2.
J R Soc Interface ; 11(99)2014 Oct 06.
Article in English | MEDLINE | ID: mdl-25100317

ABSTRACT

Flies use so-called halteres to sense body rotation based on Coriolis forces for supporting equilibrium reflexes. Inspired by these halteres, a biomimetic gimbal-suspended gyroscope has been developed using microelectromechanical systems (MEMS) technology. Design rules for this type of gyroscope are derived, in which the haltere-inspired MEMS gyroscope is geared towards a large measurement bandwidth and a fast response, rather than towards a high responsivity. Measurements for the biomimetic gyroscope indicate a (drive mode) resonance frequency of about 550 Hz and a damping ratio of 0.9. Further, the theoretical performance of the fly's gyroscopic system and the developed MEMS haltere-based gyroscope is assessed and the potential of this MEMS gyroscope is discussed.


Subject(s)
Bioengineering/methods , Biomimetic Materials , Mechanotransduction, Cellular/physiology , Rotation , Wings, Animal/physiology , Animals , Biomechanical Phenomena , Diptera
3.
J R Soc Interface ; 11(97): 20140438, 2014 Aug 06.
Article in English | MEDLINE | ID: mdl-24920115

ABSTRACT

Crickets use so-called clavate hairs to sense (gravitational) acceleration to obtain information on their orientation. Inspired by this clavate hair system, a one-axis biomimetic accelerometer has been developed and fabricated using surface micromachining and SU-8 lithography. An analytical model is presented for the design of the accelerometer, and guidelines are derived to reduce responsivity due to flow-induced contributions to the accelerometer's output. Measurements show that this microelectromechanical systems (MEMS) hair-based accelerometer has a resonance frequency of 320 Hz, a detection threshold of 0.10 ms(-2) and a dynamic range of more than 35 dB. The accelerometer exhibits a clear directional response to external accelerations and a low responsivity to airflow. Further, the accelerometer's physical limits with respect to noise levels are addressed and the possibility for short-term adaptation of the sensor to the environment is discussed.


Subject(s)
Acceleration , Biomimetics/instrumentation , Gryllidae/physiology , Hair/physiology , Mechanotransduction, Cellular/physiology , Micro-Electrical-Mechanical Systems/instrumentation , Transducers, Pressure , Animals , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Models, Biological , Sense Organs/physiology
4.
Nanotechnology ; 20(30): 305304, 2009 Jul 29.
Article in English | MEDLINE | ID: mdl-19581693

ABSTRACT

The fabrication and gas flow characterization of an ultra-thin inorganic nanosieve structured by interference lithography and a bond-micromachining approach are reported. The nanosieve has been observed to exhibit transition gas flow behaviour around atmospheric pressure and ambient temperature. The small lip thickness (45 nm) of the nanopores with respect to their diameter (120 nm) helps in understanding pure transition flow by minimizing interactions between the molecule and inner pore wall. Due to the absence of these collisions, the transition flux is the superimposition of viscous and molecular fluxes without the need for higher-order slip correction. The nanosieve shows a flow selectivity of 3.1 between helium and argon at 20 mbar.

5.
Lab Chip ; 5(3): 326-36, 2005 Mar.
Article in English | MEDLINE | ID: mdl-15726209

ABSTRACT

In this paper the fabrication and electrical characterization of a silicon microreactor for high-temperature catalytic gas phase reactions, like Rh-catalyzed catalytic partial oxidation of methane into synthesis gas, is presented. The microreactor, realized with micromachining technologies, contains silicon nitride tubes that are suspended in a flow channel. These tubes contain metal thin films that heat the gas mixture in the channel and sense its temperature. The metal patterns are defined by using the channel geometry as a shadow mask. Furthermore, a new method to obtain Pt thin films with good adhesive properties, also at elevated temperatures, without adhesion metal is implemented in the fabrication process. Based on different experiments, it is concluded that the electrical behaviour at high temperatures of Pt thin films without adhesion layer is better than that of Pt/Ta films. Furthermore, it is found that the temperature coefficient of resistance (TCR) and the resistivity of the thin films are stable for up to tens of hours when the temperature-range during operation of the microreactor is below the so-called "burn-in" temperature. Experiments showed that the presented suspended-tube microreactors with heaters and temperature sensors of Pt thin films can be operated safely and in a stable way at temperatures up to 700 degrees C for over 20 h. This type of microreactor solves the electrical breakdown problem that was previously reported by us in flat-membrane microreactors that were operated at temperatures above 600 degrees C.


Subject(s)
Biosensing Techniques/instrumentation , Electronics , Microchemistry/instrumentation , Silicon Compounds/chemistry , Temperature , Biosensing Techniques/methods , Catalysis , Equipment Design , Gases/chemistry , Hot Temperature , Microchemistry/methods , Platinum/chemistry , Sensitivity and Specificity , Surface Properties , Tantalum/chemistry
6.
Talanta ; 56(2): 331-9, 2002 Feb 11.
Article in English | MEDLINE | ID: mdl-18968505

ABSTRACT

This paper describes the design, realization and characterization of a micromachined light detection cell. This light detection cell is designed to meet the specifications needed for a micro total analysis system in which ammonia is converted to indophenol blue. The concentration of indophenol blue is measured in a light detection cell. The light detection cell was created using KOH/IPA etching of silicon. The KOH/IPA etchant was a 31 wt.% potassium hydroxide (KOH) solution with 250 ml isopropyl alcohol (IPA) per 1000 ml H(2)O added to it. The temperature of the solution was 50 degrees C. Etching with KOH/IPA results in 45 degrees sidewalls ({110} planes) which can be used for the in- and outcoupling of the light. The internal volume of the realized light detection cell is smaller than 1 mul, enabling measurements on samples in the order of only 1 mul. Measurements were performed on indophenol blue samples in the range of 0.02 to 50 muM. In this range the measurements showed good reproducibility.