Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Mult Scler ; 30(4-5): 516-534, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38372019

ABSTRACT

BACKGROUND: We assessed the ability of a brain-and-cord-matched quantitative magnetic resonance imaging (qMRI) protocol to differentiate patients with progressive multiple sclerosis (PMS) from controls, in terms of normal-appearing (NA) tissue abnormalities, and explain disability. METHODS: A total of 27 patients and 16 controls were assessed on the Expanded Disability Status Scale (EDSS), 25-foot timed walk (TWT), 9-hole peg (9HPT) and symbol digit modalities (SDMT) tests. All underwent 3T brain and (C2-C3) cord structural imaging and qMRI (relaxometry, quantitative magnetisation transfer, multi-shell diffusion-weighted imaging), using a fast brain-and-cord-matched protocol with brain-and-cord-unified imaging readouts. Lesion and NA-tissue volumes and qMRI metrics reflecting demyelination and axonal loss were obtained. Random forest analyses identified the most relevant volumetric/qMRI measures to clinical outcomes. Confounder-adjusted linear regression estimated the actual MRI-clinical associations. RESULTS: Several qMRI/volumetric differences between patients and controls were observed (p < 0.01). Higher NA-deep grey matter quantitative-T1 (EDSS: beta = 7.96, p = 0.006; 9HPT: beta = -0.09, p = 0.004), higher NA-white matter orientation dispersion index (TWT: beta = -3.21, p = 0.005; SDMT: beta = -847.10, p < 0.001), lower whole-cord bound pool fraction (9HPT: beta = 0.79, p = 0.001) and higher NA-cortical grey matter quantitative-T1 (SDMT = -94.31, p < 0.001) emerged as particularly relevant predictors of greater disability. CONCLUSION: Fast brain-and-cord-matched qMRI protocols are feasible and identify demyelination - combined with other mechanisms - as key for disability accumulation in PMS.


Subject(s)
Cervical Cord , Multiple Sclerosis, Chronic Progressive , Multiple Sclerosis , Humans , Cervical Cord/pathology , Multiple Sclerosis/pathology , Brain/pathology , Magnetic Resonance Imaging/methods , Multiple Sclerosis, Chronic Progressive/pathology , Gray Matter/pathology
2.
Sci Rep ; 13(1): 6565, 2023 04 21.
Article in English | MEDLINE | ID: mdl-37085693

ABSTRACT

Magnetic resonance neurography (MRN) has been used successfully over the years to investigate the peripheral nervous system (PNS) because it allows early detection and precise localisation of neural tissue damage. However, studies demonstrating the feasibility of combining MRN with multi-parametric quantitative magnetic resonance imaging (qMRI) methods, which provide more specific information related to nerve tissue composition and microstructural organisation, can be invaluable. The translation of emerging qMRI methods previously validated in the central nervous system to the PNS offers real potential to characterise in patients in vivo the underlying pathophysiological mechanisms involved in a plethora of conditions of the PNS. The aim of this study was to assess the feasibility of combining MRN with qMRI to measure diffusion, magnetisation transfer and relaxation properties of the healthy sciatic nerve in vivo using a unified signal readout protocol. The reproducibility of the multi-parametric qMRI protocol as well as normative qMRI measures in the healthy sciatic nerve are reported. The findings presented herein pave the way to the practical implementation of joint MRN-qMRI in future studies of pathological conditions affecting the PNS.


Subject(s)
Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Feasibility Studies , Reproducibility of Results , Magnetic Resonance Imaging/methods , Sciatic Nerve/diagnostic imaging , Magnetic Resonance Spectroscopy
3.
Magn Reson Med ; 88(2): 849-859, 2022 08.
Article in English | MEDLINE | ID: mdl-35476875

ABSTRACT

PURPOSE: Spinal cord gray-matter imaging is valuable for a number of applications, but remains challenging. The purpose of this work was to compare various MRI protocols at 1.5 T, 3 T, and 7 T for visualizing the gray matter. METHODS: In vivo data of the cervical spinal cord were collected from nine different imaging centers. Data processing consisted of automatically segmenting the spinal cord and its gray matter and co-registering back-to-back scans. We computed the SNR using two methods (SNR_single using a single scan and SNR_diff using the difference between back-to-back scans) and the white/gray matter contrast-to-noise ratio per unit time. Synthetic phantom data were generated to evaluate the metrics performance. Experienced radiologists qualitatively scored the images. We ran the same processing on an open-access multicenter data set of the spinal cord MRI (N = 267 participants). RESULTS: Qualitative assessments indicated comparable image quality for 3T and 7T scans. Spatial resolution was higher at higher field strength, and image quality at 1.5 T was found to be moderate to low. The proposed quantitative metrics were found to be robust to underlying changes to the SNR and contrast; however, the SNR_single method lacked accuracy when there were excessive partial-volume effects. CONCLUSION: We propose quality assessment criteria and metrics for gray-matter visualization and apply them to different protocols. The proposed criteria and metrics, the analyzed protocols, and our open-source code can serve as a benchmark for future optimization of spinal cord gray-matter imaging protocols.


Subject(s)
Cervical Cord , White Matter , Gray Matter/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Multicenter Studies as Topic , Spinal Cord/diagnostic imaging , White Matter/diagnostic imaging
4.
Neurology ; 98(17): e1783-e1793, 2022 04 26.
Article in English | MEDLINE | ID: mdl-35277438

ABSTRACT

BACKGROUND AND OBJECTIVE: To explore the relationship between slowly expanding lesions (SELs) on MRI and disability in secondary progressive multiple sclerosis (SPMS). METHODS: We retrospectively studied 345 patients with SPMS enrolled in the MS-SMART trial. They underwent brain MRI at baseline and at 24 and 96 weeks. Definite SELs were defined as concentrically expanding T2 lesions, as assessed by nonlinear deformation of volumetric T1-weighted images. Associations of SEL volumes with other MRI metrics and disability were assessed through Pearson correlations and regression analyses. RESULTS: Averaged across patients, 29% of T2 lesions were classified as being definite SELs. A greater volume of definite SELs correlated with a higher total baseline T2 lesion volume (r = 0.55, p < 0.001) and percentage brain volume reduction (r = -0.26, p < 0.001), a higher number of new persisting T1 black holes (r = 0.19, p < 0.001), and, in a subset of 106 patients, with a greater reduction in magnetization transfer ratio (adjusted difference 0.52, p < 0.001). In regression analyses, a higher definite SEL volume was associated with increasing disability, as assessed by the Expanded Disability Status Scale (ß = 0.23, p = 0.020), z scores of the Multiple Sclerosis Functional Composite (ß = -0.47, p = 0.048), Timed 25-Foot Walk Test (ß = -2.10, p = 0.001), and Paced Auditory Serial Addition Task (ß = -0.27, p = 0.006), and increased risk of disability progression (odds ratio 1.92, p = 0.025). DISCUSSION: Definite SELs represent almost one-third of T2 lesions in SPMS. They are associated with neurodegenerative MRI markers and related to clinical worsening, suggesting that they may contribute to disease progression and be a new target for therapeutic interventions.


Subject(s)
Multiple Sclerosis, Chronic Progressive , Multiple Sclerosis , Brain/pathology , Humans , Magnetic Resonance Imaging/methods , Multiple Sclerosis, Chronic Progressive/complications , Multiple Sclerosis, Chronic Progressive/diagnostic imaging , Multiple Sclerosis, Chronic Progressive/drug therapy , Retrospective Studies
5.
Front Neurol ; 12: 763143, 2021.
Article in English | MEDLINE | ID: mdl-34899579

ABSTRACT

Background: Multiple sclerosis (MS) has traditionally been regarded as a disease confined to the central nervous system (CNS). However, neuropathological, electrophysiological, and imaging studies have demonstrated that the peripheral nervous system (PNS) is also involved, with demyelination and, to a lesser extent, axonal degeneration representing the main pathophysiological mechanisms. Aim: The purpose of this study was to assess PNS damage at the lumbar plexus and sciatic nerve anatomical locations in people with relapsing-remitting MS (RRMS) and healthy controls (HCs) in vivo using magnetisation transfer ratio (MTR), which is a known imaging biomarker sensitive to alterations in myelin content in neural tissue, and not previously explored in the context of PNS damage in MS. Method: Eleven HCs (7 female, mean age 33.6 years, range 24-50) and 15 people with RRMS (12 female, mean age 38.5 years, range 30-56) were recruited for this study and underwent magnetic resonance imaging (MRI) investigations together with clinical assessments using the expanded disability status scale (EDSS). Magnetic resonance neurography (MRN) was first used for visualisation and identification of the lumbar plexus and the sciatic nerve and MTR imaging was subsequently performed using identical scan geometry to MRN, enabling straightforward co-registration of all data to obtain global and regional mean MTR measurements. Linear regression models were used to identify differences in MTR values between HCs and people with RRMS and to identify an association between MTR measures and EDSS. Results: MTR values in the sciatic nerve of people with RRMS were found to be significantly lower compared to HCs, but no significant MTR changes were identified in the lumbar plexus of people with RRMS. The median EDSS in people with RRMS was 2.0 (range, 0-3). No relationship between the MTR measures in the PNS and EDSS were identified at any of the anatomical locations studied in this cohort of people with RRMS. Conclusion: The results from this study demonstrate the presence of PNS damage in people with RRMS and support the notion that these changes, suggestive of demyelination, maybe occurring independently at different anatomical locations within the PNS. Further investigations to confirm these findings and to clarify the pathophysiological basis of these alterations are warranted.

6.
Lancet Neurol ; 20(9): 709-720, 2021 09.
Article in English | MEDLINE | ID: mdl-34418398

ABSTRACT

BACKGROUND: Progressive disability in multiple sclerosis occurs because CNS axons degenerate as a late consequence of demyelination. In animals, retinoic acid receptor RXR-gamma agonists promote remyelination. We aimed to assess the safety and efficacy of a non-selective retinoid X receptor agonist in promoting remyelination in people with multiple sclerosis. METHODS: This randomised, double-blind, placebo-controlled, parallel-group, phase 2a trial (CCMR One) recruited patients with relapsing-remitting multiple sclerosis from two centres in the UK. Eligible participants were aged 18-50 years and had been receiving dimethyl fumarate for at least 6 months. Via a web-based system run by an independent statistician, participants were randomly assigned (1:1), by probability-weighted minimisation using four binary factors, to receive 300 mg/m2 of body surface area per day of oral bexarotene or oral placebo for 6 months. Participants, investigators, and outcome assessors were masked to treatment allocation. MRI scans were done at baseline and at 6 months. The primary safety outcome was the number of adverse events and withdrawals attributable to bexarotene. The primary efficacy outcome was the patient-level change in mean lesional magnetisation transfer ratio between baseline and month 6 for lesions that had a baseline magnetisation transfer ratio less than the within-patient median. We analysed the primary safety outcome in the safety population, which comprised participants who received at least one dose of their allocated treatment. We analysed the primary efficacy outcome in the intention-to-treat population, which comprised all patients who completed the study. This study is registered in the ISRCTN Registry, 14265371, and has been completed. FINDINGS: Between Jan 17, 2017, and May 17, 2019, 52 participants were randomly assigned to receive either bexarotene (n=26) or placebo (n=26). Participants who received bexarotene had a higher mean number of adverse events (6·12 [SD 3·09]; 159 events in total) than did participants who received placebo (1·63 [SD 1·50]; 39 events in total). All bexarotene-treated participants had at least one adverse event, which included central hypothyroidism (n=26 vs none on placebo), hypertriglyceridaemia (n=24 vs none on placebo), rash (n=13 vs one on placebo), and neutropenia (n=10 vs none on placebo). Five (19%) participants on bexarotene and two (8%) on placebo discontinued the study drug due to adverse events. One episode of cholecystitis in a placebo-treated participant was the only serious adverse event. The change in mean lesional magnetisation transfer ratio was not different between the bexarotene group (0·25 percentage units [pu; SD 0·98]) and the placebo group (0·09 pu [0·84]; adjusted bexarotene-placebo difference 0·16 pu, 95% CI -0·39 to 0·71; p=0·55). INTERPRETATION: We do not recommend the use of bexarotene to treat patients with multiple sclerosis because of its poor tolerability and negative primary efficacy outcome. However, statistically significant effects were seen in some exploratory MRI and electrophysiological analyses, suggesting that other retinoid X receptor agonists might have small biological effects that could be investigated in further studies. FUNDING: Multiple Sclerosis Society of the United Kingdom.


Subject(s)
Bexarotene/pharmacology , Drug-Related Side Effects and Adverse Reactions , Multiple Sclerosis, Relapsing-Remitting/drug therapy , Outcome Assessment, Health Care , Remyelination/drug effects , Retinoid X Receptors/agonists , Adult , Bexarotene/administration & dosage , Bexarotene/adverse effects , Double-Blind Method , Evoked Potentials, Visual/physiology , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Multiple Sclerosis, Relapsing-Remitting/diagnostic imaging , Multiple Sclerosis, Relapsing-Remitting/physiopathology
7.
J Neurotrauma ; 38(21): 2978-2987, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34238034

ABSTRACT

This study aims to determine tissue-specific neurodegeneration across the spinal cord in patients with mild-moderate degenerative cervical myelopathy (DCM). Twenty-four mild-moderate DCM and 24 healthy subjects were recruited. In patients, a T2-weighted scan was acquired at the compression site, whereas in all participants a T2*-weighted and diffusion-weighted scan was acquired at the cervical level (C2-C3) and in the lumbar enlargement (i.e., rostral and caudal to the site of compression). We quantified intramedullary signal changes, maximal canal and cord compression, white (WM) and gray matter (GM) atrophy, and microstructural indices from diffusion-weighted scans. All patients underwent clinical (modified Japanese Orthopaedic Association; mJOA) and electrophysiological assessments. Regression analysis assessed associations between magnetic resonance imaging (MRI) readouts and electrophysiological and clinical outcomes. Twenty patients were classified with mild and 4 with moderate DCM using the mJOA scale. The most frequent site of compression was at the C5-C6 level, with maximum cord compression of 38.73% ± 11.57%. Ten patients showed imaging evidence of cervical myelopathy. In the cervical cord, WM and GM atrophy and WM microstructural changes were evident, whereas in the lumbar cord only WM showed atrophy and microstructural changes. Remote cervical cord WM microstructural changes were pronounced in patients with radiological myelopathy and associated with impaired electrophysiology. Lumbar cord WM atrophy was associated with lower limb sensory impairments. In conclusion, tissue-specific neurodegeneration revealed by quantitative MRI is already apparent across the spinal cord in mild-moderate DCM before the onset of severe clinical impairments. WM microstructural changes are particularly sensitive to remote pathologically and clinically eloquent changes in DCM.


Subject(s)
Cervical Cord/pathology , Gray Matter/pathology , Spinal Cord Diseases/complications , Spinal Cord Diseases/pathology , White Matter/pathology , Adult , Aged , Atrophy , Case-Control Studies , Cervical Vertebrae , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged
8.
Front Cell Neurosci ; 15: 616028, 2021.
Article in English | MEDLINE | ID: mdl-33981201

ABSTRACT

This study highlights the importance of looking beyond the main effect of movement to study alterations in functional response in the presence of central nervous system pathologies such as multiple sclerosis (MS). Data show that MS selectively affects regional BOLD (blood oxygenation level dependent) responses to variable grip forces (GF). It is known that the anterior and posterior BA 4 areas (BA 4a and BA 4p) are anatomically and functionally distinct. It has also been shown in healthy volunteers that there are linear (first order, typical of BA 4a) and nonlinear (second to fourth order, typical of BA 4p) BOLD responses to different levels of GF applied during a dynamic motor paradigm. After modeling the BOLD response with a polynomial expansion of the applied GFs, the particular case of BA 4a and BA 4p were investigated in healthy volunteers (HV) and MS subjects. The main effect of movement (zeroth order) analysis showed that the BOLD signal is greater in MS compared with healthy volunteers within both BA 4 subregions. At higher order, BOLD-GF responses were similar in BA 4a but showed a marked alteration in BA 4p of MS subjects, with those with greatest disability showing the greatest deviations from the healthy response profile. Therefore, the different behaviors in HV and MS could only be uncovered through a polynomial analysis looking beyond the main effect of movement into the two BA 4 subregions. Future studies will investigate the source of this pathophysiology, combining the present fMRI paradigm with blood perfusion and nonlinear neuronal response analysis.

9.
Brain ; 144(5): 1384-1395, 2021 06 22.
Article in English | MEDLINE | ID: mdl-33880511

ABSTRACT

Many studies report an overlap of MRI and clinical findings between patients with relapsing-remitting multiple sclerosis (RRMS) and secondary progressive multiple sclerosis (SPMS), which in part is reflective of inclusion of subjects with variable disease duration and short periods of follow-up. To overcome these limitations, we examined the differences between RRMS and SPMS and the relationship between MRI measures and clinical outcomes 30 years after first presentation with clinically isolated syndrome suggestive of multiple sclerosis. Sixty-three patients were studied 30 years after their initial presentation with a clinically isolated syndrome; only 14% received a disease modifying treatment at any time point. Twenty-seven patients developed RRMS, 15 SPMS and 21 experienced no further neurological events; these groups were comparable in terms of age and disease duration. Clinical assessment included the Expanded Disability Status Scale, 9-Hole Peg Test and Timed 25-Foot Walk and the Brief International Cognitive Assessment For Multiple Sclerosis. All subjects underwent a comprehensive MRI protocol at 3 T measuring brain white and grey matter (lesions, volumes and magnetization transfer ratio) and cervical cord involvement. Linear regression models were used to estimate age- and gender-adjusted group differences between clinical phenotypes after 30 years, and stepwise selection to determine associations between a large sets of MRI predictor variables and physical and cognitive outcome measures. At the 30-year follow-up, the greatest differences in MRI measures between SPMS and RRMS were the number of cortical lesions, which were higher in SPMS (the presence of cortical lesions had 100% sensitivity and 88% specificity), and grey matter volume, which was lower in SPMS. Across all subjects, cortical lesions, grey matter volume and cervical cord volume explained 60% of the variance of the Expanded Disability Status Scale; cortical lesions alone explained 43%. Grey matter volume, cortical lesions and gender explained 43% of the variance of Timed 25-Foot Walk. Reduced cortical magnetization transfer ratios emerged as the only significant explanatory variable for the symbol digit modality test and explained 52% of its variance. Cortical involvement, both in terms of lesions and atrophy, appears to be the main correlate of progressive disease and disability in a cohort of individuals with very long follow-up and homogeneous disease duration, indicating that this should be the target of therapeutic interventions.


Subject(s)
Brain/pathology , Disease Progression , Multiple Sclerosis, Chronic Progressive/pathology , Multiple Sclerosis, Relapsing-Remitting/pathology , Aged , Demyelinating Diseases/pathology , Disability Evaluation , Female , Humans , Longitudinal Studies , Magnetic Resonance Imaging , Male , Middle Aged
10.
Hum Brain Mapp ; 41(15): 4232-4247, 2020 10 15.
Article in English | MEDLINE | ID: mdl-32639104

ABSTRACT

Multicenter clinical and quantitative magnetic resonance imaging (qMRI) studies require a high degree of reproducibility across different sites and scanner manufacturers, as well as time points. We therefore implemented a multiparameter mapping (MPM) protocol based on vendor's product sequences and demonstrate its repeatability and reproducibility for whole-brain coverage. Within ~20 min, four MPM metrics (magnetization transfer saturation [MT], proton density [PD], longitudinal [R1], and effective transverse [R2*] relaxation rates) were measured using an optimized 1 mm isotropic resolution protocol on six 3 T MRI scanners from two different vendors. The same five healthy participants underwent two scanning sessions, on the same scanner, at each site. MPM metrics were calculated using the hMRI-toolbox. To account for different MT pulses used by each vendor, we linearly scaled the MT values to harmonize them across vendors. To determine longitudinal repeatability and inter-site comparability, the intra-site (i.e., scan-rescan experiment) coefficient of variation (CoV), inter-site CoV, and bias across sites were estimated. For MT, R1, and PD, the intra- and inter-site CoV was between 4 and 10% across sites and scan time points for intracranial gray and white matter. A higher intra-site CoV (16%) was observed in R2* maps. The inter-site bias was below 5% for all parameters. In conclusion, the MPM protocol yielded reliable quantitative maps at high resolution with a short acquisition time. The high reproducibility of MPM metrics across sites and scan time points combined with its tissue microstructure sensitivity facilitates longitudinal multicenter imaging studies targeting microstructural changes, for example, as a quantitative MRI biomarker for interventional clinical trials.


Subject(s)
Brain Mapping/standards , Image Processing, Computer-Assisted/standards , Magnetic Resonance Imaging/standards , Adult , Brain Mapping/instrumentation , Brain Mapping/methods , Female , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Male , Reproducibility of Results
11.
Mult Scler ; 26(9): 1093-1101, 2020 08.
Article in English | MEDLINE | ID: mdl-31169059

ABSTRACT

BACKGROUND: In multiple sclerosis (MS), disease effects on magnetisation transfer ratio (MTR) increase towards the ventricles. This periventricular gradient is evident shortly after first symptoms and is independent of white matter lesions. OBJECTIVE: To explore if alemtuzumab, a peripherally acting disease-modifying treatment, modifies the gradient's evolution, and whether baseline gradients predict on-treatment relapses. METHODS: Thirty-four people with relapsing-remitting MS underwent annual magnetic resonance imaging (MRI) scanning (19 receiving alemtuzumab (four scans each), 15 untreated (three scans each)). The normal-appearing white matter was segmented into concentric bands. Gradients were measured over the three bands nearest the ventricles. Mixed-effects models adjusted for age, gender, relapse rate, lesion number and brain parenchymal fraction compared the groups' baseline gradients and evolution. RESULTS: Untreated, the mean MTR gradient increased (+0.030 pu/band/year) but decreased following alemtuzumab (-0.045 pu/band/year, p = 0.037). Within the alemtuzumab group, there were no significant differences in baseline lesion number (p = 0.568) nor brain parenchymal fraction (p = 0.187) between those who relapsed within 4 years (n = 4) and those who did not (n = 15). However, the baseline gradient was significantly different (p = 0.020). CONCLUSION: Untreated, abnormal periventricular gradients worsen with time, but appear reversible with peripheral immunotherapy. Baseline gradients - but not lesion loads or brain volumes - may predict on-treatment relapses. Larger confirmatory studies are required.


Subject(s)
Alemtuzumab , Multiple Sclerosis, Relapsing-Remitting , White Matter , Alemtuzumab/therapeutic use , Brain/diagnostic imaging , Humans , Magnetic Resonance Imaging , Multiple Sclerosis, Relapsing-Remitting/diagnostic imaging , Multiple Sclerosis, Relapsing-Remitting/drug therapy , White Matter/diagnostic imaging
12.
Mult Scler ; 26(6): 679-687, 2020 05.
Article in English | MEDLINE | ID: mdl-30957691

ABSTRACT

BACKGROUND: In relapse-onset multiple sclerosis (MS), tissue abnormality - as assessed with magnetisation transfer ratio (MTR) imaging - is greater in the outer cortical and inner periventricular layers. The cause of this remains unknown but meningeal inflammation has been implicated, particularly lymphoid follicles, which are seen in secondary progressive (SP) but not primary progressive (PP) MS. Cortical and periventricular MTR gradients might, therefore, differ in PPMS and SPMS if these follicles are responsible. OBJECTIVE: We assessed cortical and periventricular MTR gradients in PPMS, and compared gradients between people with PPMS and SPMS. METHODS: Using an optimised processing pipeline, periventricular normal-appearing white matter and cortical grey-matter MTR gradients were compared between 51 healthy controls and 63 people with progressive MS (28 PPMS, 35 SPMS). RESULTS: The periventricular gradient was significantly shallower in healthy controls (0.122 percentage units (pu)/band) compared to PPMS (0.952 pu/band, p < 0.0001) and SPMS (1.360 pu/band, p < 0.0001). The cortical gradient was also significantly shallower in healthy controls (-2.860 pu/band) compared to PPMS (-3.214 pu/band, p = 0.038) and SPMS (-3.328 pu/band, p = 0.016). CONCLUSION: Abnormal periventricular and cortical MTR gradients occur in both PPMS and SPMS, suggesting comparable underlying pathological processes.


Subject(s)
Cerebral Cortex/pathology , Magnetic Resonance Imaging , Multiple Sclerosis, Chronic Progressive/pathology , White Matter/pathology , Adult , Cerebral Cortex/diagnostic imaging , Cohort Studies , Female , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Multiple Sclerosis, Chronic Progressive/diagnostic imaging , Multiple Sclerosis, Relapsing-Remitting/diagnostic imaging , Multiple Sclerosis, Relapsing-Remitting/pathology , White Matter/diagnostic imaging
13.
Magn Reson Med ; 82(3): 1025-1040, 2019 09.
Article in English | MEDLINE | ID: mdl-31081239

ABSTRACT

PURPOSE: To enable clinical applications of quantitative magnetization transfer (qMT) imaging by developing a fast method to map one of its fundamental model parameters, the bound pool fraction (BPF), in the human brain. THEORY AND METHODS: The theory of steady-state MT in the fast-exchange approximation is used to provide measurements of BPF, and bound pool transverse relaxation time ( T2B ). A sequence that allows sampling of the signal during steady-state MT saturation is used to perform BPF mapping with a 10-min-long fully echo planar imaging-based MRI protocol, including inversion recovery T1 mapping and B1 error mapping. The approach is applied in 6 healthy subjects and 1 multiple sclerosis patient, and validated against a single-slice full qMT reference acquisition. RESULTS: BPF measurements are in agreement with literature values using off-resonance MT, with average BPF of 0.114(0.100-0.128) in white matter and 0.068(0.054-0.085) in gray matter. Median voxel-wise percentage error compared with standard single slice qMT is 4.6%. Slope and intercept of linear regression between new and reference BPF are 0.83(0.81-0.85) and 0.013(0.11-0.16). Bland-Altman plot mean bias is 0.005. In the multiple sclerosis case, the BPF is sensitive to pathological changes in lesions. CONCLUSION: The method developed provides accurate BPF estimates and enables shorter scan time compared with currently available approaches, demonstrating the potential of bringing myelin sensitive measurement closer to the clinic.


Subject(s)
Echo-Planar Imaging/methods , Image Interpretation, Computer-Assisted/methods , Brain/diagnostic imaging , Humans , Multiple Sclerosis/diagnostic imaging , Myelin Sheath/chemistry
15.
Magn Reson Med ; 79(5): 2576-2588, 2018 05.
Article in English | MEDLINE | ID: mdl-28921614

ABSTRACT

PURPOSE: To develop a framework to fully characterize quantitative magnetization transfer indices in the human cervical cord in vivo within a clinically feasible time. METHODS: A dedicated spinal cord imaging protocol for quantitative magnetization transfer was developed using a reduced field-of-view approach with echo planar imaging (EPI) readout. Sequence parameters were optimized based in the Cramer-Rao-lower bound. Quantitative model parameters (i.e., bound pool fraction, free and bound pool transverse relaxation times [ T2F, T2B], and forward exchange rate [kFB ]) were estimated implementing a numerical model capable of dealing with the novelties of the sequence adopted. The framework was tested on five healthy subjects. RESULTS: Cramer-Rao-lower bound minimization produces optimal sampling schemes without requiring the establishment of a steady-state MT effect. The proposed framework allows quantitative voxel-wise estimation of model parameters at the resolution typically used for spinal cord imaging (i.e. 0.75 × 0.75 × 5 mm3 ), with a protocol duration of ∼35 min. Quantitative magnetization transfer parametric maps agree with literature values. Whole-cord mean values are: bound pool fraction = 0.11(±0.01), T2F = 46.5(±1.6) ms, T2B = 11.0(±0.2) µs, and kFB = 1.95(±0.06) Hz. Protocol optimization has a beneficial effect on reproducibility, especially for T2B and kFB . CONCLUSION: The framework developed enables robust characterization of spinal cord microstructure in vivo using qMT. Magn Reson Med 79:2576-2588, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Subject(s)
Cervical Cord/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Signal Processing, Computer-Assisted , Adult , Algorithms , Cervical Cord/chemistry , Female , Humans , Male , Myelin Sheath/chemistry
16.
Magn Reson Med ; 79(4): 2142-2148, 2018 04.
Article in English | MEDLINE | ID: mdl-28736946

ABSTRACT

PURPOSE: To develop a fast and robust method for measuring T1 in the whole cervical spinal cord in vivo, and to assess its reproducibility. METHODS: A spatially nonselective adiabatic inversion pulse is combined with zonally oblique-magnified multislice echo-planar imaging to produce a reduced field-of-view inversion-recovery echo-planar imaging protocol. Multi- inversion time data are obtained by cycling slice order throughout sequence repetitions. Measurement of T1 is performed using 12 inversion times for a total protocol duration of 7 min. Reproducibility of regional T1 estimates is assessed in a scan-rescan experiment on five heathy subjects. RESULTS: Regional mean (standard deviation) T1 was: 1108.5 (±77.2) ms for left lateral column, 1110.1 (±83.2) ms for right lateral column, 1150.4 (±102.6) ms for dorsal column, and 1136.4 (±90.8) ms for gray matter. Regional T1 estimates showed good correlation between sessions (Pearson correlation coefficient = 0.89 (P value < 0.01); mean difference = 2 ms, 95% confidence interval ± 20 ms); and high reproducibility (intersession coefficient of variation approximately 1% in all the regions considered, intraclass correlation coefficient = 0.88 (P value < 0.01, confidence interval 0.71-0.95)). CONCLUSIONS: T1 estimates in the cervical spinal cord are reproducible using inversion-recovery zonally oblique-magnified multislice echo-planar imaging. The short acquisition time and large coverage of this method paves the way for accurate T1 mapping for various spinal cord pathologies. Magn Reson Med 79:2142-2148, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Subject(s)
Cervical Cord/diagnostic imaging , Echo-Planar Imaging/methods , Adult , Algorithms , Brain/diagnostic imaging , Female , Healthy Volunteers , Humans , Image Interpretation, Computer-Assisted , Imaging, Three-Dimensional , Male , Motion , Phantoms, Imaging , Reproducibility of Results , Signal Processing, Computer-Assisted
17.
Hum Brain Mapp ; 38(5): 2566-2579, 2017 05.
Article in English | MEDLINE | ID: mdl-28240422

ABSTRACT

The relationship between the BOLD response and an applied force was quantified in the cerebellum using a power grip task. To investigate whether the cerebellum responds in an on/off way to motor demands or contributes to motor responses in a parametric fashion, similarly to the cortex, five grip force levels were investigated under visual feedback. Functional MRI data were acquired in 13 healthy volunteers and their responses were analyzed using a cerebellum-optimized pipeline. This allowed us to evaluate, within the cerebellum, voxelwise linear and non-linear associations between cerebellar activations and forces. We showed extensive non-linear activations (with a parametric design), covering the anterior and posterior lobes of the cerebellum with a BOLD-force relationship that is region-dependent. Linear responses were mainly located in the anterior lobe, similarly to the cortex, where linear responses are localized in M1. Complex responses were localized in the posterior lobe, reflecting its key role in attention and executive processing, required during visually guided movement. Given the highly organized responses in the cerebellar cortex, a key question is whether deep cerebellar nuclei show similar parametric effects. We found positive correlations with force in the ipsilateral dentate nucleus and negative correlations on the contralateral side, suggesting a somatotopic organization of the dentate nucleus in line with cerebellar and cortical areas. Our results confirm that there is cerebellar organization involving all grey matter structures that reflect functional segregation in the cortex, where cerebellar lobules and dentate nuclei contribute to complex motor tasks with different BOLD response profiles in relation to the forces. Hum Brain Mapp 38:2566-2579, 2017. © 2017 Wiley Periodicals, Inc.


Subject(s)
Brain Mapping , Cerebellar Nuclei/blood supply , Cerebellum/blood supply , Oxygen/blood , Adult , Cerebellar Nuclei/diagnostic imaging , Cerebellum/diagnostic imaging , Female , Functional Laterality , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Male , Task Performance and Analysis
18.
Brain ; 140(2): 387-398, 2017 02.
Article in English | MEDLINE | ID: mdl-28043954

ABSTRACT

In established multiple sclerosis, tissue abnormality-as assessed using magnetization transfer ratio-increases close to the lateral ventricles. We aimed to determine whether or not (i) these changes are present from the earliest clinical stages of multiple sclerosis; (ii) they occur independent of white matter lesions; and (iii) they are associated with subsequent conversion to clinically definite multiple sclerosis and disability. Seventy-one subjects had MRI scanning a median of 4.6 months after a clinically isolated optic neuritis (49 females, mean age 33.5 years) and were followed up clinically 2 and 5 years later. Thirty-seven healthy controls (25 females, mean age 34.4 years) were also scanned. In normal-appearing white matter, magnetization transfer ratio gradients were measured 1-5 mm and 6-10 mm from the lateral ventricles. In control subjects, magnetization transfer ratio was highest adjacent to the ventricles and decreased with distance from them; in optic neuritis, normal-appearing white matter magnetization transfer ratio was lowest adjacent to the ventricles, increased over the first 5 mm, and then paralleled control values. The magnetization transfer ratio gradient over 1-5 mm differed significantly between the optic neuritis and control groups [+0.059 percentage units/mm (pu/mm) versus -0.033 pu/mm, P = 0.010], and was significantly steeper in those developing clinically definite multiple sclerosis within 2 years compared to those who did not (0.132 pu/mm versus 0.016 pu/mm, P = 0.020). In multivariate binary logistic regression the magnetization transfer ratio gradient was independently associated with the development of clinically definite multiple sclerosis within 2 years (magnetization transfer ratio gradient odds ratio 61.708, P = 0.023; presence of T2 lesions odds ratio 8.500, P = 0.071). At 5 years, lesional measures overtook magnetization transfer ratio gradients as significant predictors of conversion to multiple sclerosis. The magnetization transfer ratio gradient was not significantly affected by the presence of brain lesions [T2 lesions (P = 0.918), periventricular T2 lesions (P = 0.580) or gadolinium-enhancing T1 lesions (P = 0.724)]. The magnetization transfer ratio gradient also correlated with Expanded Disability Status Scale score 5 years later (Spearman r = 0.313, P = 0.027). An abnormal periventricular magnetization transfer ratio gradient occurs early in multiple sclerosis, is clinically relevant, and may arise from one or more mechanisms that are at least partly independent of lesion formation.


Subject(s)
Cerebral Ventricles/diagnostic imaging , Magnetic Resonance Imaging , Multiple Sclerosis/diagnostic imaging , Adult , Atrophy , Cohort Studies , Disability Evaluation , Disease Progression , Female , Humans , Image Processing, Computer-Assisted , Logistic Models , Male , Middle Aged , Multiple Sclerosis/complications , Optic Neuritis/diagnostic imaging , Optic Neuritis/etiology , Protons , White Matter/pathology , Young Adult
19.
PLoS One ; 11(10): e0164890, 2016.
Article in English | MEDLINE | ID: mdl-27741303

ABSTRACT

Diffusion tensor imaging (DTI) has recently started to be adopted into clinical investigations of spinal cord (SC) diseases. However, DTI applications to the lower SC are limited due to a number of technical challenges, related mainly to the even smaller size of the SC structure at this level, its position relative to the receiver coil elements and the effects of motion during data acquisition. Developing methods to overcome these problems would offer new means to gain further insights into microstructural changes of neurological conditions involving the lower SC, and in turn could help explain symptoms such as bladder and sexual dysfunction. In this work, the feasibility of obtaining grey and white matter (GM/WM) DTI indices such as axial/radial/mean diffusivity (AD/RD/MD) and fractional anisotropy (FA) within the lumbosacral enlargement (LSE) was investigated using a reduced field-of-view (rFOV) single-shot echo-planar imaging (ss-EPI) acquisition in 14 healthy participants using a clinical 3T MR system. The scan-rescan reproducibility of the measurements was assessed by calculating the percentage coefficient of variation (%COV). Mean FA was higher in WM compared to GM (0.58 and 0.4 in WM and GM respectively), AD and MD were higher in WM compared to GM (1.66 µm2ms-1 and 0.94 µm2ms-1 in WM and 1.2 µm2ms-1 and 0.82 µm2ms-1 in GM for AD and MD respectively) and RD was lower in WM compared to GM (0.58 µm2ms-1 and 0.63 µm2ms-1 respectively). The scan-rescan %COV was lower than 10% in all cases with the highest values observed for FA and the lowest for MD. This pilot study demonstrates that it is possible to obtain reliable tissue-specific estimation of DTI indices within the LSE using a rFOV ss-EPI acquisition. The DTI acquisition and analysis protocol presented here is clinically feasible and may be used in future investigations of neurological conditions implicating the lower SC.


Subject(s)
Magnetic Resonance Imaging , Spinal Cord/diagnostic imaging , Adult , Female , Gray Matter/diagnostic imaging , Healthy Volunteers , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Pilot Projects , Reproducibility of Results , Signal-To-Noise Ratio , White Matter/diagnostic imaging , Young Adult
20.
J Neurol Neurosurg Psychiatry ; 87(11): 1212-1217, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27601434

ABSTRACT

OBJECTIVE: To assess the association between proximity to the inner (ventricular and aqueductal) and outer (pial) surfaces of the brain and the distribution of normal appearing white matter (NAWM) and grey matter (GM) abnormalities, and white matter (WM) lesions, in multiple sclerosis (MS). METHODS: 67 people with relapse-onset MS and 30 healthy controls were included in the study. Volumetric T1 images and high-resolution (1 mm3) magnetisation transfer ratio (MTR) images were acquired and segmented into 12 bands between the inner and outer surfaces of the brain. The first and last bands were discarded to limit partial volume effects with cerebrospinal fluid. MTR values were computed for all bands in supratentorial NAWM, cerebellar NAWM and brainstem NA tissue, and deep and cortical GM. Band WM lesion volumes were also measured. RESULTS: Proximity to the ventricular surfaces was associated with progressively lower MTR values in the MS group but not in controls in supratentorial and cerebellar NAWM, brainstem NA and in deep and cortical GM. The density of WM lesions was associated with proximity to the ventricles only in the supratentorial compartment, and no link was found with distance from the pial surfaces. CONCLUSIONS: In MS, MTR abnormalities in NAWM and GM are related to distance from the inner and outer surfaces of the brain, and this suggests that there is a common factor underlying their spatial distribution. A similar pattern was not found for WM lesions, raising the possibility that different factors promote their formation.


Subject(s)
Brain/diagnostic imaging , Brain/pathology , Cone-Beam Computed Tomography/methods , Gray Matter/diagnostic imaging , Gray Matter/pathology , Magnetic Resonance Imaging/methods , Multiple Sclerosis, Relapsing-Remitting/diagnostic imaging , Multiple Sclerosis, Relapsing-Remitting/pathology , White Matter/diagnostic imaging , White Matter/pathology , Adult , Brain Mapping , Brain Stem/diagnostic imaging , Brain Stem/pathology , Cerebellum/diagnostic imaging , Cerebellum/pathology , Cerebral Aqueduct/diagnostic imaging , Cerebral Cortex/diagnostic imaging , Cerebral Cortex/pathology , Cerebral Ventricles/diagnostic imaging , Female , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Pia Mater/diagnostic imaging , Pia Mater/pathology , Reference Values