Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
JMIR Form Res ; 7: e47950, 2023 Aug 09.
Article in English | MEDLINE | ID: mdl-37556183

ABSTRACT

BACKGROUND: Maternal loneliness is associated with adverse physical and mental health outcomes for both the mother and her child. Detecting maternal loneliness noninvasively through wearable devices and passive sensing provides opportunities to prevent or reduce the impact of loneliness on the health and well-being of the mother and her child. OBJECTIVE: The aim of this study is to use objective health data collected passively by a wearable device to predict maternal (social) loneliness during pregnancy and the postpartum period and identify the important objective physiological parameters in loneliness detection. METHODS: We conducted a longitudinal study using smartwatches to continuously collect physiological data from 31 women during pregnancy and the postpartum period. The participants completed the University of California, Los Angeles (UCLA) loneliness questionnaire in gestational week 36 and again at 12 weeks post partum. Responses to this questionnaire and background information of the participants were collected through our customized cross-platform mobile app. We leveraged participants' smartwatch data from the 7 days before and the day of their completion of the UCLA questionnaire for loneliness prediction. We categorized the loneliness scores from the UCLA questionnaire as loneliness (scores≥12) and nonloneliness (scores<12). We developed decision tree and gradient-boosting models to predict loneliness. We evaluated the models by using leave-one-participant-out cross-validation. Moreover, we discussed the importance of extracted health parameters in our models for loneliness prediction. RESULTS: The gradient boosting and decision tree models predicted maternal social loneliness with weighted F1-scores of 0.897 and 0.872, respectively. Our results also show that loneliness is highly associated with activity intensity and activity distribution during the day. In addition, resting heart rate (HR) and resting HR variability (HRV) were correlated with loneliness. CONCLUSIONS: Our results show the potential benefit and feasibility of using passive sensing with a smartwatch to predict maternal loneliness. Our developed machine learning models achieved a high F1-score for loneliness prediction. We also show that intensity of activity, activity pattern, and resting HR and HRV are good predictors of loneliness. These results indicate the intervention opportunities made available by wearable devices and predictive models to improve maternal well-being through early detection of loneliness.

2.
JMIR Form Res ; 7: e44385, 2023 May 15.
Article in English | MEDLINE | ID: mdl-37184929

ABSTRACT

BACKGROUND: The development and quality assurance of perinatal eHealth self-monitoring systems is an upcoming area of inquiry in health science. Building patient engagement into eHealth development as a core component has potential to guide process evaluation. Access, 1 attribute of patient engagement, is the focus of study here. Access to eHealth self-monitoring programs has the potential to influence pregnancy health and wellness outcomes. Little is known about how pregnant users' ability to obtain resources is influenced by their own adaptive activities and the mediating activities of eHealth systems during the process of real-world testing of these systems. OBJECTIVE: Here, we examine the patient engagement process of access occurring during the adaptation of eHealth self-monitoring use from a sociomaterial perspective. METHODS: In this mixed methods convergent evaluation design, we interviewed women about perceptions of the adaptation process of using an eHealth self-monitoring system. Deductive analysis was conducted guided by the definition of access as an attribute of patient engagement. After initial qualitative and quantitative data collection and analysis, participants were spilt based on their level of use of the eHealth system (physical wear time of self-monitoring device). Content analysis was then conducted according to user group, using a conceptual matrix developed from ontological perspectives of sociomateriality. RESULTS: Pregnant users' adaptive activities and the mediation activities of the eHealth system represent a cocreation process that resulted in user group-specific characteristics of accessing and using the system. The high- and low-use groups experienced different personal adaptation and eHealth mediation during this process of cocreation. Differences were noted between high- and low-use groups, with the high-use group giving attention to developing skills in recording and interpreting data and the low-use group discussing the manual adding of activities to the system and how the system worked best for them when they used it in their mother tongue. CONCLUSIONS: A cocreation process between pregnant users and the eHealth system was identified, illustrating access as a useful core component of perinatal eHealth self-monitoring systems. Researchers and clinicians can observe reasons for why pregnant users access eHealth systems in unique ways based on their personal preferences, habits, and values. Mediation activities of the eHealth system and the different user adaptive activities represent a cocreation process between the users and the eHealth system that is necessary for the personalization of perinatal eHealth systems.

3.
Sex Reprod Healthc ; 35: 100820, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36774741

ABSTRACT

OBJECTIVE: The aim of this study was to compare subjectively and objectively measured stress during pregnancy and the three months postpartum in women with previous adverse pregnancy outcomes and women with normal obstetric histories. METHODS: We recruited two cohorts in southwestern Finland for this longitudinal study: (1) pregnant women (n = 32) with histories of preterm births or late miscarriages January-December 2019 and (2) pregnant women (n = 30) with histories of full-term births October 2019-March 2020. We continuously measured heart rate variability (HRV) using a smartwatch from 12 to 15 weeks of pregnancy until three months postpartum, and subjective stress was assessed with a smartphone application. RESULTS: We recruited the women in both cohorts at a median of 14.2 weeks of pregnancy. The women with previous adverse pregnancy outcomes delivered earlier and more often through Caesarean section compared with the women with normal obstetric histories. We found differences in subjective stress between the cohorts in pregnancy weeks 29 and 34. The cohort of women with previous adverse pregnancy outcomes had a higher root mean square of successive differences between normal heartbeats (RMSSD), a well-known HRV parameter, compared with the other cohort in pregnancy weeks 26 (64.9 vs 55.0, p = 0.04) and 32 (63.0 vs 52.3, p = 0.04). Subjective stress did not correlate with HRV parameters. CONCLUSIONS: Women with previous adverse pregnancy outcomes do not suffer from stress in subsequent pregnancies more than women with normal obstetric histories. Healthcare professionals need to be aware that interindividual variation in stress during pregnancy is considerable.


Subject(s)
Cesarean Section , Pregnancy Outcome , Infant, Newborn , Pregnancy , Female , Humans , Longitudinal Studies , Cesarean Section/adverse effects , Postpartum Period , Cohort Studies
4.
PLoS One ; 17(12): e0268361, 2022.
Article in English | MEDLINE | ID: mdl-36480505

ABSTRACT

BACKGROUND: Photoplethysmography (PPG) is a low-cost and easy-to-implement method to measure vital signs, including heart rate (HR) and pulse rate variability (PRV) which widely used as a substitute of heart rate variability (HRV). The method is used in various wearable devices. For example, Samsung smartwatches are PPG-based open-source wristbands used in remote well-being monitoring and fitness applications. However, PPG is highly susceptible to motion artifacts and environmental noise. A validation study is required to investigate the accuracy of PPG-based wearable devices in free-living conditions. OBJECTIVE: We evaluate the accuracy of PPG signals-collected by the Samsung Gear Sport smartwatch in free-living conditions-in terms of HR and time-domain and frequency-domain HRV parameters against a medical-grade chest electrocardiogram (ECG) monitor. METHODS: We conducted 24-hours monitoring using a Samsung Gear Sport smartwatch and a Shimmer3 ECG device. The monitoring included 28 participants (14 male and 14 female), where they engaged in their daily routines. We evaluated HR and HRV parameters during the sleep and awake time. The parameters extracted from the smartwatch were compared against the ECG reference. For the comparison, we employed the Pearson correlation coefficient, Bland-Altman plot, and linear regression methods. RESULTS: We found a significantly high positive correlation between the smartwatch's and Shimmer ECG's HR, time-domain HRV, LF, and HF and a significant moderate positive correlation between the smartwatch's and shimmer ECG's LF/HF during sleep time. The mean biases of HR, time-domain HRV, and LF/HF were low, while the biases of LF and HF were moderate during sleep. The regression analysis showed low error variances of HR, AVNN, and pNN50, moderate error variances of SDNN, RMSSD, LF, and HF, and high error variances of LF/HF during sleep. During the awake time, there was a significantly high positive correlation of AVNN and a moderate positive correlation of HR, while the other parameters indicated significantly low positive correlations. RMSSD and SDNN showed low mean biases, and the other parameters had moderate mean biases. In addition, AVNN had moderate error variance while the other parameters indicated high error variances. CONCLUSION: The Samsung smartwatch provides acceptable HR, time-domain HRV, LF, and HF parameters during sleep time. In contrast, during the awake time, AVNN and HR show satisfactory accuracy, and the other HRV parameters have high errors.


Subject(s)
Exercise , Female , Male , Humans , Heart Rate , Correlation of Data
5.
JMIR Mhealth Uhealth ; 10(6): e33458, 2022 06 03.
Article in English | MEDLINE | ID: mdl-35657667

ABSTRACT

BACKGROUND: Heart rate variability (HRV) is a noninvasive method that reflects the regulation of the autonomic nervous system. Altered HRV is associated with adverse mental or physical health complications. The autonomic nervous system also has a central role in physiological adaption during pregnancy, causing normal changes in HRV. OBJECTIVE: The aim of this study was to assess trends in heart rate (HR) and HRV parameters as a noninvasive method for remote maternal health monitoring during pregnancy and 3-month postpartum period. METHODS: A total of 58 pregnant women were monitored using an Internet of Things-based remote monitoring system during pregnancy and 3-month postpartum period. Pregnant women were asked to continuously wear Gear Sport smartwatch to monitor their HR and HRV extracted from photoplethysmogram (PPG) signals. In addition, a cross-platform mobile app was used to collect background and delivery-related information. We analyzed PPG signals collected during the night and discarded unreliable signals by applying a PPG quality assessment method to the collected signals. HR, HRV, and normalized HRV parameters were extracted from reliable signals. The normalization removed the effect of HR changes on HRV trends. Finally, we used hierarchical linear mixed models to analyze the trends of HR, HRV, and normalized HRV parameters. RESULTS: HR increased significantly during the second trimester (P<.001) and decreased significantly during the third trimester (P=.006). Time-domain HRV parameters, average normal interbeat intervals (IBIs; average normal IBIs [AVNN]), SD of normal IBIs (SDNN), root mean square of the successive difference of normal IBIs (RMSSD), normalized SDNN, and normalized RMSSD decreased significantly during the second trimester (P<.001). Then, AVNN, SDNN, RMSSD, and normalized SDNN increased significantly during the third trimester (with P=.002, P<.001, P<.001, and P<.001, respectively). Some of the frequency-domain parameters, low-frequency power (LF), high-frequency power (HF), and normalized HF, decreased significantly during the second trimester (with P<.001, P<.001, and P=.003, respectively), and HF increased significantly during the third trimester (P=.007). In the postpartum period, normalized RMSSD decreased (P=.01), and the LF to HF ratio (LF/HF) increased significantly (P=.004). CONCLUSIONS: Our study indicates the physiological changes during pregnancy and the postpartum period. We showed that HR increased and HRV parameters decreased as pregnancy proceeded, and the values returned to normal after delivery. Moreover, our results show that HR started to decrease, whereas time-domain HRV parameters and HF started to increase during the third trimester. The results also indicated that age was significantly associated with HRV parameters during pregnancy and postpartum period, whereas education level was associated with HRV parameters during the third trimester. In addition, our results demonstrate the possibility of continuous HRV monitoring in everyday life settings.


Subject(s)
Electrocardiography , Postpartum Period , Female , Heart Rate/physiology , Humans , Linear Models , Pregnancy
6.
Comput Inform Nurs ; 40(12): 856-862, 2022 Dec 01.
Article in English | MEDLINE | ID: mdl-35234703

ABSTRACT

Smart rings, such as the Oura ring, might have potential in health monitoring. To be able to identify optimal devices for healthcare settings, validity studies are needed. The aim of this study was to compare the Oura smart ring estimates of steps and sedentary time with data from the ActiGraph accelerometer in a free-living context. A cross-sectional observational study design was used. A convenience sample of healthy adults (n = 42) participated in the study and wore an Oura smart ring and an ActiGraph accelerometer on the non-dominant hand continuously for 1 week. The participants completed a background questionnaire and filled out a daily log about their sleeping times and times when they did not wear the devices. The median age of the participants (n = 42) was 32 years (range, 18-46 years). In total, 191 (61% of the potential) days were compared. The Oura ring overestimated the step counts compared with the ActiGraph. The mean difference was 1416 steps (95% confidence interval, 739-2093 steps). Daily sedentary time was also overestimated by the ring; the mean difference was 17 minutes (95% confidence interval, -2 to 37 minutes). The use of the ring in nursing interventions needs to be considered.


Subject(s)
Actigraphy , Sedentary Behavior , Adult , Humans , Adolescent , Young Adult , Middle Aged , Cross-Sectional Studies , Monitoring, Ambulatory , Exercise
7.
J Med Internet Res ; 24(1): e27487, 2022 01 18.
Article in English | MEDLINE | ID: mdl-35040799

ABSTRACT

BACKGROUND: Photoplethysmography is a noninvasive and low-cost method to remotely and continuously track vital signs. The Oura Ring is a compact photoplethysmography-based smart ring, which has recently drawn attention to remote health monitoring and wellness applications. The ring is used to acquire nocturnal heart rate (HR) and HR variability (HRV) parameters ubiquitously. However, these parameters are highly susceptible to motion artifacts and environmental noise. Therefore, a validity assessment of the parameters is required in everyday settings. OBJECTIVE: This study aims to evaluate the accuracy of HR and time domain and frequency domain HRV parameters collected by the Oura Ring against a medical grade chest electrocardiogram monitor. METHODS: We conducted overnight home-based monitoring using an Oura Ring and a Shimmer3 electrocardiogram device. The nocturnal HR and HRV parameters of 35 healthy individuals were collected and assessed. We evaluated the parameters within 2 tests, that is, values collected from 5-minute recordings (ie, short-term HRV analysis) and the average values per night sleep. A linear regression method, the Pearson correlation coefficient, and the Bland-Altman plot were used to compare the measurements of the 2 devices. RESULTS: Our findings showed low mean biases of the HR and HRV parameters collected by the Oura Ring in both the 5-minute and average-per-night tests. In the 5-minute test, the error variances of the parameters were different. The parameters provided by the Oura Ring dashboard (ie, HR and root mean square of successive differences [RMSSD]) showed relatively low error variance compared with the HRV parameters extracted from the normal interbeat interval signals. The Pearson correlation coefficient tests (P<.001) indicated that HR, RMSSD, average of normal heart beat intervals (AVNN), and percentage of successive normal beat-to-beat intervals that differ by more than 50 ms (pNN50) had high positive correlations with the baseline values; SD of normal beat-to-beat intervals (SDNN) and high frequency (HF) had moderate positive correlations, and low frequency (LF) and LF:HF ratio had low positive correlations. The HR, RMSSD, AVNN, and pNN50 had narrow 95% CIs; however, SDNN, LF, HF, and LF:HF ratio had relatively wider 95% CIs. In contrast, the average-per-night test showed that the HR, RMSSD, SDNN, AVNN, pNN50, LF, and HF had high positive relationships (P<.001), and the LF:HF ratio had a moderate positive relationship (P<.001). The average-per-night test also indicated considerably lower error variances than the 5-minute test for the parameters. CONCLUSIONS: The Oura Ring could accurately measure nocturnal HR and RMSSD in both the 5-minute and average-per-night tests. It provided acceptable nocturnal AVNN, pNN50, HF, and SDNN accuracy in the average-per-night test but not in the 5-minute test. In contrast, the LF and LF:HF ratio of the ring had high error rates in both tests.


Subject(s)
Electrocardiography , Photoplethysmography , Heart Rate , Humans , Linear Models , Sleep
8.
Sensors (Basel) ; 21(7)2021 Mar 24.
Article in English | MEDLINE | ID: mdl-33805217

ABSTRACT

Pregnancy is a unique time when many mothers gain awareness of their lifestyle and its impacts on the fetus. High-quality care during pregnancy is needed to identify possible complications early and ensure the mother's and her unborn baby's health and well-being. Different studies have thus far proposed maternal health monitoring systems. However, they are designed for a specific health problem or are limited to questionnaires and short-term data collection methods. Moreover, the requirements and challenges have not been evaluated in long-term studies. Maternal health necessitates a comprehensive framework enabling continuous monitoring of pregnant women. In this paper, we present an Internet-of-Things (IoT)-based system to provide ubiquitous maternal health monitoring during pregnancy and postpartum. The system consists of various data collectors to track the mother's condition, including stress, sleep, and physical activity. We carried out the full system implementation and conducted a real human subject study on pregnant women in Southwestern Finland. We then evaluated the system's feasibility, energy efficiency, and data reliability. Our results show that the implemented system is feasible in terms of system usage during nine months. We also indicate the smartwatch, used in our study, has acceptable energy efficiency in long-term monitoring and is able to collect reliable photoplethysmography data. Finally, we discuss the integration of the presented system with the current healthcare system.


Subject(s)
Exercise , Life Style , Female , Finland , Humans , Infant , Monitoring, Physiologic , Pregnancy , Reproducibility of Results
9.
PLoS One ; 16(2): e0246494, 2021.
Article in English | MEDLINE | ID: mdl-33534854

ABSTRACT

BACKGROUND: Technology enables the continuous monitoring of personal health parameter data during pregnancy regardless of the disruption of normal daily life patterns. Our research group has established a project investigating the usefulness of an Internet of Things-based system and smartwatch technology for monitoring women during pregnancy to explore variations in stress, physical activity and sleep. The aim of this study was to examine daily patterns of well-being in pregnant women before and during the national stay-at-home restrictions related to the COVID-19 pandemic in Finland. METHODS: A longitudinal cohort study design was used to monitor pregnant women in their everyday settings. Two cohorts of pregnant women were recruited. In the first wave in January-December 2019, pregnant women with histories of preterm births (gestational weeks 22-36) or late miscarriages (gestational weeks 12-21); and in the second wave between October 2019 and March 2020, pregnant women with histories of full-term births (gestational weeks 37-42) and no pregnancy losses were recruited. The final sample size for this study was 38 pregnant women. The participants continuously used the Samsung Gear Sport smartwatch and their heart rate variability, and physical activity and sleep data were collected. Subjective stress, activity and sleep reports were collected using a smartphone application developed for this study. Data between February 12 to April 8, 2020 were included to cover four-week periods before and during the national stay-at-home restrictions. Hierarchical linear mixed models were exploited to analyze the trends in the outcome variables. RESULTS: The pandemic-related restrictions were associated with changes in heart rate variability: the standard deviation of all normal inter-beat intervals (p = 0.034), low-frequency power (p = 0.040) and the low-frequency/high-frequency ratio (p = 0.013) increased compared with the weeks before the restrictions. Women's subjectively evaluated stress levels also increased significantly. Physical activity decreased when the restrictions were set and as pregnancy proceeded. The total sleep time also decreased as pregnancy proceeded, but pandemic-related restrictions were not associated with sleep. Daily rhythms changed in that the participants overall started to sleep later and woke up later. CONCLUSIONS: The findings showed that Finnish pregnant women coped well with the pandemic-related restrictions and lockdown environment in terms of stress, physical activity and sleep.


Subject(s)
COVID-19/pathology , Life Style , Pregnant Women , Abortion, Spontaneous , Adult , COVID-19/epidemiology , COVID-19/virology , Exercise , Female , Finland , Heart Rate , Humans , Longitudinal Studies , Pregnancy , Pregnant Women/psychology , Premature Birth , SARS-CoV-2/isolation & purification , Sleep/physiology , Smartphone , Stress, Psychological
10.
JMIR Mhealth Uhealth ; 8(10): e20465, 2020 11 02.
Article in English | MEDLINE | ID: mdl-33038869

ABSTRACT

BACKGROUND: Assessment of sleep quality is essential to address poor sleep quality and understand changes. Owing to the advances in the Internet of Things and wearable technologies, sleep monitoring under free-living conditions has become feasible and practicable. Smart rings and smartwatches can be employed to perform mid- or long-term home-based sleep monitoring. However, the validity of such wearables should be investigated in terms of sleep parameters. Sleep validation studies are mostly limited to short-term laboratory tests; there is a need for a study to assess the sleep attributes of wearables in everyday settings, where users engage in their daily routines. OBJECTIVE: This study aims to evaluate the sleep parameters of the Oura ring along with the Samsung Gear Sport watch in comparison with a medically approved actigraphy device in a midterm everyday setting, where users engage in their daily routines. METHODS: We conducted home-based sleep monitoring in which the sleep parameters of 45 healthy individuals (23 women and 22 men) were tracked for 7 days. Total sleep time (TST), sleep efficiency (SE), and wake after sleep onset (WASO) of the ring and watch were assessed using paired t tests, Bland-Altman plots, and Pearson correlation. The parameters were also investigated considering the gender of the participants as a dependent variable. RESULTS: We found significant correlations between the ring's and actigraphy's TST (r=0.86; P<.001), WASO (r=0.41; P<.001), and SE (r=0.47; P<.001). Comparing the watch with actigraphy showed a significant correlation in TST (r=0.59; P<.001). The mean differences in TST, WASO, and SE of the ring and actigraphy were within satisfactory ranges, although there were significant differences between the parameters (P<.001); TST and SE mean differences were also within satisfactory ranges for the watch, and the WASO was slightly higher than the range (31.27, SD 35.15). However, the mean differences of the parameters between the watch and actigraphy were considerably higher than those of the ring. The watch also showed a significant difference in TST (P<.001) between female and male groups. CONCLUSIONS: In a sample population of healthy adults, the sleep parameters of both the Oura ring and Samsung watch have acceptable mean differences and indicate significant correlations with actigraphy, but the ring outperforms the watch in terms of the nonstaging sleep parameters.


Subject(s)
Sleep Initiation and Maintenance Disorders , Wearable Electronic Devices , Actigraphy , Adult , Female , Humans , Male , Polysomnography , Sleep
SELECTION OF CITATIONS
SEARCH DETAIL
...