Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
Add more filters










Publication year range
2.
J Phys Chem B ; 126(12): 2420-2429, 2022 Mar 31.
Article in English | MEDLINE | ID: mdl-35315675

ABSTRACT

Liquid-liquid extraction (LLE), the go-to process for a variety of chemical separations, is limited by spontaneous organic phase splitting upon sufficient solute loading, called third phase formation. In this study we explore the applicability of critical phenomena theory to gain insight into this deleterious phase behavior with the goal of improving separations efficiency and minimizing waste. A series of samples representative of rare earth purification were constructed to include each of one light and one heavy lanthanide (cerium and lutetium) paired with one of two common malonamide extractants (DMDOHEMA and DMDBTDMA). The resulting postextraction organic phases are chemically complex and often form rich hierarchical structures whose statics and dynamics near the critical point were probed herein with small-angle X-ray scattering and high-speed X-ray photon correlation spectroscopy. Despite their different extraction behaviors, all samples show remarkably similar critical behavior with exponents well described by classical critical point theory consistent with the 3D Ising model, where the critical behavior is characterized by fluctuations with a single diverging length scale. This unexpected result indicates a significant reduction in relevant chemical parameters at the critical point, indicating that the underlying behavior of phase transitions in LLE rely on far fewer variables than are generally assumed. The obtained scalar order parameter is attributed to the extractant fraction of the extractant/diluent mixture, revealing that other solution components and their respective concentrations simply shift the critical temperature but do not affect the nature of the critical fluctuations. These findings point to an opportunity to drastically simplify studies of liquid-liquid phase separation and phase diagram development in general while providing insights into LLE process improvement.

3.
Phys Rev Lett ; 125(12): 125504, 2020 Sep 18.
Article in English | MEDLINE | ID: mdl-33016761

ABSTRACT

The advent of high-speed x-ray photon correlation spectroscopy now allows the study of critical phenomena in fluids to much smaller length scales and over a wider range of temperatures than is possible with dynamic light scattering. We present an x-ray photon correlation spectroscopy study of critical fluctuation dynamics in a complex fluid typical of those used in liquid-liquid extraction (LLE) of ions, dodecane-DMDBTDMA with extracted aqueous Ce(NO_{3})_{3}. We observe good agreement with both static and dynamic scaling without the need for significant noncritical background corrections. Critical exponents agree with 3D Ising values, and the fluctuation dynamics are described by simple exponential relaxation. The form of the dynamic master curve deviates somewhat from the Kawasaki result, with a more abrupt transition between the critical and noncritical asymptotic behavior. The concepts of critical phenomena thus provide a quantitative framework for understanding the structure and dynamics of LLE systems and a path forward to new LLE processes.

4.
Phys Rev Lett ; 109(20): 207801, 2012 Nov 16.
Article in English | MEDLINE | ID: mdl-23215523

ABSTRACT

The surface dynamics of thin molten polystyrene films supported by nanoscale periodic silicon line-space gratings were investigated with x-ray photon correlation spectroscopy. Surface dynamics over these nanostructures exhibit high directional anisotropy above certain length scales, as compared to surface dynamics over flat substrates. A cutoff length scale in the dynamics perpendicular to the grooves is observed. This marks a transition from standard over-damped capillary wave behavior to suppressed dynamics due to substrate interactions.


Subject(s)
Models, Chemical , Nanostructures/chemistry , Polystyrenes/chemistry , Anisotropy , Microscopy, Atomic Force/methods , Photoelectron Spectroscopy/methods , Silicon/chemistry , Surface Properties
5.
J Synchrotron Radiat ; 18(Pt 6): 823-34, 2011 Nov.
Article in English | MEDLINE | ID: mdl-21997906

ABSTRACT

The newly introduced coherence-based technique of X-ray near-field speckle (XNFS) has been implemented at 8-ID-I at the Advanced Photon Source. In the near-field regime of high-brilliance synchrotron X-rays scattered from a sample of interest, it turns out that, when the scattered radiation and the main beam both impinge upon an X-ray area detector, the measured intensity shows low-contrast speckles, resulting from interference between the incident and scattered beams. A micrometer-resolution XNFS detector with a high numerical aperture microscope objective has been built and its capability for studying static structures and dynamics at longer length scales than traditional far-field X-ray scattering techniques is demonstrated. Specifically, the dynamics of dilute silica and polystyrene colloidal samples are characterized. This study reveals certain limitations of the XNFS technique, especially in the characterization of static structures, which is discussed.

6.
Rev Sci Instrum ; 82(7): 075109, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21806229

ABSTRACT

We present a data acquisition system to perform on-the-fly background subtraction and lower-level discrimination compression of streaming x-ray photon correlation spectroscopy data from a fast charge-coupled device (CCD) area detector. The system is built using a commercial frame grabber with an on-board field-programmable gate array. The system is capable of continuously processing at least 60 CCD frames per second each consisting of 1024 × 1024 16-bit pixels with ≲ 15,000 photon hits per frame at a maximum compression factor of ≈95%.

7.
Phys Rev Lett ; 106(18): 188301, 2011 May 06.
Article in English | MEDLINE | ID: mdl-21635129

ABSTRACT

Combined small angle x-ray scattering and x-ray photon correlation spectroscopy studies of moderately concentrated bimodal hard-sphere colloidal suspensions in the fluid phase show that depletion-induced demixing introduces spatially heterogeneous dynamics with two distinct time scales. The adhesive nature, as well as the mobility, of the large particles is determined by the level of interaction within the monomodal domains. This interaction is driven by osmotic forces, which are governed by the relative concentration of the constituents.


Subject(s)
Colloids/chemistry , Suspensions/chemistry , Molecular Dynamics Simulation , Osmotic Pressure , Particle Size , Photons , Spectrum Analysis , Time Factors , X-Rays
8.
J Synchrotron Radiat ; 17(4): 451-5, 2010 Jul.
Article in English | MEDLINE | ID: mdl-20567076

ABSTRACT

Micro-fabricated bi-prisms have been used to create an interference pattern from an incident hard X-ray beam, and the intensity of the pattern probed with fluorescence from a 30 nm-thick metal film. Maximum fringe visibility exceeded 0.9 owing to the nano-sized probe and the choice of single-crystal prism material. A full near-field analysis is necessary to describe the fringe field intensities, and the transverse coherence lengths were extracted at APS beamline 8-ID-I. It is also shown that the maximum number of fringes is dependent only on the complex refractive index of the prism material.

9.
J Synchrotron Radiat ; 17(3): 314-20, 2010 May.
Article in English | MEDLINE | ID: mdl-20400828

ABSTRACT

Moderate-demagnification higher-order silicon kinoform focusing lenses have been fabricated to facilitate small-angle X-ray photon correlation spectroscopy (XPCS) experiments. The geometric properties of such lenses, their focusing performance and their applicability for XPCS measurements are described. It is concluded that one-dimensional vertical X-ray focusing via silicon kinoform lenses significantly increases the usable coherent flux from third-generation storage-ring light sources for small-angle XPCS experiments.

10.
J Synchrotron Radiat ; 16(Pt 1): 8-13, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19096168

ABSTRACT

Motivated by the anticipated advantageous performance of diamond kinoform refractive lenses for synchrotron X-ray radiation studies, this report focuses on progress in designing, nanofabricating and testing of their focusing performance. The method involves using lift-off and plasma etching to reproduce a planar definition of numerically determined kinoform refractive optics. Tests of the focusing action of a diamond kinoform refractive lens at the APS 8-ID-I beamline demonstrate angular control of the focal spot.

11.
Phys Rev Lett ; 101(11): 115501, 2008 Sep 12.
Article in English | MEDLINE | ID: mdl-18851293

ABSTRACT

Changes to the structure of polystyrene melt films as measured through the spectrum of density fluctuations have been observed as a function of film thickness down to the polymer radius of gyration (Rg). Films thicker than 4Rg show bulklike density fluctuations. Thinner films exhibit a peak in S(q) near q=0 which grows with decreasing thickness. This peak is attributed to a decreased interpenetration of chains resulting in an enhanced compressibility. Measurements were made using small angle x-ray scattering in a standing wave geometry designed to enhance scattering from the interior of the film compared to interface scattering.

12.
Phys Rev Lett ; 100(4): 045701, 2008 Feb 01.
Article in English | MEDLINE | ID: mdl-18352302

ABSTRACT

The onset of structural arrest and glass formation in a concentrated suspension of silica nanoparticles in a water-lutidine binary mixture near its consolute point is studied by exploiting the near-critical fluid degrees of freedom to control the strength of an attraction between particles and multispeckle x-ray photon correlation spectroscopy to determine the particles' collective dynamics. This model system undergoes a glass transition both on cooling and on heating, and the intermediate liquid realizes unusual logarithmic relaxations. How vitrification occurs for the two different glass transitions is characterized in detail and comparisons are drawn to recent theoretical predictions for glass formation in systems with attractive interactions.

13.
Nature ; 447(7140): 68-71, 2007 May 03.
Article in English | MEDLINE | ID: mdl-17476263

ABSTRACT

Measurements of magnetic noise emanating from ferromagnets owing to domain motion were first carried out nearly 100 years ago, and have underpinned much science and technology. Antiferromagnets, which carry no net external magnetic dipole moment, yet have a periodic arrangement of the electron spins extending over macroscopic distances, should also display magnetic noise. However, this must be sampled at spatial wavelengths of the order of several interatomic spacings, rather than the macroscopic scales characteristic of ferromagnets. Here we present a direct measurement of the fluctuations in the nanometre-scale superstructure of spin- and charge-density waves associated with antiferromagnetism in elemental chromium. The technique used is X-ray photon correlation spectroscopy, where coherent X-ray diffraction produces a speckle pattern that serves as a 'fingerprint' of a particular magnetic domain configuration. The temporal evolution of the patterns corresponds to domain walls advancing and retreating over micrometre distances. This work demonstrates a useful measurement tool for antiferromagnetic domain wall engineering, but also reveals a fundamental finding about spin dynamics in the simplest antiferromagnet: although the domain wall motion is thermally activated at temperatures above 100 K, it is not so at lower temperatures, and indeed has a rate that saturates at a finite value-consistent with quantum fluctuations-on cooling below 40 K.

14.
Phys Rev Lett ; 97(6): 066102, 2006 Aug 11.
Article in English | MEDLINE | ID: mdl-17026180

ABSTRACT

X-ray photon correlation spectroscopy was used to characterize the wave vector- and temperature-dependent dynamics of spontaneous thermal fluctuations in a sponge (L3) phase that occurs in a blend of a symmetric poly(styrene-ethylene/butylene-styrene) triblock copolymer with a polystyrene homopolymer. Measurements of the intermediate scattering function reveal a crossover from stretched- to compressed-exponential relaxations as the temperature is lowered from 180 to 120 degrees C.

15.
Phys Rev Lett ; 84(4): 785-8, 2000 Jan 24.
Article in English | MEDLINE | ID: mdl-11017372

ABSTRACT

X-ray photon correlation spectroscopy and small-angle scattering measurements are presented of the dynamics and structure of concentrated suspensions of charge-stabilized polystyrene latex spheres dispersed in glycerol, for volume fractions from 3% to 52%. The static structures of the suspensions show essentially hard-sphere behavior, and the short-time dynamics shows good agreement with predictions for the wave-vector-dependent collective diffusion coefficient. However, the intermediate scattering function is found to violate a scaling behavior found previously for a sterically stabilized hard-sphere suspension.

16.
J Synchrotron Radiat ; 5(Pt 1): 37-47, 1998 Jan 01.
Article in English | MEDLINE | ID: mdl-16687799

ABSTRACT

A simple approach for producing a high-coherent-flux X-ray beam for small-angle-scattering studies used at the Troika beamline of the European Synchrotron Radiation Facility is reported. For such small-angle studies it is permissible to reduce the longitudinal coherence .length of the beam, thus increasing the energy bandpass and intensity of the beam, because there is only a small optical path-length difference. By using mirrors and filters to cut unwanted energies from the undulator harmonic structure, a high-flux beam of >10(9) photons s(-1) through a 5 micron-diameter pinhole at 8.2 keV with a bandpass of 1.3% can be produced. The coherent properties of this beam have been measured by analyzing a static speckle pattern from an aerogel sample imaged by a directly illuminated CCD camera. The speckle size and contrast are compared with the expected values based on a statistical analysis of the intensity distribution of speckle patterns obtained using partially coherent conditions. The expected widths of the spatial autocorrelation are found, but there is an apparent incoherent fraction of the beam which reduces the measured contrast. The method presented is to be used as a tool to optimize conditions for diffraction experiments using coherent X-rays.

SELECTION OF CITATIONS
SEARCH DETAIL
...