1.
Appl Radiat Isot ; 207: 111235, 2024 May.
Article in English | MEDLINE | ID: mdl-38430824

ABSTRACT

The use of radiopharmaceuticals has gained a special place in the diagnosis and treatment of cancers and evaluation of the function of different organs of the body. In this study, the absorbed dose distribution of organs after injection of 188Re-Mu-9 has been investigated using MIRD method and MCNP-4C simulation code. The 188Re-Mu-9 labeled was injected the mouse body and the amount of 188Re-labeled accumulation was evaluated after 1, 4 and 2 4 h. Having a map of the distribution of radiopharmaceutical activity in the animal body, it is possible to convert it into a human model to obtain the internal dose received by 188Re-Mu-9 injection using the MIRD calculation method and the MCNP simulation code. According to the results of the study, the animal/human model can be acceptable method for dose estimation of antibody-based radiopharmaceuticals.


Subject(s)
Radiopharmaceuticals , Rhenium , Humans , Mice , Animals , Radiopharmaceuticals/therapeutic use , Radioisotopes , Rhenium/therapeutic use , Radiometry/methods
2.
Appl Radiat Isot ; 166: 109396, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32889376

ABSTRACT

Radiopharmaceuticals with therapeutic applications are designed to deliver high doses of radiation to target organs with minimizing unwanted radiation to healthy tissues. Owing to the potential of targeted radiotherapy to treat a wide range of malignancies, 170Tm -EDTMP was developed for possible therapeutic applications. This study describes absorbed dose prediction of 170Tm-EDTMP in human organs after animal injection which is determined via medical internal radiation dose (MIRD) and MCNP-4C code methods. It was estimated that a 1-MBq administration of 170Tm-EDTMP into the human body would result in an absorbed dose of 37.9 mGy (MIRD method) and 38.02 mGy (MCNP-4C code) in the bone surface after 60 days post injection. Highest and lowest difference between MIRD and MCNP results are for lung and bone surface respectively. Finally, the results show that there is a good agreement between MIRD method and MCNP-4C simulation code for absorbed dose estimation.


Subject(s)
Bone Neoplasms/radiotherapy , Organometallic Compounds/therapeutic use , Organophosphonates/therapeutic use , Pain/radiotherapy , Radiometry/methods , Animals , Bone Neoplasms/physiopathology , Bone Neoplasms/secondary , Computer Simulation , Humans , Mice , Models, Animal , Organometallic Compounds/administration & dosage , Organometallic Compounds/pharmacokinetics , Organophosphonates/administration & dosage , Organophosphonates/pharmacokinetics , Pain Management/methods , Palliative Care/methods , Radioisotopes/administration & dosage , Radioisotopes/pharmacokinetics , Radioisotopes/therapeutic use , Radiometry/statistics & numerical data , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/pharmacokinetics , Radiopharmaceuticals/therapeutic use , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Rats , Thulium/administration & dosage , Thulium/pharmacokinetics , Thulium/therapeutic use , Tissue Distribution
3.
J. venom. anim. toxins incl. trop. dis ; 16(4): 639-646, 2010. ilus, graf, tab
Article in English | LILACS, VETINDEX | ID: lil-566164

ABSTRACT

Iranian scorpions belong mainly to the Buthidae and Scorpionidae families, distributed into 16 genera and 25 species. In Iran, similar to other parts of the world, there are a few known species of scorpions responsible for severe envenoming; amongst which Mesobuthus eupeus is the most common. Its venom contains several toxin fractions that may affect the ion channel. In the present study purification, labeling and biological evaluation of M. eupeus venom are described. For separation, soluble venom was loaded on a chromatography column packed with Sephadex G-50 gel. Subsequently, the fractions were collected according to UV absorption at a wavelength of 280 nm. Toxic fraction (F3) was loaded on an anionic ion exchanger resin and then on a cationic resin. Finally, toxic subfractions F3.1.6 and F3.1.9 were labeled with 99mTc and injected into normal mice to distinguish excretion pathway. The venom toxic fraction was successfully obtained in its purified form. Radiolabeling of toxic fractions was performed at high specific activity with radiochemical purity of more than 97 and 95 percent respectively for F3.1.6 and F3.1.9. Biodistribution studies in normal mice with two toxic fractions usually show rapid clearance of the compounds from blood and tissue except for kidneys. Since tissue distribution studies are very important for clinical purpose, the present findings suggest that 99mTc labeling of venom is a useful tool for in vivo studies and comprises an excellent approach to monitoring the process of biodistribution and kinetics of toxins.(AU)


Subject(s)
Animals , Scorpion Venoms/isolation & purification , Biological Products , Chromatography , Scorpions