Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Life (Basel) ; 13(10)2023 Oct 17.
Article in English | MEDLINE | ID: mdl-37895454

ABSTRACT

BACKGROUND: The femoral neck system (FNS) was introduced as a minimally invasive fixation device for managing femoral neck fractures. OBJECTIVE: To compare radiographic, clinical, and patient-reported outcome measures (PROMs) of femoral neck fracture patients following FNS compared to dynamic hip screw (DHS) implantation combined with an anti-rotational screw. METHODS: Patients who underwent closed reduction and internal fixation of a femoral neck fracture between 2020 and 2022 were retrospectively included. We measured leg length, femoral offset, and centrum-collum-diaphyseal (CCD) angle in plain radiographs. Scar length, Harris Hip Score, short-form health survey 36-item score (SF-36), and Numeric Rating Scale (NRS) were assessed during follow-up visits. RESULTS: We included 43 patients (22 females) with a median age of 66 (IQR 57, 75). In both groups, leg length differences between the injured and the contralateral side increased, and femoral offset and CCD angle differences were maintained over time. FNS patients had shorter scars and reported fewer emotional problems and more energy. There were no differences between groups regarding the remaining SF-36 sub-scores, Harris Hip Score, and NRS. CONCLUSIONS: The FNS allows for a comparable leg length, femoral offset, and CCD angle reconstruction while achieving similarly high functional and global health scores to the DHS.

2.
Eur J Orthop Surg Traumatol ; 33(4): 1185-1192, 2023 May.
Article in English | MEDLINE | ID: mdl-35523973

ABSTRACT

PURPOSE: Purpose of this study was to demonstrate that a single tunnel reconstruction of high-grade acromioclavicular (AC) joint instabilities with implants of the second generation is sufficient for stabilisation, especially in combination with an AC cerclage. METHODS: Patients with an acute AC-joint dislocation type Rockwood III-B and V were included. Besides clinical follow-up examination, radiographs were analysed. The functional outcome measures were Constant Score (CS), Taft score (TS), ACJI score and patient's satisfaction. Horizontal instability was evaluated by clinical examination and radiological with an Alexander view. RESULTS: Thirty-five patients with a mean follow-up of 29 months were included. Ninety-seven per cent were satisfied with their result, with an average Subjective Shoulder Value of 90%. The CS averaged at 90 ± 10 points, TS at 11 ± 1 points and ACJI at 78 ± 18 points. Radiologically, 3 of 29 patients (10%) showed a persisting horizontal instability. The coracoclavicular (CC) distance improved from 22 preoperative to 10 mm postoperative, which was comparable to the contralateral side (10 mm, p = 0.103). At follow-up the CC distance increased to 13 mm (p = 0.0001). CONCLUSION: AC-joint stabilisation with a single tunnel reconstruction using a second-generation implant results in good to excellent clinical results with high patient satisfaction. The additional AC augmentation improves stability in horizontal instable AC-joints and is recommended in all high-grade AC joint stabilisations. Nonetheless, reduction was slightly lost over time due to an elongation or suture failure of the coraco-clavicular fixation. LEVEL OF EVIDENCE: IV.


Subject(s)
Acromioclavicular Joint , Joint Dislocations , Joint Instability , Shoulder Dislocation , Humans , Acromioclavicular Joint/surgery , Treatment Outcome , Arthroscopy/methods , Shoulder Dislocation/surgery , Joint Instability/surgery , Joint Dislocations/surgery , Ligaments, Articular
3.
Unfallchirurgie (Heidelb) ; 126(1): 67-71, 2023 Jan.
Article in German | MEDLINE | ID: mdl-35380265

ABSTRACT

The following case report shows a young male patient with a complex pelvic trauma due to a traffic accident. In addition to the pelvic ring fracture, he also suffered a severe accompanying injury to the efferent urinary tract in combination with extensive damage of the lumbosacral plexus. Multiple extensive operations were necessary to address the C3 fracture of the pelvic ring and the bladder injury. Due to an infection a wound healing disorder subsequently occurred, which necessitated a myocutaneous flap plasty. This case highlights the complexity of this injury and confirms the necessity for an interdisciplinary individualized treatment.


Subject(s)
Abdominal Injuries , Fractures, Bone , Pelvic Bones , Urinary Tract , Humans , Male , Fractures, Bone/complications , Pelvis/diagnostic imaging , Pelvic Bones/diagnostic imaging , Abdominal Injuries/complications
4.
Am J Sports Med ; 44(3): 708-14, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26747848

ABSTRACT

BACKGROUND: Little scientific evidence regarding reverse Hill-Sachs lesions (RHSLs) in posterior shoulder instability exists. Recently, standardized measurement methods of the size and localization were introduced, and the biomechanical effect of the extent and position of the defects on the risk of re-engagement was determined. PURPOSE: To analyze the characteristics and patterns of RHSLs in a large case series using standardized measurements and to interpret the results based on the newly available biomechanical findings. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: In this multicenter study, 102 cases of RHSLs in 99 patients were collected from 7 different shoulder centers between 2004 and 2013. Patient- as well as injury-specific information was gathered, and defect characteristics in terms of the size, localization, and depth index were determined on computed tomography or magnetic resonance imaging scans by means of standardized measurements. Additionally, the position (gamma angle) of the posterior defect margin as a predictor of re-engagement was analyzed. RESULTS: Three types of an RHSL were distinguished based on the pathogenesis and chronicity of the lesion: dislocation (D), locked dislocation (LD), and chronic locked dislocation (CLD). While the localization of the defects did not vary significantly between the subgroups (P = .072), their mean size differed signficantly (D: 32.6° ± 11.7°, LD: 49.4° ± 17.2°, CLD: 64.1° ± 20.7°; P < .001). The mean gamma angle as a predictor of re-engagement was similarly significantly different between groups (D: 83.8° ± 14.5°, LD: 96.5° ± 17.9°, CLD: 108.7° ± 18.4°; P < .001). The orientation of the posterior defect margin was consistently quite parallel to the humeral shaft axis, with a mean difference of 0.3° ± 8.1°. CONCLUSION: The distinction between the 3 different RHSL types based on the pathogenesis and chronicity of the defect helps identify defects prone to re-engagement. The gamma angle as a measurement of the position of the posterior defect margin and therefore a predictor of re-engagement varies significantly between the defect types.


Subject(s)
Humerus/diagnostic imaging , Joint Instability/diagnostic imaging , Shoulder Dislocation/diagnostic imaging , Shoulder Fractures/diagnostic imaging , Shoulder Joint/diagnostic imaging , Adult , Biomechanical Phenomena , Female , Humans , Humerus/pathology , Joint Instability/etiology , Joint Instability/pathology , Male , Middle Aged , Recurrence , Shoulder/diagnostic imaging , Shoulder Dislocation/complications , Shoulder Dislocation/pathology , Shoulder Fractures/complications , Shoulder Fractures/pathology , Shoulder Joint/pathology , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...