Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
Add more filters











Publication year range
1.
Appl Bionics Biomech ; 2021: 9922210, 2021.
Article in English | MEDLINE | ID: mdl-34484418

ABSTRACT

BACKGROUND: The World Health Organization has reported that 1.35 million people die on the roads every year due to road traffic accidents. This paper focuses on exploring a passive safety system that reduces lesions in the overtaking run-over scenario. METHODS: Head Injury Criterion (HIC) and Combined Thoracic Index (CTI) were evaluated through numerical simulations using LS-Dyna®; in order to compare the computed results, three different speed scenarios were carried out (velocity of running over 40, 50, 60 km/h). RESULTS: The computed results were divided into groups, A for the run-over test without a passive security system and B for the run-over test with a passive security system. For case A.1, the HIC15 was 3325. For case A.2, the HIC15 was 1510, and for case A.3, the HIC 15 was 1208. For case B.1, the HIC15 2605, for case B.2, the HIC15 was 1282, and for case B.3, the HIC was 730. CONCLUSION: The comparative results show that the passive safety system installed on the bicycle has an increased benefit impact on the severity of the injury on vulnerable road users, decreasing the probability of cranioencephalic lesions in all study cases. In addition, the thorax injuries are cut down only in the impact scenario at a speed of 40 km/h.

2.
Opt Express ; 26(2): 2033-2038, 2018 Jan 22.
Article in English | MEDLINE | ID: mdl-29401924

ABSTRACT

A highly sensitive technique for analyzing surface tension and dynamic viscosity of nanofluids was reported. Multiwall carbon nanotubes suspended in ethanol were evaluated. The assistance of a Fabry-Perot interferometer integrated by a small sample volume fluid allowed us to explore the stability and mechanical properties exhibited by the nanostructures. The surface tension and dynamic viscosity of the colloid was examined by using interferometric optical signals reflected from a remnant drop pending at the end of an optical fiber. Nanosecond pulses provided by a Nd:YAG laser source with 9.5 MW/mm2 at 532 nm wavelength were used to induce mechano-optical effects in the liquid drop. The mechanical parameters were approximated, taking into account single optical pulses interacting with an inelastic mass-spring-damper system.

3.
Obes Sci Pract ; 3(4): 434-445, 2017 12.
Article in English | MEDLINE | ID: mdl-29259802

ABSTRACT

Objective: The differential effect of GLP-1 agonist Exenatide on functional connectivity of the nucleus tractus solitaries (NTS), a key region associated with homeostasis, and on appetite-related behaviours was investigated in women with normal weight compared with women with obesity. Methods: Following an 8-h fast, 19 female subjects (11 lean, 8 obese) participated in a 2-d double blind crossover study. Subjects underwent functional magnetic resonance imaging at fast and 30-min post subcutaneous injection of 5 µg of Exenatide or placebo. Functional connectivity was examined with the NTS. Drug-induced functional connectivity changes within and between groups and correlations with appetite measures were examined in a region of interest approach focusing on the thalamus and hypothalamus. Results: Women with obesity reported less hunger after drug injection. Exenatide administration increased functional connectivity of the left NTS with the left thalamus and hypothalamus in the obese group only and increased the correlation between NTS functional connectivity and hunger scores in all subjects, but more so in the obese. Conclusions: Obesity can impact the effects of Exenatide on brain connectivity, specifically in the NTS and is linked to changes in appetite control. This has implications for the use of GLP-1 analogues in therapeutic interventions.

4.
Int J Obes (Lond) ; 41(8): 1185-1195, 2017 08.
Article in English | MEDLINE | ID: mdl-28360430

ABSTRACT

BACKGROUND/OBJECTIVES: The brain has a central role in regulating ingestive behavior in obesity. Analogous to addiction behaviors, an imbalance in the processing of rewarding and salient stimuli results in maladaptive eating behaviors that override homeostatic needs. We performed network analysis based on graph theory to examine the association between body mass index (BMI) and network measures of integrity, information flow and global communication (centrality) in reward, salience and sensorimotor regions and to identify sex-related differences in these parameters. SUBJECTS/METHODS: Structural and diffusion tensor imaging were obtained in a sample of 124 individuals (61 males and 63 females). Graph theory was applied to calculate anatomical network properties (centrality) for regions of the reward, salience and sensorimotor networks. General linear models with linear contrasts were performed to test for BMI and sex-related differences in measures of centrality, while controlling for age. RESULTS: In both males and females, individuals with high BMI (obese and overweight) had greater anatomical centrality (greater connectivity) of reward (putamen) and salience (anterior insula) network regions. Sex differences were observed both in individuals with normal and elevated BMI. In individuals with high BMI, females compared to males showed greater centrality in reward (amygdala, hippocampus and nucleus accumbens) and salience (anterior mid-cingulate cortex) regions, while males compared to females had greater centrality in reward (putamen) and sensorimotor (posterior insula) regions. CONCLUSIONS: In individuals with increased BMI, reward, salience and sensorimotor network regions are susceptible to topological restructuring in a sex-related manner. These findings highlight the influence of these regions on integrative processing of food-related stimuli and increased ingestive behavior in obesity, or in the influence of hedonic ingestion on brain topological restructuring. The observed sex differences emphasize the importance of considering sex differences in obesity pathophysiology.


Subject(s)
Body Mass Index , Brain/anatomy & histology , Brain/physiology , Neural Pathways/anatomy & histology , Neural Pathways/physiology , Sex Characteristics , Adult , Analysis of Variance , Brain Mapping/methods , Diffusion Magnetic Resonance Imaging , Feeding Behavior/physiology , Feeding Behavior/psychology , Female , Humans , Impulsive Behavior/physiology , Male , Middle Aged , Models, Neurological , Neuroimaging , Obesity/physiopathology , Obesity/psychology , Philosophy , Photic Stimulation , Reward , United States , Young Adult
5.
Neurogastroenterol Motil ; 20(4): 369-76, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18179613

ABSTRACT

Food ingestion increases fundic impedance (FI) and reduces antral slow wave rate (SWR). Our aim was to determine if such changes can be integrated into an algorithm for automatic eating detection (AED). When incorporated in implantable medical devices, AED can time treatment to food intake without need for patient input. Four dogs were implanted with fundic and antral electrodes, connected to an implantable recording device. Changes in FI and SWR induced by fixed meals of different weights were determined, and were used to build an AED algorithm. Its performance was then tested on the same animals given an ad libitum access to food. The effects of gastric balloon distension and nitroglycerin on SWR and FI were also tested. Fixed meals reduced SWR in a weight-dependent manner, R(2) = 0.936, P < 0.05 baseline compared to 50, 100, 200 and 400 g. Meals increased FI above baseline in a weight-dependent manner; R(2) = 0.994, P < 0.05 baseline compared to 200 and 400 g. During ad libitum intake, the AED algorithm detected 86% of all meals > or =15 g. Gastric distension reduced SWR and increased FI. Nitroglycerin reduced SWR. AED, using changes in FI and gastric SWR is feasible. Changes in FI and SWR are induced primarily by the presence of food in the stomach.


Subject(s)
Algorithms , Eating/physiology , Stomach/physiology , Animals , Dogs , Electrodes, Implanted
6.
Neurogastroenterol Motil ; 20(1): 63-8, 2008 Jan.
Article in English | MEDLINE | ID: mdl-17931337

ABSTRACT

Gastric motor function assessment, in humans and animals, is typically performed for short recording periods. The aim of this article was to monitor gastric electrical and motor activity in the antrum and fundus simultaneously, for long periods, using a new implantable system. Ten dogs were implanted with fundic and antral electrodes for assessment of impedance and electrical activity. Dogs were studied while in cages, for periods of 22-26 h. From late evening and until feeding on the next day, slow wave (SW) rhythm demonstrated a distinct pattern of intermittent pauses (mean duration = 22.8 +/-4.1 s) that delineated groups of SW's. Phasic increases in fundic tone were seen mostly in association with SW pauses, and were highly correlated with antral contractions, R(2) = 0.652, P < 0.05. The SW rate (events per minute) in the postprandial period, fasting and night time was 4.2 +/- 0.2, 5 +/- 0.2 and 4.7 +/- 0.3, respectively, P < 0.05 postprandial vs other periods. Antral and fundic mechanical activities were highly correlated during fasting, particularly at night. This novel method of prolonged gastric recording provides valuable data on the mechanical and electrical activity of the stomach, not feasible by current methods of recording. During fasting, fundic and antral motor activities are highly correlated and are associated with periodic pauses in electrical activity.


Subject(s)
Circadian Rhythm , Stomach/physiology , Animals , Biomechanical Phenomena , Dogs , Electric Impedance , Electrophysiology , Gastric Fundus/physiology , Pyloric Antrum/physiology
7.
Neurogastroenterol Motil ; 18(8): 647-53, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16918729

ABSTRACT

Neural gastrointestinal electrical stimulation (NGES) induces sequential contractions and enhances emptying in acute canine gastric and colonic models. This study was set to determine (i) the effect of NGES in a chronic canine model of delayed colonic transit and (ii) possible mechanism of action. Four pairs of electrodes were implanted in the distal colon of nine mongrel dogs. Delayed colonic transit was induced by diphenoxylate/atropine and alosetron. Transit was fluoroscopically determined by the rate of evacuation of radiopaque markers, and was tested twice in each dog, in random order, on and off stimulation. Two stimulation sequences, separated by 1 min, were delivered twice a day via exteriorized electrodes. Colonic manometry during stimulation was performed before and after intravenous (i.v.) injection of 1 mg of atropine. Complete evacuation of all markers was significantly shortened by NGES, from 4 days to 2 days, interquartile range 3-4 days vs 2-3 days, respectively, P = 0.016. NGES induced strong sequential contractions that were significantly diminished by atropine: 190.0 +/- 14.0 mmHg vs 48.7 +/- 19.4 mmHg, respectively (P < 0.001). NGES induces strong sequential colonic contractions and significantly accelerates movement of content in a canine model of delayed colonic transit. The effect is atropine sensitive.


Subject(s)
Colon/physiology , Electric Stimulation Therapy , Gastrointestinal Transit/physiology , Intestinal Diseases/therapy , Animals , Colon/innervation , Disease Models, Animal , Dogs , Electrodes, Implanted , Female , Gastrointestinal Agents/pharmacology , Intestinal Diseases/chemically induced , Manometry
8.
J Med Eng Technol ; 27(4): 164-77, 2003.
Article in English | MEDLINE | ID: mdl-12851061

ABSTRACT

In the recent years, functional electrical stimulation has been applied to restore impaired motility in the gastrointestinal tract. Unlike other methods of electrical stimulation of the gut, microprocessor-controlled, sequential electrical stimulation has been shown to induce peristalsis and enhance emptying in acute canine gastric and colonic models. This study aims at completing the development of a portable microprocessor-based functional stimulator system consisting of a microelectronic stimulator, patient-specific computer-based real-time software and a programming interfacing device. The ultimate goals of the design are to ensure that (1) the portable stimulator can be efficiently utilized in chronic animal experiments; and (2) the device can be further miniaturized into an implantable version. The designed portable stimulator generates four channel sequential bipolar rectangular pulse trains with programmable parameters within the stimulation requirements obtained from a previously developed computer model. Real-time simulation of colonic peristalsis and a case-specific stimulation model were implemented using patient-specific computer-based software. A chronic canine case study confirmed the feasibility of this microprocessor-controlled stimulation method for future clinical applications in humans.


Subject(s)
Algorithms , Electric Stimulation Therapy/instrumentation , Electric Stimulation Therapy/methods , Gastrointestinal Diseases/rehabilitation , Ambulatory Care/methods , Animals , Constipation/therapy , Dogs , Electrodes, Implanted , Equipment Design , Feasibility Studies , Miniaturization , Pilot Projects , Software Design , Treatment Outcome
9.
Gastroenterology ; 118(2): 258-63, 2000 Feb.
Article in English | MEDLINE | ID: mdl-10648453

ABSTRACT

BACKGROUND & AIMS: Gastric electrical stimulation has been attempted for years without much success. The aim of this study was to determine if movement of solid gastric content could be achieved using microprocessor-controlled sequential electrical stimulation. METHODS: The study was performed on 9 anesthetized dogs. The dogs underwent laparotomy, pyloroplasty, and implantation of 4-6 sets of bipolar stainless-steel wire electrodes. Each set consisted of 2-6 electrodes (10 x 0.25 mm, 3 cm apart) implanted circumferentially. The stomach was filled with solid food mixed with plastic pellets, and the process of gastric emptying was monitored. Artificial contractions were produced using microprocessor-controlled phase-locked bipolar trains of 50-Hz rectangular voltage with flexible amplitudes. RESULTS: Using the above stimulating parameters, we were able to produce circumferential gastric contractions that were artificially propagated distally by embedding and phase-locking the stimulating voltage. The number of expelled pellets after the stimulation sessions was significantly higher than the number of pellets emptied during the nonstimulation sessions (P < 0.01). CONCLUSIONS: Microprocessor-controlled electrical stimulation produced artificial peristalsis and markedly accelerated the movement of solid gastric content.


Subject(s)
Gastric Emptying/physiology , Gastrointestinal Motility/physiology , Neurons/physiology , Stomach/innervation , Animals , Dogs , Electric Stimulation/instrumentation , Electric Stimulation/methods , Muscle Contraction/physiology , Muscle, Smooth/physiology
10.
J Med Eng Technol ; 23(1): 5-9, 1999.
Article in English | MEDLINE | ID: mdl-10202696

ABSTRACT

Microprocessor-controlled multi-site functional gastric electrical stimulation using synchronized higher frequency (above 25 Hz) bipolar voltages has been suggested as a possible new avenue towards efficient artificial control of gastric motility. However, the effect of this sequential stimulation on gastric electrical activity is unknown. Because of the substantial strength of the invoked sequential contractions, using implanted electrodes to assess gastric electrical activity (GEA) in experimental animals is difficult, if not impossible. Electrogastrography (EGG), the non-invasively obtained recording of GEA, provides an excellent opportunity to study the changes associated with the multi-site functional stimulation. In this study, we investigated 4 unconscious dogs with 4 circumferential sets of subserosally-implanted stimulating electrodes and 4 force transducers attached close to each stimulating electrode set at operation. The abdominal cavity of each dog was closed after the electrode implantations and 3 standard neonatal electrocardiographic electrodes were attached overlying the abdominal projection of the gastric axis. Two-channel EGG recordings were obtained for 1/2 h before any electrical stimulation and during 1/2 h of intensive sequential stimulation. Significant changes were observed in the EGG pattern during stimulation. These changes were quantified and compared to the basal recordings. Our findings indicate that the interrelation between spectral changes in cutaneous EGG and mechanical activity of the stomach could be far more complex than previously speculated.


Subject(s)
Electric Stimulation Therapy , Stomach/physiology , Animals , Dogs , Electric Stimulation Therapy/instrumentation , Electrocardiography/instrumentation , Electrodes, Implanted , Electrophysiology , Female , Gastrointestinal Motility/physiology , Male , Microcomputers , Muscle Contraction/physiology , Muscle, Smooth/physiology , Peristalsis/physiology , Signal Processing, Computer-Assisted , Transducers
11.
Dig Dis Sci ; 44(3): 523-8, 1999 Mar.
Article in English | MEDLINE | ID: mdl-10080144

ABSTRACT

Gastric electrical uncoupling is the lack of electrical synchronization in different parts of the stomach. The aim of this study was to investigate the impact of gastric electrical uncoupling on the level of randomness of canine electrogastrograms (EGG). Electrogastrograms were obtained from 11 unconscious acute dogs. Gastric electrical uncoupling was produced surgically by performing two consecutive circumferential cuts through the entire thickness of the gastric muscle layer. Three separate 1/2-hr eight-channel bipolar EGGs were obtained from each dog in the basal state and after each cut. The signals were amplified using amplifiers with a flexible frequency range, digitized with 10-Hz sampling frequency, and 4.27-min portions of the digital EGGs were subjected to a turning point test for randomness. The number of turning points (NTPs) was determined from successive time intervals calculated from all EGG channels. Distributions of NTPs were calculated for each dog. An average NTPs (ANTP) for each dog in a given state (basal, after the first cut, and after the second cut) was calculated from the ANTPs of all channels. In six of 11 dogs the ANTP were greater after the first cut. The number rose to nine of 11 dogs after the second cut. In only 45% of the dogs were the ANTP distributions significantly different (P < 0.01) after the first cut (sensitivity 45%). After the second cut the sensitivity rose to 64%. In two specific EGG channels NTP distribution was significantly different (P < 0.01) in nine of 11 dogs (sensitivity: 82%) after the second cut. The dynamics of the level of randomness in EGG can be indicative of severe gastric electrical uncoupling. Some EGG channel configurations are more sensitive than others in recognizing gastric electrical uncoupling.


Subject(s)
Stomach/physiology , Animals , Dogs , Electric Conductivity , Electrodiagnosis , Electrophysiology , Gastric Emptying/physiology , Signal Processing, Computer-Assisted
12.
Gut ; 43(5): 607-11, 1998 Nov.
Article in English | MEDLINE | ID: mdl-9824339

ABSTRACT

BACKGROUND: Gastric electrical stimulation has been attempted for several years with little success. AIMS: To determine whether movement of liquid gastric content could be achieved using microprocessor controlled sequential electrical stimulation. METHODS: Eight anaesthetised dogs underwent laparotomy and implantation of four sets of bipolar stainless steel wire electrodes. Each set consisted of two to six electrodes (10x0.25 mm, 3 cm apart) implanted circumferentially. The stomach was filled with water and the process of gastric emptying was monitored. Artificial contractions were produced using microprocessor controlled phase locked bipolar four second trains of 50 Hz, 14 V (peak to peak) rectangular voltage. In four of the dogs four force transducers were implanted close to each circumferential electrode set. In one gastroparetic patient the effect of direct electrical stimulation was determined at laparotomy. RESULTS: Using the above stimulating parameters circumferential gastric contractions were produced which were artificially propagated distally by phase locking the stimulating voltage. Averaged stimulated gastric emptying times were significantly shorter than spontaneus emptying times (t1/2 6.7 (3.0) versus 25.3 (12.9) minutes, p<0.01). Gastric electrical stimulation of the gastroparetic patient at operation produced circumferential contractions. CONCLUSIONS: Microprocessor controlled electrical stimulation produced artificial peristalsis and notably accelerated the movement of liquid gastric content.


Subject(s)
Electric Stimulation/instrumentation , Gastric Emptying/physiology , Microcomputers , Animals , Dogs , Female , Male , Peristalsis/physiology , Water
13.
Can J Gastroenterol ; 12(6): 423-30, 1998 Sep.
Article in English | MEDLINE | ID: mdl-9784898

ABSTRACT

Electrogastrography (EGG) is the recording of gastric electrical activity (GEA) from the body surface. The cutaneous signal is low in amplitude and consequently must be amplified considerably. The resultant signal is heavily contaminated with noise, and visual analysis alone of an EGG signal is inadequate. Consequently, EGG recordings require special methodology for acquisition, processing and analysis. Essential components of this methodology involve an adequate system of digital filtering, amplification and analysis, along with minimization of the sources of external noise (random motions of the patient, electrode-skin interface impedance, electrode bending, obesity, etc) and a quantitative interpretation of the recordings. There is a close relationship between GEA and gastric motility. Although it has been demonstrated that EGG satisfactorily reflects internal GEA frequency, there is not acceptable correlation with gastric contractions or gastric emptying. Many attempts have been made to relate EGG 'abnormalities' with clinical syndromes and diseases; however, the diagnostic and clinical value of EGG is still very much in question.


Subject(s)
Electrodiagnosis , Gastrointestinal Motility , Stomach/physiology , Artifacts , Gastric Emptying , Humans , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL