Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
Int. braz. j. urol ; 44(5): 947-951, Sept.-Oct. 2018. tab
Article in English | LILACS | ID: biblio-975642

ABSTRACT

ABSTRACT Objectives: To investigate the seasonal variations in urinary calcium, serum vitamin D, and urinary volume in patients with a history of nephrolithiasis. Materials and Methods: Patients included were those who completed a 24-hour urine metabolic evaluation on two occasions; one in summer (June-Aug) and one in winter (Nov-Jan), and who had not started any medications or been instructed on dietary modifications in the interval between the two tests that may have impacted the results. Patients were excluded if they were on thiazide diuretics or were taking calcium and / or Vitamin D supplementation. Welch's t-test was used to compare the difference in average summer and winter values. Unpaired Student t-test was used to compare baseline parameters (age, BMI), and Paired Student t-test was used to compare average seasonal measurements in men vs. women. Results: 136 patients were identified who were not taking calcium or vitamin D supplements or thiazide diuretics, and who were not instructed on dietary modifications in the interval between the two measured parameters. No significant differences were observed when comparing male to female baseline parameters of age or BMI (Table-1). Average 24-hour urine calcium was higher (226.60) in the winter than in summer (194.18) and was significant in males (p = 0.014) and females (p < 0.001). No significant seasonal difference was seen in 24-hour urine volume or serum vitamin D levels. Conclusions: Urinary calcium is higher in winter months compared to summer months. As such, tailoring medical preventative strategies to the time of year may be helpful.


Subject(s)
Humans , Female , Vitamin D/urine , Kidney Calculi/urine , Calcium/urine , Seasons , Kidney Calculi/etiology , Retrospective Studies , Urinalysis , Middle Aged
2.
Int Braz J Urol ; 44(5): 947-951, 2018.
Article in English | MEDLINE | ID: mdl-29757578

ABSTRACT

OBJECTIVES: To investigate the seasonal variations in urinary calcium, serum vitamin D, and urinary volume in patients with a history of nephrolithiasis. MATERIALS AND METHODS: Patients included were those who completed a 24-hour urine metabolic evaluation on two occasions; one in summer (June-Aug) and one in winter (Nov-Jan), and who had not started any medications or been instructed on dietary modifications in the interval between the two tests that may have impacted the results. Patients were excluded if they were on thiazide diuretics or were taking calcium and / or Vitamin D supplementation. Welch's t-test was used to compare the difference in average summer and winter values. Unpaired Student t-test was used to compare baseline parameters (age, BMI), and Paired Student t-test was used to compare average seasonal measurements in men vs. women. RESULTS: 136 patients were identified who were not taking calcium or vitamin D supplements or thiazide diuretics, and who were not instructed on dietary modifications in the interval between the two measured parameters. No significant differences were observed when comparing male to female baseline parameters of age or BMI (Table-1). Average 24-hour urine calcium was higher (226.60) in the winter than in summer (194.18) and was significant in males (p = 0.014) and females (p < 0.001). No significant seasonal difference was seen in 24-hour urine volume or serum vitamin D levels. CONCLUSIONS: Urinary calcium is higher in winter months compared to summer months. As such, tailoring medical preventative strategies to the time of year may be helpful.


Subject(s)
Calcium/urine , Kidney Calculi/urine , Vitamin D/urine , Female , Humans , Kidney Calculi/etiology , Male , Middle Aged , Retrospective Studies , Seasons , Urinalysis
3.
Int. braz. j. urol ; 43(5): 880-886, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-892890

ABSTRACT

ABSTRACT Background: With a high rate of recurrence, urolithiasis is a chronic disease that impacts quality of life. The Patient Reported Outcomes Measurement Information System is an NIH validated questionnaire to assess patient quality of life. We evaluated the impact of urolithiasis on quality of life using the NIH-sponsored PROMIS-43 questionnaire. Materials and Methods: Patients reporting to the kidney stone clinic were interviewed to collect information on stone history and demographic information and were asked to complete the PROMIS-43 questionnaire. Quality of life scores were analyzed using gender and age matched groups for the general US population. Statistical comparisons were made based on demographic information and patient stone history. Statistical significance was P<0.05. Results: 103 patients completed the survey. 36% of respondents were male, the average age of the group was 52 years old, with 58% primary income earners, and 35% primary caregivers. 7% had never passed a stone or had a procedure while 17% passed 10 or more stones in their lifetime. Overall, pain and physical function were worse in patients with urolithiasis. Primary income earners had better quality of life while primary caregivers and those with other chronic medical conditions were worse. Patients on dietary and medical therapy had better quality of life scores. Conclusions: Urolithiasis patients subjectively have worse pain and physical function than the general population. The impact of pain on quality of life was greatest in those patients who had more stone episodes, underscoring the importance of preventive measures. Stone prevention measures improve quality of life.


Subject(s)
Humans , Male , Female , Adult , Aged , Quality of Life/psychology , Urolithiasis/psychology , Patient Reported Outcome Measures , Pain/etiology , Pain/psychology , Sleep Wake Disorders/etiology , Sleep Wake Disorders/psychology , Information Systems , Case-Control Studies , Chronic Disease , Surveys and Questionnaires , Depression/etiology , Depression/psychology , Urolithiasis/complications , Fatigue/etiology , Fatigue/psychology , Middle Aged
4.
Int Braz J Urol ; 43(5): 880-886, 2017.
Article in English | MEDLINE | ID: mdl-28792186

ABSTRACT

BACKGROUND: With a high rate of recurrence, urolithiasis is a chronic disease that impacts quality of life. The Patient Reported Outcomes Measurement Information System is an NIH validated questionnaire to assess patient quality of life. We evaluated the impact of urolithiasis on quality of life using the NIH-sponsored PROMIS-43 questionnaire. MATERIALS AND METHODS: Patients reporting to the kidney stone clinic were interviewed to collect information on stone history and demographic information and were asked to complete the PROMIS-43 questionnaire. Quality of life scores were analyzed using gender and age matched groups for the general US population. Statistical comparisons were made based on demographic information and patient stone history. Statistical significance was P<0.05. RESULTS: 103 patients completed the survey. 36% of respondents were male, the average age of the group was 52 years old, with 58% primary income earners, and 35% primary caregivers. 7% had never passed a stone or had a procedure while 17% passed 10 or more stones in their lifetime. Overall, pain and physical function were worse in patients with urolithiasis. Primary income earners had better quality of life while primary caregivers and those with other chronic medical conditions were worse. Patients on dietary and medical therapy had better quality of life scores. CONCLUSIONS: Urolithiasis patients subjectively have worse pain and physical function than the general population. The impact of pain on quality of life was greatest in those patients who had more stone episodes, underscoring the importance of preventive measures. Stone prevention measures improve quality of life.


Subject(s)
Patient Reported Outcome Measures , Quality of Life/psychology , Urolithiasis/psychology , Adult , Aged , Case-Control Studies , Chronic Disease , Depression/etiology , Depression/psychology , Fatigue/etiology , Fatigue/psychology , Female , Humans , Information Systems , Male , Middle Aged , Pain/etiology , Pain/psychology , Sleep Wake Disorders/etiology , Sleep Wake Disorders/psychology , Surveys and Questionnaires , Urolithiasis/complications
5.
J Endourol ; 31(6): 577-582, 2017 06.
Article in English | MEDLINE | ID: mdl-28340535

ABSTRACT

OBJECTIVE: In the perioperative period, renin-angiotensin-aldosterone system (RAAS) inhibitors may result in cardiovascular and renal functional changes. We sought to determine the acute and chronic renal functional and blood pressure effects of continuing or withdrawing angiotensin-converting enzyme inhibitors (ACE-I) and angiotensin receptor blockers (ARBs) after percutaneous nephrolithotomy (PCNL). MATERIALS AND METHODS: This was a retrospective review of all patients undergoing PCNL at our institution from 2002 to 2013. Patients on either an ACE-I and/or ARB who received an ACE-I and/or ARB during their surgical hospitalization were matched based on sex, age, and body mass index to patients who had their medication withheld during the postoperative period. The two groups were compared. RESULTS: A total of 2784 patients underwent PCNL during the study period. At the time of PCNL, 15.2% (423/2784) of patients and 6.5% (181/2784) were prescribed an ACE-I and an ARB, respectively. Fifty-nine percent (248/423) of patients on an ACE-I and 66.9% (121/181) on an ARB received their medication during their postoperative hospitalization. There was no significant difference in average length of stay (2 days vs 2 days), perioperative change in glomerular filtration rate, glomerular filtration rate (GFR) (-0.50 mL/min/1.73 m2 vs -2.34 mL/min/1.73 m2, p = 0.267), change in GFR at 1 month postoperatively (-4.63 mL/min/1.73 m2 vs -5.90 mL/min/1.73 m2, p = 0.748), or change in GFR at 1 year (-2.08 mL/min/1.73 m2 vs -0.13 mL/min/1.73 m2, p = 0.267) between patients who received vs withheld their medication during the postoperative stay. CONCLUSION: It is safe to continue RAAS inhibitors in patients undergoing PCNL during their operative hospitalization.


Subject(s)
Angiotensin Receptor Antagonists/therapeutic use , Angiotensin-Converting Enzyme Inhibitors/therapeutic use , Kidney Calculi/surgery , Nephrolithotomy, Percutaneous , Aged , Angiotensin Receptor Antagonists/administration & dosage , Angiotensin-Converting Enzyme Inhibitors/administration & dosage , Female , Glomerular Filtration Rate , Humans , Kidney Calculi/drug therapy , Length of Stay , Male , Middle Aged , Perioperative Period , Randomized Controlled Trials as Topic , Retrospective Studies
6.
Int Braz J Urol ; 42(3): 546-9, 2016.
Article in English | MEDLINE | ID: mdl-27286119

ABSTRACT

OBJECTIVES: To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. MATERIALS AND METHODS: We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recente pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered na inaccurate result. RESULTS: A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). CONCLUSIONS: Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.


Subject(s)
Hydrogen-Ion Concentration , Urinalysis/methods , Urine/chemistry , Urolithiasis , Electrodes , Humans , Logistic Models , Predictive Value of Tests , Reference Standards , Reference Values , Reproducibility of Results , Retrospective Studies , Time Factors , Urinalysis/instrumentation , Urolithiasis/urine
7.
Int. braz. j. urol ; 42(3): 546-549, graf
Article in English | LILACS | ID: lil-785718

ABSTRACT

ABSTRACT Objectives To determine whether spot urine pH measured by dipstick is an accurate representation of 24 hours urine pH measured by an electrode. Materials and Methods We retrospectively reviewed urine pH results of patients who presented to the urology stone clinic. For each patient we recorded the most recent pH result measured by dipstick from a spot urine sample that preceded the result of a 24-hour urine pH measured by the use of a pH electrode. Patients were excluded if there was a change in medications or dietary recommendations or if the two samples were more than 4 months apart. A difference of more than 0.5 pH was considered an inaccurate result. Results A total 600 patients were retrospectively reviewed for the pH results. The mean difference in pH between spot urine value and the 24 hours collection values was 0.52±0.45 pH. Higher pH was associated with lower accuracy (p<0.001). The accuracy of spot urine samples to predict 24-hour pH values of <5.5 was 68.9%, 68.2% for 5.5 to 6.5 and 35% for >6.5. Samples taken more than 75 days apart had only 49% the accuracy of more recent samples (p<0.002). The overall accuracy is lower than 80% (p<0.001). Influence of diurnal variation was not significant (p=0.588). Conclusions Spot urine pH by dipstick is not an accurate method for evaluation of the patients with urolithiasis. Patients with alkaline urine are more prone to error with reliance on spot urine pH.


Subject(s)
Humans , Urine/chemistry , Urinalysis/methods , Urolithiasis/urine , Hydrogen-Ion Concentration , Reference Standards , Reference Values , Time Factors , Logistic Models , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies , Urinalysis/instrumentation , Electrodes
8.
Urology ; 88: 49-56, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26546812

ABSTRACT

OBJECTIVE: To determine how kidney stone patients' knowledge, behaviors, and preferences toward fluid intake differed from those reporting being successful or unsuccessful at increasing fluid intake for prevention. MATERIALS AND METHODS: Three hundred two kidney stone patients filled out a survey on stone history, fluid intake success, and knowledge, behaviors, and preferences toward fluid intake. Responses were compared between those reporting being very successful at fluid intake and those reporting being not successful or only somewhat successful. Self-reported fluid intake success was correlated in a subset of 41 subjects using 24-hour urine volumes. RESULTS: Self-reported fluid intake success correlated significantly with 24-hour urine volumes. Unsuccessful fluid drinkers were less likely to be aware of their future stone risk and were less likely to be counseled on prevention by a urologist. Successful fluid drinkers reported the fewest barriers per person, were more likely to prefer water for fluid intake, and were more likely to like the "taste" of water. Strategies used for remembering to drink varied significantly with those unsuccessful most often reporting "just tried to remember" and those successful at fluid intake most likely to carry a water bottle. All groups reported similar perceived severity from stones, perceived benefits of drinking fluids, and preference for using urine color to monitor hydration. CONCLUSION: Awareness of future stone risk, preference for water, counseling on stone prevention by a urologist, and specific strategies used for increasing fluid intake varied between patients who were successful or unsuccessful with fluid intake. Addressing these differences may help improve fluid intake success.


Subject(s)
Drinking , Health Knowledge, Attitudes, Practice , Kidney Calculi/therapy , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Remission Induction , Self Report , Surveys and Questionnaires , Young Adult
9.
Int Braz J Urol ; 41(1): 134-8, 2015.
Article in English | MEDLINE | ID: mdl-25928519

ABSTRACT

OBJECTIVE: To identify whether stabilization of larger bladder stones would improve the efficacy of combination (ultrasonic/pneumatic) lithotripsy in a phantom bladder stone model for percutaneous cystolithopaxy. MATERIALS AND METHODS: Using 1cm phantom Bego stones, a spherical model bladder was used to simulate percutaneous bladder access. A UroNet (US Endoscopy, USA) was placed alongside a Swiss Lithoclast probe through the working channel of a Storz 26Fr rigid nephroscope. Using a 30Fr working sheath, the stone was captured, and fragmented for 60 seconds. Resulting fragments and irrigation were filtered through a 1mm strainer, and recorded. Five trials were performed with and without the UN. Durability was then assessed by measuring net defects, and residual grasp strength of each instrument. Descriptive statistics (mean, standard deviations) were used to summarize the data, and Student's t-tests (alpha < 0.05) were used to compare trials. RESULTS: The mean time to stone capture was 12s (8-45s). After fragmentation with UN stabilization, there were significant improvements in the amount of residual stone (22% dry weight reduction vs 8.1% without UN, p < 0.001), number of fragments (17.5 vs 5.0 frag/stone, p=0.0029), and fragment size (3.6mm vs. 7.05 mm, p=0.035). Mesh defects were noted in all nets, ranging from 2-14 mm, though all but one net retained their original grip strength (36.8N). CONCLUSIONS: Bladder stone stabilization improved fragmentation when used in conjunction with ultrasonic/pneumatic lithotripsy. However, due to limitations in maneuverability and durability of the UN, other tools need to identified for this indication.


Subject(s)
Lithotripsy/instrumentation , Lithotripsy/methods , Urinary Bladder Calculi/therapy , Equipment Design , Medical Illustration , Reproducibility of Results , Time Factors
11.
Urology ; 85(4): 757-63, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25661780

ABSTRACT

OBJECTIVE: To investigate the functional characteristics of the traditional and new single-wire ureteral access sheath (UAS) configurations relating to insertion, positioning, tissue injury, and durability. MATERIALS AND METHODS: Four UAS were tested: Navigator HD (11/13F, Boston Scientific), Re-Trace (10/12F, Coloplast), Flexor-Parallel (P), and Flexor-Regular (R; 9.5/11.5F, Cook Medical). UASs were evaluated for sharpness-(1) foil perforation, (2) tissue skiving (advancing sheath/dilator against fixed foil or bologna models); rigidity-(3) tip bending, (4) sheath buckling; (5) lubricity (dynamic friction through bologna), (6) dilator removal force, (7) kinking forces (side wall compressive forces), and (8) radiopacity. New UASs were used for each trial. A motorized sliding stage was used, and continuous force measurements were recorded with a Mark-10 digital force gauge. RESULTS: The Navigator HD had the largest external diameter (13.02F). Re-Trace had the longest (51 mm) and most flexible tip (0.942 lb, P <.001). Flexor-R had the shortest (23.2 mm) and stiffest tip (7.48 lb). The Cook tip perforation forces were highest (0.807 lb), whereas the sheath required the most force (0.25 lb, P <.001) and caused the least damage (4.95 mm) when advanced against tissue. Navigator HD had the least frictional resistance (0.14 lb, P <.001). The single-wire systems had the lowest buckling forces (Navigator HD, 0.41 lb; Flexor-R, 0.827 lb; Flexor-P, 0.445 lb; Re-Trace, 1.014 lb; P <.001) and the highest dilator removal forces compared with classic systems (Flexor-P, 1.39 lb; Re-Trace, 1.9 lb; Navigator HD, 0.190 lb; Flexor-R, 0.194 lb; P <.001). The differences in kinking forces and radiopacity were not significant. CONCLUSION: The Navigator HD was the most slippery and rigid sheath, whereas the single-wire systems had lower buckling forces and required more force to remove their dilators. Cook sheaths appeared the least traumatic.


Subject(s)
Equipment Failure , Ureteroscopy/instrumentation , Equipment Design , Friction , Materials Testing , Pressure
12.
Int. braz. j. urol ; 41(1): 134-138, jan-feb/2015. graf
Article in English | LILACS | ID: lil-742866

ABSTRACT

Objective To identify whether stabilization of larger bladder stones would improve the efficacy of combination (ultrasonic/pneumatic) lithotripsy in a phantom bladder stone model for percutaneous cystolithopaxy. Materials and Methods Using 1cm phantom Bego stones, a spherical model bladder was used to simulate percutaneous bladder access. A UroNet (US Endoscopy, USA) was placed alongside a Swiss Lithoclast probe through the working channel of a Storz 26Fr rigid nephroscope. Using a 30Fr working sheath, the stone was captured, and fragmented for 60seconds. Resulting fragments and irrigation were filtered through a 1mm strainer, and recorded. Five trials were performed with and without the UN. Durability was then assessed by measuring net defects, and residual grasp strength of each instrument. Descriptive statistics (mean, standard deviations) were used to summarize the data, and Student’s t-tests (alpha<0.05) were used to compare trials. Results The mean time to stone capture was 12s (8-45s). After fragmentation with UN stabilization, there were significant improvements in the amount of residual stone (22% dry weight reduction vs 8.1% without UN, p<0.001), number of fragments (17.5 vs 5.0 frag/stone, p=0.0029), and fragment size (3.6mm vs. 7.05 mm, p=0.035). Mesh defects were noted in all nets, ranging from 2-14 mm, though all but one net retained their original grip strength (36.8N). Conclusions Bladder stone stabilization improved fragmentation when used in conjunction with ultrasonic/pneumatic lithotripsy. However, due to limitations in maneuverability and durability of the UN, other tools need to identified for this indication. .


Subject(s)
Lithotripsy/instrumentation , Lithotripsy/methods , Urinary Bladder Calculi/therapy , Equipment Design , Medical Illustration , Reproducibility of Results , Time Factors
13.
Urology ; 85(2): 296-8, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25623669

ABSTRACT

OBJECTIVE: To identify what risk factors on 24-hour urinalysis, if any, predispose patients to have higher percentages of uric acid (UA) stone composition in their stones, with specific emphasis on patients with pure UA stones. METHODS: We retrospectively identified 308 patients from review of a kidney stone analysis database. Patients were grouped according to the percentage UA composition: 10%-20%, 30%-50%, 60%-90%, and 100% UA. Data were extracted from 24-hour urine collections and serum chemistries. Patients taking allopurinol, citrates, or thiazide diuretics were excluded. RESULTS: The percentage UA stone composition increased as patients became older (P = .05) or heavier (P <.001). Gender did not impact the percentage of UA in stones. Although a higher serum UA level was associated with higher UA stone composition (P <.0006), urinary UA levels did not correlate (P = .1). In contrast, urinary pH correlated significantly with higher UA stone composition (P = .03). CONCLUSION: Older and heavier patients with higher serum UA levels are more likely to have a pure UA stone. This information combined with traditional predictors (urine pH, radiopacity of stone, and Hounsfield units) may help identify those most likely to respond to dissolution therapy.


Subject(s)
Kidney Calculi/chemistry , Uric Acid/analysis , Female , Humans , Kidney Calculi/etiology , Male , Middle Aged , Retrospective Studies , Risk Factors
14.
J Endourol ; 29(2): 162-70, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25083583

ABSTRACT

PURPOSE: To conduct a comparative evaluation of ultrasonic, pneumatic, and dual ultrasonic (DUS) lithotripsy to predict the safety of probes on urinary tract tissue. MATERIALS AND METHODS: The Swiss Lithoclast Ultra (ultrasonic-only [US] and ultrasonic-pneumatic combination [US+P]) and the Gyrus ACMI Cyberwand (DUS) were evaluated. Fresh porcine ureter, bladder, and renal pelvis tissues were used with a hands-free setup to vertically apply 0, 400, or 700 g of force with each probe for a duration of 3 seconds, 5 seconds, or 3 minutes (or until perforation occurred). Data collection included whether perforation occurred and time to perforation. Histological analysis of nonperforated samples was used to compare the anatomical depth to which damage occurred. RESULTS: The total percentage of trials resulting in perforation for all tissue types, contact durations, and forces was found to be 8.5% (10/117) for US, 13.7% (16/117) for US+P, and 26.4% (31/117) for DUS. No perforations occurred with light contact (0 g) of probe force, regardless of tissue type, lithotripsy mode, or contact duration. Overall, the renal pelvis was most resistant to perforation (p=0.0004), while no difference was found between the bladder and ureter tissue (p=0.32). Force beyond 400 g and contact greater than 5 seconds increased risk for damage. CONCLUSIONS: Mode of lithotripsy, tissue type, probe force, and probe-tissue contact duration all significantly impacted the extent of damage and likelihood for perforation to occur. All devices and tissue types provided a reasonable margin of safety for probe-tissue contact times of 3 and 5 seconds with no more than 400 g of force.


Subject(s)
Kidney Pelvis/injuries , Lithotripsy/adverse effects , Ureter/injuries , Urinary Bladder/injuries , Animals , In Vitro Techniques , Lithotripsy/methods , Swine
15.
Urology ; 84(3): 544-8, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25168531

ABSTRACT

OBJECTIVE: To evaluate the impact of diabetic medications and glycemic control on the urine pH, 24-hour urine stone risk profile, and stone composition. PATIENTS AND METHODS: We retrospectively reviewed our database searching for type-2 diabetic patients with kidney stones from July 2002 to January 2013. Patients were divided in 2 groups according to their diabetic medications: insulin vs oral antihyperglycemics. Patients were compared based on their urine collections and stone composition. A linear regression was done to assess which variables could predict a low urine pH. In a subgroup analysis, patients on thiazolidinediones (ie, pioglitazone) were compared with patients on other oral antihyperglycemics. RESULTS: We analyzed 1831 type-2 diabetic patients with stone disease; 375 (20.5%) were included in the insulin group and 1456 (79.5%) in the antihyperglycemics group. Linear regression revealed male gender (P = .011) and insulin therapy (P <.001) as protective factors of low urine pH, whereas HbA1c level (P <.001) was inversely related to the urine pH (odds ratio, -0.066; 95% confidence interval, -0.096 to -0.036; P <.001). There were no significant differences in other 24-h urine stone risk parameters or stone composition between the groups. There were also no significant differences in the subgroup analysis. CONCLUSION: Urine pH is inversely related to HbA1c level. Insulin therapy is associated with higher urine pH than oral antihyperglycemic agents despite higher HbA1c suggesting that insulin may modify urine pH independent of glycemic control.


Subject(s)
Diabetes Mellitus, Type 2/complications , Hypoglycemic Agents/administration & dosage , Insulin/administration & dosage , Kidney Calculi/complications , Administration, Oral , Aged , Body Mass Index , Diabetes Mellitus, Type 2/drug therapy , Female , Glycated Hemoglobin/chemistry , Humans , Hydrogen-Ion Concentration , Kidney Calculi/pathology , Linear Models , Male , Middle Aged , Odds Ratio , Pioglitazone , Retrospective Studies , Risk , Thiazolidinediones/administration & dosage
16.
Urology ; 83(5): 1060-4, 2014 May.
Article in English | MEDLINE | ID: mdl-24767521

ABSTRACT

OBJECTIVE: To evaluate regional differences in adaptation of best practice recommendations for extracorporeal shock wave lithotripsy (SWL) across 4 distinct geographic regions. METHODS: A retrospective study was performed using a prospective database maintained by a mobile lithotripsy provider (ForTec Medical, Streetsboro, OH). SWL cases performed in Ohio, Northern Illinois/Southern Wisconsin, Florida, and New York were included. Treatment parameters evaluated included treatment rate, use of a power ramp-up protocol, use of a pretreatment pause after the initial 100 shocks, ancillary procedures, and need for retreatment. Regional and physician-specific patterns were examined. Statistical analyses using chi-square and analysis of variance were performed with a significance of P <.05. RESULTS: Data from 2240 SWL procedures were included in the study. Overall adaptation of power ramp-up protocols and treatment rates were high (93% and 93%), whereas use of pause was lower (75%, P <.001). Retreatment rates were low (4.3%), although ancillary procedures were performed in 34% of patients, and 8.3% of patients received stents for stones <1 cm. Regional differences were present in all parameters: Florida physicians used power ramp-up less (83%, P <.001) but had good use of pretreatment pause (98%, P <.001), both Wisconsin/Illinois and New York were less likely to use slow rate (87% and 84%, respectively, P <.001). CONCLUSION: The recommendations for slower shock wave rates and power ramp protocols have reached high penetration in urologic practices; however, the more recent recommendation for a pause after the initial 100 shocks has been less uniformly implemented. Inconsistencies in regional adaptation of best practices may identify opportunities for further education.


Subject(s)
Benchmarking , Kidney Calculi/therapy , Lithotripsy , Practice Patterns, Physicians' , Female , Humans , Male , Middle Aged , Practice Guidelines as Topic , Prospective Studies , Retrospective Studies , United States
17.
J Endourol ; 28(2): 248-51, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24032438

ABSTRACT

INTRODUCTION: Obese patients have an increased risk of kidney stones, and several studies have identified specific urinary derangements on 24-hour collections. The objective of this study was to assess obese and super-obese stone formers, and their compliance with dietary modifications over time, based on 24-hour urine outcomes. PATIENTS AND METHODS: A retrospective review was performed searching for all stone formers who completed a 24-hour urine collection before and after dietary counseling for stone prevention. Patients were excluded if placed on medical therapy in addition to dietary therapy. Patients were divided in three main groups according to their body mass index (BMI): 30, 30-40, and >40 kg/m(2). Demographic data and 24-hour urine stone risk parameters (volume, sodium, uric acid, citrate, and oxalate) were assessed. Initial 24-hour urine results were compared to follow-up results after dietary counseling. Then, the outcomes from each group were compared to each other. RESULTS: Two hundred and fourteen stone formers (67% male) were identified with a mean age of 49.5±15.0 years. One hundred twenty-eight (59.8%) patients had BMI <30 kg/m(2), 61 (28.5%) between 30-40 kg/m(2), and 25 (11.7%) >40 kg/m(2). Among patients with BMI <30 kg/m(2), there were significant improvements in all urinary parameters (p<0.001) as well as in the group with BMI between 30 to 40 kg/m(2) (p=0.02 for oxalate, p<0.001 for other parameters). Among super-obese patients, there were significant improvements in the urinary volume (p=0.03), sodium (p<0.001), uric acid (p=0.001), and oxalate (p<0.001). There were no significant differences in the improvements observed in the urinary volume (p=0.69), sodium (p=0.08), uric acid (p=0.17), and citrate levels (p=0.97) between the groups. CONCLUSION: Dietary recommendations can be an equally effective strategy in decreasing the risk or stone recurrence in obese and super-obese kidney stone formers as it is in those who are not obese.


Subject(s)
Dietary Supplements , Kidney Calculi/diet therapy , Obesity/complications , Adult , Body Mass Index , Citric Acid/urine , Female , Follow-Up Studies , Humans , Kidney Calculi/etiology , Kidney Calculi/urine , Male , Middle Aged , Obesity/urine , Oxalates/urine , Retrospective Studies , Sodium/urine , Uric Acid/urine
18.
J Endourol ; 28(5): 549-53, 2014 May.
Article in English | MEDLINE | ID: mdl-24341909

ABSTRACT

INTRODUCTION: The Thermedx Fluid Management System (TFMS) is an automated pressurized irrigation system that allows concurrent temperature control. Developed for use in multiple surgical specialties, it provides settings specific to several endoscopic urologic procedures. The objective of this study was to critically appraise the functional characteristics and precision of the device regarding irrigation warming, pressurization, and flow during semirigid ureteroscopy. METHODS: Using an in vitro model, the TFMS was assessed using the proprietary urology tubing with and without a short semirigid ureteroscopy/ureteroscope (URS) (7.4F/35 cm Wolf 425612). Pressures and temperatures were measured using continuous digital sensors (Meriam m1550-gi0015, and Taylor Digital Thermometer 9842). Stepwise increases in settings were measured with and without the ureteroscope (from 100 to 200 mm Hg), and with and without the included pressure release valve (preset for 150 mm Hg). Continuous measures (60/min) were recorded and compared with values recorded by the internal unit sensors. RESULTS: At room temperature (18.1°C), the starting irrigation temperature was 19.5°C, increasing to 35.5°C after 7.2 minutes at maximum settings (40°C). Irrigation returned to baseline temperature after 6.7 minutes with the heater disabled. The irrigation temperature was not affected by changes in pressure settings and flow rates. The unit's display readings were 4°C-6°C higher than measured at the tip of the ureteroscope. Flow rates detected at the tip of the URS were 2%-8% less than the unit reported. Pressures were between 8%-17% higher using URS than that reported by the unit, and highest values were encountered when the physical safety pop-off valve was removed from the tubing. CONCLUSIONS: The TFMS provides a pressurized/warmed irrigation strategy for many endoscopic procedures. It is important to note that the system underestimates pressures at the tip of the endoscope, while overestimating the flow rates and temperatures delivered from the scope when utilizing the device.


Subject(s)
Therapeutic Irrigation/instrumentation , Ureteroscopy/instrumentation , Data Display , Equipment Design , Humans , Pressure , Rheology , Temperature , Therapeutic Irrigation/methods , Time Factors , Ureteroscopes , Ureteroscopy/methods , Urology/instrumentation
19.
J Urol ; 191(3): 667-72, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24055417

ABSTRACT

PURPOSE: We studied the impact of dyslipidemia on 24-hour urinalysis and stone composition. MATERIALS AND METHODS: We retrospectively identified patients with nephrolithiasis who underwent 24-hour urinalysis and lipid profile evaluation within 3 months. Patients were divided into groups based on total cholesterol, high density lipoprotein, nonhigh density lipoprotein and triglycerides. The groups were compared based on demographic data, diabetes, hypertension and each component of 24-hour urinalysis and stone composition. Multivariate analysis and linear regression were performed to control for potential confounders, including age, gender, body mass index, diabetes and hypertension. RESULTS: A total of 2,442 patients with a mean age of 51.1 years were included in study. On multivariate analysis patients with high total cholesterol had significantly higher urinary potassium and calcium, those with low high density lipoprotein or high triglycerides had significantly higher urinary sodium, oxalate and uric acid with lower pH, and those with high nonhigh density lipoprotein had higher urinary sodium and uric acid. Regarding stone composition, high total cholesterol and triglycerides were significantly associated with a higher uric acid stone rate (p = 0.006 and <0.001, respectively). Linear regression showed a significant association of nonhigh density lipoprotein with higher urinary sodium (p = 0.011) and uric acid (p <0.001) as well as triglycerides and higher uric acid (p = 0.017), and lower urinary pH (p = 0.005). CONCLUSIONS: There is a link between dyslipidemia and kidney stone risk that is independent of other components of metabolic syndrome such as diabetes and obesity. Specific alterations in the patient lipid profiles may portend unique aberrations in urine physicochemistry and stone risk.


Subject(s)
Dyslipidemias/complications , Nephrolithiasis/etiology , Age Factors , Body Mass Index , Diabetes Mellitus, Type 2/complications , Dyslipidemias/urine , Female , Humans , Hydrogen-Ion Concentration , Hypertension/complications , Male , Middle Aged , Nephrolithiasis/urine , Retrospective Studies , Risk , Sex Factors , Urinalysis
20.
Int Braz J Urol ; 39(4): 579-86, 2013.
Article in English | MEDLINE | ID: mdl-24054387

ABSTRACT

PURPOSE: to test the effect of stone entrapment on laser lithotripsy efficiency. MATERIALS AND METHODS: Spherical stone phantoms were created using the BegoStone® plaster. Lithotripsy of one stone (1.0 g) per test jar was performed with Ho:YAG laser (365 µm fiber; 1 minute/trial). Four laser settings were tested: I-0.8 J,8 Hz; II-0.2J,50 Hz; III-0.5 J,50 Hz; IV-1.5 J,40 Hz. Uro-Net (US Endoscopy) deployment was used in 3/9 trials. Post-treatment, stone fragments were strained though a 1mm sieve; after a 7-day drying period fragments and unfragmented stone were weighed. Uro-Net nylon mesh and wire frame resistance were tested (laser fired for 30s). All nets used were evaluated for functionality and strength (compared to 10 new nets). Student's T test was used to compare the studied parameters; significance was set at p < 0.05. RESULTS: Laser settings I and II caused less damage to the net overall; the mesh and wire frame had worst injuries with setting IV; setting III had an intermediate outcome; 42% of nets were rendered unusable and excluded from strength analysis. There was no difference in mean strength between used functional nets and non-used devices (8.05 vs. 7.45 lbs, respectively; p = 0.14). Setting IV was the most efficient for lithotripsy (1.9 ± 0.6 mg/s; p < 0.001) with or without net stabilization; setting III was superior to I and II only if a net was not used. CONCLUSIONS: Laser lithotripsy is not optimized by stone entrapment with a net retrieval device which may be damaged by high energy laser settings.


Subject(s)
Lasers, Solid-State/therapeutic use , Lithotripsy, Laser/instrumentation , Lithotripsy, Laser/methods , Nephrostomy, Percutaneous/methods , Urinary Calculi/therapy , Equipment Design , Materials Testing , Medical Illustration , Reproducibility of Results , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...