1.
Ann Emerg Med ; 78(4): 517-529, 2021 10.
Article in English | MEDLINE | ID: mdl-34172301

ABSTRACT

STUDY OBJECTIVE: Ventricular paced rhythm is thought to obscure the electrocardiographic diagnosis of acute coronary occlusion myocardial infarction. Our primary aim was to compare the sensitivity of the modified Sgarbossa criteria (MSC) to that of the original Sgarbossa criteria for the diagnosis of occlusion myocardial infarction in patients with ventricular paced rhythm. METHODS: In this retrospective case-control investigation, we studied adult patients with ventricular paced rhythm and symptoms of acute coronary syndrome who presented in an emergency manner to 16 international cardiac referral centers between January 2008 and January 2018. The occlusion myocardial infarction group was defined angiographically as thrombolysis in myocardial infarction grade 0 to 1 flow or angiographic evidence of coronary thrombosis and peak cardiac troponin I ≥10.0 ng/mL or troponin T ≥1.0 ng/mL. There were 2 control groups: the "non-occlusion myocardial infarction-angio" group consisted of patients who underwent coronary angiography for presumed type I myocardial infarction but did not meet the definition of occlusion myocardial infarction; the "no occlusion myocardial infarction" control group consisted of randomly selected emergency department patients without occlusion myocardial infarction. RESULTS: There were 59 occlusion myocardial infarction, 90 non-occlusion myocardial infarction-angio, and 102 no occlusion myocardial infarction subjects (mean age, 72.0 years; 168 [66.9%] men). For the diagnosis of occlusion myocardial infarction, the MSC were more sensitive than the original Sgarbossa criteria (sensitivity 81% [95% confidence interval [CI] 69 to 90] versus 56% [95% CI 42 to 69]). Adding concordant ST-depression in V4 to V6 to the MSC yielded 86% (95% CI 75 to 94) sensitivity. For the no occlusion myocardial infarction control group of ED patients, additional test characteristics of MSC and original Sgarbossa criteria, respectively, were as follows: specificity 96% (95% CI 90 to 99) versus 97% (95% CI 92 to 99); negative likelihood ratio (LR) 0.19 (95% CI 0.11 to 0.33) versus 0.45 (95% CI 0.34 to 0.65); and positive LR 21 (95% CI 7.9 to 55) versus 19 (95% CI 6.1 to 59). For the non-occlusion myocardial infarction-angio control group, additional test characteristics of MSC and original Sgarbossa criteria, respectively, were as follows: specificity 84% (95% CI 76 to 91) versus 90% (95% CI 82 to 95); negative LR 0.22 (95% CI 0.13 to 0.38) versus 0.49 (95% CI 0.35 to 0.66); and positive LR 5.2 (95% CI 3.2 to 8.6) versus 5.6 (95% CI 2.9 to 11). CONCLUSION: For the diagnosis of occlusion myocardial infarction in the presence of ventricular paced rhythm, the MSC were more sensitive than the original Sgarbossa criteria; specificity was high for both rules. The MSC may contribute to clinical decisionmaking for patients with ventricular paced rhythm.


Subject(s)
Acute Coronary Syndrome/diagnostic imaging , Clinical Decision-Making , Coronary Occlusion/diagnostic imaging , Electrocardiography , Myocardial Infarction/diagnostic imaging , Aged , Aged, 80 and over , Case-Control Studies , Coronary Angiography , Decision Support Techniques , Female , Humans , Male , Retrospective Studies
2.
Resuscitation ; 148: 32-38, 2020 03 01.
Article in English | MEDLINE | ID: mdl-31962176

ABSTRACT

AIM OF THE STUDY: Negative intrathoracic pressure (ITP) during the decompression phase of cardiopulmonary resuscitation (CPR) is essential to refill the heart, increase cardiac output, maintain cerebral and coronary perfusion pressures, and improve survival. In order to generate negative ITP, an airway seal is necessary. We tested the hypothesis that some supraglottic airway (SGA) devices do not seal the airway as well the standard endotracheal tube (ETT). METHODS: Airway pressures (AP) were measured as a surrogate for ITP in seven recently deceased human cadavers of varying body habitus. Conventional manual, automated, and active compression-decompression CPR were performed with and without an impedance threshold device (ITD) in supine and Head Up positions. Positive pressure ventilation was delivered by an ETT and 5 SGA devices tested in a randomized order in this prospective cross-over designed study. The primary outcome was comparisons of decompression AP between all groups. RESULTS: An ITD was required to generate significantly lower negative ITP during the decompression phase of all methods of CPR. SGAs varied in their ability to support negative ITP. CONCLUSION: In a human cadaver model, the ability to generate negative intrathoracic pressures varied with different SGAs and an ITD regardless of the body position or CPR method. Differences in SGAs devices should be strongly considered when trying to optimize cardiac arrest outcomes, as some SGAs do not consistently develop a seal or negative intrathoracic pressure with multiple different CPR methods and devices.


Subject(s)
Cardiopulmonary Resuscitation , Heart Arrest , Cadaver , Cross-Over Studies , Heart Arrest/therapy , Humans , Prospective Studies
3.
Resuscitation ; 121: 195-200, 2017 12.
Article in English | MEDLINE | ID: mdl-28827197

ABSTRACT

AIM OF THE STUDY: As most cardiopulmonary resuscitation (CPR) efforts last longer than 15min, the aim of this study was to compare brain blood flow between the Head Up (HUP) and supine (SUP) body positions during a prolonged CPR effort of 15min, using active compression-decompression (ACD) CPR and impedance threshold device (ITD) in a swine model of cardiac arrest. METHODS: Ventricular fibrillation (VF) was induced in anesthetized pigs. After 8min of untreated VF followed by 2min of ACD-CPR+ITD in the SUP position, pigs were randomized to 18min of continuous ACD-CPR+ITD in either a 30° HUP or SUP position. Microspheres were injected before VF and then 5 and 15min after start of CPR. RESULTS: The mean blood flow (ml/min/g, mean±SD) to the brain after 15min of CPR was 0.42±0.05 in the HUP group (n=8) and 0.21±0.04 SUP (n=10), respectively, (p<0.01). The HUP group also had statistically significantly lower intracranial pressures and higher calculated cerebral perfusion pressures after 5, 15, 19 (before adrenaline) and 20 (after adrenaline) minutes of HUT versus SUP CPR. CONCLUSIONS: After prolonged ACD-CPR+ITD in the HUP position, brain blood flow was 2-fold higher versus the SUP position. These positive findings provide strong pre-clinical support to proceed with a clinical evaluation of elevation of the head and thorax during ACD-CPR+ITD in humans in cardiac arrest.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Cerebrovascular Circulation/physiology , Heart Arrest/physiopathology , Heart Arrest/therapy , Hemodynamics/physiology , Posture , Animals , Brain/physiopathology , Disease Models, Animal , Head , Humans , Random Allocation , Swine , Thorax , Time Factors
4.
Resuscitation ; 119: 81-88, 2017 10.
Article in English | MEDLINE | ID: mdl-28800887

ABSTRACT

AIM OF THE STUDY: The purpose of this study was to examine continuous oxygen insufflation (COI) in a swine model of cardiac arrest. The primary hypothesis was COI during standard CPR (S-CPR) should result in higher intrathoracic pressure (ITP) during chest compression and lower ITP during decompression versus S-CPR alone. These changes with COI were hypothesized to improve hemodynamics. The second hypothesis was that changes in ITP with S-CPR+COI would result in superior hemodynamics compared with active compression decompression (ACD) + impedance threshold device (ITD) CPR, as this method primarily lowers ITP during chest decompression. METHODS: After 6min of untreated ventricular fibrillation, S-CPR was initiated in 8 female swine for 4min, then 3min of S-CPR+COI, then 3min of ACD+ITD CPR, then 3min of S-CPR+COI. ITP and hemodynamics were continuously monitored. RESULTS: During S-CPR+COI, ITP was always positive during the CPR compression and decompression phases. ITP compression values with S-CPR+COI versus S-CPR alone were 5.5±3 versus 0.2±2 (p<0.001) and decompression values were 2.8±2 versus -1.3±2 (p<0.001), respectively. With S-CPR+COI versus ACD+ITD the ITP compression values were 5.5±3 versus 1.5±2 (p<0.01) and decompression values were 2.8±2 versus -4.7±3 (p<0.001), respectively. CONCLUSION: COI during S-CPR created a continuous positive pressure in the airway during both the compression and decompression phase of CPR. At no point in time did COI generate a negative intrathoracic pressures during CPR in this swine model of cardiac arrest.


Subject(s)
Continuous Positive Airway Pressure , Heart Arrest/therapy , Heart Massage/methods , Insufflation/methods , Intubation, Intratracheal/instrumentation , Ventricular Fibrillation/therapy , Animals , Blood Gas Analysis , Cardiopulmonary Resuscitation/adverse effects , Cardiopulmonary Resuscitation/methods , Disease Models, Animal , Female , Heart Arrest/physiopathology , Intubation, Intratracheal/adverse effects , Swine
5.
Resuscitation ; 116: 56-59, 2017 07.
Article in English | MEDLINE | ID: mdl-28461164

ABSTRACT

INTRODUCTION: Chest compliance plays a fundamental role in the generation of circulation during cardiopulmonary resuscitation (CPR). To study potential changes in chest compliance over time, anterior posterior (AP) chest height measurements were performed on newly deceased (never frozen) human cadavers during CPR before and after 5min of automated CPR. We tested the hypothesis that after 5min of CPR chest compliance would be significantly increased. METHODS: Static compression (30, 40, and 50kg) and decompression forces (-10, -15kg) were applied with a manual ACD-CPR device (ResQPUMP, ZOLL) before and after 5min of automated CPR. Lateral chest x-rays were obtained with multiple reference markers to assess changes in AP distance. RESULTS: In 9 cadavers, changes (mean±SD) in the AP distance (cm) during the applied forces were 2.1±1.2 for a compression force of 30kg, 2.9±1.3 for 40kg, 4.3±1.0 for 50kg, 1.0±0.8 for a decompression force of -10kg and 1.8±0.6 for -15kg. After 5min of automated CPR, AP excursion distances were significantly greater (p<0.05). AP distance increased to 3.7±1.4 for a compression force of 30kg, 4.9±1.6 for 40kg, 6.3±1.9 for 50kg, 2.3±0.9 for -10kg of lift and 2.7±1.1 for -15kg of lift. CONCLUSIONS: These data demonstrate chest compliance increases significantly over time as demonstrated by the significant increase in the measured AP distance after 5min of CPR. These findings suggest that adjustments in compression and decompression forces may be needed to optimize CPR over time.


Subject(s)
Cardiopulmonary Resuscitation/instrumentation , Decompression , Lung Compliance/physiology , Pressure , Cadaver , Female , Heart Arrest/therapy , Humans , Male , Thoracic Wall/physiopathology