Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
J Magn Reson ; 364: 107712, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38879927

ABSTRACT

Radio-Frequency (RF) pulse calibration is an essential step in guaranteeing both optimum acquisition quality in multi-pulse NMR and accurate results in quantitative experiments. Most existing methods are based on a series of spectra for which the flip angle of one or more pulses is progressively incremented, implying a significant experiment time. In order to circumvent this drawback, we have previously proposed an approach based on the acquisition of a spin echo and a stimulated echo - the MISSTEC sequence - which requires only 8 s to determine the PW90-1H, while it is several minutes in the case of the use of a nutation curve. In this work, a new sequence for RF calibration is presented: MISSTEC-S. It is derived from the previously proposed MISSTEC sequence, but the observation of echoes in presence of magnetic field gradient is replaced by the observation of FIDs. This modification allows both spectra to be phased, while imposing a strong constraint on the Mixing Time (TM). However, the relationship used to calculate the flip angle is only correct when TM is small enough to neglect longitudinal relaxation during this delay. In order to reduce TM, the first FID is truncated during acquisition and subsequently lengthened using points from the second FID. Results obtained with MISSTEC-S were compared to those obtained from a complete nutation curve and an excellent correlation was observed, although the experimental time to obtain the PW90 is dramatically reduced.

2.
Talanta ; 276: 126157, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38728801

ABSTRACT

Acceleration techniques for one dimensional Nuclear Magnetic Resonance (1D NMR) are very useful, both for NMR enthusiasts and for chemists that use NMR for structural elucidation. To the latter, such techniques need to be straightforward. Recovery time Reduction to Decrease the experimental Duration (R2D2) relies on the incremental reduction of a pulse sequence's Recycle Time (TR). A pseudo-2D spectrum is acquired and after two Fourier transform, extraction and addition of the central rows, a 1D spectrum is obtained. Not only can it be applied to any pulse sequence that contains a TR, but it also requires only a list of recovery times and 2D processes to operate. With this method, we were able to easily reduce the experimental time by a factor of 2 and up to 4 using single-pulse, APT and DEPT 13C sequences. Moreover, R2D2 has the potential to be used on other low abundance nuclei (such as 15N or 2H) and numerous other pulse sequences.

3.
Medicina (Guayaquil) ; 13(1): 41-44, dic. 2007.
Article in Spanish | LILACS | ID: lil-617707

ABSTRACT

Se presenta el caso de un lactante menor, masculino, de un mes de edad que ingresa al servicio de pediatría del hospital “Dr. Abel Gilbert Pontón” con insuficiencia respiratoria grave. La radiología demostró la elevación del diafragma derecho y su evolución satisfactoria inmediata posterior a la intervención quirúrgica de plicatura del diafragma. Con lo que se corrigió el defecto del diafragma que limitaba la capacidad torácica (pulmonar).


Subject(s)
Male , Infant , Congenital Abnormalities , Diaphragmatic Eventration , Infant , Respiratory Distress Syndrome, Newborn
SELECTION OF CITATIONS
SEARCH DETAIL
...