1.
Am J Ophthalmol ; 170: 223-227, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27544479

ABSTRACT

PURPOSE: To report on the utility of a computer tablet-based method for automated testing of visual acuity in children based on the principles of game design. We describe the testing procedure and present repeatability as well as agreement of the score with accepted visual acuity measures. DESIGN: Reliability and validity study. METHODS: Setting: Manchester Royal Eye Hospital Pediatric Ophthalmology Outpatients Department. PATIENT POPULATION: Total of 112 sequentially recruited patients. INTERVENTION: For each patient 1 eye was tested with the Mobile Assessment of Vision by intERactIve Computer for Children (MAVERIC-C) system, consisting of a software application running on a computer tablet, housed in a bespoke viewing chamber. The application elicited touch screen responses using a game design to encourage compliance and automatically acquire visual acuity scores of participating patients. Acuity was then assessed by an examiner with a standard chart-based near ETDRS acuity test before the MAVERIC-C assessment was repeated. MAIN OUTCOME MEASURE: Reliability of MAVERIC-C near visual acuity score and agreement of MAVERIC-C score with near ETDRS chart for visual acuity. RESULTS: Altogether, 106 children (95%) completed the MAVERIC-C system without assistance. The vision scores demonstrated satisfactory reliability, with test-retest VA scores having a mean difference of 0.001 (SD ±0.136) and limits of agreement of 2 SD (LOA) of ±0.267. Comparison with the near EDTRS chart showed agreement with a mean difference of -0.0879 (±0.106) with LOA of ±0.208. CONCLUSIONS: This study demonstrates promising utility for software using a game design to enable automated testing of acuity in children with ophthalmic disease in an objective and accurate manner.


Subject(s)
Computers, Handheld , Diagnosis, Computer-Assisted , Video Games , Vision Tests/instrumentation , Visual Acuity/physiology , Adolescent , Child , Child, Preschool , Female , Humans , Male , Reproducibility of Results
2.
Graefes Arch Clin Exp Ophthalmol ; 254(5): 891-9, 2016 May.
Article in English | MEDLINE | ID: mdl-26899899

ABSTRACT

PURPOSE: Many eye diseases require on-going assessment for optimal management, creating an ever-increasing burden on patients and hospitals that could potentially be reduced through home vision monitoring. However, there is limited evidence for the utility of current applications and devices for this. To address this, we present a new automated, computer tablet-based method for self-testing near visual acuity (VA) for both high and low contrast targets. We report on its reliability and agreement with gold standard measures. METHODS: The Mobile Assessment of Vision by intERactIve Computer (MAVERIC) system consists of a calibrated computer tablet housed in a bespoke viewing chamber. Purpose-built software automatically elicits touch-screen responses from subjects to measure their near VA for either low or high contrast acuity. Near high contrast acuity was measured using both the MAVERIC system and a near Landolt C chart in one eye for 81 patients and low contrast acuity using the MAVERIC system and a 25 % contrast near EDTRS chart in one eye of a separate 95 patients. The MAVERIC near acuity was also retested after 20 min to evaluate repeatability. RESULTS: Repeatability of both high and low contrast MAVERIC acuity measures, and their agreement with the chart tests, was assessed using the Bland-Altman comparison method. One hundred and seventy-three patients (96 %) completed the self- testing MAVERIC system without formal assistance. The resulting MAVERIC vision demonstrated good repeatability and good agreement with the gold-standard near chart measures. CONCLUSIONS: This study demonstrates the potential utility of the MAVERIC system for patients with ophthalmic disease to self-test their high and low contrast VA. The technique has a high degree of reliability and agreement with gold standard chart based measurements.


Subject(s)
Computers, Handheld , Contrast Sensitivity/physiology , Diagnosis, Computer-Assisted/instrumentation , Self Care/methods , Vision Disorders/diagnosis , Vision Tests/instrumentation , Visual Acuity/physiology , Algorithms , Female , Humans , Male , Middle Aged , Reproducibility of Results , Software