Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Orthod ; 40(4): 276-85, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24297959

ABSTRACT

OBJECTIVE: To investigate and compare the effects of superelastic nickel-titanium and multistranded stainless steel archwires on pain during the initial phase of orthodontic treatment. DESIGN: A double-blind two-arm parallel design stratified randomized clinical trial. SETTING: A single centre in India between December 2010 and June 2012. A total of 96 participants (48 male and 48 females; 14.1±2.1 years old) were randomized (stratified on age, sex and initial crowding) to superelastic nickel-titanium or multistranded stainless steel archwire groups using a computer-generated allocation sequence. METHODS: We compared 0.016-inch superelastic nickel-titanium and 0.0175-inch multistranded stainless steel wires in 0.022-inch slot (Roth prescription) preadjusted edgewise appliances. The follow-up period was 14 days. Outcome was assessed with a visual analogue scale at baseline and 32 pre-specified follow-up points. Data was analyzed using mixed-effects model analysis. RESULTS: One participant was lost to follow up and 10 were excluded from the analysis due to bond failure or incomplete questionnaire answers. Ultimately, 85 participants (42 males and 43 females; 14.1±2.0 years old) were analysed for the final results. No statistically significant difference was found for overall pain [F value = 2.65, degrees of freedom (df) = 92.6; P = 0.1071]. However, compared to multistranded stainless steel wires, pain in subjects with superelastic nickel-titanium archwires was significantly greater at 12 h (t = 2.34; P = 0.0193), as well as at day 1 in the morning (t = 2.21, P = 0.0273), afternoon (t = 2.11, P = 0.0346) and at bedtime (t = 2.03, P = 0.042). CONCLUSION: For overall pain, there was no statistically significant difference between the two wires. However, subjects with superelastic nickel-titanium archwires had a significantly higher pain at peak level.


Subject(s)
Dental Alloys/chemistry , Nickel/chemistry , Orthodontic Appliance Design , Orthodontic Wires , Pain/etiology , Stainless Steel/chemistry , Titanium/chemistry , Tooth Movement Techniques/instrumentation , Adolescent , Child , Double-Blind Method , Elasticity , Female , Follow-Up Studies , Humans , Male , Malocclusion/therapy , Orthodontic Brackets , Orthodontic Wires/adverse effects , Pain Measurement , Surface Properties , Time Factors , Tooth Movement Techniques/adverse effects , Visual Analog Scale
SELECTION OF CITATIONS
SEARCH DETAIL
...