1.
Rev. Soc. Esp. Enferm. Nefrol ; 13(3): 168-172, jul.-sept. 2010. tab, ilus
Article in Spanish | IBECS | ID: ibc-81555

ABSTRACT

Los pacientes en hemodiálisis tienen cada vez una edad más avanzada y esto hace que aumente el número de complicaciones en su acceso vascular. Las infecciones de los catéteres tunelizados provocan una alta morbi-mortalidad. El dispositivo conector de sellado microbiológica y mecánicamente TEGO® se utiliza en sustitución del tapón convencional con el que se cierran las luces del catéter presentando la ventaja de que sólo se cambia una vez a la semana. Esto hace que al existir menos manipulación de la vía central aparezcan menos complicaciones e infecciones. Además ofrece una doble barrera de seguridad a la entrada de aire y salida de sangre representadas por la pinza del catéter y el tapón. Para evaluar este dispositivo hemos realizado un estudio en el cual comparamos los tapones TEGO® con los tapones convencionales, analizando los siguientes aspectos: presiones del circuito, eficacia dialítica e infecciones del catéter. El estudio tuvo una duración de dos meses y en él participaron doce pacientes portadores de catéter tunelizado. Nuestros resultados indican que no existen diferencias significativas en cuanto a las presiones del circuito y a la eficacia dialítica entre ambos tipos de tapones. Durante el estudio no hubo ninguna infección pericatéter. Creemos que el dispositivo TEGO® por sus especiales características, puede ser el sistema de cierre ideal para todo tipo de catéteres (AU)


Patients on haemodialysis are becoming increasingly older and this means there is an increase in the number of vascular access complications. Infections of tunnelled catheters cause a high morbidity/mortality. The TEGO® microbiologically and mechanically sealed connector is used instead of the conventional cap used to close the catheter ends, and has the advantage that it is only changed once a week. This means that as there is less handling of the central venous catheter, fewer complications and infections appear. It also offers a double security barrier against the entry of air and exit of blood represented by the catheter clamp and the cap. To evaluate this device, we have carried out a study in which we compared the TEGO® connectors with conventional caps, analysing the following aspects: circuit pressures, dialysis efficacy and catheter infections. The study lasted for two months and included the participation of twelve patients using a tunnelled catheter. Our results show that there are no significant differences with regard to circuit pressures and dialysis efficacy between the two different types of caps. During the study there was no pericatheter infection. We believe that the TEGO® device, on account of its special characteristics, may be the ideal closure system for all kind of catheters (AU)


Subject(s)
Humans , Male , Female , Catheterization/instrumentation , Catheterization/methods , Renal Dialysis/methods , Catheter Ablation/instrumentation , Catheter Ablation/methods , Renal Insufficiency, Chronic/diagnosis , Catheterization/trends , Catheterization , Renal Dialysis/trends , Renal Dialysis , Infections/complications , Infections/diagnosis , Data Collection/instrumentation , Data Collection/methods , Catheter Ablation/trends
SELECTION OF CITATIONS
SEARCH DETAIL
...