Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Scand J Med Sci Sports ; 26(9): 1109-16, 2016 Sep.
Article in English | MEDLINE | ID: mdl-26369504

ABSTRACT

The pelvic floor (PF) provides support to all pelvic organs, as well as appropriately closure/opening mechanism of the urethra, vagina, and anus. Therefore, it is likely that female athletes involved in high-impact and in strong-effort activities are at risk for the occurrence of urinary incontinence (UI). This study aimed to investigate the occurrence of UI and other PF dysfunctions (PFD) [anal incontinence (AI), symptoms of constipation, dyspareunia, vaginal laxity, and pelvic organ prolapse] in 67 amateur athletes (AT) compared with a group 96 of nonathletes (NAT). An ad hoc survey based on questions from reliable and valid instruments was developed to investigate the occurrence of PFD symptoms. The risk of UI was higher in AT group (odds ratio: 2.90; 95% CI: 1.50-5.61), mostly among artistic gymnastics and trampoline, followed by swimming and judo athletes. Whereas, AT group reported less straining to evacuate (OR: 0.46; 95% CI: 0.22-0.96), manual assistance to defecate (OR: 0.24; 95% CI: 0.05-1.12), and a higher stool frequency (OR: 0.29; 95% CI: 0.13-0.64) than NAT group. The occurrence of loss of gas and sexual symptoms was high for both groups when compared with literature, although with no statistical difference between them. Pelvic organ prolapse was only reported by nonathletes. Athletes are at higher risk to develop UI, loss of gas, and sexual dysfunctions, either practicing high-impact or strong-effort activities. Thus, pelvic floor must be considered as an entity and addressed as well. Also, women involved in long-term high-impact and strengthening sports should be advised of the impact of such activities on pelvic floor function and offered preventive PFD strategies as well.


Subject(s)
Constipation/epidemiology , Dyspareunia/epidemiology , Fecal Incontinence/epidemiology , Pelvic Organ Prolapse/epidemiology , Sports/statistics & numerical data , Urinary Incontinence/epidemiology , Adolescent , Adult , Brazil/epidemiology , Cross-Sectional Studies , Female , Gymnastics/statistics & numerical data , Health Surveys , Humans , Martial Arts/statistics & numerical data , Swimming/statistics & numerical data , Volleyball/statistics & numerical data , Young Adult
2.
J Vasc Interv Radiol ; 6(3): 379-85, 1995.
Article in English | MEDLINE | ID: mdl-7647439

ABSTRACT

PURPOSE: The ability of three different intravascular stents (Gianturco-Roubin, Palmaz-Schatz, and CV Rad), and two different metals (stainless steel and tantalum) to resist vasoconstriction was evaluated in an intact artery ex vivo model. MATERIALS AND METHODS: Stents were deployed in 21 rabbit thoracic aortae and five dog carotid arteries, which were constricted with phenylephrine and serotonin, respectively. Vasoconstriction was measured with the use of high-frequency ultrasonic imaging. RESULTS: The maximal vasoconstriction of the control segment was 37.7% +/- 2.6 with rabbit aortae and 36.3% +/- 4.1 with dog carotid arteries, while the average maximal constriction for all segments in which stents were placed was 5.7% +/- 1.1 (P < .01). The maximal constriction of the Gianturco-Roubin stainless steel stent was 9.4% +/- 2.7 versus 7.9% +/- 1.6 with the tantalum version (P = .65). Both designs showed somewhat greater constriction compared with either the Palmaz-Schatz (3.3% +/- 0.9) or the CV Rad (1.4% +/- 1.1) stents. CONCLUSIONS: Although all of the stents tested substantially resist arterial vasoconstrictive forces, the Palmaz-Schatz and CV Rad stents resist vasoconstriction to a greater degree than the Gianturco-Roubin stents. Tantalum and stainless steel stents of the same design (Gianturco-Roubin) appear similar in their ability to resist vasoconstrictive forces.


Subject(s)
Aorta, Thoracic/physiology , Carotid Arteries/physiology , Stents , Vasoconstriction , Animals , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/drug effects , Carotid Arteries/diagnostic imaging , Carotid Arteries/drug effects , Dogs , Dose-Response Relationship, Drug , Elastic Tissue/drug effects , Elastic Tissue/physiology , Equipment Design , Materials Testing , Muscle, Smooth, Vascular/drug effects , Muscle, Smooth, Vascular/physiology , Phenylephrine/administration & dosage , Phenylephrine/pharmacology , Pliability , Rabbits , Regional Blood Flow , Serotonin/administration & dosage , Serotonin/pharmacology , Stainless Steel , Tantalum , Ultrasonography
3.
Chest ; 104(2): 611-2, 1993 Aug.
Article in English | MEDLINE | ID: mdl-8339655

ABSTRACT

Greenfield filter inferior vena caval interruption is an effective approach for pulmonary embolism prophylaxis. Serious complications, however, have been documented following migration of these filters. We report a case of Greenfield filter migration to the right side of the heart. Evaluation of these filters, as well as indications for retrieval, are discussed.


Subject(s)
Foreign-Body Migration , Heart , Vena Cava Filters/adverse effects , Aged , Echocardiography , Female , Follow-Up Studies , Foreign-Body Migration/diagnostic imaging , Humans , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...