Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Clin Diagn Lab Immunol ; 8(5): 1018-20, 2001 Sep.
Article in English | MEDLINE | ID: mdl-11527821

ABSTRACT

The existence of human immunodeficiency virus type 1 (HIV-1) subtypes has many important implications for the global evolution of HIV and for the evaluation of pathogenicity, transmissibility, and candidate HIV vaccines. The aim of this study was to establish a rapid method for determination of HIV-1 subtypes useful for a routine diagnostic laboratory and to investigate the distribution of HIV-1 subtypes in Austrian patients. Samples were tested by a subtyping method based on a 1.3-kb sequence of the polymerase gene generated by a commercially available drug resistance assay. The generated sequence was subtyped by means of an HIV sequence database. Results of 74 routine samples revealed subtype B (71.6%) as the predominant subtype, followed by subtype A (13.5%) and subtype C (6.8%). Subtypes E, F, G, and AE (CM240) were also detected. This subtyping method was found to be very easy to handle, rapid, and inexpensive and has proved suitable for high-throughput routine diagnostic laboratories. The specific polymerase gene sequence, however, must be existent.


Subject(s)
HIV Infections/virology , HIV-1/classification , Reagent Kits, Diagnostic/virology , Serotyping/methods , Child , DNA Polymerase beta/genetics , Female , HIV Infections/enzymology , HIV Reverse Transcriptase/genetics , HIV-1/genetics , Humans , Male , RNA Polymerase II/genetics
3.
J Clin Microbiol ; 39(5): 1788-90, 2001 May.
Article in English | MEDLINE | ID: mdl-11325991

ABSTRACT

In this study, we compared serum hepatitis C virus (HCV) RNA concentrations with HCV RNA concentrations in whole blood collection tubes, including two different types of EDTA tubes and nucleic acid stabilization tubes (NASTs). We also investigated the impact of a processing delay on HCV RNA concentration in these tubes. In NASTs, the mean HCV RNA concentration was comparable to the mean serum HCV RNA concentration at "date zero." In EDTA tubes, mean baseline HCV RNA concentrations were higher. Storage at room temperature up to 96 h did not result in a decline of HCV RNA concentration in any of the whole blood collection tubes. In NASTs, HCV RNA concentrations remained stable during the whole study period, whereas a significant increase of HCV RNA was observed in both types of EDTA tubes at 96 h compared to date zero. We concluded that HCV RNA remains stable in NASTs at room temperature for at least 96 h, allowing greater flexibility in sample collection and transport.


Subject(s)
Blood Specimen Collection , Blood/virology , Hepacivirus/isolation & purification , Hepatitis C/virology , RNA, Viral/blood , Adult , Blood Specimen Collection/instrumentation , Blood Specimen Collection/methods , Female , Humans , Male , Middle Aged
4.
J Clin Virol ; 20(1-2): 49-57, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11163583

ABSTRACT

BACKGROUND: Cytomegalovirus (CMV) infections are a major threat in transplant recipients. In recent years, new assays for routine CMV diagnosis, based on molecular techniques, have become available. OBJECTIVE: The impact of molecular assays for CMV diagnosis in transplant recipient was evaluated. STUDY DESIGN: A total of 51 transplant recipients were screened for CMV infection. Serological (AxSYM CMV IgG and recombinant CMV IgM assays), antigenemia, CMV DNA (qualitative in house PCR and the quantitative COBAS AMPLICOR CMV MONITOR Test), and CMV mRNA (NucliSens CMV pp67 Test) tests were compared. RESULTS: In 11/20 bone marrow transplant (BMT) recipients and 10/31 renal transplant (RTX) recipients there was no evidence of active CMV infection. Ten RTX recipients and one BMT recipient were antigenemia positive, 21 RTX and seven BMT recipients were PCR positive (qualitative CMV PCR). There were more BMT recipients CMV DNA positive in serum (7/21) than antigenemia positive (1/21). CMV mRNA was found positive in two BMT recipients (one case with no other evidence of CMV infection, the other one CMV DNA positive and antigenemia negative). The only antigenemia positive BMT recipient was found negative for CMV mRNA, but positive in all other tests. Eight RTX recipients were found positive for CMV mRNA. Six of them were also antigenemia positive and five of those were also found positive for CMV IgM. One CMV mRNA positive RTX recipient was CMV IgM positive but antigenemia negative and the other one CMV mRNA positive RTX recipient was found negative in all other tests. Two antigenemia positive RTX recipients were found negative for mRNA and CMV IgM. CONCLUSION: Antigenemia was found to be a good screening test for CMV infection in RTX recipients. In BMT recipients, tests based on molecular techniques appeared to be superior compared to antigenemia.


Subject(s)
Bone Marrow Transplantation , Cytomegalovirus Infections/diagnosis , Cytomegalovirus/genetics , Kidney Transplantation , Adolescent , Adult , Aged , Antigens, Viral/blood , Child , Child, Preschool , Cytomegalovirus Infections/virology , DNA, Viral/blood , Evaluation Studies as Topic , Female , Humans , Male , Middle Aged , Polymerase Chain Reaction , RNA, Messenger/analysis , RNA, Viral/blood , Serologic Tests
5.
Clin Diagn Lab Immunol ; 7(5): 853-5, 2000 Sep.
Article in English | MEDLINE | ID: mdl-10973470

ABSTRACT

The Cobas Amplicor HBV Monitor test for quantitative determination of hepatitis B virus (HBV) DNA in serum has recently been introduced. To evaluate the performance of this assay in a routine diagnostic laboratory, reproducibility of results was determined with the First European Union Concerted Action HBV Proficiency Panel and the Accurun 325 HBV DNA Positive Control, Series 300. Results for 270 routine serum samples were additionally evaluated. To avoid the retesting of a large number of samples due to titers exceeding the upper limit for the linear range of the assay, sera of patients with chronic hepatitis B (CHB) were diluted prior to the assay to 10(-4) in normal human plasma, which is included in the assay. The mean coefficient of variation was 22.9% for all input HBV DNAs. Of 270 routine serum samples, 182 (150 sera from transplant donors and 32 sera from patients who had recovered from CHB) tested negative. Eighty-six sera were found to be HBV DNA positive; in six sera, HBV DNA levels were found to exceed the upper limit for the linear range of the assay and had to be retested. In the remaining two sera, inhibition occurred. The semiautomated Cobas Amplicor HBV Monitor test showed sufficient reproducibility and helped in avoiding human error. The relatively narrow linear range of detection is a limitation of the new assay.


Subject(s)
DNA, Viral/blood , Hepatitis B, Chronic/virology , Polymerase Chain Reaction/methods , Reagent Kits, Diagnostic , Automation , Diagnostic Tests, Routine , Hepatitis B virus/genetics , Hepatitis B, Chronic/blood , Hepatitis B, Chronic/diagnosis , Humans , Laboratories , Reproducibility of Results
6.
Clin Diagn Lab Immunol ; 7(2): 298-300, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10702509

ABSTRACT

The level of hepatitis B virus (HBV) DNA in serum reflects the replicative activity of HBV. To compare serum HBV DNA levels in different states of hepatitis B, 47 sera of patients with HBeAg-positive chronic hepatitis B, 4 sera of patients with HBeAg-negative chronic hepatitis B, 40 samples of patients after HBeAg seroconversion during alpha interferon treatment, 57 sera of inactive HBsAg carriers, and 42 sera of patients who had recovered from chronic hepatitis B more than 12 months prior to blood collection were checked for the presence of HBV DNA with the Amplicor HBV Monitor Test. In patients with HBeAg-positive chronic hepatitis B, the median of serum HBV DNA levels (8.3 x 10(8) copies/ml) was significantly higher than that for patients after HBeAg seroconversion (6.2 x 10(3) copies/ml) and than that for inactive HBsAg carriers (5.6 x 10(3) copies/ml). None of the patients who had recovered from hepatitis B had detectable HBV DNA in serum. Quantitative PCR proved to be a valuable tool for identification of different states of HBV infection. This technique was found to be a good method for determination of serum HBV DNA levels both for patients with HBeAg seroconversion and for inactive carriers who showed low viremia not detectable by conventional hybridization assays.


Subject(s)
DNA, Viral/blood , Hepatitis B virus/genetics , Hepatitis B, Chronic/virology , Polymerase Chain Reaction , Adolescent , Adult , Aged , Child , Female , Hepatitis B virus/isolation & purification , Hepatitis B, Chronic/blood , Hepatitis B, Chronic/physiopathology , Humans , Male , Middle Aged , Polymerase Chain Reaction/methods , Viral Load
7.
Clin Chem Lab Med ; 36(8): 583-6, 1998 Aug.
Article in English | MEDLINE | ID: mdl-9806464

ABSTRACT

Polymerase chain reaction-based molecular assays are gaining increasing importance in the diagnosis and monitoring of infectious diseases. Over the past several years, the development and application of these techniques has initiated a revolution in the diagnosis and monitoring of hepatitis C infection. Presently, molecular assays are exclusively done in especially dedicated laboratories. Advances in automation will bring these technologies into routine diagnostic laboratories and will make them widely used.


Subject(s)
Hepacivirus/isolation & purification , RNA, Viral/blood , Reverse Transcriptase Polymerase Chain Reaction/methods , Automation , Hepacivirus/genetics , Humans
8.
Clin Chem Lab Med ; 36(8): 601-4, 1998 Aug.
Article in English | MEDLINE | ID: mdl-9806469

ABSTRACT

The Amplicor HBV Monitor Test for quantitative detection of serum hepatitis B virus (HBV) DNA has recently been introduced. This assay is based on PCR and a non-radioactive hybridization and detection system on microwell plates. Evaluation in a routine diagnostic laboratory showed excellent sensitivity and adequate reproducibility; however, a more automated format would be desirable. The Amplicor HBV Monitor Test is useful for recognizing those patients who might benefit from antiviral treatment and for evaluation of the efficacy of anti-hepatitis B virus treatment.


Subject(s)
DNA, Viral/blood , Hepatitis B virus/isolation & purification , Polymerase Chain Reaction/methods , Hepatitis B virus/genetics , Humans , Reproducibility of Results , Sensitivity and Specificity
9.
J Hum Virol ; 1(5): 314-9, 1998.
Article in English | MEDLINE | ID: mdl-10195258

ABSTRACT

OBJECTIVE: To define the usefulness of molecular parameters in patients with chronic hepatitis C who are undergoing antiviral therapy. Anti-hepatitis C virus (HCV) treatment was monitored by determination of serum HCV load and by presence of HCV RNA in peripheral blood mononuclear cells (PBMCs). STUDY DESIGN/METHODS: Fifty-one patients with chronic hepatitis C undergoing antiviral therapy with interferon-alpha plus ribavirin were studied. Serum HCV RNA load was tested with a quantitative assay (Amplicor HCV Monitor Test) before, during, and up to 12 months after end of treatment. If HCV RNA was not detectable, serum samples were subsequently tested with a qualitative assay (Cobas Amplicor HCV Test) and corresponding ethylenediaminetetraacetic acid (EDTA)-treated blood was checked for presence of HCV RNA in peripheral blood mononuclear cells (PBMCs). Sustained virologic response was defined by loss of HCV RNA 12 months after the end of treatment. RESULTS: Four patients (7.8%) were found to be sustained virologic responders, 17 (33.3%) were transient virologic responders, and 30 (58.8%) were virologic nonresponders. No significant difference was found in the median pretreatment serum HCV RNA load between sustained virologic responders, transient virologic responders, and virologic nonresponders. At 1 month after start of therapy, HCV RNA was not detectable with both the serum and the PBMC assay in 12 (23.5%) of 51 patients. Four remained HCV RNA-negative until 12 months after the end of treatment. In 14 of 17 transient virologic responders, reappearance of HCV RNA was detected earlier in PBMCs than in serum. CONCLUSIONS: Based on these results in 51 patients, quantitation of baseline serum HCV RNA does not appear to be a decisive factor to the management of the individual patient. Early assessment of serum HCV RNA level after start of anti-viral treatment seems to be of major importance to identify virologic nonresponders. Reappearance of HCV RNA may be demonstrated earlier in PBMCs than in serum.


Subject(s)
Hepacivirus/genetics , Hepatitis C, Chronic/virology , RNA, Viral/blood , Viremia/diagnosis , Adult , Aged , Antiviral Agents/therapeutic use , Hepatitis C, Chronic/drug therapy , Humans , Interferon-alpha/therapeutic use , Leukocytes, Mononuclear/virology , Middle Aged , Polymerase Chain Reaction/methods , Ribavirin/therapeutic use , Time Factors , Viral Load
10.
J Clin Microbiol ; 35(6): 1592-4, 1997 Jun.
Article in English | MEDLINE | ID: mdl-9163490

ABSTRACT

A new molecular assay, based on a rapid DNA extraction protocol, PCR, and hybridization to a specific probe in a nonradioactive microwell plate format was used to detect Mycoplasma pneumoniae in bronchoalveolar fluid specimens. The sensitivity of the assay was determined to be 10 to 100 organisms with M. pneumoniae reference strains. Specificity testing with different bacteria capable of producing pneumonia showed no cross-reactivity. In a prospective study, bronchoalveolar lavage fluids obtained from patients with pneumonia were investigated with the PCR assay and compared to culture. Twelve positive samples were detected with the PCR assay. Seven of them were subsequently confirmed by culture. All patients with positive PCR results seroconverted. Application of the PCR assay described may lead to safe and early diagnosis of M. pneumoniae in patients with pneumonia.


Subject(s)
Molecular Probe Techniques , Mycoplasma pneumoniae/isolation & purification , Pneumonia, Mycoplasma/diagnosis , Polymerase Chain Reaction/methods , Adolescent , Adult , Aged , Aged, 80 and over , Antibodies, Bacterial/blood , Bronchoalveolar Lavage Fluid/microbiology , Child , Child, Preschool , DNA, Bacterial/analysis , Enzyme-Linked Immunosorbent Assay/methods , Female , Humans , Infant , Male , Middle Aged , Molecular Sequence Data , Mycoplasma pneumoniae/immunology , Nucleic Acid Hybridization , Prospective Studies , Sensitivity and Specificity
11.
Clin Diagn Virol ; 7(3): 139-45, 1997 Feb.
Article in English | MEDLINE | ID: mdl-9126682

ABSTRACT

BACKGROUND: The COBAS AMPLICOR (CA) instrument for the amplification and detection steps of the AMPLICOR molecular diagnostic assays has recently been introduced. The system contains a single thermal cycler with two independently controlled heating/cooling blocks, a pipettor, a magnetic particle washer, a photometer and an incubator. OBJECTIVE: The performance of the CA instrument was evaluated in a routine diagnostic laboratory for the detection of hepatitis C virus (HCV) RNA. The new system was compared with the corresponding microwell plate assay (AMPLICOR HCV Test). STUDY DESIGN: Routine clinical sera (350) from hemodialysis patients and patients with chronic HCV infection and interferon therapy were studied. If discrepant results were obtained, both assays were repeated (specimen preparation, amplification and detection); in addition, the HCV copy number was determined with the AMPLICOR HCV MONITOR Test. RESULTS: There was a correlation between the CA HCV Test and the AMPLICOR HCV Test in 341 of 350 specimens (97%). After resolution of 9 discrepant results, the CA HCV Test gave a sensitivity of 97.8% and a specificity of 99.4%. The most common reason for discrepant results was a low HCV RNA copy number. CONCLUSION: The CA system was found to be a labor-saving, fast and reliable instrument for the amplification and detection steps of a RT-PCR molecular assay for detection of HCV RNA.


Subject(s)
Hepacivirus/chemistry , Hepacivirus/genetics , Polymerase Chain Reaction/instrumentation , RNA, Viral/blood , Flaviviridae Infections/diagnosis , Flaviviridae Infections/genetics , Humans , RNA, Viral/genetics , Sensitivity and Specificity
12.
Clin Diagn Virol ; 5(1): 73-8, 1996 Feb.
Article in English | MEDLINE | ID: mdl-15566864

ABSTRACT

BACKGROUND: Hepatitis C virus (HCV) infection is highly prevalent in hemodialysis and AIDS patients. Little information exists about the viral load in those patients. OBJECTIVE: To characterize HCV infection in hemodialysis and AIDS patients, the viral load in the sera was measured. Results were compared with genotypes, gender of the patients, and biochemical markers of active hepatitis. STUDY DESIGN: Sera from a total of 442 patients were screened with a third-generation EIA, and anti-HCV immunoreactivity was confirmed with the Wellcozyme HCV Western Blot. After qualitative PCR with the Amplicor PCR Test, positives were genotyped using a reverse hybridization test. Determination of HCV levels was done with the Amplicor HCV Monitor assay. RESULTS: HCV RNA was detected in the sera of 95 (74.8%) EIA-positive patients. HCV RNA levels ranged from 1 x 10(4) to 1.4 x 10(6) molecules of HCV RNA/ml. Median HCV RNA levels of AIDS patients were slightly higher than those of hemodialysis patients. Male patients had higher median HCV RNA levels compared with female patients. No association between HCV RNA levels and both alanine aminotransferase (ALT) and aspartate aminotransferase (AST) levels was found. The most common genotypes were type 1b and type 1a, followed by type 3, type 4, and type 2a. There were no significant differences in HCV RNA levels among patients with genotypes 1a, 1b, and 2a. Patients infected with types 3 and 4, respectively, had significantly lower HCV RNA levels compared with other genotypes. CONCLUSION: Because the Amplicor HCV Monitor assay allows quantitation of low-titer viremic patients, HCV RNA levels were distinctly lower compared with previous reports. HCV RNA levels of males did not differ significantly from those of females. ALT and AST are very poor indicators of ongoing HCV infection. Patients with chronic type 3 or type 4 HCV infection tended to have lower HCV RNA levels.

SELECTION OF CITATIONS
SEARCH DETAIL
...