Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Front Med (Lausanne) ; 10: 1248894, 2023.
Article in English | MEDLINE | ID: mdl-37780565

ABSTRACT

Background: Squamous cell carcinoma (SCC) arising in a sacrococcygeal pilonidal sinus is rare, with cases of metastatic disease being even rarer. Among published cases, almost none have reported on systemic treatment. Objective: This disease has a poorer prognosis than other forms of cutaneous SCC; therefore, our objective is to shed some light on the treatment of metastatic disease. Methods: We present a series of nine cases treated at a single center, four of whom received systemic treatment. Additionally, other previously reported cases of metastatic disease are included in an attempt to draw stronger conclusions. Results: Four patients were treated under several treatment regimens, with a median progression-free survival of only 2 months and two instances of partial response (18%). The best result was achieved with cemiplimab. Across all the cases, there was a trend toward a benefit of the use of systemic treatment (HR 0.41, 95% CI 0.15-1.12, p = 0.083; median overall survival 13 vs. 8 months). Limitations: Limitations include the significant lack of information on previously published cases and the extremely heterogeneous nature of the existing information. Conclusion: The initial systemic treatment should be an anti-PD-1, as with other SCCs. After progression on anti-PD-1, there is no strong evidence to support the recommendation of a specific treatment or sequence: options include cetuximab and/or chemotherapy (platinum, paclitaxel, 5-fluorouracyl).

2.
Nanomaterials (Basel) ; 12(12)2022 Jun 07.
Article in English | MEDLINE | ID: mdl-35745294

ABSTRACT

A novel method to extract the seven parameters of the double-diode model of solar cells using the current-voltage (I-V) characteristics under illumination and in the dark is presented. The algorithm consists of two subroutines which are alternatively run to adjust all the parameters of the cell in an iterative process. Curve fitting of the light I-V characteristics ensures accuracy in the prediction of the maximum power point, whereas simultaneously fitting the dark I-V characteristics results in a set of physically meaningful parameters that provide information about the physical performance of the photovoltaic devices. Experimental I-V curves of in-house solar cells are used to validate the proposed parameter extraction method, which can be furthermore applied to other types of p-n junction-based photovoltaic devices.

3.
Sensors (Basel) ; 19(8)2019 Apr 16.
Article in English | MEDLINE | ID: mdl-30995743

ABSTRACT

For current microelectronic integrated systems, the design methodology involves different steps that end up in the full system simulation by means of electrical and physical models prior to its manufacture. However, the higher the circuit complexity, the more time is required to complete these simulations, jeopardizing the convergence of the numerical methods and, hence, meaning that the reliability of the results are not guaranteed. This paper shows the use of a high-level tool based on Matlab to simulate the operation of an artificial neural network implemented in a mixed analog-digital CMOS process, intended for sensor calibration purposes. The proposed standard tool enables modification of the neural model architecture to adapt its characteristics to those of the electronic system, resulting in accurate behavioral models that predict the complete microelectronic IC system behavior under different operation conditions before its physical implementation with a simple, time-efficient, and reliable solution.

4.
Sensors (Basel) ; 19(1)2018 Dec 20.
Article in English | MEDLINE | ID: mdl-30577468

ABSTRACT

This paper presents a novel structure of Resistance- to-Period (R-T) Converter highly robust to supply and temperature variations. Robustness is achieved by using the ratiometric approach so that complex circuits or high accuracy voltage references are not necessary. To prove the proposed architecture of R-T converter, a prototype was implemented in a 0.18 µ m CMOS process with a single supply voltage of 1.8 V and without any stable reference voltage. Experimental results show a maximum ±1.5% output signal variation for ±10% supply voltage variation and in a 3⁻95 ° C temperature range.

5.
Sensors (Basel) ; 14(9): 15880-99, 2014 Aug 27.
Article in English | MEDLINE | ID: mdl-25166501

ABSTRACT

This paper presents a new micropower analog lock-in amplifier (LIA) suitable for battery-operated applications thanks to its reduced size and power consumption as well as its operation with single-supply voltage. The proposed LIA was designed in a 0.18 µm CMOS process with a single supply voltage of 1.8 V. Experimental results show a variable DC gain ranging from 24.7 to 42 dB, power consumption of 417 µW and integration area of 0.013 mm2. The LIA performance was demonstrated by measuring carbon monoxide concentrations as low as 1 ppm in dry N2. The experimental results show that the response to CO of the sensing system can be considerably improved by means of the proposed LIA.


Subject(s)
Amplifiers, Electronic , Carbon Dioxide/analysis , Conductometry/instrumentation , Electric Power Supplies , Gases/analysis , Energy Transfer , Equipment Design , Equipment Failure Analysis , Systems Integration
SELECTION OF CITATIONS
SEARCH DETAIL
...