Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 36(9): 1165-82, 1991 Sep.
Article in English | MEDLINE | ID: mdl-1946601

ABSTRACT

The influence of anode and filter materials on the performance (image quality and dose) of a mammography system is investigated. The image quality is evaluated with the image quality index method. A computer simulation has been developed to calculate the physical parameters of the image quality index (contrast, resolution and noise) as well as the mean glandular dose. The calculations take into account the successive steps of the process: x-ray production, filtration, interaction with the test object, anti-scatter grid, interaction with the image detector (screen-film system). An excellent correlation is obtained between the results predicted by the model and those of experimental measurements, suggesting that the model may be used for the prediction of the performance of mammographic equipment. The experimental conclusions are confirmed: the use of a tungsten anode with a rhodium filter allows a dose reduction without a significant degradation of image quality. The computer program can also be used to simulate the influence of factors which are difficult to combine in practice, e.g., various anode and filter materials, monoenergetic x-rays, etc.


Subject(s)
Electrodes , Filtration/instrumentation , Mammography/instrumentation , X-Ray Intensifying Screens , Molybdenum , Radiation Dosage , Rhodium , Tungsten
2.
Phys Med Biol ; 36(1): 19-33, 1991 Jan.
Article in English | MEDLINE | ID: mdl-2006213

ABSTRACT

A suitable quantity for evaluating the image quality in mammography is the smallest visible size of an object. This quantity, called the image quality index (IQI), can be derived from the basic image parameters: contrast, MTF, Wiener spectrum. Several evaluation methods of the IQI, all based on statistical decision theory, have been considered. An experimental visibility test using simulated microcalcifications has been performed in order to compare the results obtained with different IQI models. A previous approach, based on simplifying assumptions, yields a good correlation with the visibility test but fails to predict the actual size of the visible objects. Improved models have been derived for an ideal observer and for a 'quasi-ideal' one with perfect or with realistic visual characteristics. The experimental visual results are well modelled by the IQI method, provided that a suitable threshold signal-to-noise ratio is used for each of these models.


Subject(s)
Mammography/standards , Quality Assurance, Health Care , Weights and Measures , X-Ray Intensifying Screens/standards , Animals , Cricetinae , Female , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...