Phys Med Biol ; 60(9): 3731-46, 2015 May 07.
Article in English | MEDLINE | ID: mdl-25884892

ABSTRACT

Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [(18)F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.


Subject(s)
Four-Dimensional Computed Tomography/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Setup Errors/prevention & control , Tomography, X-Ray Computed/methods , Humans , Motion , Phantoms, Imaging , Positron-Emission Tomography/methods , Respiration
2.
Australas Phys Eng Sci Med ; 30(4): 344-8, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18274078

ABSTRACT

Lung cancer treatment presents a greater treatment planning and treatment delivery challenge in proton beam therapy compared to conventional photon therapy due to the proton beam's energy deposition sensitivity to the breathing-induced dynamic tissue density variations along the beam path. Four-dimensional computed tomography (4D-CT) has been defined as the explicit inclusion of temporal changes of tumor and normal organ mobility into an image series. It allows more accurate delineation of lung cancer target volumes by suppression of any breathing motion artifacts present in the CT images. It also allows analysis of the tumor's 3D spatial movement within a breathing phase cycle. The motivation for this study was to investigate dosimetric errors caused by lung tumor motion in order to find an optimal method of design for patient compensators and apertures for a passive scattering beam delivery system and treatment of the patient under free breathing conditions. In this study, the maximum intensity projection (MIP) method was compared to patient-specific internal margin designs based on a single breathing phase at the end-of inhale (EOI) or middle-of-exhale (MOE). It was found that MIP method provides superior tumor dose distribution compared to patient-specific internal margin designs derived from 4D-CT.


Subject(s)
Lung Neoplasms/radiotherapy , Proton Therapy , Humans , Imaging, Three-Dimensional , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/physiopathology , Movement , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Respiratory Mechanics , Tomography, X-Ray Computed
3.
Phys Med Biol ; 51(23): 6047-60, 2006 Dec 07.
Article in English | MEDLINE | ID: mdl-17110769

ABSTRACT

Microvascular injury is recognized as a major tissue damage mechanism of ablative cryosurgery. Endothelial cells lining the vessel wall are thought to be the initial target of freezing. However, details of this injury mechanism are not yet completely understood. In this study, ECMatrix 625 was used to mimic the tumour environment and to allow the endothelial cells cultured in vitro to form the tube-like structure of the vasculature. The influence of water dehydration on the integrity of this structure was investigated. It was found that the initial cell shape change was mainly controlled by water dehydration, dependent on the cooling rate, resulting in the shrinkage of cells in the direction normal to the free surface. As the cooling was prolonged and temperature was lowered, further cell shape change could be induced by the chilling effects on intracellular proteins, and focal adhesions to the basement membrane. Quantitative analysis showed that the freezing induced dehydration greatly enhanced the cell surface stresses, especially in the axial direction. This could be one of the major causes of the final breaking of the cell junction and cell detachment.


Subject(s)
Endothelial Cells/cytology , Freezing , Actins/metabolism , Biophysical Phenomena , Biophysics , Cell Membrane/metabolism , Cell Shape , Cells, Cultured , Cryosurgery , Endothelial Cells/metabolism , Endothelium, Vascular/cytology , Endothelium, Vascular/injuries , Endothelium, Vascular/metabolism , Humans , Microcirculation/cytology , Microcirculation/injuries , Microcirculation/metabolism , Models, Biological , Neoplasms/blood supply , Neoplasms/surgery , Surface Tension , Water/metabolism
4.
Phys Med Biol ; 47(13): 2247-61, 2002 Jul 07.
Article in English | MEDLINE | ID: mdl-12164585

ABSTRACT

The merits of intensity-modulated very-high energy electron therapy (VHEET) and intensity-modulated proton therapy (IMPT) in relation to intensity-modulated x-ray therapy (IMXT) with respect to the treatment of the prostate have been quantified. Optimized dose distributions were designed for 5-11 beams of 250 MeV VHEET and 15 MV IMXT as well as 1-9 beam ports of IMPT. In the case of the comparison between 250 MeV VHEET and 15 MV IMXT, it was found that the quality of target coverage achievable with VHEET was comparable to or sometimes better than that provided by IMXT. However, VHEET provided an improvement over IMXT in the dose sparing of the sensitive structures and normal tissues. Compared to IMXT, VHEET decreased the mean rectal dose and bladder dose by up to 10% of the prescribed target dose, while reducing by up to 12% of the prescribed target dose the integral dose to normal tissues. In quantifying the merits of IMPT relative to IMXT, it was found that using intensity-modulated proton beams for inverse planning instead of intensity-modulated photon beams improved target dose homogeneity by up to 1.3% of the prescribed target dose, while reducing the mean rectal dose, bladder dose, and normal tissue integral dose by up to 27%, 30% and 28% of the prescribed target dose respectively. The comparison of optimized planning for IMPT and VHEET showed that the quality of target coverage achievable with IMPT is comparable to or better (by up to 1.3% of the prescribed target dose) than that provided by VHEET. Compared to VHEET, IMPT delivered a mean rectal dose and a bladder dose that was lower by up to 17% and 23% of prescribed target dose respectively, and also reduced the integral dose to normal tissues by up to 17% of the prescribed target dose. These results indicate that of the three modalities the greatest dose escalation will be possible with IMPT, then VHEET, and then IMXT. It follows that IMPT will result in the highest probability of complication-free tumour control, while IMXT will provide the lowest probability.


Subject(s)
Prostatic Neoplasms/radiotherapy , Radiotherapy, Conformal/instrumentation , Radiotherapy, High-Energy/instrumentation , Dose-Response Relationship, Radiation , Electrons/therapeutic use , Humans , Male , Phantoms, Imaging , Proton Therapy , Quality Control , Radiation Dosage , Radiotherapy Planning, Computer-Assisted/instrumentation , X-Rays
5.
Phys Med Biol ; 47(8): 1285-301, 2002 Apr 21.
Article in English | MEDLINE | ID: mdl-12030556

ABSTRACT

This work evaluates the potential of very high energy (50-250 MeV) electron beams for dose conformation and identifies those variables that influence optimized dose distributions for this modality. Intensity-modulated plans for a prostate cancer model were optimized as a function of the importance factors, beam energy and number of energy bins, number of beams, and the beam orientations. A trial-and-error-derived constellation of importance factors for target and sensitive structures to achieve good conformal dose distributions was 500, 50, 10 and I for the target, rectum, bladder and normal tissues respectively. Electron energies greater than 100 MeV were found to be desirable for intensity-modulated very high energy electron therapy (VHEET) of prostate cancer. Plans generated for lower energy beams had relatively poor conformal dose distributions about the target region and delivered high doses to sensitive structures. Fixed angle beam treatments utilizing a large number of fields in the range 9-21 provided acceptable plans. Using more than 21 beams at fixed gantry angles had an insignificant effect on target coverage, but resulted in an increased dose to sensitive structures and an increased normal tissue integral dose. Minor improvements in VHEET plans utilizing a 'small' number (< or =9) of beams may be achieved if, in addition to intensity modulation, energy modulation is implemented using a small number (< or =3) of beam energies separated by 50 to 100 MeV. Rotation therapy provided better target dose homogeneity but unfortunately resulted in increased rectal dose, bladder dose and normal tissue integral dose relative to the 21-field fixed angle treatment plan. Modulation of the beam energy for rotation therapy had no beneficial consequences on the optimized dose distributions. Lastly, selection of beam orientations influenced the optimized treatment plan even when a large number of beams (approximately 15) were employed.


Subject(s)
Electrons , Radiotherapy, Conformal/instrumentation , Radiotherapy, Conformal/methods , Models, Statistical , Monte Carlo Method , Radiometry
6.
Phys Med Biol ; 46(7): 1799-814, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11474926

ABSTRACT

We demonstrate that it is possible to simultaneously optimize multiple cryoprobe placements and their thermal protocol for one freeze-thaw cycle. A numerical optimization algorithm is used and three different forms of objective function are examined in terms of algorithm convergence rate, minimum value of the chosen objective function, temperature-volume histograms and isotherm distributions. The optimization results depend on the initial values of the variables, the form of the objective function, optimization goals and the mathematical method adopted for gradient calculation. The proposed optimization model offers significant advantages over the previously reported semi-empirical approach to conformal cryotherapy, such as the ability to handle an unlimited number of variables and eliminating the need for the user input between iterations, thereby reducing, if not removing, the subjectivity of cryosurgery treatment planning.


Subject(s)
Cryosurgery/instrumentation , Cryosurgery/methods , Algorithms , Humans , Models, Statistical , Models, Theoretical , Temperature , Time Factors
7.
Med Phys ; 28(6): 1125-37, 2001 Jun.
Article in English | MEDLINE | ID: mdl-11439482

ABSTRACT

A time dependent three-dimensional finite difference model of iceball formation about multiple cryoprobes has been developed and compared to experimental data. Realistic three-dimensional probe geometry is specified and the number of cryoprobes, the cryoprobe cooling rates, and the locations of the probes are arbitrary inputs by the user. The simulation accounts for observed longitudinal thermal gradients along the cryoprobe tips. Thermal histories for several points around commercially available cryoprobes have been predicted within experimental error for one, three, and five probe configurations. The simulation can be used to generate isotherms within the iceball at arbitrary times. Volumes enclosed by the iceball and any isotherms may also be computed to give the ablative ratio, a measure of the iceball's killing efficiency. This ratio was calculated as the volume enclosed by a critical isotherm divided by the total volume of the iceball for assumed critical temperatures of -20 and -40 degrees C. The ablative ratio for a single probe is a continuously decreasing function of time but when multiple probe configurations are used the ablative ratio increases to a maximum and then essentially plateaus. Maximum values of 0.44 and 0.55 were observed for three and five probe configurations, respectively, with an assumed critical temperature of -20 degrees C. Assuming a critical temperature of -40 degrees C, maximum ablative ratios of 0.21 and 0.3 for three and five probe configurations, respectively, were observed.


Subject(s)
Cryosurgery/statistics & numerical data , Biophysical Phenomena , Biophysics , Computer Simulation , Cryosurgery/instrumentation , Humans , Ice , Male , Models, Theoretical , Prostatic Neoplasms/surgery , Temperature , Thermodynamics , Thermometers
8.
Phys Med Biol ; 45(10): 2913-30, 2000 Oct.
Article in English | MEDLINE | ID: mdl-11049180

ABSTRACT

The 'monoenergetic' electron loss model was derived in a previous work to account for pathlength straggling in the Fermi-Eyges pencil beam problem. In this paper, we extend this model to account for energy-loss straggling and secondary knock-on electron transport in order to adequately predict a depth dose curve. To model energy-loss straggling, we use a weighted superposition of a discrete number of monoenergetic pencil beams with different initial energies where electrons travel along the depth-energy characteristics in the continuous slowing down approximation (CSDA). The energy straggling spectrum at depth determines the weighting assigned to each monoenergetic pencil beam. Supplemented by a simple transport model for the secondary knock-on electrons, the 'energy-dependent' electron loss model predicts both lateral and depth dose distributions from the electron pencil beams in good agreement with Monte Carlo calculations and measurements. The calculation of dose distribution from a pencil beam takes 0.2 s on a Pentium III 500 MHz computer. Being computationally fast, the 'energy-dependent' electron loss model can be used for the calculation of 3D energy deposition kernels in dose optimization schemes without using precalculated or measured data.


Subject(s)
Electrons , Radiotherapy, Conformal/methods , Algorithms , Computer Simulation , Models, Statistical , Monte Carlo Method
9.
Med Phys ; 27(8): 1800-3, 2000 Aug.
Article in English | MEDLINE | ID: mdl-10984226

ABSTRACT

Neutrons are associated with therapeutic high energy x-ray beams as a contaminant that contributes significant unwanted dose to the patient. Measurement of both photon and neutron scattered dose at the position of a fetus from chest irradiation by a large field 18 MV x-ray beam was performed using an ionization chamber and superheated drop detector, respectively. Shielding construction to reduce this scattered dose was investigated using both lead sheet and borated polyethylene slabs. A 7.35 cm lead shield reduced the scattered photon dose by 50% and the scattered neutron dose by 40%. Adding 10 cm of 5% borated polyethylene to this lead shield reduced the scattered neutron dose by a factor of 7.5 from the unshielded value. When the 5% borated polyethylene was replaced by the same thickness of 30% borated polyethylene there was no significant change in the reduction of neutron scatter dose. The most efficient shield studied reduced the neutron scatter dose by a factor of 10. The results indicate that most of the scattered neutrons present at the position of the fetus produced by an 18 MV x-ray beam are of low energy and in the thermal to 0.57 MeV range since lead is almost transparent to neutrons with energies lower than 0.57 MeV. This article constitutes the first report of an effective shield to reduce neutron dose at the fetus when treating a pregnant woman with a high energy x-ray beam.


Subject(s)
Fetus/radiation effects , Neutrons/therapeutic use , Radiometry/methods , Radiotherapy, High-Energy/methods , Fast Neutrons , Female , Fetal Diseases/etiology , Humans , Lead , Neutrons/adverse effects , Particle Accelerators , Photons/adverse effects , Photons/therapeutic use , Polyethylene , Pregnancy , Radiation Protection , Scattering, Radiation , X-Rays/adverse effects
10.
Med Phys ; 27(9): 2133-45, 2000 Sep.
Article in English | MEDLINE | ID: mdl-11011743

ABSTRACT

A transport algorithm called the proton loss (PL) model is developed for proton pencil beams of therapeutic energies. The PL model takes into account inelastic nuclear reactions, pathlength straggling, and energy-loss straggling and predicts the 3D dose distribution from a proton pencil beam. In proton beams, the multiple scattering and ionizational energy loss processes approach their diffusional limit where scattering and energy loss probability densities become Gaussian. Therefore we chose to derive the PL model from the Fermi-Eyges diffusional multiple scattering theory and the Gaussian theory of energy straggling. We first introduce a generalization of the Fermi-Eyges equation for proton pencil beams, labeled the proton loss (PL) transport equation. This new equation includes terms that model inelastic nuclear reactions as a depth-dependent absorption and pathlength straggling as a quasi-absorption. Then energy straggling is taken into account by using a weighted superposition of a discrete number of elementary pencil beams. These elementary pencil beams have different initial energies and lose energy according to the CSDA, thus they have different ranges of penetration. A final solution for the proton beam transport is obtained as a linear combination of elementary pencil beam solutions with weights defined by the Gaussian evolution of the proton energy spectrum with depth. A numerical comparison of the dose distribution predictions of the PL model with measurements and PTRAN Monte Carlo simulations indicates the model is both computational fast and accurate.


Subject(s)
Protons , Radiometry/methods , Algorithms , Monte Carlo Method , Normal Distribution , Radiotherapy Planning, Computer-Assisted/methods , Reproducibility of Results , Scattering, Radiation , Time Factors
11.
Phys Med Biol ; 45(5): 1085-98, 2000 May.
Article in English | MEDLINE | ID: mdl-10843092

ABSTRACT

A model is presented for treatment planning of multiprobe cryosurgery. In this model a thermal simulation algorithm is used to generate temperature distribution from cryoprobes, visualize isotherms in the anatomical region of interest (ROI) and provide tools to assist estimation of the amount of freezing damage to the target and surrounding normal structures. Calculations may be performed for any given freezing time for the selected set of operation parameters. The thermal simulation is based on solving the transient heat conduction equation using finite element methods for a multiprobe geometry. As an example, a semi-empirical optimization of 2D placement of six cryoprobes and their thermal protocol for the first freeze cycle is presented. The effectiveness of the optimized treatment protocol was estimated by generating temperature-volume histograms and calculating the objective function for the anatomy of interest. Two phantom experiments were performed to verify isotherm locations predicted by calculations. A comparison of the predicted 0 degrees C isotherm with the actual iceball boundary imaged by x-ray CT demonstrated a spatial agreement within +/-2 mm.


Subject(s)
Cryosurgery/methods , Algorithms , Biophysical Phenomena , Biophysics , Cryosurgery/adverse effects , Cryosurgery/statistics & numerical data , Humans , Male , Models, Biological , Phantoms, Imaging , Prostate/surgery , Temperature , Urethra/injuries
12.
Phys Med Biol ; 45(5): N53-59, 2000 May.
Article in English | MEDLINE | ID: mdl-10843116

ABSTRACT

Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent.


Subject(s)
Cryotherapy/methods , Tomography, X-Ray Computed/methods , Biophysical Phenomena , Biophysics , Cryotherapy/instrumentation , Cryotherapy/statistics & numerical data , Humans , Phantoms, Imaging , Tomography, X-Ray Computed/statistics & numerical data
13.
Phys Med Biol ; 45(2): 255-65, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10701502

ABSTRACT

The perturbation correction factor gamma(p) is defined as the deviation of the absorbed dose in the medium from that predicted by the Spencer-Attix extension of the Bragg-Gray cavity theory where the medium occupies exactly the same volume as the solid state cavity and the electron fluence energy spectrum in the cavity is identical in shape, but not necessarily in magnitude, to that in the medium. The value of gamma(p) has been examined for TL detectors irradiated in megavoltage electron beams (5-20 MeV) using the EGS4 Monte Carlo code. LiF and CaF2 solid state detectors simulated were standard size discs of thickness 1 mm and diameter 3.61 mm irradiated in a water phantom with their centres at d(max) or close to it. Values of gamma(p) for LiF ranged from 0.998 +/- 0.005 to 0.994 +/- 0.005 for electron beams with initial energies of 5 and 20 MeV respectively. For CaF2 the corresponding values were 0.956 +/- 0.006 to 0.989 +/- 0.006 for the same size cavities irradiated at the same depth. EGS4 Monte Carlo simulations demonstrate that the total electron fluence (primary electrons and delta-rays) in these solid state detector materials is significantly different from that in water for the same incident electron energy and depth of irradiation. Thus the Spencer-Attix assumption that the electron fluence energy spectrum in the cavity is identical in shape to that in the medium is violated. Differences in the total electron fluence give rise to electron fluence perturbation correction factors which were up to 5% less than unity for CaF2, indicating a strong violation in this case, but were generally less than 1% for LiF. It is the density of the cavity which perturbs the electron fluence, but it is actually the atomic number differences between the medium and cavity that are responsible for the large electron fluence perturbation correction factors for detectors irradiated close to d(max) because the atomic number affects the change in stopping power with energy. When correction is made for the difference between the electron fluence spectrum in the uniform water phantom and the solid state cavity, the Spencer-Attix cavity equation predicts the dose to water within 0.3% in both clinical and monoenergetic electron beams. Harder's formulation for computing the average mass collision stopping power of water to calcium fluoride, surprisingly, requires perturbation correction factors that are closer to unity than those determined using the Spencer-Attix integrals at depths close to d(max).


Subject(s)
Electrons , Models, Theoretical , Radiation Monitoring/methods , Radiometry/methods , Monte Carlo Method , Phantoms, Imaging , Reproducibility of Results , Software , Water
14.
Phys Med Biol ; 45(2): 267-77, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10701503

ABSTRACT

Dose perturbation correction factors, gamma(p), for LiF, CaF2 and Li2B4O7 solid state detectors have been determined using the EGS4 Monte Carlo code. Each detector was simulated in the form of a disc of diameter 3.61 mm and thickness 1 mm irradiated in a clinical kilovoltage photon beam at a depth of 1 cm in a water phantom. The perturbation correction factor gamma(p) is defined as the deviation of the absorbed dose ratio from the average mass energy absorption coefficient ratio of water to the detector material, (mu(en)/rho)med,det, which is evaluated assuming that the photon fluence spectrum in the medium and in the detector material are identical. We define another mass energy absorption coefficient ratio, (kappa(en)/rho)med,det, which is evaluated using the actual photon fluence spectrum in the medium and detector for LiF and CaF2 rather than assuming they are identical. (kappa(en)/rho)med,det predicts the average absorbed dose ratio of the medium to the detector material within 0.3%. When the difference in atomic number between the cavity and the phantom material is large then their photon fluence spectra will differ substantially resulting in a difference between (kappa(en)/rho)med,det and (mu(en)/rho)med,det. The value of gamma(p) calculated using (mu(en)/rho)med,det is up to 27% greater than unity for a cavity of CaF2 in 50 kV x-rays. When the atomic number of the medium and detector are similar, their photon fluence spectra are similar, and the difference between (kappa(en)/rho)med,det and (mu(en)/rho)med,det is small. For instance their difference for LiF is less than 2%. The average mass energy absorption coefficient ratio, (mu(en)(E)/rho)w,LiF, evaluated using the mean or representative energy, E, is up to 8% different from (mu(en)/rho)w,LiF. For calcium fluoride the difference between (mu(en)/rho)w,CaF2 and (mu(en)(E)/rho)w,CaF2 is up to 42% in the energy range studied.


Subject(s)
Models, Theoretical , Photons , Radiation Monitoring/methods , Radiometry/methods , Monte Carlo Method , Phantoms, Imaging , Radiometry/instrumentation , Reproducibility of Results , Software , Water
15.
Med Phys ; 27(12): 2780-7, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11190961

ABSTRACT

Differences in depth dose curves for a 78 MeV unmodulated proton beam were measured with four commercially available ionization chambers. Measurements were performed both in water and in a commercially available solid water phantom. A depth scaling factor (Cpl) was determined from the ratio of depths distal to the Bragg peak where the dose is reduced to 80% of the maximum dose in water and in the solid water phantom. This scaling factor provides good agreement between the ionization curves at all depths in water and in this solid water phantom. There is no significant difference in the value of the depth scaling factor between the ratios (R80wat/R80med) and (R50wat/R50med), or (R100wat/R100med) for 78 MeV unmodulated proton beams. The depth scaling factor for this commercially available solid water phantom is 1.023. An effective point of measurement for a cylindrical ionization chamber was found to be slightly greater than the 50% of the cavity radius proposed by the AAPM-TG25 dosimetry protocol for electron beams and amounts to 62.5% of the cavity radius of cylindrical ionization chambers. The ion collection efficiency, Pion, and the polarity correction factor, Ppol, for all the ionization chambers studied are within 1% and 0.4% of unity, respectively. Absolute doses measured with a parallel plate ionization chamber in water and in the solid water phantom show that the doses measured in the solid water phantom are 1.4% +/- 0.5% lower than in water. The dose rate dependent response of the beam line monitor chamber was also investigated. Agreement between all the chambers was within 1.5% at the dose rates studied but the results showed that all four ionization chambers are less dose rate dependent than the monitor chamber.


Subject(s)
Protons , Radiotherapy/instrumentation , Radiotherapy/methods , Algorithms , Electrons , Phantoms, Imaging , Water
16.
Med Phys ; 26(11): 2503-7, 1999 Nov.
Article in English | MEDLINE | ID: mdl-10587240

ABSTRACT

A detailed Monte Carlo study of the PTW-diamond solid state detector response in megavoltage photon beams (60Co gamma rays to 25 MV x rays) has been performed with the EGS4 Monte Carlo Code. The sensitive volume of the diamond detector is a disk of diameter 4.4 mm and thickness 0.40 mm. The phantom material was water and the irradiation depth was usually 3 cm but additional simulations were performed at six other depths for the 10 and 25 MV x rays. Results show that the PTW-diamond detector response per unit of absorbed dose is constant within 1% for photon beam energies ranging from 60Co gamma rays to 25 MV x rays. Accurate depth dose curves for 10 and 25 MV x-ray beams may be measured with the diamond detector since the response per unit of absorbed dose at different depths in a water phantom is also constant to within 1% for depths ranging from 3 to 25 cm and field sizes ranging from 2.5 cm by 2.5 cm to 10 cm by 10 cm. An examination of the difference between the PTW-diamond detector and the wall-less form of the detector (e.g., TLDs) revealed that there is no significant difference in their response in megavoltage photon beams. This implies that the encapsulation of the diamond dosimeter causes less than a 1.3% change in its response for these megavoltage photon beams. Analysis of the total dose deposited in the sensitive volume of the detector shows that the PTW-diamond detector behaves as an intermediate-sized cavity, not a simple Bragg-Gray cavity, since the dose contribution from photon interactions within the cavity (alpha(c)) to the total cavity dose is 8% for 25 MV x rays and increases to 42% for 60Co gamma rays.


Subject(s)
Diamond , Models, Statistical , Photons , Radiotherapy Dosage , Calibration , Electrons , Monte Carlo Method , Phantoms, Imaging
17.
J Surg Oncol ; 71(2): 106-11, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10389867

ABSTRACT

BACKGROUND AND OBJECTIVES: Advances in the technology of cryomachines in the last 10 years have led to the development of both liquid nitrogen and argon-based Joule-Thompson cryomachines. Theoretical and practical evaluation of the CMS Accuprobe and the ENDOcare CRYOcare was performed as respective examples of these technologies. METHODS: Thermal gradients were calculated about both probes for the best case scenario of probe surface temperature equaling that of the cryogen used. Also, experimental evaluation in gelatin phantoms was performed with five probe arrays. RESULTS: Theoretically, a liquid nitrogen-cooled probe provides only a slight advantage over one cooled with liquid argon. However, the experimental performance evaluation demonstrated that the CRYOcare system creates an iceball faster with steeper internal temperature gradients than the Accuprobe. Further, temperature outputs from the Accuprobe were shown to be in error, likely due to the position of the thermocouple within the probe. CONCLUSIONS: Cryomachine performance is determined more by technological innovations than by cryogen temperature. Thermocouple monitoring is urged for users of the Accuprobe.


Subject(s)
Cryosurgery/instrumentation , Cryosurgery/standards , Thermodynamics , Argon , Cryosurgery/methods , Evaluation Studies as Topic , Humans , Nitrogen
18.
Med Phys ; 26(5): 839-44, 1999 May.
Article in English | MEDLINE | ID: mdl-10360550

ABSTRACT

The EGS4 Monte Carlo code has been used to investigate the response of a PTW/diamond detector irradiated in both clinical and monoenergetic megavoltage electron beams ranging in energy from 5 to 20 MeV. The sensitive volume of the PTW/diamond detector simulated has a thickness of 0.4 mm and a diameter of 4.4 mm. Irradiation was simulated at various depths in a water phantom. The results show that the PTW/diamond detector has a constant response (within 1.0%) in electron beams if irradiated at depths closed to dmax, and its response is almost independent of irradiation depth or incident electron energy (within 3%). A detailed examination of the average detector dose shows that the sensitive volume of the PTW/diamond detector acts as a Spencer-Attix cavity within 1%. The encapsulation of the bare diamond detector with low-Z epoxy and polystyrene wall material does not affect its response in electron beams. The difference in response between the unencapsulated (TLD) and the encapsulated form of the detector is less than 0.5% for all depths over electron energy range investigated.


Subject(s)
Diamond , Monte Carlo Method , Radiometry , Tomography, X-Ray Computed/methods
19.
Med Phys ; 26(5): 845-7, 1999 May.
Article in English | MEDLINE | ID: mdl-10360551

ABSTRACT

Neutron dose equivalent measurements were performed in and around an 18 MV x-ray beam using superheated drop detectors (SDD) and phosphorous pentoxide (P2O5) powder. The neutron dose equivalent profiles for various field sizes of 10 X 10 cm2, 20 X 20 cm2, and 30 X 30 cm2 were measured. The results measured with the P2O5 were checked for any gross systematic errors by comparing with the published results computed by using Monte Carlo calculations. A comparison was then made between the neutron dose equivalent profiles measured with the P2O5 and the SDD. The results of this comparison show that the neutron dose equivalents measured with the two types of detectors agree with each other for measurements about 20 cm away from the beam edges. However, in and near the beam edges the SDD measurements are upto 50% less than the neutron dose equivalents measured using P2O5 for the 18 MV x-ray beam.


Subject(s)
Neutrons , Phosphorus Compounds/chemistry , Radiometry , X-Rays
20.
Phys Med Biol ; 43(11): 3309-24, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9832018

ABSTRACT

X-ray CT is able to image the internal architecture of frozen tissue. Phantoms of distilled water, a saline-gelatin mixture, lard and a calf liver-gelatin suspension cooled by a plastic tube acting as a long liquid nitrogen cryoprobe were used to study the relationship between Hounsfield unit (HU) values and temperature. There is a signature change in HU value from unfrozen to completely frozen tissue. No discernible relation exists between temperature in a completely frozen tissue and its HU value for the temperature range achieved with commercial cryoprobes. However, such a relation does exist in the typically narrow region of phase change and it is this change in HU value that is the parameter of concern for quantitative monitoring of the freezing process. Calibration of temperature against change in HU value allows a limited set of isotherms to be generated in the phase change region for direct monitoring of iceball growth. The phase change temperature range, mid-phase change temperature and the absolute value of HU change from completely frozen to unfrozen tissue are shown to be sensitive to the medium. Modelling of the temperature distribution within the region of completely frozen phantom using the infinite cylinder solution to the Fourier heat equation allows the temperature history of the phantom to be predicted. A set of isotherms, generated using a combination of thermal modelling and calibrated HU values demonstrates the feasibility of routine x-ray CT assisted cryotherapy. Isotherm overlay will be a major aid to the cryosurgeon who adopts a fixed target temperature as the temperature below which there is a certainty of ablation of the diseased tissue.


Subject(s)
Cryosurgery , Tomography, X-Ray Computed , Animals , Biophysical Phenomena , Biophysics , Cattle , Humans , Ice , In Vitro Techniques , Monitoring, Physiologic , Phantoms, Imaging , Temperature