Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Lett ; 49(6): 1457-1460, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38489424

ABSTRACT

The transient dynamics of photothermal signals provide interesting insights into material properties and heat diffusion. In a mid-infrared (mid-IR) photothermal microscope, the imaging contrast in a standard amplitude imaging can decrease due to thermal diffusion effects. It is shown that contrast varies for poly-methyl 2-methylpropenoate (PMMA) particles of different sizes when embedded in an absorbing medium of water (H2O) based on levels of heat exchange under the water absorption resonance. Using time-resolved boxcar (BC) detection, analysis of the transient thermal dynamics at the bead-water interface is presented, and the time decay parameters for 500 nm and 100 nm beads are determined. Enhanced (negative) imaging contrast is observed for less heat exchange between the water and bead, as in the case for the 100 nm bead. For the 500 nm bead, boxcar imaging before heat exchange starts occurring, leads to an increase of the imaging contrast up to a factor of 1.6.

2.
Anal Chem ; 95(45): 16514-16521, 2023 11 14.
Article in English | MEDLINE | ID: mdl-37880191

ABSTRACT

Few experimental tools exist for performing label-free imaging of biological samples in a water-rich environment due to the high infrared absorption of water, overlapping with major protein and lipid bands. A novel imaging modality based on time-resolved mid-infrared photothermal microscopy is introduced and applied to imaging axon bundles in a saline bath environment. Photothermally induced spatial gradients at the axon bundle membrane interfaces with saline and surrounding biological tissue are observed and temporally characterized by a high-speed boxcar detection system. Localized time profiles with an enhanced signal-to-noise, hyper-temporal image stacks, and two-dimensional mapping of the time decay profiles are acquired without the need for complex post image processing. Axon bundles are found to have a larger distribution of time decay profiles compared to the water background, allowing background differentiation based on these transient dynamics. The quantitative analysis of the signal evolution over time allows characterizing the level of thermal confinement at different regions. When axon bundles are surrounded by complex heterogeneous tissue, which contains smaller features, a stronger thermal confinement is observed compared to a water environment, thus shedding light on the heat transfer dynamics across aqueous biological interfaces.


Subject(s)
Microscopy , Water , Microscopy/methods , Axons , Image Processing, Computer-Assisted , Proteins
3.
J Biol Phys ; 49(3): 365-381, 2023 09.
Article in English | MEDLINE | ID: mdl-37477759

ABSTRACT

An analytical model is presented for light scattering associated with heat transport near a cell membrane that divides a complex system into two topologically distinct half-spaces. Our analysis is motivated by experiments on vibrational photothermal microscopy which have not only demonstrated remarkably high contrast and resolution, but also are capable of providing label-free local information of heat transport in complex morphologies. In the first Born approximation, the derived Green's function leads to the reconstruction of a full 3D image with photothermal contrast obtained using both amplitude and phase detection of periodic excitations. We show that important fundamental parameters including the Kapitza length and Kapitza resistance can be derived from experiments. Our goal is to spur additional experimental studies with high-frequency modulation and heterodyne detection in order to make contact with recent theoretical molecular dynamics calculations of thermal transport properties in membrane systems.


Subject(s)
Microscopy , Molecular Dynamics Simulation , Hot Temperature
5.
Biomed Opt Express ; 12(1): 303-319, 2021 Jan 01.
Article in English | MEDLINE | ID: mdl-33520386

ABSTRACT

Label-free vibrational imaging of biological samples has attracted significant interest due to its integration of structural and chemical information. Vibrational infrared photothermal amplitude and phase signal (VIPPS) imaging provide label-free chemical identification by targeting the characteristic resonances of biological compounds that are present in the mid-infrared fingerprint region (3 µm - 12 µm). High contrast imaging of subcellular features and chemical identification of protein secondary structures in unlabeled and labeled fibroblast cells embedded in a collagen-rich extracellular matrix is demonstrated by combining contrast from absorption signatures (amplitude signals) with sensitive detection of different heat properties (lock-in phase signals). We present that the detectability of nano-sized cell membranes is enhanced to well below the optical diffraction limit since the membranes are found to act as thermal barriers. VIPPS offers a novel combination of chemical imaging and thermal diffusion characterization that paves the way towards label-free imaging of cell models and tissues as well as the study of intracellular heat dynamics.

6.
J Endourol ; 34(6): 682-686, 2020 06.
Article in English | MEDLINE | ID: mdl-32216458

ABSTRACT

Introduction: Flexible ureteroscopy is a mainstay of upper urinary tract stone treatment. Holmium laser lithotripsy is a particularly common and notable technique for the dusting and fragmenting of renal stones. During ureteroscopy, optical fibers are subject to sharp bends in pursuit of stones, particularly those at the lower pole. Following from principles of fiber optics, subjecting these fibers to sharp bending angle has the potential to reduce the efficiency of power transmission at the fiber tip. Due to the potential implications this hypothesis could have on endourological practice and research, we aimed to explore the potential impact of fiber bending on end-fiber power output. Materials and Methods: Using a highly sensitive oscilloscope and a urological holmium laser, we assessed the end-fiber power output under a variety of bending conditions. To ensure maximal confidence in our results, the maximal bending conditions explored substantially exceeded any condition, which could occur during ureteroscopic surgery. Results: We found evidence that bending radius alone has a clinically insignificant impact on the light power transmission in the fiber. At certain bending conditions, we observed a clinically unimportant but statistically significant reduction in power transmission. This was verified using two commonly used delivery fiber types exposed to 8-second bursts for each bending condition.


Subject(s)
Lasers, Solid-State , Lithotripsy, Laser , Holmium , Humans , Radius , Ureteroscopy
7.
Opt Express ; 27(3): 2643-2655, 2019 Feb 04.
Article in English | MEDLINE | ID: mdl-30732299

ABSTRACT

Imaging of the phase output of a lock-in amplifier in mid-infrared photothermal vibrational microscopy is demonstrated for the first time in combination with nonlinear demodulation. In general, thermal blurring and heat transport phenomena contribute to the resolution and sensitivity of mid-infrared photothermal imaging. For heterogeneous samples with multiple absorbing features, if imaged in a spectral regime of comparable absorption with their embedding medium, it is demonstrated that differentiation with high contrast is achieved in complementary imaging of the phase signal obtained from a lock-in amplifier compared to standard imaging of the photothermal amplitude signal. Specifically, by investigating the relative contribution of the out-of-phase lock-in signal, information based on changes in the rate of heat transport can be extracted, and inhomogeneities in the thermal diffusion properties across the sample plane can be mapped with high sensitivity and sub-diffraction limited resolution. Under these imaging conditions, wavenumber regimes can be identified in which the thermal diffusion contributions are minimized and an enhancement of the spatial resolution beyond the diffraction limited spot size of the probe beam in the corresponding phase images is achieved. By combining relative diffusive phase imaging with nonlinear demodulation at the second harmonic, it is demonstrated that 1-µm-size melamine beads embedded in a thin layer of 4-octyl-4'-cyanobiphenyl (8CB) liquid crystal can be detected with a 1.3-µm spatial full-width at half-maximum (FWHM) resolution. Thus, imaging with a resolving power that exceeds the probe diffraction limited spot size by a factor of 2.5 is presented, which paves the route towards super-resolution, label-free imaging in the mid-infrared.

SELECTION OF CITATIONS
SEARCH DETAIL
...