Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Nucl Cardiol ; 28(6): 2992-3003, 2021 12.
Article in English | MEDLINE | ID: mdl-32737839

ABSTRACT

BACKGROUND: The diagnosis of cardiac implantable electronic device (CIED) infection is challenging because of its variable presentations. We studied the value of 2-[18F]fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in the detection of CIED infection. METHODS AND RESULTS: Thirty patients with suspected CIED infection underwent 18F-FDG-PET/CT. The control group was ten patients with asymptomatic CIED who underwent cancer-related 18F-FDG-PET/CT. 18F-FDG-PET/CT was evaluated visually, semiquantitatively as maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR). Final diagnosis of CIED infection was based on clinical and bacteriological data. 18F-FDG-PET/CT was visually positive in all 9 patients with recent (≤ 8 weeks) implantation of CIED, but only 4 had confirmed CIED infection. 18F-FDG-PET/CT was true positive in 9 out of 21 cases with remote implantation of CIED and false positive in 3 (14.3%) cases. 18F-FDG-PET/CT was also false positive in 3 (30%) cases of control group. The SUVmax of the pocket area was significantly higher in patients with CIED infection than in the control group (4.8 ± 2.4 vs 2.0 ± .8, P < .001). By using the cut-off value of TBR ≥ 1.8, sensitivity of 18F-FDG-PET/CT for the diagnosis of CIED infection in patients with remote implantation was 90% and specificity 73%, PPV 75%, and NPV 89%. CONCLUSIONS: 18F-FDG-PET/CT is a sensitive but nonspecific method in the diagnosis of CIED infection.


Subject(s)
Defibrillators, Implantable/adverse effects , Fluorodeoxyglucose F18 , Pacemaker, Artificial/adverse effects , Positron Emission Tomography Computed Tomography/methods , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/etiology , Radiopharmaceuticals , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Prospective Studies
2.
Case Rep Cardiol ; 2020: 4921380, 2020.
Article in English | MEDLINE | ID: mdl-33294230

ABSTRACT

Diagnosis of Candida spp. infective endocarditis (IE) is challenging, and diagnostic delays are common. We describe two patients with Candida spp. prosthetic valve endocarditis (PVE) and 18fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT) as a part of diagnostic workup. We also refer to 5 other cases we found from the published literature. These cases highlight that 18F-FDG-PET/CT can improve diagnostic accuracy in prosthetic valve Candida endocarditis.

3.
J Nucl Cardiol ; 24(1): 195-206, 2017 02.
Article in English | MEDLINE | ID: mdl-26662063

ABSTRACT

BACKGROUND: The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[18F]fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. METHODS: Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18F-FDG-PET/CT. 18F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUVmax) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. RESULTS: There was strong, focal 18F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUVmax of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. CONCLUSIONS: 18F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.


Subject(s)
Endocarditis/diagnostic imaging , Fluorodeoxyglucose F18 , Heart Valve Diseases/diagnostic imaging , Heart Valve Prosthesis/adverse effects , Positron Emission Tomography Computed Tomography/methods , Prosthesis-Related Infections/diagnostic imaging , Aged , Endocarditis/etiology , Female , Heart Valve Diseases/etiology , Humans , Male , Middle Aged , Prosthesis-Related Infections/etiology , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...