Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Artif Organs ; 47(7): 1065-1070, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37366022

ABSTRACT

The quest to replace the natural heart with an artificial one as a permanent system is among the remaining holy grails in medicine and surgery. Beginning in 1969, when the first total artificial heart (TAH) was implanted into a human, to the present, several types have been developed-the AbioCor was among them. On November 5th, 2001, our team at Hahnemann University Hospital in Philadelphia, Pennsylvania placed the world's fifth AbioCor. Excerpts of that moment in time were recorded and serve as a memorial to the past and a testimony to the present and future quest of this elusive holy grail.


Subject(s)
Heart, Artificial , Humans , Pennsylvania
2.
Ann Cardiothorac Surg ; 10(3): 301-310, 2021 May.
Article in English | MEDLINE | ID: mdl-34159112

ABSTRACT

BACKGROUND: With increased use of continuous-flow left ventricular assist devices (CF-LVAD), development of malignant tumors in this population is not uncommon. We sought to evaluate malignancies in CF-LVAD patients and evaluate the outcomes of treatment strategies. METHODS: Overall, 18 articles consisting of 28 patients were identified who developed malignancies after CF-LVAD placement. Patient-level data were extracted for systematic review. RESULTS: Median patient age was 60 years [59-67] and 85.7% (24/28) were male. CF-LVAD was placed as bridge-to-transplant (BTT) in 60.9% (14/23) of patients. The three most common malignancy types were GI in 35.7% (10/28) of patients, lung in 21.4% (6/28) and skin in 10.7% (3/28). Median time from CF-LVAD implant to malignancy diagnosis was 6.9 [2.5-12.8] months. Metastatic disease occurred in 17.9% (5/28) over a median time of 5.0 [1.0-82.0] months from the diagnosis. Surgical resection of the malignancy was performed in 57.1% (16/28) of patients. Our results showed that while there was a significantly higher probability of survival among patients who underwent surgery versus those who did not, when only stage I and II patients were included in the analysis, this difference was no longer statistically significant. Three patients were relisted for heart transplant after surgical treatment, and two received the transplant. CONCLUSIONS: Surgical management of malignancies in patients on CF-LVADs may improve survival and transplant eligibility status, therefore, a CF-LVAD should not always preclude surgical treatment.

3.
Surgery ; 170(2): 390-396, 2021 08.
Article in English | MEDLINE | ID: mdl-33812754

ABSTRACT

BACKGROUND: Carcinoid heart disease (CaHD) develops from vasoactive substances released by neuroendocrine tumors, which can cause significant patient morbidity and mortality without surgical intervention. We performed a systematic review and meta-analysis to elucidate granular perioperative details and long-term outcomes in these patients. METHODS: Electronic search of Ovid, Scopus, Cumulative Index of Nursing and Allied Health Literature, and Cochrane Controlled Trials Register was performed to examine surgical treatment of carcinoid disease. Nine articles comprising 416 patients were selected. Study-level data were extracted and pooled for meta-analysis. RESULTS: Mean patient age was 63 years (95% confidence interval, 57-70) with 53% (95% confidence interval, 46-61) of patients being male. In addition, 75% (95% confidence interval, 54-96) of neuroendocrine tumors originated from the small bowel or colon and 98% (95% confidence interval, 93-100) had liver metastases. Right heart failure was present in 48% (95% confidence interval, 14-81). Moderate or severe regurgitation was present in 97% (95% confidence interval, 95-99) of tricuspid and 72% (95% confidence interval, 58-83) of pulmonary valves. In addition, 99% (95% confidence interval, 98-100) of tricuspid and 59% (95% confidence interval, 38-79) of pulmonary valves were replaced. Bioprosthetic valves were used in 80% (95% confidence interval, 68-93) of tricuspid positions. Mean hospital duration of stay was 16 days (95% confidence interval, 7-25). Thirty-day mortality was 9% (95% confidence interval, 6-12). Mean follow-up was 25 months (95% confidence interval, 11-39). Median survival was 3 years (95% confidence interval, 2.5-3.5). CONCLUSION: For patients >18 years of age, surgical treatment of carcinoid heart disease can be performed with a reasonable safety profile. However, overall survival appears to have ongoing effects of the primary disease.


Subject(s)
Carcinoid Heart Disease/surgery , Carcinoid Heart Disease/diagnosis , Carcinoid Heart Disease/mortality , Humans
4.
Artif Organs ; 45(8): 819-826, 2021 Aug.
Article in English | MEDLINE | ID: mdl-33377216

ABSTRACT

With mounting time on continuous-flow left ventricular assist device (CF-LVAD) support, patients occasionally sustain damage to the device driveline. Outcomes associated with external and internal driveline damage and repair are currently not well documented. We sought to evaluate the outcomes of driveline damage and its repair. Electronic search was performed to identify all relevant studies published over the past 20 years. Fifteen studies were selected for analysis comprising of 55 patients with CF-LVAD dysfunction due to driveline damage. Demographic and perioperative variables along with outcomes including survival rates were extracted and pooled for the systematic review. Most patients (53/55) were supported on HeartMate II LVAD (Abbott Laboratories, Abbott Park, IL). Internal damage was more commonly reported than external damage [69.1% (38/55) vs. 30.9% (17/55), P = .01]. Median time to driveline damage was 1.9 years [IQR 1.0, 2.5]. Most patients presented with a CF-LVAD alarm [94.5% (52/55)] and patients with internal driveline damage had a significantly higher rate of alarm activation compared to that observed for those with external damage [38/38 (100%) vs. 14/17 (82.4%), P = .04]. Patients with internal driveline dysfunction were more likely to experience component wear compared to those with external driveline dysfunction [10/38 (26.3%) vs. 0/17 (0%), P = .05]; 14.5% of patients (8/55) underwent external repair of the driveline, 5.5% (3/55) were treated with rescue tape, and 5.5% (3/55) were placed on an ungrounded cable, indicating a short-to-shield event had occurred. A total of 49.1% of patients (27/55) underwent CF-LVAD exchange, 5.5% (3/55) were weaned off the CF-LVAD to explant, and 5.5% (3/55) underwent emergent heart transplantation. The median length of hospital stay was 12 days [IQR 7, 12] and 30-day mortality rate was 14.5% (8/55). Driveline damage was more commonly reported at an internal location and despite being a well-recognized complication, mortality still appears high.


Subject(s)
Equipment Failure Analysis , Heart-Assist Devices/adverse effects , Humans , Survival Rate
5.
Artif Organs ; 44(11): 1150-1161, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32416628

ABSTRACT

Gastrointestinal bleeding (GIB) is a common adverse event after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate patterns of GIB development and related outcomes in CF-LVAD recipients. An electronic search was performed to identify all articles related to GIB in the setting of CF-LVAD implantation. A total of 34 studies involving 1087 patients were pooled for analysis. Mean patient age was 60 years (95% CI 57-64) and 24% (95% CI 21-28%) were female. The mean time from CF-LVAD implantation to the first GIB was 54 days (95% CI 24-84) with 40% (95% CI 34-45%) of patients having multiple episodes of GIB. Anemia was present in 75% (95% CI 41-93%) and the most common etiology of bleeding was arteriovenous malformations (36% [95% CI 24-50%]). The mean duration of follow-up was 14.6 months (95% CI 6.9-22.3) during which the all-cause mortality rate was 21% (95% CI 12-36%) and the mortality rate from GIB was 4% (95% CI 2-9%). Thromboembolic events occurred in 32% (95% CI 22-44%) of patients with an ischemic stroke rate of 16% (95% CI 3-51%) and a pump thrombosis rate of 8% (95%CI 3-22%). Heart transplantation was performed in 31% (95% CI 18-47%) of patients, after which 0% (95% CI 0-10%) experienced recurrent GIB. GIB is a major source of morbidity among CF-LVAD recipients. While death due to GIB is rare, cessation of anticoagulation during treatment increases the risk of subsequent thrombotic events. Heart transplant in these patients appears to reliably resolve the risk of future GIB.


Subject(s)
Gastrointestinal Hemorrhage/etiology , Heart-Assist Devices/adverse effects , Humans , Intensive Care Units , Length of Stay , Survival Analysis
6.
Expert Rev Med Devices ; 17(5): 399-404, 2020 May.
Article in English | MEDLINE | ID: mdl-32270720

ABSTRACT

Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electronic search was performed to identify the presence of an MMV at the time of CF-LVAD implantation. Of the 1,168 studies identified, only five studies consisting of seven CF-LVAD patients met the inclusion criteria. Patient-level data were extracted and analyzed.Expert opinion: The median patient age was 54 (IQR: 42-61) years and 71.4% (5/7) were male. Non-ischemic cardiomyopathy was the predominant etiology (83.3%, 5/6) of heart failure, and bridge-to-transplant the predominant indication (85.7%, 6/7) for CF-LVAD. Aortic valve prosthesis was present in 42.9% (3/7) of patients. Median time from MMV to CF-LVAD placement was 6.0 years (IQR: 1.3-15.0). The median lower limit of the INR range was 2.8 (IQR: 2.1-3.0) and upper limit of the INR range was 3.5 (IQR: 3.1-3.5). During a median follow-up time of 120 (IQR: 70-201) days, there were no major GI bleeds or clinically significant thromboembolic complications. With adequate anticoagulation, preexisting MMVs in CF-LVAD patients did not result in clinically significant thromboembolic events.


Subject(s)
Heart Valve Prosthesis , Heart-Assist Devices , Mitral Valve/surgery , Prosthesis Implantation , Adult , Female , Heart-Assist Devices/adverse effects , Humans , Male , Middle Aged , Postoperative Complications/etiology , Risk Factors , Survival Analysis
7.
Transplant Rev (Orlando) ; 34(2): 100517, 2020 04.
Article in English | MEDLINE | ID: mdl-31831325

ABSTRACT

BACKGROUND: Combined heart-liver transplantation (CHLT) has become a viable option for treating concomitant heart and liver failure. However, data are lacking with respect to long-term outcomes. METHODS: An electronic search was performed to identify all studies on CHLT. Following application of inclusion and exclusion criteria, a total of seven studies consisting of 99 CHLT patients were included from the original 1864 articles. RESULTS: CHLT recipient mean age was 53.0 years (95% CI 48.0-58.0), 67.5% of which (95% CI 56.5-76.9) were male. 65.5% (95% CI 39.0-85.0) of patients developed heart failure due to amyloidosis whereas 21.6% (95% CI 12.3-35.2) developed heart failure due to congenital causes. The most common indication for liver transplant was amyloidosis [65.5% (95% CI 39.0-85.0)] followed by liver failure due to hepatitis C [13.8% (95% CI 2.1-54.4)]. The mean intensive care unit length of stay was 8 days (95% CI 5-11) with a mean length of stay of 24 days (95% CI 17-31). Cardiac allograft rejection within the first year was 24.7% (95% CI 9.5-50.7), including antibody mediated [5% (95% CI 1.7-15.2)] and T-cell mediated rejection [22.7% (95% CI 8.8-47.1)]. Overall survival was 87.5% (95% CI 78.6-93.0) at 1 year and 84.3% (95% CI 75.4-90.5) at 5 years. CONCLUSIONS: CHLT in select patients with coexisting end-stage heart and liver failure appears to offer high survival and low rejection rates.


Subject(s)
Graft Rejection/immunology , Heart Failure/therapy , Heart Transplantation , Liver Failure/therapy , Liver Transplantation , Graft Survival , Heart Failure/complications , Heart Failure/mortality , Humans , Liver Failure/complications , Liver Failure/mortality , Survival Analysis , Time Factors , Treatment Outcome
8.
Heart Fail Rev ; 25(6): 985-992, 2020 11.
Article in English | MEDLINE | ID: mdl-31820204

ABSTRACT

Stenosis in the continuous-flow left ventricular assist device (CF-LVAD) outflow graft is caused by various factors. We discuss indications for percutaneous intervention of outflow graft complications and evaluate the use of this treatment in re-establishing adequate CF-LVAD flow. An electronic search was performed to identify all studies in the English literature reporting CF-LVAD outflow graft stenting. Twenty-one studies consisting of 26 patients were included. Patient-level data were extracted for statistical analysis. Median patient age was 59 years [45.8-67.0] and 65.4% (17/26) were male. 58.3% (14/24) of patients had HeartWare HVAD, 37.5% (9/24) had HeartMate II LVAD, and 4.2% (1/24) had HeartMate III LVAS. Median time from device placement to outflow graft stenting was 24.0 months [7.8-30.4]. 76.9% of patients (20/26) presented with heart failure. Complications of the CF-LVAD outflow graft included thrombosis in nine patients (34.6%), stenosis in nine patients (34.6%), kinking in three patients (11.5%), pseudoaneurysm in one patient (3.8%), external graft compression in one patient (3.8%), and bronchial-arterial fistula in one patient (3.6%). Immediate flow improvement occurred in 23/26 patients (88.5%), with the remaining 11.5% (3/26) requiring additional procedures. Pre- and post-intervention flows were 2.9 L/min [2.0-3.5] and 4.7 L/min [4.1-4.8] respectively (p = 0.01). Of patients, 96.2% (25/26) were discharged with a median time to discharge of 4 days [3.0-5.0]. The 30-day mortality was 6.7% (1/15). Overall mortality during the median follow-up of 90 days was 9.5% (2/21). Outflow graft stenting appears to effectively alleviate CF-LVAD outflow graft obstruction and is associated with low overall mortality.


Subject(s)
Heart Failure/surgery , Heart Ventricles/physiopathology , Heart-Assist Devices/adverse effects , Postoperative Complications/mortality , Stents/adverse effects , Constriction, Pathologic/mortality , Global Health , Heart Failure/physiopathology , Humans , Prosthesis Failure , Survival Rate/trends
9.
Ann Cardiothorac Surg ; 8(1): 19-31, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30854309

ABSTRACT

BACKGROUND: Heparin-induced thrombocytopenia (HIT) is a severe antibody-mediated reaction leading to transient prothrombosis. However, its incidence in patients on extracorporeal life support (ECLS) is not well described. The aim of this systematic review was to report the incidence of HIT in patients on ECLS, as well as compare the characteristics and outcomes of HIT in patients undergoing veno-arterial extracorporeal membrane oxygenation (VA-ECMO) and veno-venous ECMO (VV-ECMO). METHODS: An electronic search was performed to identify all studies in the English literature examining outcomes of patients with HIT on ECLS. All identified articles were systematically assessed using specific inclusion and exclusion criteria. Random effects meta-analysis as well as univariate analysis was performed. RESULTS: Of 309 patients from six retrospective studies undergoing ECLS, 83% were suspected, and 17% were confirmed to have HIT. Due to the sparsity of relevant retrospective data regarding patients with confirmed HIT on ECLS, patient-based data was subsequently collected on 28 patients from case reports and case series. Out of these 28 patients, 53.6% and 46.4% of them underwent VA-ECMO and VV-ECMO, respectively. Patients on VA-ECMO had a lower median platelet count nadir (VA-ECMO: 26.0 vs. VV-ECMO: 45.0 per µL, P=0.012) and were more likely to experience arterial thromboembolism (VA-ECMO: 53.3% vs. VV-ECMO: 0.0%, P=0.007), though there was a trend towards decreased likelihood of experiencing ECLS circuit oxygenator thromboembolism (VA-ECMO: 0.0% vs. VV-ECMO: 30.8%, P=0.075) and thromboembolism necessitating ECLS device or circuit exchange (VA-ECMO: 13.3% vs. VV-ECMO 53.8%, P=0.060). Kaplan-Meier survival plots including time from ECLS initiation reveal no significant differences in survival in patients supported on VA-ECMO as compared to VV-ECMO (P=0.300). CONCLUSIONS: Patients who develop HIT on VA-ECMO are more likely to experience more severe thrombocytopenia and arterial thromboembolism than those on VV-ECMO. Further research in this area and development of standardized protocols for the monitoring, diagnosis and management of HIT in patients on ECLS support are warranted.

10.
Artif Organs ; 43(7): E124-E138, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30810232

ABSTRACT

Infection remains the Achilles heel of left ventricular assist device (LVAD) therapy. However, an optimal antimicrobial surgical infection prophylaxis (SIP) regimen has not been established. This study evaluated the efficacy of a single-drug SIP compared to a multi-drug SIP on clinical outcomes in patients undergoing continuous-flow LVAD (CF-LVAD) and pulsatile LVAD (P-LVAD) implantation. An electronic search was performed to identify studies in the English literature on SIP regimens in patients undergoing LVAD implantation. Identified articles were assessed for inclusion and exclusion criteria. Fourteen articles with 1,311 (CF-LVAD: 888; P-LVAD: 423) patients were analyzed. Overall, 501 (38.0%) patients received single-drug SIP, whereas 810 (62.0%) received multi-drug SIP. Time to infection was comparable between groups. There was no significant difference in overall incidence of LVAD-specific infections [single-drug: 18.7% vs. multi-drug: 24.8%, P = 0.49] including driveline infections [single-drug: 14.1% vs. multi-drug: 20.8%, P = 0.37]. Compared to single-drug SIP, patients who received multi-drug SIP had a significantly lower survival rate [single-drug: 90.0% vs. multi-drug: 76.0%, P = 0.01] and infection-free survival rate [single-drug: 88.4% vs. multi-drug: 77.3%, P = 0.04] at 90 days. However, there were no significant differences in 1-year survival and 1-year infection-free survival between groups. No survival differences were observed in the CF-LVAD subset as well. This study demonstrated no additional advantage of a multi-drug compared to a single-drug regimen for SIP. Although there was a modest advantage in early survival among CF-LVAD and P-LVAD patients who received single-drug SIP, there were no significant differences in the 1-year survival and 1-year infection-free survival.


Subject(s)
Anti-Infective Agents/therapeutic use , Heart-Assist Devices/adverse effects , Prosthesis-Related Infections/prevention & control , Heart Ventricles/surgery , Humans , Prosthesis-Related Infections/epidemiology , Survival Analysis , Treatment Outcome
11.
Artif Organs ; 43(5): 448-457, 2019 May.
Article in English | MEDLINE | ID: mdl-30357880

ABSTRACT

No standardized treatment algorithm exists for the management of continuous-flow left ventricular assist device (CF-LVAD)-specific infections. The aim of this systematic review and meta-analysis was to compare the outcomes of CF-LVAD-specific infections as managed by device exchange to other treatment modalities not involving device exchange. Electronic search was performed to identify all studies in the English literature relating to the management of CF-LVAD-specific infections. All identified articles were systematically assessed for selection criteria. Thirteen studies with 158 cases of CF-LVAD-specific infection were pooled for analysis. Overall, 18/158 (11.4%) patients underwent CF-LVAD exchange, and 140/158 (88.6%) patients were treated with non-exchange modalities. The proportion of patients with isolated driveline infections or pump or pocket infections did not differ significantly between the groups. During a mean follow-up of 290 days, there were no significant differences in the overall mortality [exchange 17.6% (4.3-50.6) vs. non-exchange 23.3% (15.8-32.9), P = 0.67] and infection recurrence rates [exchange 26.7% (8.7-58.0) vs. non-exchange 38.6% (15.4-68.5), P = 0.56]. In the setting of CF-LVAD-specific infections, device exchange does not appear to confer an advantage in the overall mortality and infection recurrence as compared to non-exchange modalities.


Subject(s)
Device Removal , Heart-Assist Devices/adverse effects , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/therapy , Heart Ventricles/physiopathology , Humans , Prosthesis-Related Infections/physiopathology , Recurrence , Survival Analysis
12.
World J Clin Cases ; 2(8): 373-6, 2014 Aug 16.
Article in English | MEDLINE | ID: mdl-25133150

ABSTRACT

A 50-year-old male who underwent a HeartMate II left ventricular assist device placement for ischemic cardiomyopathy presented with discolored urine and hemolysis 3 mo after the operation. His hemolysis was thought to be due to thrombosis within the pump. Imaging studies were not able to visualize a left ventricular thrombus. Medical management with anticoagulation failed and he underwent surgery for a pump exchange. Intraoperatively, a firm thrombus was found within the pump of the HeartMate II, and the color of the urine changed dramatically from cola-colored to yellow which enabled us to confirm the diagnosis.

13.
J Thorac Cardiovasc Surg ; 145(2): 548-54, 2013 Feb.
Article in English | MEDLINE | ID: mdl-22405676

ABSTRACT

OBJECTIVES: Cardiogenic shock after cardiac surgery is accompanied by a high mortality rate. Early institution of hemodynamic support with a versatile, easy to insert left ventricular assist device might help bridge patients to recovery or to the next therapy, and improve the outcomes. METHODS: Patients developing cardiogenic shock or low cardiac output syndrome after being weaned off cardiopulmonary bypass were enrolled in a prospective single-arm feasibility study (RECOVER I). The primary safety endpoint was the frequency of major adverse events (death, stroke) at 30 days or discharge, whichever was longer. The primary efficacy endpoint was survival of the patient to implementation of the next therapy, which included recovery at 30 days after device removal and bridge-to-other-therapy. RESULTS: Sixteen patients provided informed consent and were enrolled in the study. Hemodynamics improved immediately after the initiation of mechanical support: cardiac index, 1.65 versus 2.7 L/min/m(2) (P = .0001); mean arterial pressure, 71.4 versus 83.1 mm Hg (P = .01); and pulmonary artery diastolic pressure, 28.0 versus 19.8 mm Hg (P < .0001). The pump provided an average of 4.0 ± 0.6 L/min of flow for an average duration of 3.7 ± 2.9 days (range, 1.7-12.6). The primary safety endpoint occurred in 2 patients (13%; 1 stroke and 1 death). For the primary efficacy endpoint, recovery of the native heart function was obtained in 93% of the patients discharged, with bridge-to-other-therapy in 7%. Survival to 30 days, 3 months, and 1 year was 94%, 81%, and 75%, respectively. CONCLUSIONS: The use of the Impella 5.0/left direct device is safe and feasible in patients presenting with postcardiotomy cardiogenic shock. The device was rapidly inserted, enabled early support, and yielded favorable outcomes.


Subject(s)
Cardiac Output, Low/therapy , Cardiac Surgical Procedures/adverse effects , Cardiopulmonary Bypass/adverse effects , Heart-Assist Devices , Shock, Cardiogenic/therapy , Adult , Aged , Cardiac Output, Low/etiology , Cardiac Output, Low/mortality , Cardiac Output, Low/physiopathology , Cardiac Surgical Procedures/mortality , Cardiopulmonary Bypass/mortality , Feasibility Studies , Female , Hemodynamics , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Recovery of Function , Shock, Cardiogenic/etiology , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Stroke/etiology , Time Factors , Treatment Outcome , United States
14.
J Cardiothorac Surg ; 7: 21, 2012 Mar 12.
Article in English | MEDLINE | ID: mdl-22409904

ABSTRACT

Left Ventricular Assist Device (LVAD) for Destination Therapy (DT) is an established therapy for end stage heart failure patients who are not transplant candidates. Many DT patients requiring LVADs have had prior open heart surgery, the majority of whom had prior sternotomy. In addition, DT patients tend to be older and more likely to have more significant co-morbidities than their Bridge-To-Transplant (BTT) counterparts. As such, placement of an implantable LVAD in DT patients can be technically hazardous and potentially prone to more perioperative complications. The purpose of this report is to describe an alternative implantation approach for the implantation of the Heartmate II™ LVAD in high risk DT patients.


Subject(s)
Heart Failure/surgery , Heart-Assist Devices , Prosthesis Implantation/methods , Aged , Humans , Intraoperative Complications/prevention & control , Male , Prosthesis Implantation/instrumentation , Retrospective Studies , Risk
15.
J Card Surg ; 27(2): 264-5, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22372872

ABSTRACT

Left ventricular assist device (LVAD) for destination therapy (DT) is an established therapy. More patients requiring LVADs have had prior open heart surgery, the majority of whom had prior sternotomy. As such, placement of an implantable LVAD in a redo setting can be hazardous. This report describes the implant of a Heartmate II™ LVAD in a patient with a prior ACORN CorCap™.


Subject(s)
Heart Failure/surgery , Heart-Assist Devices , Prosthesis Implantation/methods , Aged , Cardiopulmonary Bypass , Humans , Male , Reoperation , Sternotomy , Thoracotomy
17.
J Clin Anesth ; 23(6): 451-5, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21911190

ABSTRACT

STUDY OBJECTIVE: To investigate associations of heart rate variability (HRV) measurements with postoperative atrial fibrillation (AF) in patients undergoing off-pump coronary surgery. DESIGN: Prospective, observational, exploratory study. SETTING: Large university-affiliated community medical center. PATIENTS: 50 patients undergoing off-pump coronary artery bypass grafting (CABG). INTERVENTIONS: Preoperative recording of electrocardiograms (ECGs) with subsequent off-line HRV analysis. Monitored ECG telemetry for 5 days after operation. MEASUREMENTS: Frequency and time domain analyses, and additional non-linear HRV determinations. Multivariate regression analysis of predictors of postoperative AF. MAIN RESULTS: AF occurred in 23 (46%) patients. Only the low to high-frequency ratio was associated with AF (2.35 ± 1.8 v. 4.57 ± 5.0 for patients without AF, P < 0.05). CONCLUSIONS: The off-pump approach does not protect against AF, and nonlinear HRV analyses provide little value in predicting AF after off-pump CABG.


Subject(s)
Atrial Fibrillation/diagnosis , Coronary Artery Bypass, Off-Pump/adverse effects , Heart Rate/physiology , Postoperative Complications/diagnosis , Aged , Electrocardiography , Female , Humans , Male , Middle Aged , Nonlinear Dynamics , Predictive Value of Tests , Prospective Studies , Regression Analysis
18.
J Cardiothorac Surg ; 5: 126, 2010 Dec 08.
Article in English | MEDLINE | ID: mdl-21143858

ABSTRACT

A healthy 53 year old man developed profound cardiogenic shock following instillation of bupivacaine-lidocaine-epinephrine solution as a locoregional anesthetic for elective outpatient shoulder surgery. Intubation, resuscitation, and transfer to the nearby hospital were done: echocardiography showed profound biventricular dysfunction; cardiac catheterization showed normal coronary arteries. Despite placement of an intra-aortic balloon pump and intravenous vasoactive drugs, the patient remained in shock. Stabilization was achieved with emergent institution of cardiopulmonary bypass and placement of a temporary left ventricular assist device (LVAD). Twenty-four hours later, cardiac function normalized and the LVAD was removed. The patient was discharged five days later and remained with normal heart function in three-year follow-up.


Subject(s)
Anesthesia, Conduction/adverse effects , Anesthetics, Local/adverse effects , Heart-Assist Devices , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Arthroscopy , Bupivacaine/adverse effects , Epinephrine/adverse effects , Humans , Lidocaine/adverse effects , Male , Middle Aged , Shock, Cardiogenic/diagnosis , Vasoconstrictor Agents/adverse effects
19.
J Cardiothorac Vasc Anesth ; 24(5): 780-4, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20650657

ABSTRACT

OBJECTIVE: To determine if lengths of stay in intensive care and the hospital are associated with extubation in the operating room at the conclusion of cardiac surgery. DESIGN: A nonrandomized, observational study with propensity score-guided case-control matching of prospectively collected data. SETTING: Three interrelated, university-affiliated, community hospitals. PARTICIPANTS: Three thousand three hundred seventeen patients undergoing elective or urgent coronary artery, valve repair or replacement, or combined surgery between 2000 and 2006. INTERVENTIONS: Tracheal extubation occurred, based on history and intraoperative events, either immediately in the operating room or in the intensive care unit. MEASUREMENTS AND MAIN RESULTS: Of 3,317 patients in the institutions' Society of Thoracic Surgeons database, 3,089 were extubated within 24 hours, 69% of them in the operating room. Only 0.6% of patients extubated in the operating room required reintubation, compared with 5.9% extubated in the intensive care unit (p < 0.0001). By logistic regression, 12 of 25 preoperative and intraoperative factors generated a propensity score for each of the 2,595 patients with complete data, representing the likelihood of immediate extubation (c-statistic = 0.727). A "greedy 5 to 1" propensity score-matching technique created 713 matched pairs of patients by extubation pathway. Those undergoing immediate extubation had reductions in intensive care duration by 23 hours on average (median from 46 to 27 hours, p < 0.0001) and in hospital length of stay by 0.8 days on average (median = 6 for each, p < 0.0001). Cox regression, using matched pairs as strata, identified the following independent predictors of length of stay in the intensive care unit and hospital: immediate extubation in the operating room, need for reintubation, postoperative renal failure, and postoperative atrial fibrillation. CONCLUSIONS: Selection of patients for immediate extubation in the operating room by experienced clinicians was associated with shorter ICU and hospital stays. Immediate extubation rarely resulted in tracheal re-intubation.


Subject(s)
Cardiac Surgical Procedures , Critical Care/methods , Device Removal/methods , Length of Stay , Operating Rooms/methods , Postoperative Care/methods , Aged , Aged, 80 and over , Cardiac Surgical Procedures/methods , Case-Control Studies , Cohort Studies , Critical Care/trends , Device Removal/trends , Female , Humans , Intubation, Intratracheal/methods , Length of Stay/trends , Male , Middle Aged , Operating Rooms/trends , Postoperative Care/trends , Prospective Studies , Time Factors
20.
ASAIO J ; 54(3): 332-4, 2008.
Article in English | MEDLINE | ID: mdl-18496285

ABSTRACT

The need for a right ventricular assist device following an implantable left ventricular assist device creates a complex situation for the surgeon, nursing staff, and the patient. The purpose of this report is to describe the rationale, technical, and perioperative issues of a hybrid ventricular assist device consisting of a Heartmate XVE (Thoratec, Inc., Pleasonton, CA) left ventricular assist device and Abiomed AB5000 right ventricular assist device (Abiomed, Inc., Danvers, MA).


Subject(s)
Heart-Assist Devices , Ventricular Dysfunction, Left/surgery , Ventricular Dysfunction, Right/surgery , Adult , Cardiomyopathies/etiology , Cardiomyopathies/physiopathology , Cardiomyopathies/surgery , Cardiopulmonary Bypass , Equipment Design , Female , Heart Transplantation , Hemodynamics , Hemorheology , Humans , Postpartum Period , Pregnancy , Puerperal Disorders/physiopathology , Puerperal Disorders/therapy , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Right/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...