Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Heart Assoc ; 10(13): e020597, 2021 07 06.
Article in English | MEDLINE | ID: mdl-34151580

ABSTRACT

Background Functional assessment of myocardial bridging (MB) remains clinically challenging because of the dynamic nature of the extravascular coronary compression with a certain degree of intraluminal coronary reduction. The aim of our study was to assess performance and diagnostic value of diastolic-fractional flow reserve (d-FFR) during dobutamine provocation versus conventional-FFR during adenosine provocation with exercise-induced myocardial ischemia as reference. Methods and Results This prospective study includes 60 symptomatic patients (45 men, mean age 57±9 years) with MB on the left anterior descending artery and systolic compression ≥50% diameter stenosis. Patients were evaluated by exercise stress-echocardiography test, and both conventional-FFR and d-FFR in the distal segment of left anterior descending artery during intravenous infusion of adenosine (140 µg/kg per minute) and dobutamine (10-50 µg/kg per minute), separately. Exercise-stress-echocardiography test was positive for myocardial ischemia in 19/60 patients (32%). Conventional-FFR during adenosine and peak dobutamine had similar values (0.84±0.04 versus 0.84±0.06, P=0.852), but d-FFR during peak dobutamine was significantly lower than d-FFR during adenosine (0.76±0.08 versus 0.79±0.08, P=0.018). Diastolic-FFR during peak dobutamine was significantly lower in the exercise-stress-echocardiography test -positive group compared with the exercise- stress-echocardiography test -negative group (0.70±0.07 versus 0.79±0.06, P<0.001), but not during adenosine (0.79±0.07 versus 0.78±0.09, P=0.613). Among physiological indices, d-FFR during peak dobutamine was the only independent predictor of functionally significant MB (odds ratio, 0.870; 95% CI, 0.767-0.986, P=0.03). Receiver-operating characteristics curve analysis identifies the optimal d-FFR during peak dobutamine cut-off ≤0.76 (area under curve, 0.927; 95% CI, 0.833-1.000; P<0.001) with a sensitivity, specificity, and positive and negative predictive value of 95%, 95%, 90%, and 98%, respectively, for identifying MB associated with stress-induced ischemia. Conclusions Diastolic-FFR, but not conventional-FFR, during inotropic stimulation with high-dose dobutamine, in comparison to vasodilatation with adenosine, provides more reliable functional significance of MB in relation to stress-induced myocardial ischemia.


Subject(s)
Adenosine/administration & dosage , Cardiotonic Agents/administration & dosage , Echocardiography, Stress , Fractional Flow Reserve, Myocardial , Myocardial Bridging/diagnostic imaging , Myocardial Ischemia/diagnostic imaging , Vasodilator Agents/administration & dosage , Adult , Aged , Diastole , Dobutamine/administration & dosage , Exercise Test , Feasibility Studies , Female , Humans , Male , Middle Aged , Myocardial Bridging/complications , Myocardial Bridging/physiopathology , Myocardial Ischemia/etiology , Myocardial Ischemia/physiopathology , Predictive Value of Tests , Prospective Studies , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...