infusions, Intravenous , Injections, Intramuscular , Postpartum Hemorrhage/etiology , Pregnancy , Treatment Outcome
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 210: 387-397, 2019 Mar 05.
Article in English | MEDLINE | ID: mdl-30503784

ABSTRACT

Two sensitive, rapid, and accurate derivative emission spectrofluorimetric methods applying zero crossing techniques were developed for simultaneous determination of binary mixtures of ibuprofen (IBU) and phenylephrine hydrochloride (PHE) in pure powder, synthetic mixture and combined tablets. The proposed methods were performed via measuring the intersected drug derivative amplitude of one drug at the zero crossing points for the other one and vice versa. The two methods rely on the measurement of the combined drugs native fluorescence after excitation at 270 nm in methanol directly, followed by differentiation using first (D1) and second derivative (D2) techniques. Applying the D1, IBU was measured quantitatively at 293.1 nm at zero crossing of PHE, on the other side; PHE was measured quantitatively at 300.7 nm at zero crossing of IBU. By the same way, applying the D2, the wavelengths selected were 303.5 nm for IBU and 312.9 nm for PHE. The concentration plots of derivative fluorescence intensity were rectilinear over the range of 0.5-10 µg/mL and 0.025-0.5 µg/mL for IBU and PHE, respectively. The results obtained with average % recoveries ±â€¯RSD are 99.73 ±â€¯0.72 (IBU, D1), 99.49 ±â€¯0.95 (PHE, D1), 99.79 ±â€¯0.47 (IBU, D2), and 99.88 ±â€¯0.34 (PHE, D2) were in good agreement with the comparison method. The proposed methods offer high sensitivity that enable direct analysis of IBU and PHE in spiked human plasma. The proposed methods were entirely validated in terms of ICH guidelines.


Subject(s)
Ibuprofen/analysis , Phenylephrine/analysis , Spectrometry, Fluorescence/methods , Tablets/analysis , Calibration , Drug Combinations , Humans , Hydrogen-Ion Concentration , Ibuprofen/blood , Limit of Detection , Phenylephrine/blood , Reproducibility of Results , Sensitivity and Specificity , Surface-Active Agents/chemistry
7.
Spectrochim Acta A Mol Biomol Spectrosc ; 204: 464-474, 2018 Nov 05.
Article in English | MEDLINE | ID: mdl-29966902

ABSTRACT

A rapid, and highly sensitive analytical method were developed for the simultaneous determination of indacaterol maleate (IND) and glycopyrronium bromide (GLY) in their inhaler capsules. Valid ion-pairing chromatographic (IPC) method was performed for separation of GLY in presence of IND using C18 column and mobile phase consisting of acetonitrile: acidified deionized water (60:40% v/v) containing 0.02% sodium dodecyl sulfate (SDS) adjusted to pH 3.0 using OPA (orthophosphoric acid) isocratically eluted at 2.0 mL/min. Quantitation was achieved with UV detection at 210 nm. Cyproheptadine was used as an internal standard. The retention times were 1.9 and 2.5 min for IND, and GLY, respectively. For the IPC method, the calibration graphs were linear in the range of 0.66-66.0 µg/mL for IND and 0.3-30.0 µg/mL for GLY. The proposed method are rapid, reproducible (R.S.D. <2.0%) and achieves satisfactory resolution between IND and GLY (resolution factor = 4.23). The mean recoveries of the analytes in their inhaler capsule were satisfactory. It was applied successfully to in vitro dissolution testing using Franz diffusion cell and extended to a content uniformity test consistent with the United States Pharmacopoeia (USP) guidelines and were found to be precise and accurate for the capsules studied with acceptance value of 4.53 and 1.39 for IND and GLY, respectively.


Subject(s)
Chromatography, Liquid/methods , Glycopyrrolate/analysis , Indans/analysis , Quinolones/analysis , Administration, Inhalation , Capsules , Glycopyrrolate/chemistry , Glycopyrrolate/pharmacokinetics , Indans/chemistry , Indans/pharmacokinetics , Limit of Detection , Linear Models , Models, Chemical , Quinolones/chemistry , Quinolones/pharmacokinetics , Reproducibility of Results
9.
Pediatr Nephrol ; 30(10): 1835-42, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25980471

ABSTRACT

BACKGROUND: Iron deficiency anemia (IDA) is the most common nutritional deficiency in the world. The aim of our study was to evaluate and compare renal functional and structural integrity in 50 infants with IDA and 50 healthy controls and to assess the relation between IDA and oxidative stress and response to iron therapy. METHODS: This was a prospective study in which peripheral blood samples were collected from all study subjects and the following laboratory investigations performed: serum iron profile, urinary microalbumin, urinary leucine aminopeptidase (LAP), fractional excretion of sodium (FeNa), serum total antioxidant capacity (TAC), serum malondialdehyde (MDA), serum and urinary trace elements (iron, copper, zinc, calcium and magnesium). All patients received oral iron therapy and were followed-up for 3 months. RESULTS: The levels of baseline urinary markers were higher among the patients with IDA than among the controls (p < 0.05). Patients had a lower pre-therapy TAC and lower serum zinc and magnesium levels than controls as well as higher MDA and serum copper levels (p < 0.05). MDA level was positively correlated to microalbumin and LAP level (p < 0.05). Urinary LAP concentration was positively correlated to urinary trace element concentrations (p < 0.05). A significant decrease in microalbumin, LAP, FeNa, and urinary trace elements was observed post-iron therapy while hemoglobin and ferritin levels were increased (p < 0.05). CONCLUSION: Among the study subjects, IDA had an adverse influence on renal functional and structural integrity which could be reversed with iron therapy. Oxidative stress played an important role in the pathogenesis of renal injury in IDA.


Subject(s)
Anemia, Iron-Deficiency/physiopathology , Glomerular Filtration Rate/physiology , Iron Compounds/therapeutic use , Iron/blood , Kidney/physiopathology , Oxidative Stress , Renal Insufficiency/prevention & control , Administration, Oral , Anemia, Iron-Deficiency/drug therapy , Anemia, Iron-Deficiency/metabolism , Biomarkers/blood , Biomarkers/urine , Child, Preschool , Female , Follow-Up Studies , Humans , Infant , Iron Compounds/administration & dosage , Male , Prospective Studies , Reactive Oxygen Species/metabolism , Renal Insufficiency/etiology , Renal Insufficiency/physiopathology , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...