Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Asian Pac J Cancer Prev ; 17(3): 1197-9, 2016.
Article in English | MEDLINE | ID: mdl-27039748

ABSTRACT

BACKGROUND: This study aimed to facilitate decision-making in cases of breast cancer radiotherapy shifts by simulating millimetric shifts and analyzing their effects on dose distribution. METHODS: The study included 30 patients with left side breast cancer who were treated with three dimensional conformal radiotherapy (3D-CRT) in the Radiation Oncology Department in Hatay Public Hospital, between January 2013 and April 2015. A treatment plan shifting at three axes with six different measures was simulated. RESULTS: The biggest difference in values was (+3mm shift) 476cGy, with a 7.7 % change for heart and 25.6% for spinal cord. The shifts in values respectively for CTV min, mean, max were -4.8%, 2.5%, 4%. The differences for lymphatic min, mean, max were 21.3%, 20.3%, -12.2%. CONCLUSION: The most important thing is not the treatment plan quality, but its practicality. The treatment plan must be practical and its practice must be controlled rigidly.


Subject(s)
Breast Neoplasms/radiotherapy , Lymphatic Irradiation/methods , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Adult , Aged , Breast Neoplasms/pathology , Computer Simulation , Female , Follow-Up Studies , Humans , Middle Aged , Neoplasm Staging , Prognosis , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...