Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Physiol (1985) ; 131(3): 1080-1087, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34323592

ABSTRACT

Cephalad fluid shifts in space have been hypothesized to cause the spaceflight-associated neuro-ocular syndrome (SANS) by increasing the intracranial-ocular translaminal pressure gradient. Lower body negative pressure (LBNP) can be used to shift upper-body blood and other fluids toward the legs during spaceflight. We hypothesized that microgravity would increase jugular vein volume (JVvol), portal vein cross-sectional area (PV), and intracranial venous blood velocity (MCV) and that LBNP application would return these variables toward preflight levels. Data were collected from 14 subjects (11 males) before and during long-duration International Space Station (ISS) spaceflights. Ultrasound measures of JVvol, PV, and MCV were acquired while seated and supine before flight and early during spaceflight at day 45 (FD45) and late at day 150 (FD150) with and without LBNP. JVvol increased from preflight supine and seated postures (46 ± 48% and 646 ± 595% on FD45 and 43 ± 43% and 702 ± 631% on FD150, P < 0.05), MCV increased from preflight supine (44 ± 31% on FD45 and 115 ± 116% on FD150, P < 0.05), and PV increased from preflight supine and seated (51 ± 56% on FD45 and 100 ± 74% on FD150, P < 0.05). Inflight LBNP of -25 mmHg restored JVvol and MCV to preflight supine level and PV to preflight seated level. Elevated JVvol confirms the sustained neck-head blood engorgement inflight, whereas increased PV area supports the fluid shift at the splanchnic level. Also, MCV increased potentially due to reduced lumen diameter. LBNP, returning variables to preflight levels, may be an effective countermeasure.NEW & NOTEWORTHY Microgravity-induced fluid shifts markedly enlarge jugular and portal veins and increase cerebral vein velocity. These findings demonstrate a marked flow engorgement at neck and splanchnic levels and may suggest compression of the cerebral veins by the brain tissue in space. LBNP (-25 mmHg for 30 min) returns these changes to preflight levels and, thus, reduces the associated flow and tissue disturbances.


Subject(s)
Cerebral Veins , Space Flight , Weightlessness , Humans , Lower Body Negative Pressure , Male , Portal Vein
2.
Ultrasound Med Biol ; 35(7): 1059-67, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19427106

ABSTRACT

An operationally available diagnostic imaging capability augments spaceflight medical support by facilitating the diagnosis, monitoring and treatment of medical or surgical conditions, by improving medical outcomes and, thereby, by lowering medical mission impacts and the probability of crew evacuation due to medical causes. Microgravity-related physiological changes occurring during spaceflight can affect the genitourinary system and potentially cause conditions such as urinary retention or nephrolithiasis for which ultrasonography (U/S) would be a useful diagnostic tool. This study describes the first genitourinary ultrasound examination conducted in space, and evaluates image quality, frame rate, resolution requirements, real-time remote guidance of nonphysician crew medical officers and evaluation of on-orbit tools that can augment image acquisition. A nonphysician crew medical officer (CMO) astronaut, with minimal training in U/S, performed a self-examination of the genitourinary system onboard the International Space Station, using a Philips/ATL Model HDI-5000 ultrasound imaging unit located in the International Space Station Human Research Facility. The CMO was remotely guided by voice commands from experienced, earth-based sonographers stationed in Mission Control Center in Houston. The crewmember, with guidance, was able to acquire all of the target images. Real-time and still U/S images received at Mission Control Center in Houston were of sufficient quality for the images to be diagnostic for multiple potential genitourinary applications. Microgravity-based ultrasound imaging can provide diagnostic quality images of the retroperitoneum and pelvis, offering improved diagnosis and treatment for onboard medical contingencies. Successful completion of complex sonographic examinations can be obtained even with minimally trained nonphysician ultrasound operators, with the assistance of ground-based real-time guidance.


Subject(s)
Pelvis/diagnostic imaging , Retroperitoneal Space/diagnostic imaging , Space Flight , Weightlessness , Allied Health Personnel/education , Astronauts , Feasibility Studies , Humans , Image Interpretation, Computer-Assisted/methods , Radiology/education , Remote Consultation/methods , Ultrasonography , Video Recording/methods
3.
Aviat Space Environ Med ; 73(9): 925-30, 2002 Sep.
Article in English | MEDLINE | ID: mdl-12234046

ABSTRACT

BACKGROUND: As a medical emergency that can affect even well-screened, healthy individuals, peritonitis developing during a long-duration space exploration mission may dictate deviation from traditional clinical practice due to the absence of otherwise indicated surgical capabilities. Medical management can treat many intra-abdominal processes, but treatment failures are inevitable. In these circumstances, percutaneous aspiration under sonographic guidance could provide a "rescue" strategy. HYPOTHESIS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid can be performed in microgravity. METHODS: Investigations were conducted in the microgravity environment of NASA's KC-135 research aircraft (0 G). The subjects were anesthetized female Yorkshire pigs weighing 50 kg. The procedures were rehearsed in a terrestrial animal lab (1 G). Colored saline (500 mL) was introduced through an intra-peritoneal catheter during flight. A high-definition ultrasound system (HDI-5000, ATL, Bothell, WA) was used to guide a 16-gauge needle into the peritoneal cavity to aspirate fluid. RESULTS: Intra-peritoneal fluid collections were easily identified, distinct from surrounding viscera, and on occasion became more obvious during weightless conditions. Subjectively, with adequate restraint of the subject and operators, the procedure was no more demanding than during the 1-G rehearsals. CONCLUSIONS: Sonographically guided percutaneous aspiration of intra-peritoneal fluid collections is feasible in weightlessness. Treatment of intra-abdominal inflammatory conditions in spaceflight might rely on pharmacological options, backed by sonographically guided percutaneous aspiration for the "rescue" of treatment failures. While this risk mitigation strategy cannot guarantee success, it may be the most practical option given severe resource limitations.


Subject(s)
Drainage , Peritonitis/surgery , Space Flight , Animals , Feasibility Studies , Female , Swine , Ultrasonography , Weightlessness , Weightlessness Simulation
4.
Am Surg ; 67(3): 232-5; discussion 235-6, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11270880

ABSTRACT

Pneumothorax is commonly seen in trauma patients; the diagnosis is confirmed by radiography. The use of ultrasound where radiographic capabilities are absent, is being investigated by the National Aeronautics and Space Administration. We investigated the ability of ultrasound to assess the magnitude of pneumothorax in a porcine model. Sonography was performed on anesthetized pigs in both ground-based laboratory (n = 5) and microgravity conditions (0 x g) aboard the KC-135 aircraft during parabolic flight (n = 4). Aliquots of air (50-100 cm3) were introduced into the chest to simulate pneumothorax. Results were videorecorded and digitized for later interpretation. Several distinct sonographic patterns of partial lung sliding were noted including the combination of a sliding zone with a still zone and a "segmented" sliding zone. These "partial lung sliding" patterns exclude massive pneumothorax manifested by a complete separation of the lung from the parietal pleura. In 0 x g, the sonographic picture is more diverse; one x g differences between posterior and anterior aspects are diminished. Modest pneumothorax can be inferred by the ultrasound sign of "partial lung sliding." This finding, which increases the negative predictive value of thoracic ultrasound, may be attributed to intermittent pleural contact, small air spaces, or alterations in pleural lubricant. Further studies of these phenomena are warranted.


Subject(s)
Disease Models, Animal , Pneumothorax/classification , Pneumothorax/diagnostic imaging , Severity of Illness Index , Weightlessness , Animals , Artifacts , Female , Pneumothorax/pathology , Pneumothorax, Artificial/instrumentation , Pneumothorax, Artificial/methods , Predictive Value of Tests , Swine , Ultrasonography/instrumentation , Ultrasonography/methods , Ultrasonography/standards , Videotape Recording , Weightlessness/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...