Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(12)2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38931594

ABSTRACT

A prerequisite for continuous transport systems' operation is their digital transformation, which interprets operating conditions based on the availability of a wide range of data and information in the form of measured quantities that can be obtained, for example, by experimental measurement. To implement digital transformation in continuous transport systems, it is necessary to examine and analyze the informative value of individual measured quantities in detail. Research in this area must focus on identifying addressable quantities with a clear, informative value. Such an approach enables the monitoring of continuous transport systems operation and performance of operational diagnostics, the objective of which should be identifying undesirable operating conditions. Within this paper, research will be presented aiming to verify the hypothesis that, based on a measurement of selected parameters, it is possible to identify belt mistracking in a continuous transport system. Belt mistracking is an undesirable condition that can cause a conveyor belt to converge and thus seriously turn off an entire transport system. The research results confirmed the established hypothesis. Based on this, an evaluation algorithm was created for on-time evaluation. The proposed algorithm is also suitable for the needs of a digital twin of a continuous transport system.

2.
Sensors (Basel) ; 24(9)2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38732942

ABSTRACT

The article presents the analysis, design, and low-cost implementation of application-specific AD converters for M-sequence-based UWB applications to minimize and integrate the whole UWB sensor system. Therefore, the main goal of this article is to integrate the AD converter's own design with the UWB analog part into the system-in-package (SiP) or directly into the system-on-a-chip (SoC), which cannot be implemented with commercial AD converters, or which would be disproportionately expensive. Based on the current and used UWB sensor system requirements, to achieve the maximum possible bandwidth in the proposed semiconductor technology, a parallel converter structure is designed and presented in this article. Moreover, 5-bit and 4-bit parallel flash AD converters were initially designed as part of the research and design of UWB M-sequence radar systems for specific applications, and are briefly introduced in this article. The requirements of the newly proposed specific UWB M-sequence systems were established based on the knowledge gained from these initial designs. After thorough testing and evaluation of the concept of the early proposed AD converters for these specific UWB M-sequence systems, the design of a new AD converter was initiated. After confirming sufficient characteristics based on the requirements of UWB M-sequence systems for specific applications, a 7-bit AD converter in low-cost 0.35 µm SiGe BiCMOS technology from AMS was designed, fabricated, and presented in this article. The proposed 7-bit AD converter achieves the following parameters: ENOB = 6.4 bits, SINAD = 38 dB, SFDR = 42 dBc, INL = ±2-bit LSB, and DNL = ±1.5 LSB. The maximum sampling rate reaches 1.4 Gs/s, the power consumption at 20 Ms/s is 1050 mW, and at 1.4 Gs/s is 1290 mW, with a power supply of -3.3 V.

3.
Sensors (Basel) ; 21(10)2021 May 19.
Article in English | MEDLINE | ID: mdl-34069718

ABSTRACT

A novel method of analog-to-information conversion-the random interval integration-is proposed and studied in this paper. This method is intended primarily for compressed sensing of aperiodic or quasiperiodic signals acquired by commonly used sensors such as ECG, environmental, and other sensors, the output of which can be modeled by multi-harmonic signals. The main idea of the method is based on input signal integration by a randomly resettable integrator before the AD conversion. The integrator's reset is controlled by a random sequence generator. The signal reconstruction employs a commonly used algorithm based on the minimalization of a distance norm between the original measurement vector and vector calculated from the reconstructed signal. The signal reconstruction is performed by solving an overdetermined problem, which is considered a state-of-the-art approach. The notable advantage of random interval integration is simple hardware implementation with commonly used components. The performance of the proposed method was evaluated using ECG signals from the MIT-BIH database, multi-sine, and own database of environmental test signals. The proposed method performance is compared to commonly used analog-to-information conversion methods: random sampling, random demodulation, and random modulation pre-integration. A comparison of the mentioned methods is performed by simulation in LabVIEW software. The achieved results suggest that the random interval integration outperforms other single-channel architectures. In certain situations, it can reach the performance of a much-more complex, but commonly used random modulation pre-integrator.

SELECTION OF CITATIONS
SEARCH DETAIL
...