Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Cureus ; 14(4): e24054, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35573526

ABSTRACT

Transcatheter aortic valve replacement (TAVR) is a technique that can be performed through multiple approaches, and the benefits of one approach over another are still being evaluated to make sure patients receive the best possible care. Our meta-analysis aims to compare clinical and procedural outcomes of the transaxillary (TAx) and transaortic (TAo) approaches to validate the more optimal procedure. The systematic literature search was done via PubMed/MEDLINE, Embase, and the Cochrane Central databases from inception to December 2021, to identify articles reporting data on both TAx TAVR and TAo TAVR. In addition, we checked ClinicalTrials.gov for more published or unpublished trials. Baseline patient characteristics, procedure results, and clinical results were extracted from the article and pooled for analysis. A quantitative meta-analysis was conducted using Review Manager (RevMan) version 5.3 (Nordic Cochrane Centre, The Cochrane Collaboration, Copenhagen, Denmark). The outcomes extracted included blood transfusion, conversion to sternotomy, tamponade, contrast amount, procedure time, bleeding incidents (minor, major, or life-threatening), length of stay (LOS), vascular complications (minor or major), acute kidney injury (AKI), paravalvular leak (PVL), permanent pacemaker (PPM) implantation, 30-day mortality, one-year mortality, 30-day stroke, and device success. The final analysis included 11 articles, consisting of 10 observational studies and a pivotal trial. Cumulative results revealed that the TAo approach had a significantly lower incidence of vascular complications (RR = 2.30; 95% CI = 1.22 to 4.35), and the need for implantation of a permanent pacemaker (RR = 1.82; 95% CI = 1.30 to 2.54) along with a lower amount of contrast (mean difference (MD) = 27.40; 95% CI = 3.73 to 51.08) needed to be used. The TAx group was associated with a significantly lower 30-day mortality (RR = 0.46; 95% CI = 0.31 to 0.69), AKI (RR = 0.47; 95% CI = 0.33 to 0.67), and length of hospital stay (MD = -1.95; 95% CI = -2.51 to -1.38). No significant difference was observed between the outcomes of 30-day stroke (RR = 1.38; 95% CI = 0.81 to 2.33), PVL (RR = 1.05; 95% CI = 0.50 to 2.18), tamponade (RR = 0.71; 95% CI = 0.12 to 4.03), conversion to sternotomy (RR = 0.51; 95% CI = 0.06 to 4.30), device success (RR = 0.97; 95% CI = 0.88 to 1.07), the incidence of bleeding (RR = 0.75; 95% CI = 0.51 to 1.10), and procedure time (MD = 4.44; 95% CI = -96.30 to 105.17). Both the procedures were associated with their benefits and risks. Although most of the outcomes favored TAx transcatheter aortic valve implantation (TAVI), it is too early to say if it would be better than TAo TAVI. To authenticate the findings concluded in this meta-analysis and further improve our understanding of the efficacy, safety, and risk profile between TAx and TAo approaches for TAVI, large sample randomized clinical trials are required on a wide scale.

2.
Cureus ; 10(6): e2858, 2018 Jun 22.
Article in English | MEDLINE | ID: mdl-30148011

ABSTRACT

BACKGROUND: Rheumatic diseases are referred to as conditions affecting joints, muscles, ligaments, tendons, and bones. According to a report by World Health Organization, rheumatic and musculoskeletal diseases were labeled as the second most reported cause of disability around the globe. The purpose of this study was to estimate the prevalence of rheumatic diseases in a tertiary care hospital of Karachi; additionally, associations with age groups, gender and comorbidities were obtained as well. METHODS: A cross-sectional study was conducted at the Orthopedic Out Patient Department (OPD) of Dr. Ruth KM Pfau Civil Hospital, Karachi over a span of three months in 2018 (February till May). All 346 patients were follow-up diagnosed cases in the age range of 11-90 years, divided into groups of adolescents, young adults, adults, and older adults. The subjects were questioned about their symptoms, duration of illness, presence of comorbidities, genetic background and the therapy they are undergoing along with compliance. Simple statistical analysis of frequency was done, whereas chi-square test was applied to study associations with gender, age groups, and comorbidities. RESULTS: During the study period, a total of 2000 patients visited the orthopedic OPD, 346 of which were diagnosed cases of rheumatic diseases, yielding a prevalence of 17.3%. The mean age of rheumatic patients who partook in the study was 46.15 ± 15.49 (Range: 12 - 84). Osteoarthritis was recorded as the most prevalent condition, followed by non-specific low back pain and rheumatoid arthritis. Osteoarthritis was statistically significant in young adults, adults, and older adults, while non-specific low back pain had significant associations with gender, young adults, and adults. Diabetes was significantly associated with osteoarthritis, non-specific low back pain, shoulder pain syndrome and psoriatic arthritis, while hypertension significantly co-existed with systemic lupus erthematosus. CONCLUSION: Rheumatic diseases constitute a major disease burden in almost all of the age groups, especially in young patients (18-40 years) within our setup.

3.
Nature ; 544(7649): 207-211, 2017 04 13.
Article in English | MEDLINE | ID: mdl-28355177

ABSTRACT

Transient control over the atomic potential-energy landscapes of solids could lead to new states of matter and to quantum control of nuclear motion on the timescale of lattice vibrations. Recently developed ultrafast time-resolved diffraction techniques combine ultrafast temporal manipulation with atomic-scale spatial resolution and femtosecond temporal resolution. These advances have enabled investigations of photo-induced structural changes in bulk solids that often occur on timescales as short as a few hundred femtoseconds. In contrast, experiments at surfaces and on single atomic layers such as graphene report timescales of structural changes that are orders of magnitude longer. This raises the question of whether the structural response of low-dimensional materials to femtosecond laser excitation is, in general, limited. Here we show that a photo-induced transition from the low- to high-symmetry state of a charge density wave in atomic indium (In) wires supported by a silicon (Si) surface takes place within 350 femtoseconds. The optical excitation breaks and creates In-In bonds, leading to the non-thermal excitation of soft phonon modes, and drives the structural transition in the limit of critically damped nuclear motion through coupling of these soft phonon modes to a manifold of surface and interface phonons that arise from the symmetry breaking at the silicon surface. This finding demonstrates that carefully tuned electronic excitations can create non-equilibrium potential energy surfaces that drive structural dynamics at interfaces in the quantum limit (that is, in a regime in which the nuclear motion is directed and deterministic). This technique could potentially be used to tune the dynamic response of a solid to optical excitation, and has widespread potential application, for example in ultrafast detectors.

SELECTION OF CITATIONS
SEARCH DETAIL
...